Solar Energy Technology - 32
Solar Energy Technology - 32
V.V.Satyamurty
Professor of Mechanical Engineering
INDIAN INSTITUTE OF TECHNOLOGY
Kharagpur 721302, INDIA
Lecture 32 The , f – Chart Method-II
Tank Losses and Finite Heat Exchanger
It has been noted that the , f – Chart
correlation,
f maxY 0.015 exp 3.85 f 1 1 exp 0.15 X ' RS0.76
takes into account, the non-standard storage,
but developed assuming no tank losses and
an infinite heat exchanger
Inclusion of Tank Losses
Let Q tan k be the rate of energy loss from the
tank
1
Let the tank be at a guessed temperature
of Tt1
.
The tank loses energy to the surrounding at
Ta' , that may differ from the ambient
temperature
Q tan k (UA )tan k ( Tt1 Ta' )
In general ,
|(Tt n Tt n1 )| 0.10 C
Finite Heat Excjanger
The effect of the heat exchanger is to
increase the Tmin
The collector is now required to supply
energy at or above,
Tmin
1
Tmin T 1
X C ,min
1
I c,min FRU L Tmin T a FR
IT ,n rt n Rn K T H o