USER MANUAL
1
BMS MASTER CONTROL MANUAL
Run the Setup.exe application in the Installer folder on your Setup CD. Click “Next” at the Welcome to
the BMS Master Control Installation Wizard.
You have now successfully installed the software. Click the “Finish” button to exit the installation.
2 www.rec-bms.com
BMS MASTER CONTROL MANUAL
When the RS-485 communication cable is inserted in the USB for the first time in Windows XP and older,
the device is not recognized. The Found New Hardware Wizard pop-up window appears. Choose “Install
the software automatically” option and click Next.
Windows completes the Found New Hardware Wizard by clicking the “Finish” button.
3 www.rec-bms.com
BMS MASTER CONTROL MANUAL
The RS-485 cable behaves as virtual com port (VCP). A number is assigned to the VCP in the Control
panel/System/Device Manager under Ports (COM & LPT). This port number is used to set the
communication parameters in the Set communication properties window of the BMS Control software.
4 www.rec-bms.com
BMS MASTER CONTROL MANUAL
You can now run the BMS Control software. If this is the first time you have been running the program,
the VCP has not been set yet and the Error 10733807346 occurs. You must follow the procedure
described below. Click the “Continue” button.
The BMS is not connected to the BMS Control software, the sign is turned on and Reading
BMS configuration window pops out. Click the “Cancel” button and open Set communication
properties in the Program menu.
5 www.rec-bms.com
BMS MASTER CONTROL MANUAL
Select the COM port number that was assigned by VCP and set the parameters as they are listed in Table
1:
When the communication properties are set properly, the Present? Light turns green. To confirm the
settings, press “OK”.
If you are using Windows 7 Premium Home Edition, the BMS communicate software is unable to detect
the dedicated RS-485 cable on COM port. Extra drivers should be installed. Run Visa426Full.zip file on
your installation CD and wait until it extracts to a temporary location on your computer.
6 www.rec-bms.com
BMS MASTER CONTROL MANUAL
For the RS485 Cable to work, only Serial, USB and COM Support Drivers under “Run Time Support”
should be chosen.
7 www.rec-bms.com
BMS MASTER CONTROL MANUAL
When BMS and BMS Master Control software on the PC are properly connected, the program
downloads all system parameters the Settings tab.
8 www.rec-bms.com
BMS MASTER CONTROL MANUAL
If you want to change the settings of your BMS, the BMS has to be unlocked first. To unlock the device
select the tag Locked from BMS menu (Ctrl+L) or click the red “LOCKED” button in the top-right corner
of the window.
The window Enter password appears. The password is written as a serial number on the BMS you have
purchased.
Once you unlock the BMS, you get a permission to change the original settings on the device. The sign in
the right top corner should change to .
9 www.rec-bms.com
BMS MASTER CONTROL MANUAL
Data logging:
All parameters of the BMS can constantly be monitored on the right side of the screen. To see the
individual cell voltage, Cell resistance, package and BMS temperature the Logging window should be
chosen. To record and save the data you collect during an operation (charging, testing, etc.) choose the
File and set the Time interval you want BMS to save. When the Time interval is set to 00:00:00 the
software logs the data with its maximum achievable speed. By pressing the “Start” button you start the
logging, to stop recording, just press the button “Stop”.
10 www.rec-bms.com
BMS MASTER CONTROL MANUAL
Service Instructions
Additional Service Parameters are available in BMS tab under Communicate. Additional instructions and
custom made parameter instructions are described in the individual BMS user manual.
A new window pops-up. BMS receiver address has to be filled-in first. Read and Write instruction are
possible. When the parameter should be read from the BMS a question mark should follow 4-letter
instruction (e.g. VMAX?). If the parameter should be changed a new parameter value should follow the
instruction + a single space (e.g. VMAX 3.95). »Query« button answers with the parameter settings or
confirms the new value with »SET«. If the Run time window appears, repeat the instruction. The BMS is
busy with the measurement. »Send« is used in case when no respond is required.
11 www.rec-bms.com
BMS MASTER CONTROL MANUAL
Firmware upgrade
BMS firmware can be upgraded with RS-485 Cable and BMS Master Control software. When the BMS is
turned ON it waits for an instruction for firmware update for the first 0.5 s. Then it jumps to the normal
mode of operation. When a firmware upgrade should be done a “Firmware upgrade” option should be
chosen in the “BMS” menu.
A new firmware binary file should be selected from the “Select binary flash file” window.
12 www.rec-bms.com
BMS MASTER CONTROL MANUAL
A new window pops-up with Bootloader status. BMS should be turned OFF and ON to start the new
firmware upgrade. When the firmware is downloaded to the BMS, it should not be turned OFF! When
the new firmware is updated the BMS restarts on its own.
13 www.rec-bms.com