Frequency Response For Control System Analysis - GATE Study Material in PDF
Frequency Response For Control System Analysis - GATE Study Material in PDF
Up till now, we were dealing with the Time Response of these systems. However, the
properties and parameters of a system can also be measured using Frequency
Response. The magnitude and phase relation between the sinusoidal input and
steady state output of the system is known as the Frequency Response of the System.
Using frequency response method is advantageous due to its ease of use and accuracy
of measurements. The frequency response is generally recommended for systems
having smaller time constants. For large time constant circuit, the frequency output
is very small and time required for computation increase excessively.
You can download GATE notes in PDF for reference and revision later. Also
useful for other exams like IES, DRDO, BSNL, BARC etc. Before you begin
however, you need to be familiar with some topics.
Recommended Reading –
C(s) ω2n
=
R(s) s2 +2ξωn s+ω2n
C ω2
T(jω) = (jω) = (jω)2
R +2ξωn (jω)+ω2n
ω2n
= 2 2
ωn −ω +j(2ξωn ω)
1
T(jω) = ω 2 ω
1−(ω ) +j2ξ(ω )
n n
ω
Let = u (normalized frequency)
ωn
1
T(jω) =
1−u2 +j2ξu
2|Page
Now, if we apply sinusoidal input to second order closed loop transfer function it
would be shown as below
Now, if input to an LTI system is sinusoidal then output is also sinusoidal but with
some change in magnitude and phase.
B = A|T(jω)| = AM (M = |T(jω)|)
ϕ2 = ϕ1 + ∠T(jω) = ϕ1 + ϕ (∠T(jω) = ϕ)
1
T(jω) =
1−u2 +j2ξu
1 2ξu
M= , ϕ = − tan−1 ( )
√(1−u2 )2 +(2ξu)2 1−u2
For u = 0; M = 1, ϕ = 0
1
u = 1; M = , ϕ = −90°
2ξ
u = ∞; M = 0, ϕ = −180°
The frequency response of the system will be plotted in the two curves:
3|Page
In the above plots, Mr = Resonant Peak, ur = Normalized resonant frequency,
ϕr=Resonant phase
It is calculated
dm
Using | =0
du u=ur
ωr
= ur = √1 − 2ξ2
ωn
ωr = ωn √1 − 2ξ2
4|Page
1−2ξ2
ϕr = − tan−1 [√ ]
ξ
1
Mr = |M|u=ur =
2ξ√1−ξ2
1 − ξ2 √1 − 2ξ2
3. ϕ = − tan −1
[√ ] ϕr = − tan−1 [ ]
ξ ξ
C(s) 81
=
R(s) s2 +6s+81
If we compare the given transfer function with standard second order transfer
function, we get
ω2n = 81, ωn = 9
2ξωn = 6
6 1
ξ= = = 0.33
2×ωn 3
ωr = ωn √1 − 2ξ2
2
= 9√1 − = 3√7
9
ωR = 7.94 rad/sec
1 3 3×3
Mr = = =
2ξ√1−ξ2 2√1−
1 2√8
9
Mr = 1.591
√1−2ξ2
ϕr = − tan−1
ξ
= − tan−1 √7
= − 69.3°
Example 2: The step response of a standard second order system having unity
feedback is given as follows.
6|Page
Now, if the input to system is changed to sinusoidal, find the maximum value of
output with respect to frequency.
Solution:
−ξπ
[ ]
√1−ξ2
Mp = e
−ξπ
[ ]
e 1−ξ2 = 0.35
−ξπ
= ln(0.35) = −1.05
√1−ξ2
ξπ
= 1.05
√1−ξ2
ξ2
= 0.10638
1−ξ2
ξ2 (1.10638) = 0.10638
ξ2 = 0.096
ξ = 0.31
7|Page
1
Mr =
2ξ√1−ξ2
1
=
√2×0.31√1−(0.31)2
Mr = 1.6965
So, we studied the basic concepts and significance of frequency response. Next we
will look in to different plots with respect to frequency response and their use in
stability analysis.