0% found this document useful (0 votes)
106 views

Punching Shear Check - D

This document contains information about the design of two reinforced concrete columns. The first column has a diameter of 650mm, reinforcement of 113mm^2, and is designed to resist a factored shear force of 4823kN. The second column has a smaller diameter of 500mm, and is designed to resist a factored shear force of 2810kN, which does not exceed the punching shear limit. The third column is located at an edge with a vertical pipe penetration, has a larger diameter of 500mm, and is designed to resist a factored shear force of 560kN.

Uploaded by

johan.hafiz6926
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views

Punching Shear Check - D

This document contains information about the design of two reinforced concrete columns. The first column has a diameter of 650mm, reinforcement of 113mm^2, and is designed to resist a factored shear force of 4823kN. The second column has a smaller diameter of 500mm, and is designed to resist a factored shear force of 2810kN, which does not exceed the punching shear limit. The third column is located at an edge with a vertical pipe penetration, has a larger diameter of 500mm, and is designed to resist a factored shear force of 560kN.

Uploaded by

johan.hafiz6926
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 28

Column location GF grid J/4

u 4200 mm
D 650 mm
cover 50 mm
dom 600 mm
f'c 50 Mpa
P/A 1.3 MPa
x (smallest) 300 mm
y (largest) 600 mm
bh (ratio of y & x) = y/x 2.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 600 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.40 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.30 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 75.45 kNm AS3600 Cl 10.1.2
M*v from RAPT 0.00 kNm with 100% column stiffness
M*v = larger of the 2 above = 75 kNm
V* 5030 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 7041 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 9892 kN AS3600 Eqnt 9.2.3(2)
Vuo 7041 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 0 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 6891 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 7770 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 11680 kN < Vumax 16482 kN AS3600 Eqnt 9.2.4(5)
Asw 113 mm2
s 250 mm
y1 500 mm

Vu 6891 kN

Vu 6891
F 0.7
FVu 4823 kN Upper limit to Punching shear is exdceeded
e along or // to x axis
-4.1 %
Column location GF grid G/3

u 3600 mm
D 500 mm
cover 50 mm
dom 450 mm
f'c 40 Mpa
P/A 1.3 MPa
x (smallest) 300 mm
y (largest) 600 mm
bh (ratio of y & x) = y/x 2.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 600 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.15 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.30 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 33.00 kNm AS3600 Cl 10.1.2
M*v from RAPT 0.00 kNm with 100% column stiffness
M*v = larger of the 2 above = 33 kNm
V* 2200 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 4115 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 5755 kN AS3600 Eqnt 9.2.3(2)
Vuo 4115 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 0 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 4015 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 4594 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 6906 kN < Vumax 9745 kN AS3600 Eqnt 9.2.4(5)
Asw 113 mm2
s 250 mm
y1 500 mm

Vu 4015 kN

Vu 4015
F 0.7
FVu 2810 kN Upper limit to Punching shear not exceeded
e along or // to x axis
27.7 %
Column location L1 edge columns with vertical pipe peno

u 1350 mm
D 500 mm
cover 50 mm
dom 450 mm
f'c 40 Mpa
P/A 0.7 MPa
x (smallest) 300 mm
y (largest) 600 mm
bh (ratio of y & x) = y/x 2.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 300 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.15 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.60 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 16.80 kNm AS3600 Cl 10.1.2
M*v from RAPT 35.00 kNm with 100% column stiffness
M*v = larger of the 2 above = 35 kNm
V* 560 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 1434 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 2049 kN AS3600 Eqnt 9.2.3(2)
Vuo 1434 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 0 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 1330 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 1172 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 1761 kN < Vumax 2485 kN AS3600 Eqnt 9.2.4(5)
Asw 113 mm2
s 250 mm
y1 500 mm

Vu 1330 kN

Vu 1330
F 0.7
FVu 931 kN Upper limit to Punching shear not exceeded
e along or // to x axis
66.3 %
Column location L1 grid H/4

u 4241 mm
D 500 mm
cover 50 mm
dom 450 mm
f'c 40 Mpa
P/A 0.7 MPa
x (smallest) 450 mm
y (largest) 450 mm
bh (ratio of y & x) = y/x 1.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 450 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.15 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.45 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 81.00 kNm AS3600 Cl 10.1.2
M*v from RAPT 410.00 kNm with 100% column stiffness
M*v = larger of the 2 above = 410 kNm
V* 3600 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 4505 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 6436 kN AS3600 Eqnt 9.2.3(2)
Vuo 4505 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 1 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 3470 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 2465 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 7396 kN < Vumax 7396 kN AS3600 Eqnt 9.2.4(5)
Asw 200 mm2
s 100 mm
y1 500 mm

Vu 7396 kN

Vu 7396
F 0.7
FVu 5177 kN Upper limit to Punching shear not exceeded
e along or // to x axis
43.8 %
Column location L1 grid D/4

u 3600 mm
D 500 mm
cover 50 mm
dom 450 mm
f'c 40 Mpa
P/A 1.3 MPa
x (smallest) 300 mm
y (largest) 600 mm
bh (ratio of y & x) = y/x 2.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 300 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.15 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.30 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 50.40 kNm AS3600 Cl 10.1.2
M*v from RAPT 150.00 kNm with 100% column stiffness
M*v = larger of the 2 above = 150 kNm
V* 3360 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 4115 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 5755 kN AS3600 Eqnt 9.2.3(2)
Vuo 4115 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 1 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 3582 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 2609 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 5534 kN < Vumax 5534 kN AS3600 Eqnt 9.2.4(5)
Asw 113 mm2
s 100 mm
y1 500 mm

Vu 5534 kN

Vu 5534
F 0.7
FVu 3874 kN Upper limit to Punching shear not exceeded
e along or // to x axis
15.3 %
Column location L1 grid F/4

u 3600 mm
D 500 mm
cover 50 mm
dom 450 mm
f'c 40 Mpa
P/A 1.3 MPa
x (smallest) 300 mm
y (largest) 600 mm
bh (ratio of y & x) = y/x 2.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 300 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.15 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.30 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 37.50 kNm AS3600 Cl 10.1.2
M*v from RAPT 100 kNm with 100% column stiffness
M*v = larger of the 2 above = 100 kNm
V* 2500 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 4115 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 5755 kN AS3600 Eqnt 9.2.3(2)
Vuo 4115 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 1 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 3631 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 2744 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 4125 kN < Vumax 5820 kN AS3600 Eqnt 9.2.4(5)
Asw 113 mm2
s 250 mm
y1 500 mm

Vu 4125 kN

Vu 4125
F 0.7
FVu 2887 kN Upper limit to Punching shear not exceeded
e along or // to x axis
15.5 %
Column location L1 grid J/4

u 4000 mm
D 600 mm
cover 50 mm
dom 550 mm
f'c 40 Mpa
P/A 1.3 MPa
x (smallest) 300 mm
y (largest) 600 mm
bh (ratio of y & x) = y/x 2.0
dim. Of the critical shear perimeter measured // to the direction of M*v , a 300 mm (Also refer AS3600 Fig. 9.2.1 (B)
fcv 2.15 MPa AS3600 Cl. 9.2.3
Overall depth of Col. In the plane of B. Moment 0.30 m --> Eg. About y-y axis, My* -> d = eff. depth measure along or // to x axis
Min M* 64.50 kNm AS3600 Cl 10.1.2
M*v from RAPT 0.00 kNm with 100% column stiffness
M*v = larger of the 2 above = 65 kNm
V* 4300 kN
Cl.9.2.3 Ultimate shear strength where M*v = 0
Shear head 0 (1 = Yes, 0 = No)
Vuo (without shear head) 5589 kN AS3600 Eqnt 9.2.3(1)
Vuo (with shear head) 7815 kN AS3600 Eqnt 9.2.3(2)
Vuo 5589 kN
Cl.9.2.4 Ultimate shear strength where M*v is not 0
Ligs 1 (1 = Yes, 0 = No)
(a) No Closed ligs:
Vu = Vuo/[1+uM*v/(8V*adom)] 5346 kN AS3600 Eqnt 9.2.4(1)

Closed ligs provided:


(b) AS3600 Eqnt 9.2.4(2)_Torsion strip
Vu.min= 1.2Vuo/[1+uM*v/(2V*a2)] 5030 kN

Vu= Vu.min[(Asw/s)/(0.2y1/fsy.f)]^0.5................AS3600 Eqnt 9.2.4(4) 7562 kN < Vumax 10670 kN AS3600 Eqnt 9.2.4(5)
Asw 113 mm2
s 250 mm
y1 500 mm

Vu 7562 kN

Vu 7562
F 0.7
FVu 5293 kN Upper limit to Punching shear not exceeded
e along or // to x axis
23.1 %