You are on page 1/ 26

Hardware Siemens

Hardware

Contents
1 Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 CPCI boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 Frames. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.4 Peripheral Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.5 Corresponding Products (Obsolete. Always use Release Notes for most recent info.). 5
1.6 Hardware Architecture Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.7 HD Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2 DSCXL2 server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.1 Hardware Variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.2 LED and OLED Displays/Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.3 Front Panel Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.3.1 VGA Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.3.2 USB Host Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.3.3 LAN Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.3.4 USB Device (Slave) Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.4 Backplane Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.5 IOn-Board Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.6 Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.7 Backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3 HDTR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.1 Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.2 Cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

1
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens Hardware

Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

2
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Hardware Siemens

1 Hardware

1.1 CPCI boards


Boards Not supported Supported
SF2X8 X
HD/CF X
DSCXL X
DSCXL2 X
MCM X
RTM X
ACPCI / DCPCI X

1.2 Devices
HD / MO / CF Not supported Supported Capacity
3 1/2 HD SCSI X 60 GB
3 1/2 HD IDE X 40 GB
2 1/2 HD IDE X 60 GB
3 1/2 MO SCSI X 1,3 GB
3 1/2 MO IDE X 1,3 GB
CF-board X 2,0 GB
2 1/2 HD SATA X 250 GB

1.3 Frames
Frames Not supported Conversion Supported
to CPCI-St.
80CXE (Also known as HiPath 4300) X
600 ECS (Also known as HiPath 4500) X X
CPCI X

3
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens Hardware

1.4 Peripheral Boards


Boards

Not supported Q-number Replacements Q-Number


boards
SLMA Q2141-X SLMAE Q2225-X

4
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Hardware Siemens

1.5 Corresponding Products (Obsolete. Always use Release Notes for most recent info.)
Application / Product Required version
Device, Adapters and Gateways
OpenStage HFA > V2 R6.5.0
OpenStage SIP > V2 R2.30.0
OpenStage T > V2 R0.2.0
optiPoint 500
optiPoint 4x0 CorNet IP > V2 R0.57.1 HFA / V7 R6.3.0 SIP
AP 1120 CorNet IP > V5 R2.69.0
Mediatrix 41xx > V5.0.28.229
Mediatrix 44xx > V2.0.10.185
Mediatrix 1204
Mediatrix 36xx
OpenScape Personal Edition HFA > V3
OpenScape Personal Edition SIP > V3
LifeSize Room / Team / Express
IP Networking
OpenScape Voice V4 R1 / V5 R0 SIP Q V2
HiPath 3000 V8 SIP Q V2
HiPath 4000 V2.0 CorNet IP
HiPath 4000 V3.0 SIP Q V1
HiPath 4000 V4 and V5 SIP Q V2
TDM Networking
HiPath 4000 V2.0 / V3.0 / V4 / V5
HiPath 3000 V8
Applications
OpenScape 4000 Manager V6
OpenScape UC Application V4 R0
HiPath Fault Management V4
HiPath User Management V2
HiPath QoS Management V1
OpenScape ComAssistant V2.0

5
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens Hardware

Application / Product Required version


OpenScape Deployment Service V3
OpenScape Xpressions V5 / V6 native SIP for Conferencing,
CorNet IP for Messaging,
ACL-C/CSTA.ASN1 for
Call Control
OpenScape Contact Center V8
HiPath Trading V3
OpenScape Xpret V4
HiPath CAP V3.0
HiPath DTB V9.0
Attendant Suite
AC Win IP V1 R4.2.0 & V2 R4.1.0
BLF-Win V3
DS-Win V4
OpenScape Alarm Response V3
Professional
Mobility
HiPath Cordless E V3.0 R3.24.0 CV399
HiPath Cordless IP V1
OpenScape MobileConnect V3
optiPoint WL2 professional > V1 R3.10504.0

Client

Internet-Explorer Java
Windows 2000 IE6.0 1.6.0_01, 1.6.0_02, 1.6.0_07, 1.6.0_11,
1.6.0_23, 1.6.0_24
Windows 2003 Server IE6.0, IE7.0, IE8.0 1.6.0_01, 1.6.0_02, 1.6.0_07, 1.6.0_11,
1.6.0_23, 1.6.0_24
Windows XP IE6.0, IE7.0, IE8.0 1.6.0_01, 1.6.0_02, 1.6.0_07, 1.6.0_11,
1.6.0_23, 1.6.0_24
Windows Vista IE7.0, IE8.0 1.6.0_23, 1.6.0_24
Windows 7 IE8.0 1.6.0_23, 1.6.0_24

6
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Hardware Siemens

1.6 Hardware Architecture Table


+------------------------------------------------------------------+
| DB-Layout : S up to 4000 digital Subscriber |
| M up to 8000 digital Subscriber |
| L up to 12000 digital Subscriber |
+---------+----+-----------+ | +-------+-----------+---------------+
| ARCHI- | | | | | | MEMORY | |
| TECTURE |ARCH| | | | PROCE |WITH-|WITH | USAGE/ |
| (ARCH) |-TYP| TITLE | V | -SSOR | OUT | UW7 | VERWENDUNG |
+---------+----+-----------+---+-------+-----+-----+---------------+
| 4000 | 01 | CPI-MONO | S | DSCXL | --- |1024 | CUSTOMER/LAB |
+---------+----+-----------+---+-------+-----+-----+---------------+
| 4000 | 06 | CPI-SWU | L | DSCXL | --- |1024 | CUSTOMER/LAB |
| | | -ADS | | DSCXL | --- |1024 | CUSTOMER/LAB |
| 4000 | 07 | CPI-SWU | L | DSCXL | --- |1024 | CUSTOMER/LAB |
| | | SIMPLEX | | | | | |
| | | -ADS | | DSCXL | --- |1024 | CUSTOMER/LAB |
+---------+----+-----------+---+-------+-----+-----+---------------+
+------------------------------------------------------------------+
| ARCHITECTURE = 4000 ; |
| ARCHITECTURE-TYPE = 01; FOR CUSTOMER AND LAB
| SELECTION = ; APE ONLY |
| BAPPL = BSMONO ; |
| DBAPPL = DBSMALL ; |
| ASSEMBLY = CPCI ; |
| CLASS = H600 ; |
| OPMODE = SIMPLEX ; |
| SYSTEM = ; |
| DIMEN = SMALL ; |
| RESSWUDB = N ; |
| LOCATION = CUSTOMER; |
| APPLICATION = "BSMONO ",SWU,BP; |
| APPLICATION = "DBSMALL ",SWU,BP; |
| APPLICATION = "POOL1 ",SWU,BP; |
| APPLICATION = "I-POOL1 ",SWU,BP; |
| APPLICATION = "BS-PCIMP",SWU,BP; |

7
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens Hardware

| APPLICATION = "BSMONO ",APE,BP; |


| APPLICATION = "DBSMALL ",APE,BP; |
| APPLICATION = "POOL1 ",APE,BP; |
| APPLICATION = "I-POOL1 ",APE,BP; |
| APPLICATION = "BS-PCIMP",APE,BP; |
+------------------------------------------------------------------+
| ARCHITECTURE = 4000 ; |
| ARCHITECTURE-TYPE = 06; FOR CUSTOMER AND LAB
| SELECTION = ; |
| BAPPL = BSDUAL ; |
| DBAPPL = DBLARGE ; |
| ASSEMBLY = CPCI ; |
| CLASS = H600 ; |
| OPMODE = DUPLEX ; |
| SYSTEM = ; |
| DIMEN = LARGE ; |
| RESSWUDB = N ; |
| LOCATION = CUSTOMER; |
| APPLICATION = "BSDUAL ",SWU,BP; |
| APPLICATION = "DBLARGE ",SWU,BP; |
| APPLICATION = "COMLAN ",SWU,BP; |
| APPLICATION = "POOL1 ",SWU,BP; |
| APPLICATION = "I-POOL1 ",SWU,BP; |
| APPLICATION = "BSMONO ",APE,BP; |
| APPLICATION = "DBLARGE ",APE,BP; |
| APPLICATION = "POOL1 ",APE,BP; |
| APPLICATION = "I-POOL1 ",APE,BP; |
| APPLICATION = "BS-PCIMP",APE,BP; |
+------------------------------------------------------------------+
| ARCHITECTURE = 4000 ; |
| ARCHITECTURE-TYPE = 07; FOR CUSTOMER AND LAB |
| SELECTION = ; |
| BAPPL = BSDUAL ; |
| DBAPPL = DBLARGE ; |
| ASSEMBLY = CPCI ; |
| CLASS = H600 ; |
| OPMODE = SIMPLEX ; |

8
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Hardware Siemens

| SYSTEM = ; |
| DIMEN = LARGE ; |
| RESSWUDB = N ; |
| LOCATION = CUSTOMER; |
| APPLICATION = "BSDUAL ",SWU,BP; |
| APPLICATION = "DBLARGE ",SWU,BP; |
| APPLICATION = "COMLAN ",SWU,BP; |
| APPLICATION = "POOL1 ",SWU,BP; |
| APPLICATION = "I-POOL1 ",SWU,BP; |
| APPLICATION = "BSMONO ",APE,BP; |
| APPLICATION = "DBLARGE ",APE,BP; |
| APPLICATION = "POOL1 ",APE,BP; |
| APPLICATION = "I-POOL1 ",APE,BP; |
| APPLICATION = "BS-PCIMP",APE,BP; |
+------------------------------------------------------------------+

9
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens Hardware

1.7 HD Layout
Upgrades to HiPath 4000 V6 must use the Reference Center process for database conversion.
A Field upgrade, which was possible from HiPath 4000 V4 to V5, is not possible with HiPath
4000 V6.
HiPath 4000 RMX Controllers:
ADD-DCSM:A1,1,HD,"STDH6";
ADD-DASM:A1,1,7200&1600&2400&1120&16384&7200&9868,
4096&4096&4096&4096&4096&4096&4096;
ADD-DLSM:A1,1,E,":PDS:";
ADD-DLSM:A1,1,F,":DBDA:"&":DBD:"&":TMD:"&":PAS:"&":AMD:"&":DMP:";
ADD-DLSM:A1,1,G,":CGD:"; Controller 1 is a virtual hard disk. It is the
ADD-DLSM:A1,1,H,":DMS:"&":DSY:"; primary RMX boot device. In V6 it is also referred
ADD-DLSM:A1,1,I,":SCR:"; to as Virtual Hard Disk 1 (VHD1)
ADD-DLSM:A1,1,J,":GLA:";
ADD-DLSM:A1,1,K,":DIAG:";

ADD-DCSM:A1,4,HD,"STDH6";
ADD-DASM:A1,4,7200&1600&2400&1120&16384&7200&9868,
4096&4096&4096&4096&4096&4096&4096;
ADD-DLSM:A1,4,E,":PDS:";
ADD-DLSM:A1,4,F,":DBDA:"&":DBD:"&":TMD:"&":PAS:"&":AMD:"&":DMP:";
ADD-DLSM:A1,4,G,":CGD:"; Controller 4 is new to HiPath 4000 V6.
ADD-DLSM:A1,4,H,":DMS:"&":DSY:"; It is also a virtual hard disk. The RMX
ADD-DLSM:A1,4,I,":MOD-SCR:"; side of this controller is not used;
ADD-DLSM:A1,4,J,":GLA:"; however, the administrative side of
ADD-DLSM:A1,4,K,":DIAG:"; this hard disk is used to store HBR
Data Backups. HBR Data Backups cannot
ADD-DCSM:A1,6,HD,"STDH6"; be copied to USB.
ADD-DASM:A1,6,7200&1600&2400&1120&16384&7200&9868,
4096&4096&4096&4096&4096&4096&4096;
ADD-DLSM:A1,6,E,":PDS:";
ADD-DLSM:A1,6,F,":DBDA:"&":DBD:"&":TMD:"&":PAS:"&":AMD:"&":DMP:";
ADD-DLSM:A1,6,G,":CGD:"; Controller 6 is also a virtual hard disk. It is
ADD-DLSM:A1,6,H,":DMS:"&":DSY:"; the secondary RMX boot device. In V6 it is referred
ADD-DLSM:A1,6,I,":MOD-SCR:"; to as Virtual Hard Disk 2 (VHD2). VHD2 replaces
ADD-DLSM:A1,6,J,":GLA:"; the Compact Flash card. It works similarly to a CF.
ADD-DLSM:A1,6,K,":DIAG:"; In HBR, the copy from Controller 1 to Controller 6
is now called VHD1 -> VHD2 backup.

10
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
DSCXL2 Server Siemens

2 DSCXL2 server
The DSCXL2 is the server controlling SuSE Linux Enterprise Server 11 SP 1 and the HiPath
4000 V6 application. One DSCXL2 server is needed for a Simplex installation, and two
DSCXL2 servers (Primary and Secondary) are required for a Duplex installation.See Fig. 2-1.

Warning
7 The DSCXL2 server should never be removed without (1) deactivating the HiPath
4000 V6 virtual hard disk(s) using AMO DSSM, and (2) using the HiPath 4000 Portal
to Shutdown the entire server.

Fig. 2-1 DSCXL2 server

2.1 Hardware Variants


S30122-K7732-X (with 2 x 2 GB memory module + HD)
The DSCXL2 server has a maximum capacity of 4 GB RAM.

11
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens DSCXL2 Server

2.2 LED and OLED Displays/Keys


The front side of the board features includes one OLED display, two keys, two LEDs for
DSCXL2 status, one LED for the LAN interface to the RTM board and one LED for HD activity
with the following properties:

VGA Monitor

Host
Host

8 LAN Interfaces

USB1/Service PC

Reset

Fig. 2-2 DSCXL2 front panel

12
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
DSCXL2 Server Siemens

DSCXL2 display Properties


OLED display Indicates the current status of the DSCXL2
Page 1:
HiPath 4000 (only 1 s).
Page 2:
Status ADP and CC in "7-segment display" notation

Page 3:
Host-Status (CPU and memory load and FAN speed)

Page 4:
Kernel version and uptime of the system

Page 5:
Server-IP (eth0), MAC-address (eth0)

Page 6:
Portal IP address, Assistant IP Address

Page 7:
Optional error output
Table 2-1 LED and OLED displays/keys

13
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens DSCXL2 Server

DSCXL2 display Properties


RUN LED green CPU is active
Fail LED yellow CPU error
HD ACTIVE LED green HD activity
Keys
Display ON Shows the status of board
Reset Button Manual reset for DSCXL2 (The reset button is recessed behind
the front panel to avoid pushing the button by mistake.
Table 2-1 LED and OLED displays/keys

14
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
DSCXL2 Server Siemens

2.3 Front Panel Interfaces

2.3.1 VGA Interface


VGA interface is available for maintenance support. The DSCXL2 is a server which may peri-
odically require a monitor, USB keyboard, and USB mousefor maintenance purposes. The
VGA monitor, keyboard and mouse are typically referred to as the servers console.

2.3.2 USB Host Interface


Two USB host slots (USB 2.0 high speed) are available at the front panel.

2.3.3 LAN Interface


Eight GigE interfaces on the front panel for redundant configuration. These ethernet interfaces
are freely assignable; however, the installation process includes best practice recommenda-
tions.
The LAN interfaces to the front panel supports IPv4 and IPv6, jumbo frames (9kB), MSI/MSI-X
and IO Virtualization (VT-c/VMDq).

LAN displays LED on LED off LED flashing


LINK/ACT green Connection No connection Transferring or receiving signal
SPEED green 100 Mbps 10 Mbps

The LEDs for the LAN interfaces on the front panel are integrated in the RJ45 receptacles.

2.3.4 USB Device (Slave) Interface


A USB slave interface (labeled USB1) is available for management. This interface is used to
connect a service PC with a USB host-to-device-cable. There is no need to configure IP ad-
dresses. The procedure to connect a Service PC is described in Module 10.
Number of USB slaves: 1

2.4 Backplane Interface


RTM Interface
One GigE interface on J4 connector for RTM connection (only pins for 100 Mbit are
provided on the J4 connector).
For the LAN interface, routed to the backplane, only one LED is visible on the front
panel, displaying both, link and activity. This LED is green.

15
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens DSCXL2 Server

Alarm Interface
Three dedicated signals (NAL, UAL, ALUM) are used to control three alarm relays, lo-
cated on the shelf management controller board MCU. These signals are routed only
to slot1 of the HiPath 4000 shelf, and are connected to the Controller.
Partner Interface
The CPU blade can be used in a redundant environment. The signaling of the actual
status of each blade is done via the Partner Interface. The partner interface is work-
ing only for slot 1 (system slot) and slot 5 of the HiPath 4000 basic shelf.
I2C Interface
The devices connected to the external I2C bus of the C (Temperature/Fan monitor
and controller) can be accessed from the host system.
FAN Emergency Switch
The HiPath 4000 Basic shelf is a full redundant system. Nevertheless the fan-control-
ler, located on the MCM is a single point of failure. To protect the system if the fan con-
troller will not work properly the DSCXL2 is equipped with a emergency fan switch.
This switch will turn on all fans on full speed if a critical temperature is reached.

2.5 IOn-Board Interface


It is possible to install a SATA 2.5 hard disk or a 2.5 Solid State Disk module as mass storage
device on the secondary DSCXL2 server; however, the Primary server uses an externally-con-
nected Hard Disk Tray (HDTR) to house up to two SATA hard disks. The HDTR provides easy
access to the two system hard disks (including RAID).

2.6 Power Supply


The board can plugged in and unplugged while the system is running. The power supply volt-
ages (+12 V, +5 V and +3.3 V) are supplied through the backplane. DC/DC converter generates
the individual power supply voltages needed for the various circuits on the DSCXL2 server.

16
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
DSCXL2 Server Siemens

2.7 Backplane

Fig. 2-3 Backplane connectors

The Secondary DSCXL2 server supports an onboard SATA hard disk.

17
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens DSCXL2 Server

Block Diagram: HiPath 4000 V6

18
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
DSCXL2 Server Siemens

LAN Interfaces: DSCXL2

19
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens DSCXL2 Server

20
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Hard Disk Tray Siemens

3 HDTR

3.1 Frame
The HDTR (Hard Disk Tray) board is equipped with two SATA slots for 2.5 hard disks.
The HDTR will be mounted in slot 3 of the cPCI only.
With two hard disks mounted, the system can use the HDTR as a soft-RAID.

7 Never eject a hard disk when the HDTR red LED of the slot is flashing.

Each tray of the HDTR has its own LEDs


LED Meaning
No LEDs is on Tray is empty (no hard disk inside).
Blue light up and no RED Hard disk is inside but is not used by raid.
light blinking
Blue light up and RED light is Hard disk is in HDTR, in use, and must not be removed.
blinking

21
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens Hard Disk Tray

7 For management and the replacement procedures, use the HiPath Portal.

3.2 Cabling
The SATA cable which is coming from the top slot of the Hard Disk Tray should be connected
to the first SATA connector next to the power plug on the SATA module (in the picture below it
is marked with '1').
The second SATA cable (which is coming from the bottom slot of the HD Tray) should be con-
nected to the second SATA connector on the fringes of the SATA module (in the picture below
it is marked with '2').

22
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Hard Disk Tray Siemens

Simplex

Duplex
Secondary Hard Disk resides here

The Secondary server exclusively uses its own onboard hard disk.

23
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens Hard Disk Tray

24
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Abbreviations Siemens

Abbreviations

This table shows some important abbreviations.

Abbreviation Definition

T
TDM Time Division Multiplexing

25
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG
Siemens Abbreviations

26
EN4460EN00EN_0005
Siemens Enterprise Communications GmbH & Co. KG 2011. All rights reserved.
Siemens Enterprise Communications GmbH & Co. KG is a trademark licensee of Siemens AG