0% found this document useful (0 votes)
396 views4 pages

E5119 - DV DRV 06 16

This document summarizes needle valves with and without reverse flow check that are directly-acting and inline mounted up to 350 bar pressure. The valves are used to regulate flow speeds, adjust flows, release pressure from accumulators, and dampen hydraulic circuits. They come in five sizes up to 180 l/min flow with drop forged housings, locking knobs, and optional zinc or stainless steel materials. Performance curves show the pressure drop depending on the flow rate and valve setting.

Uploaded by

ardossantos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
396 views4 pages

E5119 - DV DRV 06 16

This document summarizes needle valves with and without reverse flow check that are directly-acting and inline mounted up to 350 bar pressure. The valves are used to regulate flow speeds, adjust flows, release pressure from accumulators, and dampen hydraulic circuits. They come in five sizes up to 180 l/min flow with drop forged housings, locking knobs, and optional zinc or stainless steel materials. Performance curves show the pressure drop depending on the flow rate and valve setting.

Uploaded by

ardossantos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Needle Valves

with and without


Reverse Flow Check
Direct-Acting
Inline Mounted - 350 bar
Up to 180 l/min
Up to 350 bar DV, DRV 06 to 16
FUNCTION FEATURES
zz For regulating the speed of loads
zz For fine adjustment and shut-off of the flow
DV zz For system-related damping in hydraulic circuits
zz To release pressure from accumulator systems
zz As an emergency drain for lowering a load without a dead man's circuit
zz Spindle patented secured before complete loosening
zz An Allen set-screw locks the setting of the knob
zz Choice of five sizes ensures best possible adaptability to the system
zz Drop forged housings with high safety factor

DRV

SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal flow: DV, DRV-06 max. 20 l/min
DV, DRV-08 max. 50 l/min
DV, DRV-10 max. 60 l/min
DV, DRV-12 max. 90 l/min
DV, DRV-16 max. 180 l/min
Cracking pressure (on DRV): 0.5 bar
Media operating temperature range: min. -20 C to max. +100 C
Ambient temperature range: min. -20 C to max. +100 C
Operating fluid: Hydraulic oil to DIN 51524 Part 1 and 2
Viscosity range: min. 2.8 mm/s to max. 800 mm/s
The DV is an inline mounted flow
control valve which controls the flow by Filtration: Class 21/19/16 according to ISO 4406 or
adjusting the cross-section. The flow rate cleaner
is therefore dependent on the pressure MTTFd: 150 years (see "Conditions and
differential and viscosity. Starting with the instructions for valves" in brochure 5.300)
throttle spindle in the fully closed position, Installation: no orientation restrictions, preferably
the flow rate increases in accordance with horizontal
the appropriate curve as the control knob
Materials: Valve body: steel
is turned. The flow is controlled in both
directions. Piston: hardened and ground steel
The scale on the lower edge of the control Seals: FKM (standard)
knob enables accurate repeat setting. The Back-up rings: PTFE
DRV is a flow control valve in the same
Weight: DV 06 = 0.10 kg DRV 06 = 0.10 kg
E 5.119.10/06.15

design which also allows the same fine


flow adjustment, but in one direction only. DV 08 = 0.26 kg DRV 08 = 0.28 kg
Unrestricted flow in the reverse direction DV 10 = 0.38 kg DRV 10 = 0.41 kg
is via the built-in check valve (cracking DV 12 = 0.62 kg DRV 12 = 0.65 kg
pressure 0.5 bar). DV 16 = 1.04 kg DRV 16 = 1.14 kg

204
Standard models
MODEL CODE
Model code Part No.
DRV 08 01.X/0 DV-06-01.4/0 705002
Basic model DV-08-01.4/0 705014
DV = Needle valve DV-10-01.4/0 705026
DRV = Needle valve with reverse flow check
DV-12-01.4/0 705038
Nominal size DV-16-01.4/0 705050
06, 08, 10, 12, 16
DRV-06-01.4/0 705502
Type DRV-08-01.4/0 705514
01 = standard, housing zinc-plated DRV-10-01.4/0 705526
11 = housing zinc-plated, fine throttle spindle
DRV-12-01.4/0 705538
in stainless steel
12 = housing zinc-nickel coated (seawater-resistant), DRV-16-01.4/0 705550
fine throttle spindle in steel, Other models on request
with protective dome nut
- adjustment with tool , soldered Accessories
30 = housing stainless steel Panel mounting sets, nickel-plated, consisting of locking washer,
Other types on request disc and hex. nut
Series Size Part No.
(to be determined by manufacturer) 06 705309
Threaded connection 08 705310
0 = Whitworth thread, 10 705310
threaded connection Form X to DIN 3852 Part 2 12 705311
5 = NPT thread 16 705311
12 = UNF thread

E 5.119.10/06.15

205
PERFORMANCE
Pressure drop, dependent on flow rate DV-12-01.3/0 A B
DV=flow direction A B and B A
flow setting in turns
DRV=flow direction A B
1 2 3 4 5
Pressure differential p measured against flow rate Q, 100

measured at constant flow setting, = 53 mm/s and Toil = 36 C 90

80

Pressure differential p [bar]


70
DV-06-01.3/0 A B
60
6
flow setting in turns
50
0,5 1 1,5 2 2,5 3
100 7
40
8
90
30
80
Pressure differential p [bar]

20
70
3,5 10
60
0
50 0 10 20 30 40 50 60 70 80 90
Flow rate [l/min]
40 4
4,5
30 5

20 DV-16-01.3/0 A B
10 flow setting in turns
0 1 2 3 4 5 6 7
0 2 4 6 8 10 12 14 16 18 20 100

Flow rate [l/min] 90

80
Pressure differential p [bar]

8
70
DV-08-01.3/0 A B
60 9
flow setting in turns
50 10
1 2 3
100
40
90
4 30
80
Pressure differential p [bar]

5 20
70
6 10
60 7
0
50 0 20 40 60 80 100 120 140 160 180
Flow rate [l/min]
40

30

20

10

0
0 5 10 15 20 25 30 35 40 45 50
DRV-06-16 B A
Flow rate [l/min]

10

DV-10-01.3/0 A B
12

8
10
Pressure differential p [bar]

flow setting in turns


DR
DRV 08

DRV

1 2 3 4
100
DRV 06

6
90

80
Pressure differential p [bar]

5 4
70 16
DRV
60
2
50
6
40
0
7
30 0 20 40 60 80 100 120 140 160 180 200
Flow rate [l/min]
20

10

0
0 5 10 15 20 25 30 35 40 45 50 55 60
E 5.119.10/06.15

Flow rate [l/min]

206
DIMENSIONS
DV DRV
Type 01 30 11 12 Type 01 30 11 12

open

open
closed

closed
millimeter millimeter
subject to technical modifications subject to technical modifications

Size Threaded A B C SW E Size Threaded A B C SW E


connection connection
06 G 57 52.9 9 16 19 06 G 57 52.9 9 16 28.8
08 G 70.4 64.3 14.2 25 24 08 G 70.4 64.3 14.2 25 34
10 G 76.6 70.8 17.7 30 29 10 G 76.6 70.8 17.7 30 42
12 G 89.2 82.3 20 35 34 12 G 89.2 82.3 20 35 44
16 G 106.2 97.3 25.7 45 39 16 G 106.2 97.3 25.7 45 57

F G J SW1 SW2 X Weight [kg] F G J SW1 SW2 X Weight [kg]


38 25.2 Pg7 3 10 58.6 0.094 45 25.2 Pg7 3 10 58.6 0.103
48 30.5 Pg11 4 13 72.3 0.257 55 30.5 Pg11 4 13 72.3 0.277
58 30.5 Pg11 4 13 78.8 0.378 65 30.5 Pg11 4 13 78.8 0.407
68 38 Pg16 5 17 89.3 0.618 73 38 Pg16 5 17 89.3 0.644
78 38 Pg16 6 19 111.3 1.038 88 38 Pg16 6 19 111.3 1.139

NOTE
The information in this brochure relates to HYDAC Fluidtechnik GmbH
E 5.119.10/06.15

the operating conditions and applications


described. Justus-von-Liebig-Str.
For applications or operating conditions not D-66280 Sulzbach/Saar
described, please contact the relevant Tel: 0 68 97 / 509-01
technical department. Fax: 0 68 97 / 509-598
Subject to technical modifications. E-Mail: [email protected]

207