100% found this document useful (1 vote)
2K views

Holding Down Bolts Example

This document contains calculations for the pull-out capacity of holding down bolts for a project with job number 1 Atlantic Quay. It calculates the tension capacity of M20 grade 8.8 bolts, the pull-out resistance of concrete, and confirms the design satisfies the requirement that bolt tension capacity exceeds pull-out resistance. Key parameters calculated include bolt length, embedment depth, conical surface area, and design pull-out resistance per bolt of 218 kN.

Uploaded by

Marcelo Machado
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views

Holding Down Bolts Example

This document contains calculations for the pull-out capacity of holding down bolts for a project with job number 1 Atlantic Quay. It calculates the tension capacity of M20 grade 8.8 bolts, the pull-out resistance of concrete, and confirms the design satisfies the requirement that bolt tension capacity exceeds pull-out resistance. Key parameters calculated include bolt length, embedment depth, conical surface area, and design pull-out resistance per bolt of 218 kN.

Uploaded by

Marcelo Machado
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Project Job no.

Mott MacDonald Calcs for Start page no./Revision


1 Atlantic Quay 1
Broomielaw
Calcs by Calcs date Checked by Checked date Approved by Approved date
Glasgow G2 8JB, UK
M 27/10/2016

L_proj (Clear projection of bolt above nut)

t_was (Washer thickness) t_p (Base plate thickness)

t_gr (Thickness of bedding)

L_bolt (Overall length of bolts) Concrete

PULL-OUT CAPACITY OF HOLDING DOWN BOLTS


TEDDS calculation version 1.0.01
These calculations assume that there is no coexistent shear in the holding-down bolts.
Tension capacity of bolts
; Maximum tension force per bolt; Ft = 100.0 kN
; Try M20 (Grade 8.8); bolts; Pt = 110.3 kN ; dnut = 16 mm
Check Ft Pt ; Pass - Bolt tension capacity;

Pull-out resistance of concrete


;; Overall length of bolts; Lbolt = 600 mm
; Clear projection of bolt above nut; Lproj = 50 mm
;;; Thickness of washer, baseplate & grout; twas = 3 mm ; tp = 30 mm ; tgr = 50 mm
Depth of embedment; de = Lbolt - Lproj - dnut - twas - tp - tgr = 452 mm
From BCSA HDBolts document, effective conical surface area; for two bolts; Aec = 12825.9 cm2
Depth of embedment selected; de = 452 mm
Design spacing of bolts (c/c); Xccs = 300 mm
; Shear strength of concrete; vc = 0.34 N/mm2
Design pull-out resistance, per bolt; Ptc = Aec vc / 2 = 218.0 kN
Check Ft Ptc ; Pass - Concrete pull-out resistance
Bolts require adequate anchorage by suitably sized washer plates or equivalent under the bolt heads.
BS 5950: Part 1: 2000: Sections 4.13 & 6.6
'Holding down systems for steel stanchions' BCSA / Constrado 1980
;