Capacity Plus Configuration Guide 9.1
Capacity Plus Configuration Guide 9.1
Capacity Plus
Configuration Guide
October 2017
Introduction 2
1 Introduction
SmartPTT is a software package designed to manage communication between linear-extended and geographically-
distributed objects where it is necessary to facilitate voice and data transmission and dispatching of remote radio
SmartPTT allows users to connect to the Capacity Plus network repeaters directly over IP. This approach reduces
the amount of the MOTOTRBO equipment used in the system (radios functioning as control stations).
The following picture displays the scheme of the direct connection between SmartPTT radioserver and Capacity Plus
Here, SmartPTT Radioserver connects directly over IP to the Master repeater of the Capacity Plus network to receive
This guide describes how to configure the following system components to implement dispatch control system over
Repeaters
Radios
SmartPTT Radioserver
In this document we presume that the system is built based on the following hardware:
Three MOTOTRBO repeaters Master (Trunk), Slave (Trunk), Slave (Data Revert)
SmartPTT Dispatcher
SmartPTT Radioserver
Physical control stations are not displayed in SmartPTT Dispatcher, but are automatically controlled by the
radioserver.
Data control station is used for data transmission (ARS, GPS, telemetry requests, CSBK commands, text
messages). Dedicated data control station doesnt require sound device and can be connected via USB only. To
dedicate a control station to data transmission only, remove the Active check box at the Sound window under TX
Station in SmartPTT Radioserver Configurator. You can use multiple data control stations to balance workload
depending on the system capacity. All data control stations must have the same Radio ID equal to the ID of the
Voice control station must be connected to the radioserver by means of USB and audio cables.
There are two ways how to set Radio ID on voice control station:
1. To set Radio ID of the voice control station equal to ID of the virtual Capacity Plus control station specified in
SmartPTT Radioserver Configurator. In this case all voice control stations will belong to a single pool. The
radioserver will automatically select the available free control station to make a dispatcher voice call.
2. To set unique Radio IDs on all voice control stations. This can be useful if you need to assign a dedicated voice
control station to a specific dispatcher. Use Profiles in SmartPTT Radioserver Configurator to set up dispatcher
profiles to have a dedicated voice control station. Use the radioserver settings in the dispatcher console to
For dispatchers located within the Capacity Plus radio coverage it is recommended to use portable radios, not mobile
radios, to make outgoing voice calls to reduce the amount of radios connected to the radioserver. Mobile control
stations must be used to make outgoing voice calls from the dispatcher console located outside the Capacity Plus
radio coverage.
Voice call control station must be programmed with a channel for each talkgroup. So, the amount of channels
programmed for voice control station must equal the amount of used talkgroups. To assign channels to groups, use
1. Connect your device to the PC via a programming cable and launch MOTOTRBO CPS.
2. Switch on the device and check its settings by clicking the Read button on the menu bar.
3. In the View menu select Expert to gain access to all the setting parameters.
4. In the Device Information tab make sure that firmware version is no older than:
Note: It is recommended to use the same or compatible firmware versions for all MOTOTRBO equipment on the
same network.
5. To apply the changes in the settings, click Write (next to the Read button on the menu bar).
2. Select Peer in the Link Type field in the Network tab.Enter Master IP and UDP port. Set Ethernet IP,
carefully.
2. In the Contacts tab add subscriber groups to the contact list. Set unique Call ID for each group.
Members list.
4. Add Capacity Plus Voice Channel for Master repeater to Channel Pool. Set frequency pair of the trunk
repeater.
repeater.
6. Add the created voice channels to the Members list of Capacity Plus voice channels. Add the channel pool of
the Master (Trunk) repeater first (ID = 1-2), then add the channel pool of the Slave (Trunk) repeater (ID = 3-4).
8. In the Channels section create a trunk channel dedicated to GroupCall2 and do the following settings.
way:
1. In the Network tab in Forward to PC select Via USB just like in the TX control station settings.
2. In the Contacts tab, under Capacity Plus add as Private Call. Define a unique Call ID, which equals the Slot
3. Add Capacity Plus Voice Channel for Master repeater to Channel Pool. Set frequency pair of the trunk
repeater.
repeater.
5. Add the created voice channels to the Members list of Capacity Plus voice channels. Add the channel pool of
the Master (Trunk) repeater first (ID = 1-2), then add the channel pool of the Slave (Trunk) repeater (ID = 3-4).
6. In the Channels section create a trunk channel for the private call and do the following settings.
3. To send data packets deliberately via a Data Revert repeater, create a channel pool for slot 1 of Slave
(DataRevert) repeater.
5. Add the created voice channel pools to Capacity Plus voice channel list.
6. Add the created data channel pools to Capacity Plus data channel list.
convenience, so that the subscriber did not have to remember all the call ID's.
and data packets. Thus, data packets will be sent to the radioserver via a Data Revert repeater.
4 Programming Radioserver
SmartPTT implies direct connection to the repeaters operating in the Capacity Plus mode. Capacity Plus network
can contain up to 6 repeaters (up to 12 time-slots) for voice communication and up to 12 repeaters (up to 24 time-
slots) for data communication through revert channels. Several Capacity Plus systems can be connected to one
SmartPTT Radioserver.
It is necessary to create a virtual repeater and a virtual control station on SmartPTT Radioserver. TX Control Stations
are required for sending voice and data packets to the radio system.
2. To add a new Capacity Plus system right-click on Capacity Plus System in the setting tree of the Settings tab
Peer ID unique identifier of the virtual repeater in Capacity Plus. Make sure it does not match any other
Interface (host:port) network interface of the radioserver, which will be used for connection with the
Master repeater address (host:port) IP address and port of Capacity Plus Master repeater. Check the IP
Group Call Hang Time (ms) the time period during which a radio will talk back to a received call or
continue a transmitted Talkaround Group Call using the previously received or previously transmitted digital
group ID. After expiration of the Talkaround Group Call hang timer, the radio will transmit using the TX Contact
Private Call Hang Time (ms) the time period during which the radio keeps the Talkaround Private Call
since the channel is idle. After the hang timer expires, the radio transmits using the TX Contact Name
Emergency Call Hang Time (ms) the time period during which the radio keeps the Talkaround Emergency
Call setup after the user releases the Push-to-Talk (PTT) button. Until the hang time has run out only
To set up a virtual control station for Capacity Plus, click Capacity Plus System, select Capacity Plus 1 and then
Name the control station name. You cannot type more than 20 characters into this field.
Radio ID the unique radio identifier which is used during communication with this radio.
CAI Network CAI-Network identifier. It is recommended to use the default value of 12.
To set up talkgroups of the virtual control station, click Groups. These will be displayed in SmartPTT Dispatcher, so
First, add TX control station. To do it, right-click Stations, and add the new control station MOTOTRBO.
case it is 1.
All Calls channel is designed for All Calls, private calls and data communication.