0% found this document useful (0 votes)
97 views6 pages

SK3 16

The MSO-2000 series oscilloscopes offer various features for analyzing analog and digital signals: 1) They provide dual analog channels plus 16 digital channels or 4 analog channels plus 16 digital channels, with bandwidth options of 200MHz, 100MHz, or 70MHz. 2) Features include a high waveform update rate, long 10M memory depth, 38 automatic measurement functions, serial and parallel bus triggering and decoding, and digital filtering. 3) Models include the MSO-2000E with a 16-channel logic analyzer or the MSO-2000EA with a logic analyzer and dual-channel 25MHz arbitrary waveform generator.

Uploaded by

GermanilloZeta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views6 pages

SK3 16

The MSO-2000 series oscilloscopes offer various features for analyzing analog and digital signals: 1) They provide dual analog channels plus 16 digital channels or 4 analog channels plus 16 digital channels, with bandwidth options of 200MHz, 100MHz, or 70MHz. 2) Features include a high waveform update rate, long 10M memory depth, 38 automatic measurement functions, serial and parallel bus triggering and decoding, and digital filtering. 3) Models include the MSO-2000E with a 16-channel logic analyzer or the MSO-2000EA with a logic analyzer and dual-channel 25MHz arbitrary waveform generator.

Uploaded by

GermanilloZeta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

99 Washington Street

Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431

Visit us at www.TestEquipmentDepot.com
Economical and Multi-Functional MSO
The MSO-2000 series is a mixed-signal oscilloscope, which offers dual analog channels + 16 digital channels or 4 analog channels +
16 digital channels. The MSO-2000 series includes MSO-2000E and MSO-2000EA. MSO-2000E has a built-in 16-channel logic analyzer
and MSO-2000EA has a built-in 16-channel logic analyzer and a dual channel 25MHz arbitrary waveform generator. The entire series
features bandwidth selections of 200MHz, 100MH, and 70MHz. Dual analog channel models provide 1GSa/s real-time sampling rate
per channel; four analog channel models provide 1GSa/s maximum real-time sampling rate. The 8-inch 800*480 TFT LCD and the
minimum 1mV/div vertical range allow the MSO-2000 series to measure complex feeble signals and clearly display measurement results.

For analog channels, the MSO-2000 series provides 10M long memory for users to completely retrieve and analyze waveforms. Users,
based upon the application requirements, can select 1k, 10k, 100k, 1M or 10M memory depth. Short memory depth collocating with the
high sampling rate allows users to observe fast-changing waveforms and, on the other hand, long memory depth aims for continuously
changing waveforms. The MSO-2000 series is equipped with waveform search and segmented memory functions to expand the flexible
applications of 10M long memory. The segmented memory can be divided the maximum into 29,000 sections for users to bypass any
unimportant waveforms so as to swiftly search all required waveforms. With the segmented memory function, more meaningful
waveforms can be saved and target waveforms can be displayed rapidly. Users, by using the waveform search function, can rapidly search
desired waveforms according to the required trigger conditions.

16-channel logic analyzer has a memory depth of 10Mpts per channel, which can retrieve
more and longer digital signals as well as clearly display digital signals to obtain sufficient
information for analysis. The minimum input swing of logic analyzer represents the
minimum operating voltage of 250 mV, which demonstrates that digital channels are
highly sensitive with respect to input. The standard bus trigger and decoding functions
include serial and parallel bus such as I2C, SPI, UART (RS232/422/485) and CAN/LIN bus
for automotive communications. The parallel bus function is only for digital channels. Bus CAN Bus Trigger and Decode
waveforms can be triggered and decoded in real time. The MSO-2000 series offers
complete analysis and debugging capabilities with the economical pricing.

In addition to a 16-channel logic analyzer, MSO-2000EA has a built-in dual channel 25MHz
arbitrary waveform generator with the modulation capability and also features 14 bits vertical
resolution; sample rate of 200MSa/s; 5 standard output waveforms (Sine, Square, Pulse,
Ramp, DC, Noise) and 7 user-defined waveforms (Sinc, Gaussian, Lorentz, Exponential Rise,
Exponential Fall, Haversine, Cardiac); AM/FM/FSK modulation and sweep function. The
user friendly interface is the ideal choice for applications such as circuit simulation and
education tests. Dual Channel Arbitrary Waveform Generator

A. 120,000wfm/s WAVEFORM UPDATE RATE AND VPO WAVEFORM DISPLAY TECHNOLOGY

The MSO-2000 series oscilloscope allows users to easily and displays signals with three dimensional waveforms constructed
completely observe inrush signals and rare transient waveforms by amplitude, time and signal strength to show each waveform
to increase waveform debugging efficiency by using features, point. 256 color gradients yield clear waveform changes.
including advanced VPO (Visual Persistence Oscilloscope) Comparing with the conventional digital storage oscilloscope,
signal processing technology, waveform update rate as high as the MSO-2000 series provides more natural and more genuine
120,000 wfm/s, and multi-layered afterglow display to enhance signal display effect which is very close to the original analog
waveform display efficiency. Oscilloscope with VPO technology signal.
B. DUAL DISPLAY SCREEN ZOOM-IN AND PLAY/PAUSE FUNCTIONS C. 1M FFT FREQUENCY DOMAIN DISPLAY FUNCTION

The MSO-2000 series provides the dual display screen zoom-in


The FFT function of the MSO-2000 Series provides the maximum
function to simultaneously display waveforms and major target
areas. Users can zoom in display area by adjusting time/div. Under 1M display for more precision frequency domain display. The
zoom-in mode, waveform can be played or paused so as to function supports four-window displays, including Rectangular,
automatically view all input waveforms on the moving zoom-in Hamming, Hanning, and Black-harris. Users select window display
screen. User can swiftly identify each desired event. Manual control for frequency domain analysis according to test requirements. The
play speed and direction can be adjusted according to users'
MSO-2000 series not only provides the FFT function but also
requirements. Press Pause to stop the play function. With
waveform search, all desired events from different stages can be FFTrms, vertical adjustment, and local zoom-in functions for users
rapidly identified and examined back and forth. The MSO-2000 to adjust waveforms of frequency domain by their requirements.
series is capable of swiftly searching signals and observing signals' Via rapid waveform update rate and waveform search functions,
details. 10M long memory depth provides the function of complete users can precisely observe the test results of frequency domain.
waveform retrieval and analysis.

D. 38 ITEMS OF AUTO MEASUREMENT SELECTION AND THE STATISTICS FUNCTION

The MSO-2000 series soundly provides 38 measurement items. provides 8 measurement selections. The statistics mode can also
Based upon the parameters such as voltage, current, time, frequency, be selected for users to analyze the mean value, the maximum,
and delay measurement, users can decide which measurement items the minimum, and standard deviation of the retrieved waveforms
to choose. On the single display screen, the MSO-2000E series to ensure signal's integrity and identify abnormal waveforms.

E. SUPPORT I C ,SPI ,UART,CAN, LIN BUS TRIGGER AND DECODING FUNCTION

Decode by Analog Channel Decode by digital Channel Display analog waveform converted from digital signal

The serial bus technology has been widely applied in the present channels, the analog waveform converted from digital channels
embedded application design. To rapidly and correctly trigger and can be observed so as to examine and analyze time-related analog
analyze serial bus data has posed a difficult challenge to engineers. and digital signals. The above-mentioned funciton can verify and
The MSO-2000 series provides parallel and serial bus analysis analyze the conversion between analog and digial signals. Currently,
function with 10M long memory depth. Users can select either many embedded designs are digital signals. The MSO series also
analog or digital channles to trigger, decode, and analyze frequently provides digital channels for parallel bus analysis and decoding.
used I C, SPI and UART serial bus and CAN/LIN bus, which is The above standard serial and parallel bus functions are the best
often used by automotive communications. While using digital test platform for school courses and embedded circuit designs.
F. WAVEFORM SEARCH FUNCTION G. DIGITAL FILTER FUNCTION

Unfiltered Waveform with Filtered Waveform,


Noise Interference Noise Removed
Users can rapidly search desired waveforms according to the trigger
condition. After activating the search function, hollow inverted
Engineers are often troubled by noise interference while measuring
triangles will show the location met the trigger condition. The upper
left hand corner Overall will show the total number of waveforms signals in the electric circuit tests. The MSO-2000 series features
met the trigger condition. Users can set waveform search by the the digital filter function which can be set to high pass or low pass
trigger condition such as Edge, pulse width, Runt, Rise/Fall, and Bus. digital filter. Digital filter allows users to independently set filter
When the trigger condition is met, hollow inverted triangles will frequency for each channel. The tracking on function rapidly sets
appear. Users can save all marks to compare with the next input
same filter frequency for all channels.
signal. The front panel of the MSO-2000 series controls waveform
zoom-out and play/pause function to swiftly identify each desired
event. The function allows users to conveniently complete waveform
search and save marks for rapid comparison and analysis.

H. DATA LOG FUNCTION I. SEGMENTED MEMORY FUNCTION

Users Can Also Select Analyze Segments to Conveniently Obtain


The Analysis Results.
Users, via the data log function, can observe waveform changes
in long periods of time to ensure product reliability or measure To achieve the most ideal application for memory depth, the MSO-
2000 series has the built-in segmented memory function. The
sporadically appeared signals. The data log function, based on segmented memory function allows users to select the desired
the requirements, can set record time and interval. Record time important signals for observation. Hence, insignificant signals can
can be selected from 5 minutes to 100 hours, and record interval be neglected and serial bus decoding; pulse or inrush signals can
is 5 seconds, the minimum. Waveform type for record data and be identified when retrieving signals. The segmented memory
CSV file format for each channel can also be selected. Data can function of the MSO-2000 series allows users to select the number
of sections. The maximum sections can be selected are 29,000.
be stored in USB drive, the MSO-2000 series or the remote After activating the function, users can select and observe waveform
computer via LAN. for each segment by turning the Variable knob. The ultimate
application of memory depth, therefore, is completely realized.

J. MASK FUNCTION

The MSO-2000 series provides the Mask function, which allows 10 points to meet test requirements. Users can also refer to the
users to apply Auto Mask and user-defined Mask to determine examples from user manual to edit Mask by the PC to satisfy all
whether the quality of the product meets the regulation. Via user- test needs. By setting Save On, users can log and monitor signals,
defined mask, users can set up to 8 areas and each area is up to which violate test conditions.
PANEL INTRODUCTION

high Speed Ethernet


1 2

9
5
8

1. Hardcopy Key
10 7 6
2. Autoset, Run/Stop, Single &
Default Keys
3. Search and Zooming Controls
4. Trigger Controls
5. Math, Reference & Bus Keys
11 12 6. Probe Calibration Output
14 13
15 7. USB Host Port
8. Option Key
9. Menu Off Key
10. Logic Analyzer Probe Connector
11. USB Device Port
12. LAN Port
13. Go-NoGo Output
14. Calibration Output
15. Dual Channel Arbitrary Waveform
Generator ( MSO-2000EA only )

MSO-2000E Series S E L E C T I O N G U I DE
Model MSO-2204E MSO-2202E MSO-2104E MSO-2102E MSO-2074E MSO-2072E

Bandwidth 200MHz 200MHz 100MHz 100MHz 70MHz 70MHz

Channels 4 2 4 2 4 2

Record Length 10M / ch 10M / ch 10M / ch 10M / ch 10M / ch 10M / ch

Real-time Sampling Rate Max. 1 GSa/s Per channel 1 GSa/s Max. 1 GSa/s Per channel 1 GSa/s Max. 1 GSa/s Per channel 1 GSa/s

Built-in 16 Channel Logic Analyzer

M S O - 2 0 0 0 E A S e r i e s S E L E C T I O N G U I DE
Model MSO-2204EA MSO-2202EA MSO-2104EA MSO-2102EA MSO-2074EA MSO-2072EA

Bandwidth 200MHz 200MHz 100MHz 100MHz 70MHz 70MHz

Channels 4 2 4 2 4 2

Record Length 10M / ch 10M / ch 10M / ch 10M / ch 10M / ch 10M / ch

Real-time Sampling Rate Max. 1 GSa/s Per channel 1 GSa/s Max. 1 GSa/s Per channel 1 GSa/s Max. 1 GSa/s Per channel 1 GSa/s

Built-in 16 Channel Logic Analyzer and Dual Channel 25MHz Arbitrary Waveform Generator
SPECIFICATIONS
MSO-2072E(A) MSO-2074E(A) MSO-2102E(A) MSO-2104E(A) MSO-2202E(A) MSO-2204E(A)
VERTICAL Channels 2Ch+EXT 4Ch 2Ch+EXT 4Ch 2Ch+EXT 4Ch
SENSITIVITY
Bandwidth DC~70MHz(-3dB) DC~100MHz(-3dB) DC~200MHz(-3dB)
Rise Time 5ns 3.5ns 1.75ns
Bandwidth Limit 20MHz 20MHz 20M/100MHz
Vertical Resolution 8 bits : 1mV ~ 10V/div
Input Coupling AC, DC, GND
Input Impedance 1M// 16pF approx.
DC Gain Accuracy (3% when 2mV/div or greater is selected ; (5%) when 1mV/div is selected
Polarity Normal & Invert
Maximum Input Voltage 300Vrms , CAT I (300Vrms CAT II with GTP-070B-4/100B-4/200B-4, 10 : 1 probe)
Offset Position Range 1mV/div ~ 20mV/div : 0.5V ; 50mV/div ~ 200mV/div : 5V ; 500mV/div ~ 2V/div : 25V ; 5V/div~10V/div : 250V
Waveform Signal + , - , , , FFT , FFTrms , Uesr Defined Expression
Process FFT : 1Mpts ; FFT : Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS ; FFT Window Displays : Rectangular, Hamming ,
Hanning, Blackman-Harris
TRIGGER Source CH1 ,CH2, CH3, CH4, Line, EXT* ; *dual channel models only.
Trigger Mode Auto (Supports Roll Mode for 100 ms/div and slower), Normal, Single Sequence
Trigger Type Edge, Pulse Width(Glitch), Video, Pulse Runt, Rise & Fall(Slope), Alternate, Time out, Event-Delay(1~65,535 events),Time-Delay(Duration;4ns~10s), Bus
Trigger Holdoff Range 4ns ~ 10s
Coupling AC, DC, LF rej. , Hf rej. , Noise rej.
Sensitivity 1div
EXT TRIGGER Range 15V
Sensitivity DC ~ 100MHz Approx. 100mV; 100MHz ~ 200MHz Approx. 150mV
Input Impedance 1M3%, ~16pF
HORIZONTAL Time Base Range 1ns/div ~ 100s/div (1-2-5 increments); ROLL : 100ms/div ~ 100s/div
Pre-trigger 10 div maximum
Post-trigger 2,000,000 div maximum
Time Base Accuracy 50 ppm over any 1 ms time interval
Real Time Sample Rate Max. : 1GSa/s (4ch model); Per channel 1GSa/s (2ch model)
Record Length 10Mpts/CH
Acquisition Mode Normal, Average, Peak Detect, Single
Peak Detection 2ns (typical)
Average Selectable from 2 to 256
X-Y MODE X-Axis Input Channel 1 ; Channel 3* ( * : four channel models only )
Y-Axis Input Channel 2 ; Channel 4* ( * : four channel models only )
Phase Shift 3 at 100kHz
CURSORS AND Cursors Amplitude, Time, Gating Available; Unit : Seconds(S), Hz(1/S), Phase (Degrees), Ratio(%)
MEASUREMENT Automatic 38 sets : Pk-Pk, Max, Min, Amplitude, High, Low, Mean, Cycle Mean, RMS, Cycle RMS, Area, Cycle Area, ROVShoot, FOVShoot, RPREShoot,
Measurement FPREShoot, Frequency, Period, RiseTime, FallTime, +Width, -Width, Duty Cycle, +Pulses, -Pulses, +Edges, -Edges, %Flicker, Flicker Idx., FRR, FRF,
FFR, FFF, LRR, LRF, LFR, LFF, Phase Cursors measurement
Control Panel Function Cursors measurement
Auto Counter 6 digits, range from 2Hz minimum to the rated bandwidth
Autoset Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo Autoset
Save Setup 20set
Save Waveform 24set
DISPLAY SYSTEM TFT LCD Type 8" TFT LCD WVGA color display
Display Resolution 800 horizontal x 480 vertical pixels (WVGA)
Interpolation Sin(x)/x
Waveform Display Dots, Vectors, Variable persistence(16ms~10s), Infinite persistence
Waveform Update Rate 120,000 waveforms per second, maximum
Display mode YT ; XY
Display Graticule 8 x 10 divisions
INTERFACE USB Port USB 2.0 Full-speed host port x 1, USB High-speed 2.0 device port x 1
Ethernet Port (LAN) RJ-45 connector, 10/100Mbps with HP Auto-MDIX
Go/NoGo BNC 5V Max/10mA TTL open collector output
Kensington Style Lock Rear-panel security slot connects to standard Kensington-style lock
LOGIC Sample Rate Per Channel 1GSa/s
ANALYSER Bandwidth 200MHz
SPECIFICATIONS Record Length Per Channel 10M pts (max)
Input Channels 16 Digital (D15 - D0)
Trigger Type Edge, Pattern, Pulse Width, Serial bus (I2C, SPI, UART(RS232/422/485), CAN, LIN), Parallel Bus
Thresholds Quad D0~D3, D4~D7,D8~D11 ,D12~D15 Thresholds
Threshold Selections TTL, CMOS(5V,3.3V,2.5V), ECL, PECL,0V ,User Defined
User-defined Threshold Range 5V
Maximum Input Voltage 40 V
Minimum Voltage Swing 250 mV
Vertical Resolution 1 bit
AWG Channels 2
SPECIFICATIONS Sample Rate 200 Msa/s
(MSO-2000EA only) Vertical Resolution 14 bits
Max. Frequency 25 MHz
Standard Waveform Sine, Square, Pulse, Ramp, DC, Noise
Built-in ARB Waveform Sinc, Gaussian, Lorentz, Exponential Rise, Exponential Fall, Haversine, Cardiac
Output Range 20 mVpp to 5 Vpp, HighZ;10 mVpp to 2.5 Vpp, 50
Output Resolution 1mV
Output Accuracy 2% (1 kHz)
Offset Range 2.5 V, HighZ;1.25 V, 50
Offset Resolution 1mV
POWER SOURCE Line Voltage Range AC 100V ~ 240V, 48Hz ~ 63Hz, auto selection
MISCELLANEOUS Multi-Language Menu Available
On-Line Help Available
Time clock Time and date, provide the date/time for saved data
Operation Environment Temperature: 0C to 50C. Relative Humidity: 80%, 40C or below; 45%, 41C ~ 50C
DIMENSIONS & WEIGHT 384(W) X 208(H) X 127.3(D)mm, Approx. 2.8 kg
Note : Three-year warranty, excluding probes & LCD display panel. Specifications subject to change without notice. MSO2000GD1DH
ORDERING INFORMATION OPTIONAL ACCESSORIES
MSO-2204E(A) 200MHz, 4 + 16 Channel, Mixed-signal Oscilloscope GTL-16E 16-Channel Logic Analyzer Probe GCP-100 Current Probe, DC ~ 100K, 100A, Current Probe
MSO-2202E(A) 200MHz, 2 + 16 Channel, Mixed-signal Oscilloscope GRA-426 Rack Adapter Panel GCP-1030 Current Probe, DC ~ 100MHz, 30Arms, Current Probe
MSO-2104E(A) 100MHz, 4 + 16 Channel, Mixed-signal Oscilloscope GAK-003 50 Impedance Adapter GCP-206P Current Probe - Power Supply, 2 Channel Power Supply
MSO-2102E(A) 100MHz, 2 + 16 Channel, Mixed-signal Oscilloscope GSC-008 Soft Carrying Case for GCP-530/1030
MSO-2074E(A) 70MHz, 4 + 16 Channel, Mixed-signal Oscilloscope GTL-246 USB Cable, USB 2.0, A-B Type, 1200mm GCP-425P Current Probe - Power Supply, 4 Channel Power Supply
MSO-2072E(A) 70MHz, 2 + 16 Channel, Mixed-signal Oscilloscope GDB-03 Oscilloscope Education & Training Kit for GCP-530/1030
(A) have built-in a Dual Channel 25MHz Arbitrary Waveform Generator GTP-033AOscilloscope Probe, 35MHz 1:1 Passive Probe, GCP-530 Current Probe, DC ~ 50MHz, 30Arms, Current Probe
BNC(P/M) GDP-025 Differential Probe, 25M High Voltage Differntial Probe
ACCESSORIES GCP-005 Current Probe, 40Hz~1kHz, 5A, Current Probe GDP-050 Differential Probe, 50M High Voltage Differntial Probe
Quick start guide,User manual CD x 1,Power cord x 1, GTL-16E:16-Channel Logic Analyzer Probe GCP-020 Current Probe, 40Hz~40kHz, 240A, Current Probe GDP-100 Differential Probe, 100M High Voltage Differntial Probe
GTP-070B-4:70MHz(10:1/1:1)Switchable passive probe for MOS-2072E(A)/2074E(A)(one per channel)
GTP-100B-4:100MHz(10:1/1:1)Switchable passive probe for MOS-2102E(A)/2104E(A)(one per channel) FREE DOWNLOAD
GTP-200B-4:200MHz(10:1/1:1)Switchable passive probe for MOS-2202E(A)/2204E(A)(one per channel) PC Software OpenWave software Driver USB driver ; LabView driver

Simply Reliable
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com

You might also like