The document provides technical specifications for LIFECO preaction and deluge valves models LF-DV100A and LF-DV150A. The valves have external resetting functions and are used in fire protection systems. They have simple configurations, are durable, reliable, and UL and FM approved. The valves operate to allow water flow into sprinkler systems when activated by detection devices via electric, dry pilot, or wet pilot actuation trim options.

Uploaded by

Farhan Ahmed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
661 views3 pages

Deluge Valve

The document provides technical specifications for LIFECO preaction and deluge valves models LF-DV100A and LF-DV150A. The valves have external resetting functions and are used in fire protection systems. They have simple configurations, are durable, reliable, and UL and FM approved. The valves operate to allow water flow into sprinkler systems when activated by detection devices via electric, dry pilot, or wet pilot actuation trim options.

Uploaded by

Farhan Ahmed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

TECHNICAL DATA SHEET

for use by Architects & Engineers

Preaction & Deluge Valve


Model No: LF-DV100A & LF-DV150A

Deluge Valve Equipped with Trim:


When the deluge valve operates, it continually vents the diaphragm chamber to prevent
the deluge valve from the resetting condition. Deluge valve can only be reset after the
system is taken out of service and trim piping is depressurized and drained.

In Service Condition:
System pressure is supplied to the diaphragm chamber through the restricted priming line
equipped with y-strainer. System water supply pressure which trapped in the diaphragm
chamber holds the clapper on seat due to its area differential design.

In Activate Condition:
When the release system operates, pressure is released from the diaphragm chamber
with the speed that is faster than when it is supplied through the setting pipeline. Water
supply pressure forces the clapper off seat allowing water to flow through the outlet and
into the system and alarm devices.

Features Electric Actuation Trim:


Simple configuration for easy maintenance. To actuate the Preaction & deluge valve electrically, the solenoid valve is provided to
No False Alarm drain the water from the diaphragm chamber of the valve body. The pressure switch is
Outstanding Durability provided to activate an electric alarm, to shut down the desired equipment or to give
Anti-corrosive Trim alarm signal to the panel.
Reliable Operation
Field replaceable diaphragm and clapper seat Dry-Pilot/Wet-Pilot Actuation Trim:
UL LISTED Dry-pilot actuation trim provides for connection of a detection system consisting of
FM APPROVED dry-pilot line sprinkler (as a heat detectors) containing air under pressure. Wet-pilot
actuation trim also wet-pilot line sprinkler containing pressurized water. Due to release of
Description any one of the actuation devices, air pressure or water pressure of the pilot line is
LIFECO Preaction & Deluge Valve with external resetting function is a differential latch type depressurized.
valve which designed for fire protection system.
The pressure switch is provided to activate an electric alarm, to shut down the desired
The external resetting feature of the LF-DV valve provides easy resetting of a pre-action equipment or to give alarm signal to the panel.
system without opening the valve cover for manual repositioning of the clapper and latch
mechanism. Technical & Environmental Specification
Model LF-DV100A & LF-DV150A
Actuation of electric system automatically releases the LF-DV valve by allowing water to Maximum working pressure 175 psi (12 bar)
Flange connection ANSI B16.1 FF Class 150
flow into the sprinkler piping system and to be discharged from any sprinklers that is
Hydrostatic test pressure 25 bar (350psi)
open. Approximate net weight 4 (100A) 59kg (included trim)
6 (150A) 79kg (included trim)
Single Interlock Preaction System:
Materials
Single Interlock Preaction System is generally used to protect area where there is a danger
of water damage that might result from malfunction of automatic sprinkler or piping. Body/Cover/Clapper Gray cast iron
Seat ring Bronze
Typically, such areas include computer rooms, storage areas for valuable artifacts,
Diaphragm EPDM
libraries and archives. Clapper seat VITON

Single Interlock Preaction System is also effectively used to protect properties where the Part List
pre-alarm might activate (fire) prior to sprinkler discharge that condition may allow time
1 Body/Cover Cast iron
for fire extinguishment by alternate suppression. 2 OS&Y valve
3 Air control valve
When operation of the electrical detection device, heat sensitive detector and smoke 4 Pressure switch
detector, electrical manual control station signals the valve releasing panel to operate the 5 Water supply valve
solenoid valve. In turns, the operated solenoid valve opens to release water from the 6 Solenoid valve
diaphragm chamber faster than when it replenished through the provided 3/8 restriction. 7 Drip check valve
8 PS test valve
9 PS signal control valve
10 Manual valve

HEADQUARTERS Unit 8, Calibre Industrial Park, Laches Close, Four Ashes, Wolverhampton, WV10 7DZ, United Kingdom T +44 1902 798 706 F +44 1902 798 679 E [email protected] lifeco-uk.com
LTDS-10001 Rev. 00 Page 1
TECHNICAL DATA SHEET
for use by Architects & Engineers

Preaction & Deluge Valve


Model No: LF-DV100A & LF-DV150A

Dry Pilot Actuation Trim

Wet Pilot Actuation Trim

HEADQUARTERS Unit 8, Calibre Industrial Park, Laches Close, Four Ashes, Wolverhampton, WV10 7DZ, United Kingdom T +44 1902 798 706 F +44 1902 798 679 E [email protected] lifeco-uk.com
LTDS-10001 Rev. 00 Page 2
TECHNICAL DATA SHEET
for use by Architects & Engineers

Preaction & Deluge Valve


Model No: LF-DV100A & LF-DV150A

Electric Actuation Trim

HEADQUARTERS Unit 8, Calibre Industrial Park, Laches Close, Four Ashes, Wolverhampton, WV10 7DZ, United Kingdom T +44 1902 798 706 F +44 1902 798 679 E [email protected] lifeco-uk.com
LTDS-10001 Rev. 00 Page 3