100% found this document useful (1 vote)
335 views2 pages

HMD Kojak Selinge

Kojak Selinge Syringe is safe because it cannot be reused. Once the plunger is pushed towards the end, it automatically breaks on being pulled again. Please make sure the plunger is not pushed accidentally, before use.

Uploaded by

HMD Healthcare
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
335 views2 pages

HMD Kojak Selinge

Kojak Selinge Syringe is safe because it cannot be reused. Once the plunger is pushed towards the end, it automatically breaks on being pulled again. Please make sure the plunger is not pushed accidentally, before use.

Uploaded by

HMD Healthcare
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Dont push

the plunger!
Kojak Selinge Syringe is safe because it
cannot be reused. Once the plunger is
pushed towards the end, it automatically
breaks on being pulled again. Please
make sure the plunger is not pushed
accidentally, before use.

Re-use of Syringes
infect 22* million people
with AIDS/Hepatitis B
and other diseases
every year.

Plunger will
automatically break
when retracted from
this point

Hindustan Syringes & Medical Devices Limited


Business Office & Works: 174, Sector-25, Ballabgarh,
Faridabad (Haryana) - 121 004 (India)
Ph: +91-129-4289000 Fax: +91-129-4061164
E-mail: [email protected] *Facts & Figures from WHO Website
Frightening as these figures
sound, its true Reuse of Syringes
are responsible for much more
damage across India and
Developing World, than you ever
thought possible. And the only
way to be absolutely sure that the
syringe you buy has never been
used before i.e. it is reuse-proof; Step 1: Step 5:
that means it is automatically and Open the pack and take out syringe. Dispose off the syringe in a sharps
container.
involuntarily disabled after one
time use - Auto Disable Syringe.

Step 2:
Insert the needle into the vial and withdraw
fluid/medicament.
Step 6:
In case of reconstitution after step 3 pull the
piston backward to (extreme) keeping the
needle downward (to suck air).

Step 3:
Push the plunger for desired
dosage and expel air bubble.

Step 7:
Release Total Fluid in Injection vial keeping the Vial
downward. Then proceed with normal injection
procedure by withdrawing the medicament as in
step 2 followed by step no. 3, 4 & 5
*Caution: Piston must not cross the ring otherwise
A.D. Mechanism will get activated.

Kojak Auto Disable Syringe.


Step 4:
Compliant to ISO 7886-3 and Then proceed with normal injection procedure, including
7886-4 Type I. aspiration for enabling vein location and after giving the
injection, if the plunger is pulled back, it breaks.
The Auto Disable Syringe

You might also like