Cardio Serv
Cardio Serv
DEFIBRILLATOR/MONITOR
IN ANY SITUATION
With the defibrillators of the Just one gesture is all it takes to start
CardioServ family youre in control of the 3-step operating procedure quickly
all critical care situations. and easily. The clearly identifiable,
This generation of CardioServ units colour-coded steps exclude virtually all
was developed in close consultation with operating error and win you precious
you and your colleagues to give you more time.
reliability and greater control in any In the Autosequence mode, normal
situation. adult energy levels (pre-configured) are
The monitor with its high-resolution selected automatically in succession
LCD display can be rotated by up to without any need to increase the energy
180, allowing you to keep an eye on level, leaving you free to concentrate
your patient wherever you are: on the entirely on the patient.
ward, in the operating theatre, intensive The units compact design and low
care or emergency admissions. weight (only 8 kg, including mains
All the important critical event data adaptor, battery and paddles) plus
are recorded automatically and archived optional SpO2 and/or external
in the memory for recall when required, pacemaker means you have all the
e.g. for a printout. essential equipment you need at hand
in the clinic and in pre-hospital use,
now and in the future.
ON ANY WARD
Best-selling reliability - pacemaker electrodes, plug-in paddles, adhesive defib pads, battery servicing unit,
case and practical accessory pouch.
RELIABLE SOLUTIONS IN EMERGENCIES
General
Dimensions 432mm (W) x 172mm (H) x 377mm (D)
Weight with batteries approx. 8kg
Power supply battery and mains
operates with 12V d.c
Ambient conditions for storage and transport
Temperature -20 to +60 C
Relative air humidity 10% to 95%
Monitor
Display LCD display, 2-channel backlit
Resolution 115mm x 86mm (320 x 240 pixels)
Format erase bar, at 25mm/sec
Monitor can be tilted by up to 180
Insertion Alphanumeric insertion of alarms, settings and texts
Memory
Archiving of 40 x 16 second ECGs triggered by defibrillation or alarm,
each with 4 second pre-history and complete data block
Archiving of the last 80 events with date and time
Defibrillator
External and internal defibrillation Synchronous and asynchronous
Form of shock Monophasic, attenuated sine half-wave
Energy levels 2, 5, 7, 10, 20, 30, 50, 100, 150, 200, 300, 360 Joule, Autosequence
Energy selection Rotating knob on unit
Typical charging time to 360J 8 seconds
Defibrillation Via paddles or combined defibrillation/pacemaker electrodes
ECG derivation Via 3-lead (I, II, III) and 5-lead (I, II, III, aVL, aVR, aVF, V) ECG cable or via combined
defibrillation/pacemaker electrodes
Analogue output One Volt
Printer 50 mm thermo-printer with 2 registration channels and 25mm/sec feed rate
External pacemaker
Operating modes Demand and fix
Pulse frequency 30 to 180P/min
Pulsed current 0 to 200 mA
Pulse width 40 ms; 20 ms from 150 P/min
Pulse form Monophasic rectangular pulse
SpO2
Saturation display in 1% intervals from 0% to 100%
Format Plethysmogram (curve format)
Signal quality C-Lock ECG synchronization
CE-0366: CE marking indicating compliance with the Medical Device Directive 93/42/EEC, class IIb.
Specifications are subject to change without notice.
gemedicalsystems.com
European Headquarters World Headquarters Asia Pacific
Marquette Hellige GmbH GE Marquette Medical Systems, Inc. GE Medical Systems Hong Kong Ltd.
P.O. Box 60 02 65 8200 West Tower Avenue 11th Floor, The Lee Gardens, 33 Hysan Ave.
79032 Freiburg Germany Milwaukee, WI 53223 USA Causeway Bay Hong Kong
Tel. +49 761 45 43 - 0 Tel. +1 414 355 5000 Tel. +852 2100 6300
Fax +49 761 45 43 - 233 Fax +1 414 355 3790 Fax +852 2100 6292