Coupling Calculations and Ug-32 Unstayed Head Calculations
Coupling Calculations and Ug-32 Unstayed Head Calculations
For P-No.1 Group Nos. 1 and 2 materials the extreme fiber elongation
may be as great as 40% when The reduction by cold forming from the
as-rolled thickness is less than 10% at any location where the extreme
fiber elongation exceeds 5%.
UG-46(f)(2)
Required as per Code above for All vessels 18 in. (450 mm) to 36 in. (900 mm),inclusive,
I.D. shall have a manhole or at least two handholes or two plugged, threaded inspection
openings of not less than NPS 2 (DN 50).
UG-46(f)(3)
Required as per Code above for All vessels over 36 in. (900 mm) I.D. shall have a
manhole, except that those whose shape or use makes one impracticable shall have at
least two handholes 4 in. _ 6 in. (100 mm _ 150 mm) or two equal openings of equivalent
area
Pipe cap size =DN 750( 30 NPS) Sch STD = Seamless pipe shell
Seamless pipe shell and pipe cap are having the same dimensions,. So required thickness calculated above
as per Appendix-1, Para 1-1(a) is a minimum for pipe cap
T = (PD) / (2 SE-0.2P)
MAWP = S.E.t
(Ro 0.4 t)
MAWP = S.E.t
(Ro 0.4 t)
CA = Corrosion Allowance = 3 mm
MAWP = S.E.t
(Ro 0.4 t)
MAWP = S.E.t
(Ro 0.4 t)
CA = Corrosion Allowance = 1 mm
MAWP = S.E.t
(Ro 0.4 t)
CA = Corrosion Allowance = 1 mm
MAWP = S.E.t
(Ro 0.4 t)
As per Appendix 1 Para 1-2 (Addenda 2009) for Cylindrical Shells the following
Formula is used to calculate the thickness.
P
t = R 01 exp
SE
1.52
= 136.551 exp = 136.551 0.9872
118 x1
= 136.55 (0.01279)
USED IN U2 STAMP
REFERENCES
The following documents / drawings are part of Design Report for the vessel AD-
AR-004 against the User Design Specification UDS-AR-004 Rev 0
Sl. No. Description Document No. Rev.No No. of
Pages
1 Calculation Sheets FTV-AD-01 DCR 0 56
2 Vessel Skematic Sketch FTV AD#U2-04 0 1
3 General Assembly FTV-U2-AR-004 0 1
Drawing
4 General Notes & FTV-U2--TOL-AR- 0 1
Tolerances 004
5 Hub Nozzle Details FTV-U2-SRN-AR-004 0 1
6 Weld Map FTV-U2--WM-AR-004 0 1
7 Hemispherical Head FTV-U2--HD-AR-004 0 1
8 Hemispherical Template FTV-U2-TM-AR-004 0 1
UG-46 (f)(2)
All vessels 18 in. (450 mm) to 36 in. (900 mm),inclusive, I.D. shall
have a manhole or at least two handholes or two plugged, threaded
inspection openings of not less than NPS 2 (DN 50).