Pury P168tlmu A Bs 208 230v Productdatasheet
Pury P168tlmu A Bs 208 230v Productdatasheet
Job Name:
System Reference: Date:
UNIT OPTION
Standard Model.....................PURY-P168TLMU-A
Seacoast (BS) Model.................PURY-P168TLMU-A-BS
OUTDOOR VRF HEAT PUMP WITH ACCESSORIES
HEAT RECOVERY SYSTEM Joint Kit.............................for details see Pipe Accessories Submittal
BC Controller (required)..............for details see BC Controller Submittals
Low Ambient Kit .................for details see Low Ambient Kit Submittal
Snow/Hail Guards Kit......for details see Snow/Hail Guards Kit Submittal
Base Pan Heater Kit.............for details see Base Pan Heater Kit Submittal
NOTES:
*1. When applying product below -4 F, consult your design engineer for cold climate application best practices, including the use of a backup source for heating.
*2. For details on extended cooling operation range down to -10 F DB, see Low Ambient Kit Submittal.
Specifications are subject to change without notice. 2016 Mitsubishi Electric US, Inc.
<Accessories>
Connecting pipe
NOTES:
<Low pressure>
Elbow(ID28.58(1-1/8)OD28.58(1-1/8)) P120,P144,P168 1pc.
<High pressure>
=(5-15/16)4
(23-5/8)
600=1504
Pipe (ID25.4(1)ID19.05(3/4)) P120 1pc.
740(29-3/16)
150 (5-15/16)
Pipe (ID25.4(1)OD19.05(3/4)) P120 1pc.
70
(2-13/16)
for snow hood attachment) 49(1-15/16)
SEACOAST PROTECTION
19.5 831(32-3/4) 831(32-3/4) 19.5 Note1.Please refer to the engineering manual for information
<Snow hood attachment hole>
(13/16) (13/16) regarding necessary spacing around the unit and
1750(68-15/16)
foundation work. Outdoor unit must be mounted at least
Top view
Discharge air 12" off the ground or 12" above the highest average snow
depth, whichever is greater.
2.At brazing of pipes,wrap the refrigerant service valve
Control box
(11-15/16)
Connecting pipe specifications
1650(65)
panel
PURY-P120TLMU 19.05 Brazed 28.58 Brazed 25.4 28.58
5 (3/4) *1 (1-1/8) *1 (1) (1-1/8)
4
1347(53-1/16)
PURY-P144TLMU 22.2 Brazed 28.58 Brazed 25.4 28.58
8 (7/8) *1 (1-1/8) *1 (1) (1-1/8)
2 1 Fan box
77
A PURY-P168TLMU 22.2 Brazed 28.58 Brazed 25.4 28.58
(3-1/16)
(7/8) *1 (1-1/8) *1 (1) (1-1/8)
54(2-3/16)
*1 Use the included connecting pipe and connect to the refrigerant service
20 20 valve piping.
Standard: Salt Spray Test Method - no unusual rust development to 480 hours.
(13/16) (13/16) 526(20-3/4)
89
57 586(23-1/8) 57 75(3) 22-80(3-3/16)35(1-7/16) Oval hole NO. Usage Specifications
(5-3/4) 145
(8-9/16) 217
(2-1/4) (2-1/4) 541(21-5/16) 58(2-5/16) <Sling hole> 140 77 Knockout hole
(3-9/16)
Left side view 562(22-3/16) 140(5-9/16) 1 Front through hole
(5-9/16)(3-1/16)
Front view Front through hole
Refrigerant service valve Refrigerant service valve (Uses when twinning 45 Knockout hole
<High pressure> 2 For pipes
<Low pressure> kit (optional parts) (1-13/16)
is mounted.)
Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours.
150 94 Knockout hole
3 Bottom through hole
23-14(9/16)20(13/16) Oval hole (5-15/16) (3-3/4)
561(22-1/8) 150(5-15/16) 62.7 or 34.5 Knockout hole
4 Front through hole (1-3/8)
(2-1/2)
516(20-3/8)
327(12-7/8)
43.7 or 22.2 Knockout hole
(10-3/8)
84
29.5
262
(3-5/16)
(1-3/16)
Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.
65 Knockout hole
121 (4-13/16)
6 Bottom through hole
196 (7-3/4)
A (2-9/16)
Service valve 52 Knockout hole
7 Bottom through hole
94
(26-13/16)
80 795(31-5/16) 795(31-5/16) 80
(5-3/4) 146
(3-3/16) (Mounting pitch) (Mounting pitch) (3-3/16)
29.5
(1-3/16)
Service valve
( Bottom view ) Bottom view
Unit: mm (in.)
PURY-P168TLMU-A (-BS) DIMENSIONS