Calculation Sheet: Section Properties: Longitudinal Section A L1 X Y (MM) (MM) Grillage Member

The document contains calculation sheets for section properties of longitudinal sections A and B from a bridge superstructure assessment project. The sheets include: - Cross sectional area - Centroid X and Y coordinates - Second moments of area about the X and Y axes (Ixx and Iyy) For each longitudinal section, the coordinate points defining the cross section geometry are listed, followed by calculations of the section properties. In total, properties are summarized for 8 longitudinal sections (A L1-L3 and T1-T4, and B L1).

Uploaded by

Jennifer Hudson
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views

Calculation Sheet: Section Properties: Longitudinal Section A L1 X Y (MM) (MM) Grillage Member

The document contains calculation sheets for section properties of longitudinal sections A and B from a bridge superstructure assessment project. The sheets include: - Cross sectional area - Centroid X and Y coordinates - Second moments of area about the X and Y axes (Ixx and Iyy) For each longitudinal section, the coordinate points defining the cross section geometry are listed, followed by calculations of the section properties. In total, properties are summarized for 8 longitudinal sections (A L1-L3 and T1-T4, and B L1).

Uploaded by

Jennifer Hudson
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 30

CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section A L1

X Y
(mm) (mm)
3356 0 Grillage Member
4575 0
4385 381 2500
3377 381
1981 1559 2000
1981 1783
3661 1826 1500
3523 2102
1000
1753 2057
0 2057 500
0 1803
1219 1803 0
3356 0 0 500 100015002000250030003500400045005000

CROSS SECTIONAL AREA = 2176108.5 mm2


CENTROID X = 2445.00 mm
CENTROID Y = 1260.56 mm
SECOND MOMENT OF AREA Ixx = 1.1687E+12 mm4
SECOND MOMENT OF AREA Iyy = 2.6044E+12 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section A L2

X Y
(mm) (mm)
1051 0 Grillage Member
2270 0
2459 381 2500
2067 381
1915 533 2000
1915 1719
2067 1871 1500
3116 1902
1000
3358 2187
0 2102 500
137 1826
1254 1885 0
1406 1706 0 500 1000 1500 2000 2500 3000 3500 4000
1406 533
1254 381
860 381
1051 0

CROSS SECTIONAL AREA = 2206110 mm2


CENTROID X = 1664.57 mm
CENTROID Y = 1247.10 mm
SECOND MOMENT OF AREA Ixx = 1.2802E+12 mm4
SECOND MOMENT OF AREA Iyy = 8.4363E+11 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section A L3

X Y
(mm) (mm)
0 0 Grillage Member
1219 0
3349 1987 2500
4569 1987
4569 2241 2000
1114 2241
946 1902 1500
2588 1946
1000
2588 1693
1181 381 500
189 381
0 0 0
0 500 100015002000250030003500400045005000

CROSS SECTIONAL AREA = 2264179.5 mm2


CENTROID X = 2126.85 mm
CENTROID Y = 1378.71 mm
SECOND MOMENT OF AREA Ixx = 1.4286E+12 mm4
SECOND MOMENT OF AREA Iyy = 2.6184E+12 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section A T1

X Y
(mm) (mm)
0 0 Grillage Member
2667 0
2667 254 300
0 254
0 0 250

200

150

100

50

0
0 500 1000 1500 2000 2500 3000

CROSS SECTIONAL AREA = 677418 mm2


CENTROID X = 1333.50 mm
CENTROID Y = 127.00 mm
SECOND MOMENT OF AREA Ixx = 3.6420E+09 mm4
SECOND MOMENT OF AREA Iyy = 4.0153E+11 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section A T2

X Y
(mm) (mm)
0 0 Grillage Member
2667 0
2667 381 2500
0 381
0 0 2000
0 1854
2667 1854 1500
2667 2144
1000
0 2144
0 1854 500

0
0 500 1000 1500 2000 2500 3000

CROSS SECTIONAL AREA = 1016127 mm2


CENTROID X = 1333.50 mm
CENTROID Y = 190.50 mm
SECOND MOMENT OF AREA Ixx = 1.2292E+10 mm4
SECOND MOMENT OF AREA Iyy = 6.0230E+11 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section A T3

X Y
(mm) (mm)
0 0 Grillage Member
2667 0
2667 381 2500
0 381
0 0 2000
0 0
0 1930 1500
2667 1930
1000
2667 2210
0 2210 500
0 1930
0
0 500 1000 1500 2000 2500 3000

CROSS SECTIONAL AREA = 1016127 mm2


CENTROID X = 1333.50 mm
CENTROID Y = 190.50 mm
SECOND MOMENT OF AREA Ixx = 1.2292E+10 mm4
SECOND MOMENT OF AREA Iyy = 6.0230E+11 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section A T4

X Y
(mm) (mm)
0 0 Grillage Member
2667 0
2667 254 300
0 254
0 0 250

200

150

100

50

0
0 500 1000 1500 2000 2500 3000

CROSS SECTIONAL AREA = 677418 mm2


CENTROID X = 1333.50 mm
CENTROID Y = 127.00 mm
SECOND MOMENT OF AREA Ixx = 3.6420E+09 mm4
SECOND MOMENT OF AREA Iyy = 4.0153E+11 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section B L1

X Y
(mm) (mm)
3356 0 Grillage Member
4575 0
4384 381 2500
3849 381
2692 1357 2000
2692 1801
3662 1826 1500
3524 2102
1000
1752 2057
0 2057 500
0 1803
1219 1803 0
3356 0 0 500 100015002000250030003500400045005000

CROSS SECTIONAL AREA = 2921966 mm2


CENTROID X = 2529.88 mm
CENTROID Y = 1230.89 mm
SECOND MOMENT OF AREA Ixx = 1.3080E+12 mm4
SECOND MOMENT OF AREA Iyy = 2.8159E+12 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section B L2

X Y
(mm) (mm)
1051 0 Grillage Member
2270 0
2459 381 2500
2219 381
2067 533 2000
2067 1723
2219 1879 1500
3217 1904
1000
3358 2187
0 2102 500
138 1826
1104 1850 0
1254 1723 0 500 1000 1500 2000 2500 3000 3500 4000
1254 533
1102 381
860 381
1051 0

CROSS SECTIONAL AREA = 2687011.5 mm2


CENTROID X = 1666.90 mm
CENTROID Y = 1233.76 mm
SECOND MOMENT OF AREA Ixx = 1.3833E+12 mm4
SECOND MOMENT OF AREA Iyy = 9.4434E+11 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section B L3

X Y
(mm) (mm)
0 0 Grillage Member
1219 0
3349 1987 2500
4569 1987
4569 2241 2000
3197 2241
1087 2187 1500
946 1904
1000
1876 1928
1876 1446 500
733 381
189 381 0
0 0 0 500 100015002000250030003500400045005000

CROSS SECTIONAL AREA = 2999831.5 mm2


CENTROID X = 2046.59 mm
CENTROID Y = 1323.47 mm
SECOND MOMENT OF AREA Ixx = 1.5676E+12 mm4
SECOND MOMENT OF AREA Iyy = 2.8234E+12 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section B T1

X Y
(mm) (mm)
0 0 Grillage Member
2642 0
2642 254 300
0 254
0 0 250

200

150

100

50

0
0 500 1000 1500 2000 2500 3000

CROSS SECTIONAL AREA = 671068 mm2


CENTROID X = 1321.00 mm
CENTROID Y = 127.00 mm
SECOND MOMENT OF AREA Ixx = 3.6079E+09 mm4
SECOND MOMENT OF AREA Iyy = 3.9035E+11 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section B T2

X Y
(mm) (mm)
0 0 Grillage Member
2642 0
2642 381 2500
0 381
0 0 2000
0 1850
2642 1850 1500
2642 2144
1000
0 2144
0 1850 500

0
0 500 1000 1500 2000 2500 3000

CROSS SECTIONAL AREA = 1006602 mm2


CENTROID X = 1321.00 mm
CENTROID Y = 190.50 mm
SECOND MOMENT OF AREA Ixx = 1.2177E+10 mm4
SECOND MOMENT OF AREA Iyy = 5.8552E+11 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section B T3

X Y
(mm) (mm)
0 0 Grillage Member
2642 0
2642 381 2500
0 381
0 0 2000
0 0
0 1879 1500
2642 1879
1000
2642 2210
0 2210 500
0 1879
0
0 500 1000 1500 2000 2500 3000

CROSS SECTIONAL AREA = 1006602 mm2


CENTROID X = 1321.00 mm
CENTROID Y = 190.50 mm
SECOND MOMENT OF AREA Ixx = 1.2177E+10 mm4
SECOND MOMENT OF AREA Iyy = 5.8552E+11 mm4
CALCULATION SHEET No:

Project: Swalwell Interchange Superstructure Assessment By - RAC Date- 05/06

Subject: Section Properties Check Check


SECTION PROPERTIES : Longitudinal Section B T4

X Y
(mm) (mm)
0 0 Grillage Member
2642 0
2642 254 300
0 254
0 0 250

200

150

100

50

0
0 500 1000 1500 2000 2500 3000

CROSS SECTIONAL AREA = 671068 mm2


CENTROID X = 1321.00 mm
CENTROID Y = 127.00 mm
SECOND MOMENT OF AREA Ixx = 3.6079E+09 mm4
SECOND MOMENT OF AREA Iyy = 3.9035E+11 mm4