0% found this document useful (0 votes)
678 views

X7 Access Control System User Manual 20121115 PDF

The document provides instructions for installing and using an X7 access control system. It describes: 1) How to mount and install the device. 2) The system's functions including user authentication, door status monitoring, and alarms. 3) How to connect the device to locks, other devices, and power. 4) A recommended procedure for initial device setup and configuration. 5) Detailed steps for user management functions like adding, authenticating, and deleting users.

Uploaded by

Sudesh Chauhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
678 views

X7 Access Control System User Manual 20121115 PDF

The document provides instructions for installing and using an X7 access control system. It describes: 1) How to mount and install the device. 2) The system's functions including user authentication, door status monitoring, and alarms. 3) How to connect the device to locks, other devices, and power. 4) A recommended procedure for initial device setup and configuration. 5) Detailed steps for user management functions like adding, authenticating, and deleting users.

Uploaded by

Sudesh Chauhan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

X7 Access Control

System User Manual


1.Equipment Installation
Wall mount installation

(1)Remove the screw on the (2)Take away the back cover. (3)Fix the back cover on the
bottom of device. wall according to the
mounting paper.

(4)Fix the device to the back (5)Fix the screw.


cover.

2.Structure and Function


Access Control System Function:
(1)If a registered user verified, the device will
export the signal to unlock the door.
(2)Door sensor will detect the on-off state. If the
door is unexpected opened or improperly closed,
the alarm signal (digital value) will be triggered.
(3)If the device being illegally removed, the device
will export alarm signal.
(4)External exit button is supported; it is convenient
to open the door inside.
(5)External bell is supported.

1
3.Lock Connection

Warning: No operation when power on!


(1) The system supports NO LOCK and NC LOCK. For example the NO LOCK
(normally open at power on) is connected withNO terminal, and the NC LOCK is
connected with NC terminal.
(2) When the Electrical Lock is connected to the Access Control System, you need
to parallel one FR107 diode (equipped in the package) to prevent the
self-inductance EMF affect the system, do not reverse the polarities.
(I)Share power with the lock:

Device share power with the


lock:
ULOCK=12V,
I-ILOCK>1A 1
And the lock is near to the
device.

(II)Does not share power with the lock:

Device does not share power


with the lock:
A. ULOCK =12V I-ILOCK
1A;
B. ULOCK 12V;
C. The lock is far apart from the
device.

I: I: device output current, ULOCK: lock voltage, ILOCK: lock current.

2
4.Connected
4.Connected
4.Connected with
with
Other
with Other
Parts:
Other Parts:
Parts: 5.Connect
5.Connect
5.Connect with
with
Power:
with Power:
Power:

Input DC 12V, 500mA(50mA


standby)Positive is connected with
+12V, negative is connected
with GND (do not reverse the
polarities).

Voltage output DC 12V for Alarm

3
Instructions
Recommended Procedure:
Step 1: Install the device and power on.
Step 2: After the administrator password is authenticated and changed, register
users' fingerprints, cards, or passwords.
Step 3: Configure access control parameters, including modifying eight
passwords for opening the door and configuring the unlocking duration,
authentication mode, stealth mode, door status sensor mode, and alarm.
Functions of the Device
1.User Management
1.1 Administrator Operations
Authenticator the Administrator Password
Change Administrator Password
Open the Door by the Administrator Passwor
Administrator Password Be Forgotten
1.2 Add Users
Add Users
Register Cards in Batches
1.3 Authentication Users
1.4 Delete Users
Delete a User
Delete All Users
2.Access Control Management
2.1 Change Eight Passwords for Opening the Door
2.2 Configure Unlocking Duration
2.3 Configure Authentication Mode
2.4 Configure Concealed Mode
2.5 Configure Door Sensor Mode
2.6 Configure Alarm
Configure Alarm setting
Configure Error Operation-Triggered Alarm
Configure Tamper Alarm

4
Configure Alarm Delay for the Door Status Sensor

Operation Instructions
1.User Management
1.1 Administrator Operations
To ensure data security of the device, you can operate the device only after the
administrator password is authenticated.
Authenticator the Administrator Password

Note: The initial administrator password is 1234. You are advised to change the
initial password at the beginning.
Change Administrator Password

Note: Four-digit passwords are automatically verified. For passwords with less
than four digits, press # to enter the verification process.
Open the Door by Entering the Administrator Password

5
Note: This function can be used to open the door.
Administrator Password Be Forgotten
If the administrator password is forgotten, you can press the disassembly key
three times to reset the password to the initial administrator password 30 to 60
seconds after the device is disassembled from the wall or door. (There is a long
beep 30 seconds after the device is disassembled from the wall or door.)
1.2 Add Users
Register the fingerprint or card of a user or register cards in batches.
Add Users
3. Register fingerprints or
2. Press1.
1. The administrator cards. (Press fingers three
(The indicator turns green
password is authenticated. and makes a long beep.)
times to get a fingerprint or
swipe the card once.)
Failed.
(The indicator turns red YES
and makes three beeps.)
4. Adding Users is
5. Exit. successful.
(Press * to exit.) (The indicator turns green
and makes a long beep.)

Note:1. In the registration process, the user ID increases automatically. The


device automatically enters the process of registering the next user when a user is
successfully registered.

2. The registration process fails if the fingerprint is of poor quality or the


fingerprint or the card has been registered. After the device indicator turns green,
6
you can register the user again. Registered users must not be registered again.
Register Cards in Batches

Note: 1. In the process of entering the total number of cards, three-digit


numbers are automatically verified. For numbers with less than three digits, press
# to enter the verification process.Press * to reenter the total number of cards.

2. You must clear all the registered users before registering cards in batches. IDs
of to-be-registered cards must be consecutive numbers.

1.3 Authentication Users


Authentication Users' Fingerprints/Cards/Passwords

After the device is powered on, it enters the authentication state for users to
unlock the door.

2. Press fingerprints, swipe


1. The device is in the cards, or enter passwords. YES 3. The authentication is
authentication state. Press # after entering a successful.
password.

Failed.
(The indicator turns red
and makes three beeps.)

7
Note: Press # after entering a password for authentication. The door opens if
the entered password is identical with one of the eight passwords for opening the
door. The initial eight passwords for opening the door are 8888. For how to
change passwords for opening the door, see2.1 Change Eight Passwords for
Opening the Door.

1.4 Delete Users


Delete a user whose fingerprint or card is registered, or delete all users.

Delete a User

1. The administrator 2. Press2. 3. Enter a user ID, press the


password is authenticated. (The indicator turns green fingerprint, or swipe the
and makes a long beep.) card.
Failed.
(The indicator turns red
and makes three beeps.)
YES
6. Exit. 4. Determine whether the
(Press * or do not operate the 5. The user is deleted. user is authentic.
device within 20 seconds.)

Note: 1. In the process of entering user IDs, five-digit IDs are automatically
verified. For IDs with less than five digits, press # to enter the verification
process.

2. The device automatically enters the process of deleting the next user when a
user is deleted.

Delete All Users

8
Note: Press 9 for automatic confirmation. Other values are considered invalid.
If an invalid value is entered, the device indicator turns red, and the device makes
a long beep and exits the process.

2.Access Control Management


2.1 Change Eight Passwords for Opening the Door

Note: 1. If you set a password to an all-0 password after entering the password
ID, this password will be locked and you cannot use this password to open the
door.

2. If a password is successfully changed, enter the password ID of the

9
to-be-changed password to change the next password.

2.2 Configure Unlocking Duration

Note: Three-digit values are automatically verified. For values with less than
three digits, press # to enter the verification process. Values greater than 254 are
considered invalid.

2.3 Configure Authentication Mode

Note: 1. Details about the authentication mode are as follows:

Authentication type Description


Mode
Mode 1number1 PW Only password verification
Mode 2number2 RF Only RF Card verification
Mode 3number3 FP Only fingerprint verification

10
Mode 4number4 FP/PW/RF fingerprint or password or RF verification
Mode 5number5 RF&PW RF and password verification
Mode 6number6 FP&PW fingerprint and password verification

2.4 Configure Concealed Mode


If the Concealed mode is enabled, the indicator is off when the Concealed mode
is in the sleep mode.

Note: An indicator blinks to indicate the status of this function when users are
authenticating their cards or fingerprints.

2.5 Configure Door Sensor Mode


The door sensor switch includes three modes:

NONE: The door sensor switch is not used.


NO: The lock is open as long as the door is open.
NC: The lock is closed after the door is closed.

11
Note: The door sensor mode configured here is used as the basis for the door
sensor alarm.

2.6 Configure Alarm


Note: If an alarm is triggered, the buzzer of the device generates an alarm. 30
seconds later, the alarm is switched to an alert. The alarm can be terminated after
the user is authenticated.

Configure Alarm setting


The defaute should be on, when it is set to be close, then Error
Operation-Triggered Alarm, Tamper Alarm, the Alarm Delay for the Door Status
Sensor will be disabled.

Configure Error Operation-Triggered Alarm


If this function is enabled, alarms are generated if a user fails the authentication
upon three attempts. The administrator authentication is not allowed within 20
seconds after an alarm is generated.

12
Configure Tamper Alarm
If this function is enabled, alarms are generated upon device disassembly.

Configure whether to enable the disassembly alarm.

Configure Alarm Delay for the Door Status Sensor


DSen. Delay (Door Sensor Delay): indicates the delay in checking the door
sensor after the door is open. If door sensor state is inconsistent with the normal
state set by the door sensor switch, an alarm will be generated, and this period of
time is regarded as the door sensor delay.

13
Note: Three-digit values are automatically verified. For values with less than
three digits, press # to enter the verification process. Values greater than 254 are
considered invalid.

14