Manual Polarimeter
Manual Polarimeter
Instruction Manual
Introduction
Thank you for selecting the Bante Instruments WXG-4 manual polarimeter. This manual provides a step-by-step guide to help you operate the instrument,
please carefully read the following instructions before use.
The following list describes the standard accessories of the polarimeter. After the unpacking, please check all accessories are complete. If any are damaged
or missing, please contact nearest distributor.
Test tube 100 and 200 mm
Sealing rings
Prior to Use
Before plugging the plug into the power outlet, ensure that local mains power voltage matchs the polarimeter requirements.
1. Close the lid of polarimeter, press the power switch to ON position, the sodium lamp will gradually light up.
2. Wait for the light source to stabilize, rotate the focus knob until visual field became legible.
Focus knob
3. Rotate the vernier knob makes the vernier scale aim at zero position.
WXG-4 Manual Polarimeter 2
Bubble Trap
Measurement
1. Open the lid of polarimeter, place the test tube into the sample chamber. Note, the bubble trap is upward.
WXG-4 Manual Polarimeter 3
2. Close the lid, clockwise or anticlockwise rotate vernier knob until the visual field appears uniform brightness. Record the measured value.
3. Repeat above measurements 2 times and calculate the average of measured values.
Calculation
If the measured values are positive angle (Dextrorotatory substance), minus the value of the reference point shall be the actual measured value of the
substance. If the measured values are negative angle (Levorotatory substance), minus the 180o shall be the actual value of the substance.
=[]LC
Specifications
Model WXG-4
Measuring Range -180 o ~180 o
Scale Value 1o
Vernier 0.05 o
Magnifier 3X
Light Source Sodium Lamp
Wavelength 589.44nm
Test Tube 50/100/200mm
Power Requirements 220V/50Hz
Dimensions 500(L) 135(W) 330(H)mm
Weight 5kg
Hazardous Substance Statement
Bante Instruments Limited is committed to the reduction and eventual elimination of all hazardous substances in both the manufacturing process and finished
products we supply. We have an active manufacturing and procurement program to minimize and eliminate the use of harmful heavy metals such as cadmium,
lead, mercury and the like. New technologies and design parameters are also promoting these efforts and we expect to have little or no such materials in our
product in the coming years. We welcome our customer suggestions on how to speed up these efforts.
Warranty
The warranty period for polarimeter is one year from the date of shipment. Above warranty does not cover sodium lamp. Out of warranty products will be
repaired on a charged basis. The warranty on your polarimeter shall not apply to defects resulting from:
Improper or inadequate maintenance by customer.
Unauthorized modification or misuse.
Operation outside of the environment specifications of the products.
For more information, please contact the nearest authorized distributor.
The information in this document is subject to change without notice. Copyright Bante Instruments Limited, 2013. All rights reserved.