0% found this document useful (0 votes)
1K views4 pages

List of STR'S and Specifications: A. Block Instrument

This document lists signaling items and their specifications used in Indian Railways. It includes the specification or drawing number, STR (Standard Technical Requirement) number, and item description for various types of block instruments, cables, color light signals, electro-mechanical items, fuses and terminals, power supply equipment, and relays. The list contains over 100 signaling components categorized into groups such as cable, signals, circuit controllers, transformers, and relays.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views4 pages

List of STR'S and Specifications: A. Block Instrument

This document lists signaling items and their specifications used in Indian Railways. It includes the specification or drawing number, STR (Standard Technical Requirement) number, and item description for various types of block instruments, cables, color light signals, electro-mechanical items, fuses and terminals, power supply equipment, and relays. The list contains over 100 signaling components categorized into groups such as cable, signals, circuit controllers, transformers, and relays.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 4

LIST OF STR’s AND SPECIFICATIONS

S. SIGNALLING ITEM SPEC./DRG.NO. STR No.


No.
A. BLOCK INSTRUMENT:
1. Axle Counter Based Drg No. S-32001 SIQ-0001
Ver.1
B. CABLE:
1. PVC Insulated Armoured, Unscreened IRS:S-63/2007 (with Amdt-1) SIQ-0701
Underground Power Cable & IS:1554 ( Part-1) Ver.1
2. PVC Insulated Railway Signalling IRS:S-76/89 (Amendment-2) SIQ-0701
Indoor Single Core Cable Ver.1
3. PVC Insulated Railway Signalling IRS:S-76/89 (Amendment-2) SIQ-0701
Indoor Multi Core Cable Ver.1
4. PVC Insulated Armoured, Aluminum IRS:S-35/93 SIQ-0701
Screened Underground Cable Ver.1
5. PVC Insulated Armoured, Unscreened, IRS:S-63/2007 (with Amdt-1) SIQ-0701
Underground Railway Signaling Cable Ver.1
C. COLOUR LIGHT SIGNALS & LED SIGNALS:
1. Multi Unit Type - Without Side Light IRS:S-26/64 Drg No SA 23001 SIQ-0202
Ver. 0
2. Shunt Signal- Position Light Type Drg No:. SA-23840 SIQ-0202
Ver. 0
3. Route Indicator - Direction Type, Multi IRS:S-66/84 Amdt.1 & Drg SIQ-0202
Lamp Unit Type, Stencil Type No.SA-23401-06, SA-23761,SA- Ver. 0
21281
4. Light Unit – Lamp Holder Unit , Drg.No. S-23030/M Drg No. SIQ-0201
CLS Lamp Holder Unit (for triple pole SA-24831 IRS:S:75/2006 (Rev. Ver. 0
lamp) 2)
5. LED Signal- Lighting Unit (110 Volt RDSO/SPN/153/2004 (Rev. SIQ-0204
AC & DC LED Signal) 3.0) Ver. 0
6. LED based Semaphore Signal Lamp RDSO/SPN/169/2001 SIQ-0204
Ver. 0
7. Signal Colour Light – Lenses IRS:S-7/92 (Amdt. No. 4) Drg SIQ-0201
(Polycarbonate) No. S-24845 Ver. 0
Clear, Red, Green.
D. ELECTRO-MECHANICAL ITEMS:
1. Circuit Controller (Modified Design) Drg No.SA20245, 4666,67, SIQ-0203
Lever and Arm, DW Lever Circuit 76,77,86,87 Drg.No. Ver. 0
Controller (Rotary Type) SA-22401, 420, 430 & 440
2. Electric Point & Lock Detector IRS:S-49/74 (Amdt. No. 1) SIQ-0203
Drg.No.SA-23331, 32,33 Ver. 0
3. Electric Key Transmitter IRS:S-21/01 & Drg. No. SA- SIQ-0203
22601 (ALT4) Ver. 0
4. Lever Lock & Circuit Controller 200 Drg No SA 22701 &SA- SIQ-0203
mm stroke & 21201/M Ver. 0
(D.W.) 40 mm stroke
5. Electric Point Machine (Rotary Locking IRS:S-24/2002 (Amdt.- 1) SIQ-0203
Type) Ver. 0
6. Motor For Electric Point Machine IRS:S-37/82 (Amdt. No. 3) with SIQ-0203
Drg No. S-10910 Ver. 0

1
7. Electric Signal Machine IRS:S-25/97 & Drg.No SA- SIQ-0203
23851 (Adv), Ver. 0
SA-23852 (Adv)
8. Motor for Electric Signal Machine IRS:S-39/82 (Amdt . 2) with SIQ-0203
Drg No.SA23906 (ADV) Alt-4 Ver. 0
9. Signal Reverser - Electric IRS:S- 19/2000 (Amdt.No.1) SIQ-0203
Ver. 0
10. S.M.'s Control Frame IRS:S-48/74 SIQ-0203
Ver. 0
E. FUSES, FUSE BLOCK & TERMINALS BLOCK:
1. ARA Terminal Block & Fuse Block – IRS: S-75/2006 (Amdt. 2) & SIQ-0201
Made of PBT Drg.SA-23741A, Ver. 0
SA23745,SA-23746,SA-23748,
SA-23756
2. Terminal Block (Isolating Type) 8/10 IRS:S-79/92 (Amdt. No.2) SIQ-0201
Way &DRG No. SA-24811& Ver. 0
SA-24812
3. Tag Block IRS:S-77/2006 (Rev.1) SIQ-0201
withDrg.NO.SA-24751,52,53 Ver. 0
4. Top & Bottom Rollers, Nylon-6 IRS: S-97/2000 & Drg. No. S- SIQ-0201
3331,32 Ver. 0
F. POWER SUPPLY EQUIPMENTS:
1. Battery Charger - Self Regulating IRS:S-86/2000(Amdt. No.4 ) SIQ-0110
Ver.2
2. Battery Charger - Track Feed IRS:S-89/93 (Amdt. No.2 ) SIQ-0110
Ver.2
3. Battery Charger - Dual Bank IRS:S-85/92 (Amdt. No.2) SIQ-0110
Ver.2
4. Battery Charger - MFVR Batteries IRS:S-93/96(B) Amdt. 1 SIQ-0110
Ver.2
5. Converter - DC-DC IRS:S –96/2000 SIQ-0110
Ver.2
6. Inverter - Sine Wave IRS:S-82/92 (Amdt. No.2) SIQ-0110
Ver.2
7. Primary Cell - SITEL IRS:S-95/96 (Amdt. No.1) SIQ-0111
Ver. 0
8. Secondary Cell - Low Maintenance IRS:S-88/2004 SIQ-0113
Ver. 0
9. Solar Photo Voltaic Module IRS:S-84/92 (Amdt.2) SIQ-0112
Ver. 0
10. Transformer - CLS,110/12 V IRS:S-59/77 (Amdt.1) SIQ-0110
Ver.2
11. Transformer - 230/110 V IRS:S-72/88 (Amdt.2) SIQ-0110
Ver.2
12. Transformer-Indication H, I & L Type IRS:S-62/92 SIQ-0110
Ver.2
13. Transformer-Indication Supply IRS:S-83/92 SIQ-0110
Ver.2
14. Transformer-Rectifier Set IRS:S-91/93 (Amdt.1) SIQ-0110
Ver.2
15. Voltage Regulator-Ferro Resonant IRS:S-74/89 (Amdt.6) SIQ-0110
Ver.2
2
16. SMPS Based IPS RDSO/SPN/165/2004 (Amdt.5) SIQ-0110
Ver.2
G. RELAYS & COMPONENTS:
1. RELAYS -- Universal Plug-in type DC/ BRS:940,941A SIQ-0420
AC Lamp Proving Relay (Metal-to- Ver. 0
Carbon Contact) for
LED Signal Lamp
(ECRs for all aspects of AC & DC LED
Signals)
2. Relays -- Plug-In Type Tractive BRS:940,941A & 942 SIQ-0420
Armature, AC Lamp Proving Relay Ver. 0
(Metal-To-Carbon Contact) Signal
Lamp (ON, OFF, ROUTE, SHUNT
ECR)
3. Relays - ECRs (Metal-To-Metal IRS:S-46 & Firm’s Specn. SIQ-0420
Contact) Ver. 0
(ON, OFF, ROUTE & SHUNT aspect)
4. Relays - 'Q' Series Neutral Line (ACI & BRS:930 & BRS:931A SIQ-0420
NON-ACI) Ver. 0
5. Relays - Neutral Line (Metal-to-Metal IRS:S-46 & firm’s specn. SIQ-0420
Contact) , (ACI & Non-ACI) Ver. 0
6. Relays – Plug in Type, Track Relay 9 & BRS: 938A, 939A, 966 & SIQ-0420
4 Ohm Appendix F2 Ver. 0
(ACI & Non-ACI)
7. Relays – 3-Position DC Polarized IRS:S-31/80 (Amdt. No.1) SIQ-0420
Ver. 0
8. Relays – Special Type BRS: 930,932A, 933A, 935A, SIQ-0420
937A, 943, 960 & Ver. 0
RDSO/SPN-84/88 and Firm’s
Spec.
9. Relays – Special Type (M to M) IRS:S-46 & Firm’s Spec SIQ-0420
Ver. 0
10. Relay Contacts – SIG IRS:S-67/85 (Amd.2) SIQ-0421
Ver. 0
11. Relays – Neutral Line, Track (Shelf BS : 1659/50 upto amendment SIQ-0420
Type) no. 3 Ver. 0
H. TRACK CIRCUIT EQUIPMENT:
1. Audio Frequency Track Circuit RDSO/SPN/146/2001 SIQ-0001
Ver.1
2. Axle Counter - Universal Type IRS:S-42/85 & SIQ-0001
Drg No. S-15602-04 Ver.1
3. Single Section Digital Axle Counter RDSO/SPN/177/2005 Ver.-2 SIQ-0001
With Amnd-1 Ver.1
4. Multi Section Digital Axle Counter RDSO/SPN/176/2005 SIQ-0001
Ver.-2 Ver.1
5. Block Proving by Axle Counter DRG. No. S-32001 or latest SIQ-0001
(Universal) Ver.1

6. Block Proving by Axle Counter RDSO/S-32012 for Double SIQ-0001


(Digital) Line or latest Ver.1
RDSO/S-32016 for Single Line
or latest
3
7. Block Panel with UFSBI / MUX And RDSO/SPN/188/2004 or latest SIQ-0001
Digital Axle Counter Ver.1

8. Solid State Block Proving by Axle RDSO/SPN/175/2005 or latest SIQ-0001


Counter (Digital) Ver.1

9. Nylon Insulated Rail Joint IRS:S-40/84 Amdt. 1 Drg:Nos. SIQ-0201


SA-22101 (Alt.6) 52Kg; Ver. 0
SA-22171 (Alt.2) 60Kg;
SA-22181 (Alt.2) 60Kg(UIC)
SA-22191 (Alt.2) 90R
10. Thermoplastic Poly Urethane Rail RDSO/SPN-168/2005 SIQ-0201
Insulated Joint Ver. 0
I. ELECTRONIC SIGNALLING EQUIPMENT:
1. Data logger system IRS:S-99/2006 SIQ-0001
Ver.1
2. Universal Fail safe Block Interface RDSO/SPN/147/2005 SIQ-0001
Ver.1
3. Electronic Interlocking RDSO/SPN/192/2005 SIQ-0001
Ver.1
4. Train Actuated Warning Device RDSO/SPN/179/2003 Ver 1 or SIQ-0001
(TAWD) latest Ver.1
J. MISCELLANEOUS SIGNALLING ITEMS:
1. Electric Lifting Barrier IRS:S-41/70 (Amdt. No.2) SIQ-0114
Ver. 0
2. Electric Lifting Barrier with Hand RDSO/SPN/180/2005 (Amdt-1) SIQ-0114
Generator backup. Ver. 0