How To Resolve RTWP Problem
How To Resolve RTWP Problem
We've often found TMA's are a issue for RTWP. They will sweep and PIM test fine
but still cause RTWP.
nastotech
02-22-2017, 01:30 PM
Great tips.
Looks like most of RTWP problems are result of the jumper connections.
i have resolved the value just now, thanks to all
please use cabx command
================================================== =============================
===================== ================
Cell RX1(dBm) RX2(dBm) Delta TrDevices
================================================== =============================
===================== ================
S1C1 -85.5 -85.1 0.4 *1-1/RRUW-1/1 *1-1/RRUW-1/2
S1C2 -83.1 -83.4 0.3 *1-1/RRUW-1/3 *1-1/RRUW-1/4
--------------------------------------------------------------------------------
------------------------------------
see rssi value is -85 and -83.4
now increase this value (RX1 and RX2) to -108 if there is no combiner or TMA in
my case i have combiner so i increase the value by losing jumper connections at
RRU12 end and make VSWR high it automatically increase the RSSI Value
Now i Have
Cell RX1(dBm) RX2(dBm) Delta TrDevices
================================================== =============================
===================== ================
S1C1 -102.2 -101.8 0.4 *1-1/RRUW-1/1 *1-1/RRUW-1/2
S1C2 -100.1 -100.2 0.1 *1-1/RRUW-1/3 *1-1/RRUW-1/4
hope it will help