Pump Selection Condensate Pump: Deaerator Pressure With 10% Allowance Assuming Piping Pressure Drop

The document discusses the selection of condensate and boiler feed pumps for a 180MW steam power plant. The condensate pump capacity is calculated as 922,840 lb per hr or 1846 GPM, with a developed head of 146.4 ft. A Torishima CPCN model end-suction volute pump is selected. The boiler feed pump capacity is calculated as 1,215,900 lb per hr or 2432 GPM, with a developed head of 4520.6 ft. A pump will also be selected from the Torishima catalog.

Uploaded by

Jom Bonhayag
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
137 views3 pages

Pump Selection Condensate Pump: Deaerator Pressure With 10% Allowance Assuming Piping Pressure Drop

The document discusses the selection of condensate and boiler feed pumps for a 180MW steam power plant. The condensate pump capacity is calculated as 922,840 lb per hr or 1846 GPM, with a developed head of 146.4 ft. A Torishima CPCN model end-suction volute pump is selected. The boiler feed pump capacity is calculated as 1,215,900 lb per hr or 2432 GPM, with a developed head of 4520.6 ft. A pump will also be selected from the Torishima catalog.

Uploaded by

Jom Bonhayag
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Design of 180MW Steam Power Plant

PUMP SELECTION

Condensate Pump

The flow rate of the condensate from the condenser will be increased by 5%
as an allowance. The capacity of the condensate pump will be

Ccp = 878,895 x 1.05

Ccp = 922,840 lb per hr

Ccp = 1846 GPM

For the developed head,

Deaerator Pressure with 10% = 54.12


allowance =49.2X1.10 psia
Assuming Piping Pressure Drop =10 psi

=64.12
Total psia

=0.7382
Less Condenser Pressure psia
=63.4
Total psia

=146.4
Converting into Head (ft of water) ft.

From TORISHIMA PUMPMFG. CO., LTD pump catalog the following pump has
been chosen;

Brand: Torishima Pumps

Model: CPCN (End- Suction Volute Pump)

Pump Selection 24
Design of 180MW Steam Power Plant

Boiler Feed Pump

The flow
rate of the

water from the


deaerator will be increased by 5% as an allowance. The capacity of the boiler
feed pump will be

Cbfp = 107,140 x 1.05

Cbfp = 1,215,900 lb per hr

Cbfp = 2432 GPM

For the developed head,

= 1996.17
Boiler Pressure with 10% allowance =1814.7X1.10 psia
Assuming Piping Pressure Drop =10 psi

=2006.17
Total psia

Less Deaerator Pressure =49.2 psia


=1956.97
Total psia

=4520.6
Converting into Head (ft of water) ft.

From TORISHIMA PUMPMFG. CO., LTD pump catalog the following pump has
been chosen;

Pump Selection 25
Design of 180MW Steam Power Plant

Pump Selection 26