Design of 180MW Steam Power Plant
PUMP SELECTION
Condensate Pump
The flow rate of the condensate from the condenser will be increased by 5%
as an allowance. The capacity of the condensate pump will be
Ccp = 878,895 x 1.05
Ccp = 922,840 lb per hr
Ccp = 1846 GPM
For the developed head,
Deaerator Pressure with 10% = 54.12
allowance =49.2X1.10 psia
Assuming Piping Pressure Drop =10 psi
=64.12
Total psia
=0.7382
Less Condenser Pressure psia
=63.4
Total psia
=146.4
Converting into Head (ft of water) ft.
From TORISHIMA PUMPMFG. CO., LTD pump catalog the following pump has
been chosen;
Brand: Torishima Pumps
Model: CPCN (End- Suction Volute Pump)
Pump Selection 24
Design of 180MW Steam Power Plant
Boiler Feed Pump
The flow
rate of the
water from the
deaerator will be increased by 5% as an allowance. The capacity of the boiler
feed pump will be
Cbfp = 107,140 x 1.05
Cbfp = 1,215,900 lb per hr
Cbfp = 2432 GPM
For the developed head,
= 1996.17
Boiler Pressure with 10% allowance =1814.7X1.10 psia
Assuming Piping Pressure Drop =10 psi
=2006.17
Total psia
Less Deaerator Pressure =49.2 psia
=1956.97
Total psia
=4520.6
Converting into Head (ft of water) ft.
From TORISHIMA PUMPMFG. CO., LTD pump catalog the following pump has
been chosen;
Pump Selection 25
Design of 180MW Steam Power Plant
Pump Selection 26