Input Data: 2.1 Strength of An Anchor

This document calculates the strength of an anchor bolt in tension. It provides details of the concrete, anchor, and plate used. It then calculates: 1) The tensile strength as 1259 kN, limited by the anchor's tensile capacity. 2) The concrete breakout strength as 1032 kN without a plate and 1107 kN with a plate. 3) The pullout strength as 1738 kN without a plate and 4219 kN with a plate. 4) The side-face blowout strength as 1708 kN without a plate and 2660 kN with a plate. The minimum strength is governed by the tensile strength of 1259 kN

Uploaded by

sinambeladavid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
138 views3 pages

Input Data: 2.1 Strength of An Anchor

This document calculates the strength of an anchor bolt in tension. It provides details of the concrete, anchor, and plate used. It then calculates: 1) The tensile strength as 1259 kN, limited by the anchor's tensile capacity. 2) The concrete breakout strength as 1032 kN without a plate and 1107 kN with a plate. 3) The pullout strength as 1738 kN without a plate and 4219 kN with a plate. 4) The side-face blowout strength as 1708 kN without a plate and 2660 kN with a plate. The minimum strength is governed by the tensile strength of 1259 kN

Uploaded by

sinambeladavid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

1.

Input Data
Compressive strength of concrete f'c = 28 Mpa
Ultimate strength of anchor futa = 400 Mpa
Yield strength of anchor fya = 248 Mpa
Anchor bolt diameter da = 76.2 mm
Nos of thread nt = 8 threads per inch
nt = 0.315 threads per millimeter
Depth of embedment hef = 1275 mm
Distance from edge ca1 = 385 mm
Width of anchor plate W= 150 mm
Thickness of anchor plate B= 12 mm
Width across flat for nut head F= 4.625 inch
117.475 mm
Note: (*) = ACI 318M-2014

2. Anchor Strength for Tension Load


2.1 Strength of an anchor
The nominal strength of an anchor in tension:
(17.4.1.2)*
,

0.9743
where, ,
4

futa = min(futa, 1.9fya, 860 Mpa)


futa = 400 Mpa
Ase,N = 4197.62 mm2
Nsa = 1679.05 kN
T = 0.75
TNsa = 1259 kN

2.2 Concrete breakout strength


The nominal concrete breakout strength in tension:

, , , (17.4.2.1a)*

where, 1.5 2 1.5 and 9

Anc = 8,787,938 mm2 (without plate)


Anc = 9,430,688 mm2 (with plate)
Anco = 14,630,625 mm2
kc = 10 (for cast in anchors)*
a = 1 (normal concrete)*
.
where, (17.4.2.2a)*

/
3.9 (17.4.2.2b)*

Nb = 2409.04 kN
ed,N = 0.76039
where, , 1.0 if ca,min > 1.5hef (17.4.2.5a)*

, if ca,min < 1.5hef (17.4.2.5b)*


, 0.7 0.3
1.5
c,N = 1.25 (for cast in anchors)*
cp,N = 1 (for cast in anchors)*
Ncb = 1375.36 kN (without plate)
1475.95 kN (with plate)
T = 0.75
Ncb = 1032 kN (without plate)
1107 kN (with plate)

2.3 Pullout strength


The nominal pullout strength in tension:
,
(17.4.3.1)*

c,P = 1.4 (uncracked concrete)*


0.866 0.25 (without plate)

0.25 (with plate)

Abrg = 7390.76 mm2 (without plate)


17939.63 mm2 (with plate)
Np = 1655.53 kN (without plate)
4018.48 kN (with plate)
Npn = 2317.74 kN (without plate)
5625.87 kN (with plate)
T = 0.75
Npn = 1738 kN (without plate)
4219 kN (with plate)

2.4 Side-face blowout strength


The nominal side-face blowout strength:
13 (17.4.4.1)*

Nsb = 2276.81 kN (without plate)


3547.23 kN (with plate)

T = 0.75
Nsb = 1708 kN (without plate)
2660 kN (with plate)

2.5 Summary for Anchor Strength due to Tension Load

Without
Plate With Plate
Tensile (TNsa) 1259 1259
Concrete Breakout (Ncb) 1032 1107
Pullout (Npn) 1738 4219
Side-face blowout (Nsb) 1708 2660
1259 1259