Chapter10 Measurement
Chapter10 Measurement
Previously
When a measurement of the geomagnetic field is taken at any given point and time, the
resulting value contains the superposition of fields having different origins and varying in
magnitude:
Electric currents in the near-Earth space (> 100 km altitude) that are driven by solar
activity external magnetic field.
Changes in the strength and direction of the electric currents cause changes in the
field on time scales of about a year and more (secular variations).
The coefficients of the IGRF model (for example) are based on magnetic measurements
made by satellites and at the surface.
Content
Magnetometers
Geomagnetic observatories
Automatic stations
Satellite observations
Material: http://www.iugg.org/IAGA/index.html
Magnetometers
Definitions
Absolute instrument means an instrument capable of giving the magnitude of the magnetic
field or its component in absolute physical base units (e.g., m, kg, s, A, or their derivatives
or angle compared to geographical direction or horizontal plane) or universal constants
(e.g., gyromagnetic ratio of proton or electron).
Relative instrument is an instrument which measures the deviation from an undetermined
field. To know the value of the undetermined field, it is necessary to make an absolute
measurement. In the case of a variometer this value is called a baseline.
Semi-absolute instrument means a relative instrument which by frequent enough
comparisons with absolute instruments gives acceptably high accuracy for the measurement
in question.
Absolute measurements are made using an absolute or semi-absolute instrument to achieve
the required absolute accuracy.
Sensitivity tells how many units at the output of an instrument correspond to one physical
unit (e.g., how many bits for one nT).
Resolution describes what are the smallest changes recordable. The resolution is limited by
the noise level.
Accuracy decribes the real absolute accuracy. Accuracy of 0.1 nT says that the difference
between the true value and the measured one is not more than 0.1 nT.
Mean square error ( m ) is calculated from the scatter of the measurements.
1 /2
n
2i
m=
,
n1
i =1
where i is the deviation from the mean and n is the number of measurements.
Systematic error of a series of measurements is the deviation of the mean value from the
true value.
Absolute accuracy is determined by sum of the mean square error and the systematic error.
Relative accuracy of a recorded event is the ratio between the accuracy of the recorded
event and its amplitude, normally given in percents (%).
Precision describes the scatter of values. Precision of 0.1 nT means that the values are
within 0.1 nT from their mean value, but it says nothing of the accuracy.
Variometer is a magnetometer which is used to record variations of the magnetic field.
Fluxgate magnetometer
Typically, a fluxgate magnetometer has a resolution of 0.1 nT (or even 0.01 nT) and a bandwidth from DC to 5 Hz.
In fluxgate magnetometers constructed for observatory use or for other continuous
monitoring of the magnetic field, there usually are three orthogonal sensors fixed to the
same frame for the recording of the three components of the magnetic field. The sensor
assembly is usually rather small and robust. Fluxgate magnetometers are becoming the
most popular instruments at modern digital observatories due to their robust construction
and reliable electronics.
The fluxgate magnetometer measures the component along a particular axis of the sensor,
so it needs to be oriented. It measures the magnetic field continuously, but drifts over time.
10
11
The relationship between the frequency of the induced current and the strength of the
magnetic field is called the proton gyromagnetic ratio
=2 f = B
B=2 f / = g f ,
where g=2 / =23.487 nT/Hz
The polarization of the liquid in the sensor bottle takes, depending on the field used,
usually 2 6 seconds.
The longer times are used for getting more protons oriented into the direction of the field,
which means a stronger and longer signal in the measurement, allowing higher sensitivity
(0.1 nT) to be used.
The proton precession magnetometer measures the strength of the field but not its direction,
so it does not need to be oriented. Each measurement takes a second or more.
12
Overhauser magnetometer
Uses the same fundamental effect as the proton precession magnetometer to take
measurements.
By adding free radicals to the measurement fluid, the nuclear Overhauser effect can be
exploited. Rather than aligning the protons using a solenoid, a low power radio frequency
field is used to align (polarize) the electron spin of the free radicals, which then couples to
the protons via the Overhauser effect.
This has two main advantages:
driving the radio frequency field takes a fraction of the energy of the solenoid
(allowing lighter-weight batteries for portable units)
faster sampling as the electron-proton coupling can happen even as measurements are
being taken.
13
DI-flux magnetometer
Used to measure the declination (D) and inclination (I) of a magnetic field vector.
14
Fluxgate magnetometer
mounted on a non-magnetic
theodolite telescope.
15
Magnetic west
D measurement:
True north
D
Magnetic north
Magnetic east
16
The direction of the true north can be obtained using satellite positioning (e.g., GPS):
The azimuth of the great circle connecting the receives can be calculated from the
coordinates of the receivers using spherical trigonometry.
17
I measurement:
Theodolite
telescope
Fluxgate
sensor
Magnetic field
vector H
I
Magnetic
field vector B
18
The last step to complete the absolute measurement is to measure the strength of the
magnetic field B at the same location where the declination D and inclination I were
determined using the DI-flux magnetometer.
This is done by replacing the theodolite with a proton magnetometer sensor, which then
gives B.
The vector components of the magnetic field are obtained as
X = B cos I cos D
Y =B cos I sin D
Z =B sin I
19
Geomagnetic observatories
20
The objective of geomagnetic observatories is to record continuously, and over the long
term, the time variations of the magnetic field vector and to maintain the accurate absolute
standard of the measurements.
The observations should cover the relevant periods: 1 s 100 000 y and more.
Currently, observatory records exist for the past ~150 years (some observations exist for the
past 400 years).
Satellite observations cannot yet replace the traditional ground-based observatories,
because the life-times of satellite missions are relatively short, at most ~10 years.
There are global, regional and local needs for geomagnetic observatories.
21
An important global task is to monitor the secular variation of the magnetic field all over the world.
Knowledge of the secular variation is essential in updating magnetic charts and theoretical modeling of the
geomagnetic dynamo theory responsible for the generation of the field.
Monitoring the secular variation is the most difficult task of the magnetic observatories because the annual changes
are small. In the majority of areas of the world the number of magnetic observatories is not adequate for sufficiently
accurate determination of the secular variation.
A sufficiently dense global network is also needed for the calibration and control of magnetic survey satellites used
in detailed surveys of the magnetic field.
A global network is essential in monitoring magnetic storms and other magnetic variations, because these
phenomena affect large areas of the Earth and have different effects in different areas.
A global network is needed for research of current systems in the ionosphere and magnetosphere and induced
currents in the crust and mantle. A more dense network than the present one is needed in the high-latitude areas due
to their special role in a number of studies connected with magnetospheric phenomena, and also in the equatorial
region, where the behavior of the equatorial electrojet needs detailed study. The variations of the magnetic field near
the equator are also important for studies of the ring current in the near-Earth space.
22
A global model of the Earth's magnetic field (e.g., IGRF) may differ by thousands of nT
from the locally measured field.
A typical regional need for a magnetic observatory is to serve as a base station for magnetic
surveys. The data from the observatory or preferably from several observatories in the
region are used in reducing the measured survey data to the desired epoch. The final
product of a survey is usually a regional magnetic chart, which is later updated at regular
intervals with the help of the secular variation recorded at the observatories, thus making a
new detailed magnetic survey unnecessary. In many cases this means large savings of
funds.
Another regional use is working as a base station in magnetotelluric soundings.
23
From a local point of view, a magnetic observatory monitors the local magnetic variations,
the knowledge of which is needed, for example, in connection with observed power failures
or difficulties in telecommunications.
An observatory provides facilities for calibration of magnetic instruments.
Very often the observatory is the only place to obtain information on local geomagnetic
declination and its change, and in the case of special phenomena like aurora, confirmation
of the natural character of the phenomenon may be obtained from the observatory.
Local anomalies originate in the crust and provide information about the properties of the
rock complexes. Thus, local geomagnetic measurements are an important part of
geophysical prospecting.
24
Geomagnetic observatory
Variation room
Absolute room
X (t ) , Y (t ) , Z (t)
t : typical cadence 1- 10 s
B (t 0 ) , I (t 0 ) , D (t 0 )
t 0 : typical cadence one week
Variometers
X ,Y , Z
D,I ,B
X ,Y , Z
X (t )= X (t 0 ) X (t )
Y (t )=Y (t 0) Y (t)
Z (t )=Z (t 0 ) Z (t)
X (t 0 ) , Y (t 0 ) , Z (t 0 )
D,I ,B
D,I ,B
INTERMAGNET
26
There are
large gaps
in the
network,
especially
over
oceans.
28
The geographic latitude and longitude and altitude of the observatory are:
60.50oN, 24.65oE
105 m.
29
30
Variation measurements
The sensors are directed in geographic north and east directions measuring the X, Y and Z
components. The sampling rate is 1 s.
The temperature in the variometer room is kept at 18oC.
Analog voltages from the FGE magnetometer are AD-converted in the variation room and the digital
data are transferred through optical wires to the computers in the main observatory building. The
digital data of the LEMI-025 and of the GSM-90 are transfered through wireless internet to the main
observatory building. Linux-based software stores the data in three files as one-second, ten-seconds
and one-minute averages. Timing is based on GPS time shared through the local network. The
standard one-minute values are averages over one minute periods starting and ending at a half minute
(e.g., 59:30 - 00:30, 00:30 - 01:30, 01:30 02:30). The given time is the starting minute at the center
of the period (00, 01, 02 etc.).
31
32
http://space.fmi.fi/image/realtime/UT/NUR/XYZlast24.html
Universal time
Standard time zones of the world. The number at the bottom of each timezone specifies the number
33
of hours to add to UT to convert it to the local time.
Absolute measurements
The strength of the magnetic field (B) is measured with a Polish PMP-7 proton precession
magnetometer.
The declination and inclination of the magnetic field are measured with a DI-fluxmagnetometer, which consists of a non-magnetic Zeiss-Jena theodolite (010B) and of a
flux-gate element mounted on its telescope.
The absolute measurements are made on average once a week.
As an example, the baseline values determined for the suspended FGE for the year 2013 are
shown in the figure:
34
2013
35
Has been operating continuously since 1914 (the only gap in the time series is between
16th September 1944 and 1st January 1947 due to the destruction of the observatory during
the war).
The geographic latitude and longitude and altitude of the observatory are:
67.37 N, 26.63 E
180 m.
36
37
38
http://www.sgo.fi/Data/RealTime/magnetogram.php
Automatic stations
39
The main difference between an observatory and an automatic station is that an observatory
is usually manned, which guarantees a better quality of data and uninterrupted time series.
IMAGE consists of 33 mostly automatic magnetometer stations maintained by 10 institutes
from Estonia, Finland, Germany, Norway, Poland, Russia and Sweden.
The prime objectives of IMAGE are to study auroral electrojets and moving twodimensional ionospheric current systems.
Together with other ground-based recordings (by radars, riometers, all-sky cameras) and
satellite observations, IMAGE is an essential part in the investigations of high-latitude
magnetospheric-ionospheric physics.
40
41
42
44
45
Satellite measurements
46
CHAMP
47
48
49
50
SWARM
51
Copyright ESA/ATG Medialab,
ESA/AOES Medialab
The Swarm mission is designed to measure the magnetic signals that stem from the Earths
core, mantle, crust, oceans, ionosphere and magnetosphere.
This is expected to lead to better understanding of the processes that drive the Earths dynamo,
which currently appears to be weakening.
The mission will offer a unique view inside the Earth to study:
In addition, Swarm data will be used to study the Suns influence on the Earth system by:
52