100% found this document useful (1 vote)
226 views76 pages

2x600 MW Electrostatic-Precipitator

The document discusses the components, operation, and specifications of an electrostatic precipitator (ESP) being installed at a new 2x600 MW coal-fired power plant in Mahan, India. The ESP contains 9 fields to remove dust from flue gases. It uses wire discharge electrodes and plate collecting electrodes arranged in layers, along with a rapping system to dislodge collected dust. The power supply controls voltage to just below the spark-over point to maximize efficiency. Over 12,000 collecting plates and 32,000 discharge wires will be used across the two ESP passes.

Uploaded by

trung2i
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
226 views76 pages

2x600 MW Electrostatic-Precipitator

The document discusses the components, operation, and specifications of an electrostatic precipitator (ESP) being installed at a new 2x600 MW coal-fired power plant in Mahan, India. The ESP contains 9 fields to remove dust from flue gases. It uses wire discharge electrodes and plate collecting electrodes arranged in layers, along with a rapping system to dislodge collected dust. The power supply controls voltage to just below the spark-over point to maximize efficiency. Over 12,000 collecting plates and 32,000 discharge wires will be used across the two ESP passes.

Uploaded by

trung2i
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 76

Wednesday, August 19, 2015

ELECTROSTATIC PRECIPITATOR
CONTENTS
INTRODUCTION
PRECIPITATOR COMPONENTS
ARRANGEMENTS
BASIC PRINCIPLE
TECHNICAL SPECIFICATION
ERECTION SEQUENCE

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
INTRODUCTION
We are Setting up 2x600 MW Coal Based Thermal Power Plant at Mahan Bandhaura Site.
Electrostatic Precipitator is playing a vital role in most of the industries, such as
1) Thermal Power Plant
2) Cement Plant
3) Chemicals industries
4) Steel Plant
5) Paper Industries & etc

An electrostatic precipitator is a large, industrial emission-control unit. It is designed to


trap and remove dust particles from the exhaust gas stream of an industrial process.
In large power plants may actually have multiple no. of fields for each unit. In our plant,
there are 9 no. of fields per unit.
Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
MAJOR COMPONENTS OF ESP:
1) Rectifier Transformer
2) Discharge Electrodes
3) Collecting Electrodes
4) Gas Distribution Systems
5) Rapping system
6) Hopper.
About Rectifier Transformer: The power supply system is designed to provide high voltage to the field to increase the
collection efficiency at the highest possible level
The power supply system has four basic components:
1) Step-up transformer
2) High-voltage rectifier
3) Sensing device
4) Automatic voltage control
Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
DESCRIPTION ABOUT THE POWER SUPPLY SYSTEM
The voltage must be controlled to avoid causing sustained arcing or sparking
between the electrodes and the collecting plates

Automatic voltage control varies the power to the transformer-rectifier in response


to signals received from sensors in the precipitator and the transformer-rectifier
itself.
AVR monitors protects the internal components from arc-over damages, and protects
the transformer-rectifier and other components in the primary circuit.
Automatic voltage control would produce the maximum collecting efficiency by
holding the operating voltage of the precipitator at a level just below the spark-over
voltage.

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Spark reaction
When the voltage applied to the field is too high, then spark over will occur.

A voltage controller will monitor the primary and secondary voltage and
current of the circuit, and detect a spark over condition.

Once detected, the power applied to the field will be immediately cut off or
reduced, which will stop the spark.

After a short amount of time the power will be ramped back up, and the process
will start over.

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Tripping
When a condition occurs that the voltage controller cannot control, often times
the voltage controller will trip.

A trip means the voltage controller (by way of the contactor) will shut off the
individual precipitator power circuit.
A short inside the electrostatic precipitator field caused by a fallen discharge
electrode (wire), or a shorted out Silicone Controlled Rectifier are examples of
conditions that a voltage controller cannot control.

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
About Discharge Electrodes: Discharge electrodes emit charging current and provide voltage that generates an
electrical field between the discharge electrodes and the collecting plates.
The particles then precipitate onto the collecting plates. Common types of discharge
electrodes include:
1) Straight round wires
5) Rigid frames
2) Rigid spiked pipes
6) Spiral wires
3) Twisted wire pairs
7) Barbed discharge wires
4) Rigid masts

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Rigid Electrode

Wednesday, August 19, 2015

Spiral Electrode

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
About Collecting Electrodes: Collecting plates are designed to receive and retain the precipitated particles until they
are intentionally removed into the hopper. Collecting plates are also part of the electrical
power circuit of the precipitator.

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
About Gas distribution system:
Gas velocity distribution can be most effectively influenced by the use of gas distribution
devices. Ideally, uniformity is desired in:
1. Gas velocity
2. Gas temperature
3. Dust loading
Gas distribution devices consist of turning vanes in the inlet ductwork and perforated gas
distribution plates and in the outlet fields of the precipitator, flat distribution plate is
used.

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
INLET GD SCREEN

Wednesday, August 19, 2015

OUTLET GD SCREEN

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Rapping System:
To improve collection efficiency and ensure proper functional use of the precipitator,
a rapping system is applied to the collection and emitting electrodes to dislodge the
collected dust layer.

1) Collecting Rapping System:


Collecting plate rapping must remove the bulk of the precipitated dust. The collecting
plates are supported directly with hooks from the precipitator casing.
The impact of the rapping system is directed into the Shock bar located at the leading
and/or trailing edge of the collecting plates.
The first electrical field generally collects about 60-80% of the inlet dust load. So the
first field plates should be rapped often for the every cycle.

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Collecting Rapping System
COLLECTING FRAME

COLLECTING PLATE

SHOCK BAR

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Rapping cycle for the each field as follows:Field No.

Stage Efficiency %

Rapping frequency,
Raps/hr

80%

6/Hr

15%

4/Hr

3%

2/Hr

1.2%

1/Hr

0.55%

1/2Hr

0.11%

1/4Hr

0.032%

1/8Hr

0.007%

1/day

0.001%

1/2day

1) All the above data are estimated value, especial the rapping mechanism. It should be
adjusted iterative according to actual working condition.
2) Each rapping time is 1.5 mins
Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
2) Emitting Rapping System
In general, discharge electrodes should be kept as free as possible of accumulated
particulate. The rapping system for the discharge electrodes should be operated on
a continuous schedule with repeat times in the 2 - 4 minute range, depending on
the size and inlet particulate loading of the precipitator.

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
3) Rapping System for Distribution Screen
The gas distribution plates should also be kept free of excessive particulate buildup
and may require rapping on a continuous base with a cycle time in the 10-20 minute
range, depending on the inlet particulate loading of the precipitator and the nature of
the particulate. Gas distribution plates in the outlet of the precipitator may be rapped
less often (every 30 - 60 minutes).

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
4) Bottom Hopper
Precipitator hoppers are designed to completely discharge dust load on demand.
Typically, precipitator hoppers are rectangular in cross-section with sides of at least
60-degree slope. These hoppers are insulated from the neck above the discharge
flange with the insulation covering the entire hopper area. In addition, baffles are
provided in the hopper to avoid the seepage.

5650mm

8400mm

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Hopper

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

Wednesday, August 19, 2015


3

2 x 600 MW Mahan Thermal Power Project


9

X to Y 7th
FIELD
Y to V 8th
FIELD

V to W 9th
FIELD

U to X 6th
FIELD

T to U 5th
FIELD

S to T 4th
FIELD

R to S 3nd
FIELD

Q to R 2nd
FIELD

P to Q - 1st FIELD

Emitting electrodes - RSB Wire

ARRANGEMENTS: ESP 1 PASS

12.7m/s

ESP 1ST PASS

ELECTROSTATIC PRECIPITATOR
Emitting electrodes - Spiral Wire

12.4m/s

ELECTROSTATIC PRECIPITATOR
COLLECTING & EMITTING PLATE ARRANGEMENT FOR 1ST TO 6TH FIELD.
Emitting plate 4 layers
Collecting plate

EACH HEIGHT OF THE COLLECTING PLATE

15 M

EACH HEIGHT OF THE RSB WIRE

3.581 M

DETAILS OF COLLECTING ELECTRODE


NO. OF COLLECTING ELECTRODE IN HALF FIELD (8*43)

344 No's

NO. OF COLLECTING ELECTRODE IN ONE FIELD

688 No's

NO. OF COLLECTING ELECTRODE IN SINGLE PASS (688*9)

6192 No's

NO. OF COLLECTING ELECTRODE IN TWO PASS (6192*2)

12384 No's

200mm 200mm
400mm

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
COLLECTING & EMITTING PLATE ARRANGEMENT FOR 1ST TO 6TH FIELD.

DETAILS OF EMITTING ELECTRODES (RSB WIRE)

NO. OF RSB WIRE BETWEEN TWO COLLECTING ELECTRODE

No's

NO. OF RSB WIRE IN HALF FIELD

No's

1344

NO. OF RSB WIRE IN ONE FIELD

No's

2688

NO. OF RSB WIRE IN SINGLE PASS FROM 1st TO 6th FIELD(2688*6)

No's

16128

NO. OF RSB WIRE IN TWO PASS FROM 1st TO 6th FIELD(16128*2)

No's

32256

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
COLLECTING & EMITTING PLATE ARRANGEMENT FOR 7TH TO 9TH FIELD
Emitting plate 4 layers
Collecting plate
DETAILS OF EMITTING ELECTRODES (SPIRAL WIRE)

NO. OF SPIRAL BETWEEN TWO COLLECTING ELECTRODE

No's

NO. OF SPIRAL WIRE IN HALF FIELD

No's

2688

NO. OF SPIRAL WIRE IN ONE FIELD (2688*2)

No's

5376

NO. OF SPIRAL WIRE IN SINGLE PASS FROM 7th TO 9th FIELD(5376*3)

No's

16128

NO. OF SPIRAL WIRE IN TWO PASS FROM 7th TO 9th FIELD

No's

32256

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

COLLECTING PLATE SUPPORTED ARRANGEMENT

Collecting Plate

Emitting Plate

Guide Bar
Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

COLLECTING FRAME

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Collecting System
COLLECTING FRAME

COLLECTING PLATE

SHAFT
RAPPER

SHOCK BAR

Wednesday, August 19, 2015

AVIL PLATE

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Emitting System Support:

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

Emitting System Support:

TEMPORARY HANGER BOLT

HANGER BOLT

SUPPORT INSULATOR
CHANNEL WITH INNER ROOF

BEAM

BEAM

VERTICAL BOX

HORIZONTAL
EMITTING FRAME

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

SUPPORT INSULATOR AT FOUR


CORNERS

SUPPORT INSULATOR AT FOUR


CORNERS

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
VERTICAL VIEW OF EMITTING SYSTEM SUPPORTTED
VERTICAL BOX

HORIZONTAL
EMITTING FRAME

EMITTING
ELECTRODE (RSB

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

EMITTING FRAME FOR 1ST to 6TH FIELD:


Emitting Frame
TOP VIEW OF EMITTING FRAME

Emitting Frame

RSB Electrode

Collecting Electrode

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

VERTICAL BOX

INNER WALK WAY

EMITTING FRAME

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
EMITTING FRAME FOR 7TH TO 9TH FIELD:

Emitting Frame

Spiral Electrode

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

Collecting Electrode

ELECTROSTATIC PRECIPITATOR

HORIZONTAL
EMITTING
FRAME

VERTICAL BOX

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
HV inlet:

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
BASIC PRINCIPLES: Electrostatic precipitation removes particles from the exhaust gas stream by Six activities
typically and they are

1) Ionization
2) Migration/Drift Velocity

3) Precipitation.
4) Charge Dissipation
5) Particle Dislodging
6) Particle Removal

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
1.Electron emission

2.Dust particle charging/


corona formation

Dust layer

2
3.Migration

Collecting
electrode,
grounded

5.Rapping

5
Discharge electrode with
Negative high tension volatge (72 KV)

Wednesday, August 19, 2015

4
4. Precipitation

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Working Principle:
The high voltage supply (72 KV) is applied to the Field, the discharge electrode emits the
negatively charged ions.
Particles suspended in a gas enter the precipitator and pass through ionized zones
around the high voltage discharge electrodes, the particles are get ionized with negative
and positive charged ions. This is called as Corona Formation

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
The negatively charged gas field around each electrode charges the particles causing them to
migrate to the electrodes of opposite polarity, i.e. the collecting electrodes.
The charged particles gather on the grounded collecting plates. Rappers dislodge the
gathered particulate, which falls into the collection hoppers for removal.

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

ESP TERMINOLOGY

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
TECHNICAL SPECIFICATION: [General Information about ESP]
S. No

Description

Data

Manufacturer

SUNYARD

Type and No.

2SY504-9

Overall dimensions (L X W X H)

Number of ESP / Steam generator

2/1

Number of gas stream / ESP

2/1

Number of electrical fields in series in gas path / stream

9/1

Total active treatment length per stream (in m)

36

Treatment time (In sec)

Corona power per ESP stream (watts per 1000 m3 per min)
No. of hours ESP can run at specified gas flow and dust loading
without emptying any hopper (hrs)

10

11

Total power input to the ESP per steam Generator

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

73.9353.1533.7m

40.9
49
2
4400 KW

ELECTROSTATIC PRECIPITATOR
FLUE GAS:
S. NO

1
2
3

4
5

DESCRIPTION

UOM

FLUE GAS
Flue gas amount at inlet of E.S.P

m3/hr

Flue gas temperature at inlet of E.S.P

1604198

1696002

136

135

1.34

1.333

g / Nm3

63.573

74.931

mg / Nm3

50mg/Nm3

50mg/Nm3

oC

Excess air coefficient at inlet of E.S.P


Dust concentration of flue gas at inlet of E.S.P

Dust concentration at the ESP outlet

Wednesday, August 19, 2015

DESIGN COAL WORST COAL

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
COLLECTING ELECTRODE SPECIFICATION
S. No

Description

Data

Type

480C

Material

SPCC

Electrode thickness (mm)

1.5

Clear distance between collecting electrode plates(mm )

400

Active length per electrode (in m)

0.48

Cross sectional area of each passage (in m2)

Active height per electrode(in m )

Specific collection plate area (m2/m3/sec)

Total number of electrodes per SG

10

Aspect ratio length / height

2.24

11

Average gas velocity in the electrical field(m/s )

0.88

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

5042

15
204.1

26192

ELECTROSTATIC PRECIPITATOR
DISCHARGE ELECTRODE SPECIFICATION
S. No

Description

Data
I to VI field RSB,I to IX
field spiral wire.
I to VI field SPCC,I to IX
field stainless steel.

Type

Material

Total number of electrodes / SG (RSB Wire)

2 X 16128

Total number of electrodes / SG (Spiral Wire)

2 X 16128

Electrode dimension height (m)

3.581

Effective length of electrode(m)

15

High Voltage Conductor


7

Manufacturer

Type

taper

Size

150x400mm

Wednesday, August 19, 2015

SUNYARD

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
BUS SECTION SPECIFICATION
S. No

Description

Data

Total numbers

36

Number of bus sections in parallel in gas path

Number of sections in parallel in gas path

HT Voltage [kV (peak)]

72

Total power on HT electrode(kW)

Number of sections lost if one transformer is out of service

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

4400KW
1/2

ELECTROSTATIC PRECIPITATOR
COLLECTING RAPPER SPECIFICATION

S. No

Description

Data
Side driven, flexible arm
rapper.

Type

Total no. of rapper drive

3
4

Total number of rappers per SG


Maximum number of electrodes rapped by a rapper at any one
time

Percentage of plates rapped at one time ( % )

50

Rapping acceleration force minimum / plate(g )

150

Average input rapping power to rapping system (kW )

Rapper controller type

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

2 x 18 nos

2 x 774 Nos
8

13.32
electronic program

ELECTROSTATIC PRECIPITATOR
DISCHARGE RAPPER SPECIFICATION
S. No

Description

Data
Top driven, flexible arm
rapper.

Type

Total no. of rapper drive

2 x 18 Nos

Total number of rappers

1476

Percentage of electrodes rapped at any time ( % )

50

Rapping energy of each rapper ( kgs.)

50

Average input power to rapping system ( kW )

Rapper controller type

Wednesday, August 19, 2015

13.32

electronic program

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
TRANSFORMER RECTIFIER UNIT
S. No
1

Description
Total numbers

Data
36

Transformer
2

Type of transformer

Class of insulation

Temperature rise of oil over ambient ( 0C )

Class of bushing

Rating of each set

oil immersed
F
50
35KV

Input power kVA

206 kVA

Output power kW

120 kW

Output Voltage KV

72 KV

Output current mA

Wednesday, August 19, 2015

2000 mA
2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
S. No
10

Description
Volume of oil (Liters )

Data
900 Liters

Rectifier
11

Type

12

Half-wave / full wave

13

Guaranteed life ( hours )

Bridge type

full wave
80000 hours

Rating-each Rectifier unit


14

Number offered

36 sets

15

Type of cabinet

MNS

16

Voltage for controller

17

Arc suppression

18

Protection

19

Instrumentation provided as required

Wednesday, August 19, 2015

AC 110V
2500V

2 x 600 MW Mahan Thermal Power Project

IP42
Volt meters, ampere
meters,

ELECTROSTATIC PRECIPITATOR
POWER CONSUMPTION OF ESP PER SG

S. No

Description

Data

Input power

Output power from TR sets kW

120 Kw/TR

Output voltage KV

72 kV

Output current mA

2000 mA

Total connected load kW

118 kW

Maximum power requirement kW

154 kW

Corona power available Watts / m2

26 Watts / m2

Auxiliary power kW

0.25 kW

Rapping system kW

0.74 kW

10

Seal air fan

0.01 kW

11

Seal air heaters (during start up/ normal) kW

0.05 kW

12

Hopper heaters kW

4.5 kW

Wednesday, August 19, 2015

(kVA )

206 kVA

kW

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
ERECTION SEQUENCE
Check and set out the foundation

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Check and set out the foundation

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Erection of Steel Structures

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Erection of Steel Structures

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Erection of pedestal

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Erection of pedestal

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Erection of pedestal

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Erection of pedestal

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Assemble the ash Hopper

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Assemble the ash Hopper

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Erect the ash hopper

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Erection the Ash hopper

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Erect the casing
CASING STRUCTURE

Wednesday, August 19, 2015

CASING WALL

2 x 600 MW Mahan Thermal Power Project

LRB

TRB

LRB

ELECTROSTATIC PRECIPITATOR

CHANNEL WITH INNERROOF

GABLE WALL

GABLE WALL

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

OUTLET HOOD
DISTRIBUTION SCREEN O/L

GABLE WALL

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

5600/6192 COLLECTING
PLATES ERECTED

PASS A

70

ELECTROSTATIC PRECIPITATOR
10768/6192 COLLECTING
PLATES ERECTED

PASS B

71

ELECTROSTATIC PRECIPITATOR
PASSA

PASSB

5961/12384 COLLECTING
PLATES ERECTED

72

ELECTROSTATIC PRECIPITATOR

Erect the stairs and approaches

Assemble the emitting frame

Lift the emitting hanging beam

Lift the collecting and emitting frame

Check the emitting and collecting


system
Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Install the roof

Install the pressure-bearing insulator

Assemble the inlet funnel

Assemble the outlet funnel

Install the inlet/outlet funnel


Install the heat insulation can and
insulation axis
Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR
Install the HV leading-in wire
Install the top penthouse and lifting
system

Install the rapping system

Install the grounding device


Install and check the electrical
equipment
Install the hopper wall vibrator, ash exhaust, level
indicator and electric heater.
Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project

ELECTROSTATIC PRECIPITATOR

Wednesday, August 19, 2015

2 x 600 MW Mahan Thermal Power Project