Wednesday, August 19, 2015
ELECTROSTATIC PRECIPITATOR
CONTENTS
INTRODUCTION
PRECIPITATOR COMPONENTS
ARRANGEMENTS
BASIC PRINCIPLE
TECHNICAL SPECIFICATION
ERECTION SEQUENCE
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
INTRODUCTION
We are Setting up 2x600 MW Coal Based Thermal Power Plant at Mahan Bandhaura Site.
Electrostatic Precipitator is playing a vital role in most of the industries, such as
1) Thermal Power Plant
2) Cement Plant
3) Chemicals industries
4) Steel Plant
5) Paper Industries & etc
An electrostatic precipitator is a large, industrial emission-control unit. It is designed to
trap and remove dust particles from the exhaust gas stream of an industrial process.
In large power plants may actually have multiple no. of fields for each unit. In our plant,
there are 9 no. of fields per unit.
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
MAJOR COMPONENTS OF ESP:
1) Rectifier Transformer
2) Discharge Electrodes
3) Collecting Electrodes
4) Gas Distribution Systems
5) Rapping system
6) Hopper.
About Rectifier Transformer: The power supply system is designed to provide high voltage to the field to increase the
collection efficiency at the highest possible level
The power supply system has four basic components:
1) Step-up transformer
2) High-voltage rectifier
3) Sensing device
4) Automatic voltage control
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
DESCRIPTION ABOUT THE POWER SUPPLY SYSTEM
The voltage must be controlled to avoid causing sustained arcing or sparking
between the electrodes and the collecting plates
Automatic voltage control varies the power to the transformer-rectifier in response
to signals received from sensors in the precipitator and the transformer-rectifier
itself.
AVR monitors protects the internal components from arc-over damages, and protects
the transformer-rectifier and other components in the primary circuit.
Automatic voltage control would produce the maximum collecting efficiency by
holding the operating voltage of the precipitator at a level just below the spark-over
voltage.
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Spark reaction
When the voltage applied to the field is too high, then spark over will occur.
A voltage controller will monitor the primary and secondary voltage and
current of the circuit, and detect a spark over condition.
Once detected, the power applied to the field will be immediately cut off or
reduced, which will stop the spark.
After a short amount of time the power will be ramped back up, and the process
will start over.
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Tripping
When a condition occurs that the voltage controller cannot control, often times
the voltage controller will trip.
A trip means the voltage controller (by way of the contactor) will shut off the
individual precipitator power circuit.
A short inside the electrostatic precipitator field caused by a fallen discharge
electrode (wire), or a shorted out Silicone Controlled Rectifier are examples of
conditions that a voltage controller cannot control.
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
About Discharge Electrodes: Discharge electrodes emit charging current and provide voltage that generates an
electrical field between the discharge electrodes and the collecting plates.
The particles then precipitate onto the collecting plates. Common types of discharge
electrodes include:
1) Straight round wires
5) Rigid frames
2) Rigid spiked pipes
6) Spiral wires
3) Twisted wire pairs
7) Barbed discharge wires
4) Rigid masts
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Rigid Electrode
Wednesday, August 19, 2015
Spiral Electrode
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
About Collecting Electrodes: Collecting plates are designed to receive and retain the precipitated particles until they
are intentionally removed into the hopper. Collecting plates are also part of the electrical
power circuit of the precipitator.
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
About Gas distribution system:
Gas velocity distribution can be most effectively influenced by the use of gas distribution
devices. Ideally, uniformity is desired in:
1. Gas velocity
2. Gas temperature
3. Dust loading
Gas distribution devices consist of turning vanes in the inlet ductwork and perforated gas
distribution plates and in the outlet fields of the precipitator, flat distribution plate is
used.
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
INLET GD SCREEN
Wednesday, August 19, 2015
OUTLET GD SCREEN
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Rapping System:
To improve collection efficiency and ensure proper functional use of the precipitator,
a rapping system is applied to the collection and emitting electrodes to dislodge the
collected dust layer.
1) Collecting Rapping System:
Collecting plate rapping must remove the bulk of the precipitated dust. The collecting
plates are supported directly with hooks from the precipitator casing.
The impact of the rapping system is directed into the Shock bar located at the leading
and/or trailing edge of the collecting plates.
The first electrical field generally collects about 60-80% of the inlet dust load. So the
first field plates should be rapped often for the every cycle.
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Collecting Rapping System
COLLECTING FRAME
COLLECTING PLATE
SHOCK BAR
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Rapping cycle for the each field as follows:Field No.
Stage Efficiency %
Rapping frequency,
Raps/hr
80%
6/Hr
15%
4/Hr
3%
2/Hr
1.2%
1/Hr
0.55%
1/2Hr
0.11%
1/4Hr
0.032%
1/8Hr
0.007%
1/day
0.001%
1/2day
1) All the above data are estimated value, especial the rapping mechanism. It should be
adjusted iterative according to actual working condition.
2) Each rapping time is 1.5 mins
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
2) Emitting Rapping System
In general, discharge electrodes should be kept as free as possible of accumulated
particulate. The rapping system for the discharge electrodes should be operated on
a continuous schedule with repeat times in the 2 - 4 minute range, depending on
the size and inlet particulate loading of the precipitator.
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
3) Rapping System for Distribution Screen
The gas distribution plates should also be kept free of excessive particulate buildup
and may require rapping on a continuous base with a cycle time in the 10-20 minute
range, depending on the inlet particulate loading of the precipitator and the nature of
the particulate. Gas distribution plates in the outlet of the precipitator may be rapped
less often (every 30 - 60 minutes).
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
4) Bottom Hopper
Precipitator hoppers are designed to completely discharge dust load on demand.
Typically, precipitator hoppers are rectangular in cross-section with sides of at least
60-degree slope. These hoppers are insulated from the neck above the discharge
flange with the insulation covering the entire hopper area. In addition, baffles are
provided in the hopper to avoid the seepage.
5650mm
8400mm
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Hopper
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
Wednesday, August 19, 2015
3
2 x 600 MW Mahan Thermal Power Project
9
X to Y 7th
FIELD
Y to V 8th
FIELD
V to W 9th
FIELD
U to X 6th
FIELD
T to U 5th
FIELD
S to T 4th
FIELD
R to S 3nd
FIELD
Q to R 2nd
FIELD
P to Q - 1st FIELD
Emitting electrodes - RSB Wire
ARRANGEMENTS: ESP 1 PASS
12.7m/s
ESP 1ST PASS
ELECTROSTATIC PRECIPITATOR
Emitting electrodes - Spiral Wire
12.4m/s
ELECTROSTATIC PRECIPITATOR
COLLECTING & EMITTING PLATE ARRANGEMENT FOR 1ST TO 6TH FIELD.
Emitting plate 4 layers
Collecting plate
EACH HEIGHT OF THE COLLECTING PLATE
15 M
EACH HEIGHT OF THE RSB WIRE
3.581 M
DETAILS OF COLLECTING ELECTRODE
NO. OF COLLECTING ELECTRODE IN HALF FIELD (8*43)
344 No's
NO. OF COLLECTING ELECTRODE IN ONE FIELD
688 No's
NO. OF COLLECTING ELECTRODE IN SINGLE PASS (688*9)
6192 No's
NO. OF COLLECTING ELECTRODE IN TWO PASS (6192*2)
12384 No's
200mm 200mm
400mm
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
COLLECTING & EMITTING PLATE ARRANGEMENT FOR 1ST TO 6TH FIELD.
DETAILS OF EMITTING ELECTRODES (RSB WIRE)
NO. OF RSB WIRE BETWEEN TWO COLLECTING ELECTRODE
No's
NO. OF RSB WIRE IN HALF FIELD
No's
1344
NO. OF RSB WIRE IN ONE FIELD
No's
2688
NO. OF RSB WIRE IN SINGLE PASS FROM 1st TO 6th FIELD(2688*6)
No's
16128
NO. OF RSB WIRE IN TWO PASS FROM 1st TO 6th FIELD(16128*2)
No's
32256
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
COLLECTING & EMITTING PLATE ARRANGEMENT FOR 7TH TO 9TH FIELD
Emitting plate 4 layers
Collecting plate
DETAILS OF EMITTING ELECTRODES (SPIRAL WIRE)
NO. OF SPIRAL BETWEEN TWO COLLECTING ELECTRODE
No's
NO. OF SPIRAL WIRE IN HALF FIELD
No's
2688
NO. OF SPIRAL WIRE IN ONE FIELD (2688*2)
No's
5376
NO. OF SPIRAL WIRE IN SINGLE PASS FROM 7th TO 9th FIELD(5376*3)
No's
16128
NO. OF SPIRAL WIRE IN TWO PASS FROM 7th TO 9th FIELD
No's
32256
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
COLLECTING PLATE SUPPORTED ARRANGEMENT
Collecting Plate
Emitting Plate
Guide Bar
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
COLLECTING FRAME
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Collecting System
COLLECTING FRAME
COLLECTING PLATE
SHAFT
RAPPER
SHOCK BAR
Wednesday, August 19, 2015
AVIL PLATE
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Emitting System Support:
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Emitting System Support:
TEMPORARY HANGER BOLT
HANGER BOLT
SUPPORT INSULATOR
CHANNEL WITH INNER ROOF
BEAM
BEAM
VERTICAL BOX
HORIZONTAL
EMITTING FRAME
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
SUPPORT INSULATOR AT FOUR
CORNERS
SUPPORT INSULATOR AT FOUR
CORNERS
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
VERTICAL VIEW OF EMITTING SYSTEM SUPPORTTED
VERTICAL BOX
HORIZONTAL
EMITTING FRAME
EMITTING
ELECTRODE (RSB
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
EMITTING FRAME FOR 1ST to 6TH FIELD:
Emitting Frame
TOP VIEW OF EMITTING FRAME
Emitting Frame
RSB Electrode
Collecting Electrode
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
VERTICAL BOX
INNER WALK WAY
EMITTING FRAME
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
EMITTING FRAME FOR 7TH TO 9TH FIELD:
Emitting Frame
Spiral Electrode
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
Collecting Electrode
ELECTROSTATIC PRECIPITATOR
HORIZONTAL
EMITTING
FRAME
VERTICAL BOX
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
HV inlet:
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
BASIC PRINCIPLES: Electrostatic precipitation removes particles from the exhaust gas stream by Six activities
typically and they are
1) Ionization
2) Migration/Drift Velocity
3) Precipitation.
4) Charge Dissipation
5) Particle Dislodging
6) Particle Removal
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
1.Electron emission
2.Dust particle charging/
corona formation
Dust layer
2
3.Migration
Collecting
electrode,
grounded
5.Rapping
5
Discharge electrode with
Negative high tension volatge (72 KV)
Wednesday, August 19, 2015
4
4. Precipitation
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Working Principle:
The high voltage supply (72 KV) is applied to the Field, the discharge electrode emits the
negatively charged ions.
Particles suspended in a gas enter the precipitator and pass through ionized zones
around the high voltage discharge electrodes, the particles are get ionized with negative
and positive charged ions. This is called as Corona Formation
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
The negatively charged gas field around each electrode charges the particles causing them to
migrate to the electrodes of opposite polarity, i.e. the collecting electrodes.
The charged particles gather on the grounded collecting plates. Rappers dislodge the
gathered particulate, which falls into the collection hoppers for removal.
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
ESP TERMINOLOGY
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
TECHNICAL SPECIFICATION: [General Information about ESP]
S. No
Description
Data
Manufacturer
SUNYARD
Type and No.
2SY504-9
Overall dimensions (L X W X H)
Number of ESP / Steam generator
2/1
Number of gas stream / ESP
2/1
Number of electrical fields in series in gas path / stream
9/1
Total active treatment length per stream (in m)
36
Treatment time (In sec)
Corona power per ESP stream (watts per 1000 m3 per min)
No. of hours ESP can run at specified gas flow and dust loading
without emptying any hopper (hrs)
10
11
Total power input to the ESP per steam Generator
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
73.9353.1533.7m
40.9
49
2
4400 KW
ELECTROSTATIC PRECIPITATOR
FLUE GAS:
S. NO
1
2
3
4
5
DESCRIPTION
UOM
FLUE GAS
Flue gas amount at inlet of E.S.P
m3/hr
Flue gas temperature at inlet of E.S.P
1604198
1696002
136
135
1.34
1.333
g / Nm3
63.573
74.931
mg / Nm3
50mg/Nm3
50mg/Nm3
oC
Excess air coefficient at inlet of E.S.P
Dust concentration of flue gas at inlet of E.S.P
Dust concentration at the ESP outlet
Wednesday, August 19, 2015
DESIGN COAL WORST COAL
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
COLLECTING ELECTRODE SPECIFICATION
S. No
Description
Data
Type
480C
Material
SPCC
Electrode thickness (mm)
1.5
Clear distance between collecting electrode plates(mm )
400
Active length per electrode (in m)
0.48
Cross sectional area of each passage (in m2)
Active height per electrode(in m )
Specific collection plate area (m2/m3/sec)
Total number of electrodes per SG
10
Aspect ratio length / height
2.24
11
Average gas velocity in the electrical field(m/s )
0.88
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
5042
15
204.1
26192
ELECTROSTATIC PRECIPITATOR
DISCHARGE ELECTRODE SPECIFICATION
S. No
Description
Data
I to VI field RSB,I to IX
field spiral wire.
I to VI field SPCC,I to IX
field stainless steel.
Type
Material
Total number of electrodes / SG (RSB Wire)
2 X 16128
Total number of electrodes / SG (Spiral Wire)
2 X 16128
Electrode dimension height (m)
3.581
Effective length of electrode(m)
15
High Voltage Conductor
7
Manufacturer
Type
taper
Size
150x400mm
Wednesday, August 19, 2015
SUNYARD
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
BUS SECTION SPECIFICATION
S. No
Description
Data
Total numbers
36
Number of bus sections in parallel in gas path
Number of sections in parallel in gas path
HT Voltage [kV (peak)]
72
Total power on HT electrode(kW)
Number of sections lost if one transformer is out of service
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
4400KW
1/2
ELECTROSTATIC PRECIPITATOR
COLLECTING RAPPER SPECIFICATION
S. No
Description
Data
Side driven, flexible arm
rapper.
Type
Total no. of rapper drive
3
4
Total number of rappers per SG
Maximum number of electrodes rapped by a rapper at any one
time
Percentage of plates rapped at one time ( % )
50
Rapping acceleration force minimum / plate(g )
150
Average input rapping power to rapping system (kW )
Rapper controller type
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
2 x 18 nos
2 x 774 Nos
8
13.32
electronic program
ELECTROSTATIC PRECIPITATOR
DISCHARGE RAPPER SPECIFICATION
S. No
Description
Data
Top driven, flexible arm
rapper.
Type
Total no. of rapper drive
2 x 18 Nos
Total number of rappers
1476
Percentage of electrodes rapped at any time ( % )
50
Rapping energy of each rapper ( kgs.)
50
Average input power to rapping system ( kW )
Rapper controller type
Wednesday, August 19, 2015
13.32
electronic program
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
TRANSFORMER RECTIFIER UNIT
S. No
1
Description
Total numbers
Data
36
Transformer
2
Type of transformer
Class of insulation
Temperature rise of oil over ambient ( 0C )
Class of bushing
Rating of each set
oil immersed
F
50
35KV
Input power kVA
206 kVA
Output power kW
120 kW
Output Voltage KV
72 KV
Output current mA
Wednesday, August 19, 2015
2000 mA
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
S. No
10
Description
Volume of oil (Liters )
Data
900 Liters
Rectifier
11
Type
12
Half-wave / full wave
13
Guaranteed life ( hours )
Bridge type
full wave
80000 hours
Rating-each Rectifier unit
14
Number offered
36 sets
15
Type of cabinet
MNS
16
Voltage for controller
17
Arc suppression
18
Protection
19
Instrumentation provided as required
Wednesday, August 19, 2015
AC 110V
2500V
2 x 600 MW Mahan Thermal Power Project
IP42
Volt meters, ampere
meters,
ELECTROSTATIC PRECIPITATOR
POWER CONSUMPTION OF ESP PER SG
S. No
Description
Data
Input power
Output power from TR sets kW
120 Kw/TR
Output voltage KV
72 kV
Output current mA
2000 mA
Total connected load kW
118 kW
Maximum power requirement kW
154 kW
Corona power available Watts / m2
26 Watts / m2
Auxiliary power kW
0.25 kW
Rapping system kW
0.74 kW
10
Seal air fan
0.01 kW
11
Seal air heaters (during start up/ normal) kW
0.05 kW
12
Hopper heaters kW
4.5 kW
Wednesday, August 19, 2015
(kVA )
206 kVA
kW
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
ERECTION SEQUENCE
Check and set out the foundation
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Check and set out the foundation
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Erection of Steel Structures
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Erection of Steel Structures
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Erection of pedestal
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Erection of pedestal
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Erection of pedestal
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Erection of pedestal
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Assemble the ash Hopper
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Assemble the ash Hopper
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Erect the ash hopper
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Erection the Ash hopper
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Erect the casing
CASING STRUCTURE
Wednesday, August 19, 2015
CASING WALL
2 x 600 MW Mahan Thermal Power Project
LRB
TRB
LRB
ELECTROSTATIC PRECIPITATOR
CHANNEL WITH INNERROOF
GABLE WALL
GABLE WALL
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
OUTLET HOOD
DISTRIBUTION SCREEN O/L
GABLE WALL
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
5600/6192 COLLECTING
PLATES ERECTED
PASS A
70
ELECTROSTATIC PRECIPITATOR
10768/6192 COLLECTING
PLATES ERECTED
PASS B
71
ELECTROSTATIC PRECIPITATOR
PASSA
PASSB
5961/12384 COLLECTING
PLATES ERECTED
72
ELECTROSTATIC PRECIPITATOR
Erect the stairs and approaches
Assemble the emitting frame
Lift the emitting hanging beam
Lift the collecting and emitting frame
Check the emitting and collecting
system
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Install the roof
Install the pressure-bearing insulator
Assemble the inlet funnel
Assemble the outlet funnel
Install the inlet/outlet funnel
Install the heat insulation can and
insulation axis
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Install the HV leading-in wire
Install the top penthouse and lifting
system
Install the rapping system
Install the grounding device
Install and check the electrical
equipment
Install the hopper wall vibrator, ash exhaust, level
indicator and electric heater.
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project
ELECTROSTATIC PRECIPITATOR
Wednesday, August 19, 2015
2 x 600 MW Mahan Thermal Power Project