50% found this document useful (2 votes)
999 views

RC Slab Design (BS8110)

The document provides details of the design of a reinforced concrete slab, including: - Slab dimensions and reinforcement details - Calculations of required reinforcement areas to resist sagging and shear forces - Checks that the nominal cover and spacing of the reinforcement meets code requirements - Verification that the slab deflection does not exceed code limits - Punching shear checks around a concentrated load The summary provides a high-level overview of the key aspects of the slab design covered in the document in 3 sentences.

Uploaded by

Mike
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
50% found this document useful (2 votes)
999 views

RC Slab Design (BS8110)

The document provides details of the design of a reinforced concrete slab, including: - Slab dimensions and reinforcement details - Calculations of required reinforcement areas to resist sagging and shear forces - Checks that the nominal cover and spacing of the reinforcement meets code requirements - Verification that the slab deflection does not exceed code limits - Punching shear checks around a concentrated load The summary provides a high-level overview of the key aspects of the slab design covered in the document in 3 sentences.

Uploaded by

Mike
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Project

Job Ref.

Section

Sheet no./rev.

1
Calc. by

Date

12/2/2016

Chk'd by

Date

App'd by

Date

RC SLAB DESIGN (BS8110:PART1:1997)


TEDDS calculation version 1.0.04

CONCRETE SLAB DESIGN (CL 3.5.3 & 4)


SIMPLE ONE WAY SPANNING SLAB DEFINITION
;

Overall depth of slab; h = 200 mm

Cover to tension reinforcement resisting sagging; cb = 30 mm

Trial bar diameter; Dtryx = 16 mm


Depth to tension steel (resisting sagging)
dx = h - cb - Dtryx/2 = 162 mm

Characteristic strength of reinforcement; fy = 500 N/mm2

Characteristic strength of concrete; fcu = 40 N/mm2

dx

A sy

N o m in a l 1 m w id th

A sx

O n e -w a y s p a n n in g s la b
(s im p le )
ONE WAY SPANNING SLAB (CL 3.5.4)
MAXIMUM DESIGN MOMENTS IN SPAN
;

Design sagging moment (per m width of slab); msx = 30.8 kNm/m

CONCRETE SLAB DESIGN SAGGING OUTER LAYER OF STEEL (CL 3.5.4)


;

Design sagging moment (per m width of slab); msx = 30.8 kNm/m

Moment Redistribution Factor; bx = 1.0

Area of reinforcement required


;;

Kx = abs(msx) / ( dx2 fcu ) = 0.029


K'x = min (0.156 , (0.402 (bx - 0.4)) - (0.18 (bx - 0.4)2 )) = 0.156
Outer compression steel not required to resist sagging

Slab requiring outer tension steel only - bars (sagging)


;;

zx = min (( 0.95 dx),(dx(0.5+(0.25-Kx/0.9)))) = 154 mm

Project

Job Ref.

Section

Sheet no./rev.

2
Calc. by

Date

12/2/2016

Chk'd by

Date

App'd by

Date

Neutral axis depth; xx = (dx - zx) / 0.45 = 18 mm


Area of tension steel required
;;;

Asx_req = abs(msx) / (1/ms fy zx) = 460 mm2/m

Tension steel
;;Provide 16 dia bars @ 100 centres; outer tension steel resisting sagging
Asx_prov = Asx = 2010 mm2/m
Area of outer tension steel provided sufficient to resist sagging
TRANSVERSE BOTTOM STEEL - INNER
;;Inner layer of transverse steel;
Provide 16 dia bars @ 100 centres
Asy_prov = Asy = 2010 mm2/m
Check min and max areas of steel resisting sagging
;Total area of concrete; Ac = h = 200000 mm2/m
;

Minimum % reinforcement; k = 0.13 %


Ast_min = k Ac = 260 mm2/m
Ast_max = 4 % Ac = 8000 mm2/m

Steel defined:
;

Outer steel resisting sagging; Asx_prov = 2010 mm2/m


Area of outer steel provided (sagging) OK

Inner steel resisting sagging; Asy_prov = 2010 mm2/m


Area of inner steel provided (sagging) OK

SHEAR RESISTANCE OF CONCRETE SLABS (CL 3.5.5)


Outer tension steel resisting sagging moments
;

Depth to tension steel from compression face; dx = 162 mm

Area of tension reinforcement provided (per m width of slab); Asx_prov = 2010 mm2/m

Design ultimate shear force (per m width of slab); Vx = 42 kN/m

Characteristic strength of concrete; fcu = 40 N/mm2

Applied shear stress


vx = Vx / dx = 0.26 N/mm2
Check shear stress to clause 3.5.5.2
vallowable = min ((0.8 N1/2/mm) (fcu ), 5 N/mm2 ) = 5.00 N/mm2
Shear stress - OK
Shear stresses to clause 3.5.5.3
Design shear stress

Project

Job Ref.

Section

Sheet no./rev.

3
Calc. by

Date

12/2/2016

Chk'd by

Date

App'd by

Date

fcu_ratio = if (fcu > 40 N/mm2 , 40/25 , fcu/(25 N/mm2)) = 1.600


vcx = 0.79 N/mm2 min(3,100 Asx_prov / dx)1/3 max(0.67,(400 mm / dx)1/4) / 1.25 fcu_ratio1/3
vcx = 1.00 N/mm2
Applied shear stress
vx = 0.26 N/mm2
No shear reinforcement required
SHEAR PERIMETERS FOR A RECTANGULAR CONCENTRATED LOAD (CL 3.7.7)
;

Length of loaded rectangle; l = 100 mm

Width of loaded rectangle; w = 250 mm

Depth to tension steel; dx = 162 mm


;

Dimension from edge of load to shear perimeter; lp = kp dx = 243 mm; where; kp = 1.50

For punching shear cases not affected by free edges or holes:


Total length of inner perimeter at edge of loaded area; u0_gen = 2 (l + w) = 700 mm
Total length of outer perimeter at lp from loaded area; ugen = 2 (l + w) + 8 lp = 2644 mm
PUNCHING SHEAR AT CONCENTRATED LOADS (CL 3.7.7)
Tension steel resisting sagging
;

Total length of inner perimeter at edge of loaded area; u0 = 700 mm

Total length of outer perimeter at dimension lp from loaded area; u = 2644 mm

Depth to outer steel; dx = 162 mm

Depth to inner steel; dy = 10 mm


Average depth to "tension" steel; dav = (dx + dy)/2 = 86.0 mm

Area of outer steel per m effective through the perimeter; Asx_prov = 2010 mm2 /m

Area of inner steel per m effective through the perimeter; Asy_prov = 2010 mm2 /m

Max shear effective across either perimeter under consideration; Vp = 42 kN

Characteristic strength of concrete; fcu = 40 N/mm2

Applied shear stress


Stress around loaded area; vmax = Vp / (u0 dav) = 0.698 N/mm2
Stress around perimeter; v = Vp / (u dav) = 0.185 N/mm2
Check shear stress to clause 3.7.7.2
vallowable = min ((0.8 N1/2/mm) (fcu ), 5 N/mm2 ) = 5.000 N/mm2
Shear stress - OK
Shear stresses to clause 3.7.7.4

Project

Job Ref.

Section

Sheet no./rev.

4
Calc. by

Date

12/2/2016

Chk'd by

Date

App'd by

Date

Design shear stress


fcu_ratio = if (fcu > 40 N/mm2 , 40/25 , fcu/(25 N/mm2)) = 1.600
;

Effective steel area for shear strength determination:; As_eff =2680 mm2/m;
vc = 0.79 N/mm2 min( 3, 100( As_eff / dav ) )1/3 max(0.67, (400 mm / dav )1/4) / 1.25 fcu_ratio1/3
vc = 1.566 N/mm2
No shear reinforcement required

CONCRETE SLAB DEFLECTION CHECK (CL 3.5.7)


;

Slab span length; lx = 3.000 m

Design ultimate moment in shorter span per m width; msx = 31 kNm/m

Depth to outer tension steel; dx = 162 mm


Tension steel

Area of outer tension reinforcement provided; Asx_prov = 2010 mm2/m

Area of tension reinforcement required; Asx_req = 460 mm2/m

Moment Redistribution Factor; bx = 1.00

Modification Factors
;Basic span / effective depth ratio (Table 3.9); ratiospan_depth = 26
The modification factor for spans in excess of 10m (ref. cl 3.4.6.4) has not been included.
;fs = 2 fy Asx_req / (3 Asx_prov bx ) = 76.3 N/mm2
factortens = min ( 2 , 0.55 + ( 477 N/mm2 - fs ) / ( 120 ( 0.9 N/mm2 + msx / dx2))) = 2.000
Calculate Maximum Span
This is a simplified approach and further attention should be given where special circumstances exist. Refer to clauses 3.4.6.4
and 3.4.6.7.
Maximum span; lmax = ratiospan_depth factortens dx = 8.42 m
Check the actual beam span
Actual span/depth ratio; lx / dx = 18.52
Span depth limit; ratiospan_depth factortens = 52.00
Span/Depth ratio check satisfied
CHECK OF NOMINAL COVER (SAGGING) (BS8110:PT 1, TABLE 3.4)
;

Slab thickness; h = 200 mm

Effective depth to bottom outer tension reinforcement; dx = 162.0 mm

Diameter of tension reinforcement; Dx = 16 mm

Project

Job Ref.

Section

Sheet no./rev.

Calc. by

Date

12/2/2016

Chk'd by

Date

App'd by

Date

Diameter of links; Ldiax = 0 mm

Cover to outer tension reinforcement


ctenx = h - dx - Dx / 2 = 30.0 mm
Nominal cover to links steel
cnomx = ctenx - Ldiax = 30.0 mm
Permissable minimum nominal cover to all reinforcement (Table 3.4)
;

cmin = 30 mm
Cover over steel resisting sagging OK