Differential protection is commonly provided for power transformers rated over 5MVA. Differential relays can detect faults inside the transformer that Buchholz relays may miss, such as flashovers at bushings. Differential relays also respond faster to internal faults than Buchholz relays. Differential protection works by comparing the primary and secondary currents of the transformer - under normal operation the currents oppose each other, but a fault causes an imbalance that triggers the relay.
Download as DOCX, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
128 views
Differential Protection of Transformer Differential Relays
Differential protection is commonly provided for power transformers rated over 5MVA. Differential relays can detect faults inside the transformer that Buchholz relays may miss, such as flashovers at bushings. Differential relays also respond faster to internal faults than Buchholz relays. Differential protection works by comparing the primary and secondary currents of the transformer - under normal operation the currents oppose each other, but a fault causes an imbalance that triggers the relay.
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2
Differential Protection of
Transformer | Differential Relays
Previous Next Generally Differential protection is provided in the electrical power transformer rated more than 5MVA. The Differential Protection of Transformer has many advantages over other schemes of protection. 1) The faults occur in the transformer inside the insulating oil can be detected by Buchholz relay. But if any fault occurs in the transformer but not in oil then it can not be detected by Buchholz relay. Any flash over at the bushings are not adequately covered by Buchholz relay. Differential relays can detect such type of faults. Moreover Buchholz relay is provided in transformer for detecting any internal fault in the transformer but Differential Protection scheme detects the same in more faster way. 2) The differential relays normally response to those faults which occur in side the differential protection zone of transformer.
Differential Protection Scheme in a Power
Transformer Principle of Differential Protection Principle of Differential Protection scheme is one simple conceptual technique. The differential relay actually compares between primary current and secondary current of power transformer, if any unbalance found in between primary and secondary currents the relay will actuate and inter trip both the primary and secondary circuit breaker of the transformer. Suppose you have one transformer which has primary rated current Ip and secondary current Is. If you install CT of ratio Ip/1A at the primary side and similarly, CT of ratio Is/1A at the secondary side of the transformer. The secondaries of these both CTs are connected together in such a manner that secondary currents of both CTs will oppose each other. In other words, the secondaries of both CTs should be connected to the same current coil of a differential relay in such an opposite manner that there will be no resultant current in
that coil in a normal working condition of the transformer. But if any
major fault occurs inside the transformer due to which the normal ratio of the transformer disturbed then the secondary current of both transformers will not remain the same and one resultant current will flow through the current coil of the differential relay, which will actuate the relay and inter trip both the primary and secondary circuit breakers. To correct phase shift of current because of star - delta connection of transformer winding in the case of three-phase transformer, the current transformer secondaries should be connected in delta and star as shown here.
At maximum through fault current, the spill output produced by the
small percentage unbalance may be substantial. Therefore, differential protection of transformer should be provided with a proportional bias of an amount which exceeds in effect the maximum ratio deviation.