DM7486 Quad 2-Input Exclusive-OR Gate: General Description
DM7486 Quad 2-Input Exclusive-OR Gate: General Description
DM7486
Quad 2-Input Exclusive-OR Gate
General Description
This device contains four independent gates each of which
performs the logic exclusive-OR function.
Ordering Code:
Order Number
DM7486N
Package Number
N14A
Package Description
14-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300" Wide
Connection Diagram
Function Table
Y=AB
Inputs
Output
Y
L
DS006531
www.fairchildsemi.com
September 1986
DM7486
Note 1: The Absolute Maximum Ratings are those values beyond which
the safety of the device cannot be guaranteed. The device should not be
operated at these limits. The parametric values defined in the Electrical
Characteristics tables are not guaranteed at the absolute maximum ratings.
The Recommended Operating Conditions table will define the conditions
for actual device operation.
7V
Input Voltage
5.5V
0C to +70C
65C to +150C
Parameter
Min
Nom
Max
4.75
5.25
Units
VCC
Supply Voltage
VIH
VIL
0.8
IOH
0.8
mA
IOL
16
mA
TA
70
Electrical Characteristics
over recommended operating free air temperature range (unless otherwise noted)
Symbol
Parameter
Conditions
VI
VCC = Min, II = 12 mA
VOH
HIGH Level
Output Voltage
LOW Level
Output Voltage
VOL
Min
2.4
Typ
(Note 2)
Max
Units
1.5
3.4
0.2
0.4
V
mA
II
IIH
40
IIL
1.6
mA
IOS
55
mA
ICCH
30
50
mA
ICCL
36
57
mA
18
Switching Characteristics
at VCC = 5V and TA = 25C
Symbol
Parameter
Conditions
CL = 15 pF, RL = 400
Min
tPLH
tPHL
tPHL
ns
17
ns
30
ns
22
ns
www.fairchildsemi.com
23
Other Input LOW
Units
Max
Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and
Fairchild reserves the right at any time without notice to change said circuitry and specifications.
LIFE SUPPORT POLICY
FAIRCHILDS PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD
SEMICONDUCTOR CORPORATION. As used herein:
2. A critical component in any component of a life support
device or system whose failure to perform can be reasonably expected to cause the failure of the life support
device or system, or to affect its safety or effectiveness.
www.fairchildsemi.com
www.fairchildsemi.com