World Standard Performance: Waterproof Jelly Formulation

SCC manufactures metallic telecommunication cables that are designed to perform optimally in harsh environmental conditions. The cables are made from high quality materials according to international standards and specifications. SCC is continually improving its cable production processes and techniques to enhance performance reliability and durability. Specific features include special jelly and moisture barrier formulations and materials to protect cables installed underground or in high temperature environments.

Uploaded by

HOFFER
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views32 pages

World Standard Performance: Waterproof Jelly Formulation

SCC manufactures metallic telecommunication cables that are designed to perform optimally in harsh environmental conditions. The cables are made from high quality materials according to international standards and specifications. SCC is continually improving its cable production processes and techniques to enhance performance reliability and durability. Specific features include special jelly and moisture barrier formulations and materials to protect cables installed underground or in high temperature environments.

Uploaded by

HOFFER
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

WORLD

STANDARD

PERFORMANCE

SCCs metallic telecommunication cables are designed for optimum performance in


some of the worlds toughest environmental conditions. All cables outlined in this
brochure are manufactured with high grade materials to international standards such
as IEC, ASTM, REA, BS, SA-MOPTT MAT, etc., and are all fully compliant with the
stringent electrical, mechanical, physical and performance requirements demanded
of them.
SCC is continually evolving new processes and techniques to enhance cable
performance. This policy has resulted in a number of specific features to maximise
cable reliability and durability across the product range.

WA T E R P R O O F J E L LY
F O R M U L AT I O N

SCC has adopted a special jelly


compound for filled telephone cables,
specifically formulated for the high
temperature

environment

of

the

Middle East.

M O I S T U R E B A R R I E R S H E AT H S

SCC underground filled cables and


buried service wires both feature
special moisture resistant sheaths.
Aluminium polymer laminated tape,
coated on both sides with polyolefine,
is applied longitudinally with an overlap
in order to provide a moisture barrier
under the sheath. The special adhesive
polyolefine coating is fused to and
strongly bonded to the overlaying
weather-resistant polyethylene sheath.

P A G E

O N E

BURIED CABLES - ADDED PROTECTION

Buried cables are particularly vulnerable to water entry after installation. Water penetration typically occurs through non-watertight
splices, or following attacks by burrowing animals or damage by excavation machinery.
Even small amounts of water in a telephone cable can adversely affect cable performance.
Water in a telephone cable increases the mutual capacitance which in turn increases the
transmission losses.
Depending on the application, SCC can offer extra protection from moisture. In such cases,
SCC utilises a special water blocking (swellable) tape to provide extra protection against
longitudinal water penetration for all polyethylene insulated cables. This tape is then reinforced
with a tough, weather-resistant, polyethylene sheath
making SCC PE insulated cables perfectly suitable for
direct burial applications.
SCC PE or PVC insulated cables can also be provided
with additional steel armour for added protection against
physical attack.

Subscriber
Subscriber Cable
Distribution Point
Secondary Cable
Cross-connection Cabinet

Primary Cable

Local Exchange
Junction Network

Trunk Connection

Subscriber
Subscriber Cable
Distribution Point
Secondary Cable
Cross-connection Cabinet

Primary Cable

Local Exchange
Junction Network

Trunk Connection

CONTENTS

3 Metallic cable product codes

16 Flame retardant indoor


telephone cable

4 Underground (duct) filled local


telephone cable

18 Self supporting aerial cable

6 Underground (direct buried) filled


local telephone cable

20 Buried service wire


22 Drop wire

9 Underground (duct) pressurized


local telephone cable

24 Jumper wire

10 Underground (direct buried)


pressurized local telephone cable

28 Indoor wire (Type-A)


29 Indoor wire (Type-B)

12 Stub telephone cable

M E TA L L I C C A B L E P R O D U C T C O D E S T R U C T U R E

1 S T PA R T
Fixed

CABLE DESIGN

Plain Ann. Cu Solid Cond.


Tinned Ann. Cu Solid Cond.
Hard Drawn Cu Solid Cond.
Copper Clad Steel Wire

Jelly filled
A
K
E
V
X

Unfilled
U PE Solid
Y PE Foam
I
PE Foam + Skin
O PVC
X Non-Standard

9
B
F
N
S
T
M
X

nxpxd

3 R D PA R T
Cable Size

N o . X PA I R X D I A .

40 nF/KM
42 nF/KM
44 nF/KM
52 nF/KM
55 nF/KM
75 nF/KM
Non-Standard

A
C
S
X

Polymer Coated Aluminium Tape


Fully Annealed Copper Tape
Fully Annealed Copper Clad Stainless Steel Tape
Non-Standard

S H E AT H I N G M AT E R I A L S

C A PA C I TA N C E

S C R E E N M AT E R I A L S

I N S U L AT I O N

P
T
D
C

M AT E R I A L A P P L I C AT I O N

CONDUCTOR

2 N D PA R T
Interchangeable Unlimited

A L P H A B E T I C A L PA R T O F P R O D U C T C O D E S T R U C T U R E

L
M
H
V
F
N

Low Density Polyethylene (LDPE)


Medium Density Polyethylene (MDPE)
High Density Polyethylene (HDPE)
Polyvinyl Chloride (PVC)
Low Smoke Halogen-Free (LSHF)
Nylon Jacket

A R M O U R I N G M AT E R I A L S
G
Z
W
N

Galvanised Steel Tape


Polymer Coated Steel Tape
Galvanised Steel Wire
Non-Standard

O T H E R M AT E R I A L S

O
I
P

Stranded Steel Wires Core Messenger (SS Cable)


Insulated Copper Wires
Insulated Copper Pairs

STRANDING

C
R
J
Z
Q
O

Conventional Stranding (Group)


Cross Stranding (Group)
Individual Pairs Concentric Layer
S-Z Stranding (Group)
Quad Stranding
Others (Parallel) (Twisted Pair)

EXAMPLE
PENRALGL
Plain annealed Copper conductor, Foam-skin, Jelly filled, Cross-stranded, Polymer coated
aluminium tape screen, LDPE Jacket, Galvanised double steel tape armour, LDPE outer
jacket, 44 nF/KM average mutual capacitance.

UNDERGROUND

(DUCT) FILLED LOCAL


TELEPHONE CABLE

1.

Copper Conductor

4.

Identification Tape

7.

Aluminium Moisture Barrier

2.

Polyethylene (Foam Skin) Insulation

5.

Wrapping Tape

8.

Polyethylene Sheath, Black

3.

Filling Compound

6.

Flooding Compound

9.

Sheath Marking

DUCT

PRODUCT CODE

PENRAL/PENZAL

TECH. SPEC. NO.

TS - 18000

SAUDI CABLE COMPANY

A P P L I C AT I O N

Polyethylene insulated water proof (jelly filled) cables are generally used for primary and secondary underground distribution networks. The
cables are generally hauled in ducts.

DESCRIPTION

Plain annealed copper solid conductor, high density cellular (foam-skin) polyethylene insulated, paired, unit type, jelly filled, screened and
polyethylene sheathed, duct local telephone cable (CEF) Complying with MOPTT MAT-1101 specification.

D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

Approx. Outer
Dia. (mm)

Approx.
Gross Wt.
(kgs)

Shipping
Length
(+5/-0m)

Reel Size
(Flange Dia.)
(mm)

100047
100048
101607
100049
100050
100130
100051
101608
100052
100053
100054
100055
100056
100057
101796

10
20
30
50
100
150
200
250
300
600
900
1,200
1,500
1,800
2,400

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40

9.5
11.5
13.0
15.0
19.5
23.5
26.5
29.0
31.0
42.0
51.0
58.0
64.5
70.0
80.5

118
162
224
318
550
790
1,018
1,214
1,450
1,698
2,502
1,650
2,095
2,478
3,214

1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
600
600
300
300
300
300

800
800
900
1,000
1,100
1,300
1,500
1,500
1,600
1,700
2,000
1,800
2,000
2,100
2,300

100058
100059
100131
100060
100132
100061
100133
100062
100063
100134

10
20
30
50
70
100
150
200
300
400

x
x
x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x
x
x

0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

11.0
13.0
15.0
18.0
20.0
24.0
28.0
32.0
38.0
43.0

150
232
302
460
590
814
1,150
1,562
1,328
1,756

1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
600
600

800
900
1,000
1,100
1,200
1,300
1,500
1,700
1,600
1,800

Continued.....

S A U D I
P A G E

F O U R

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

UNDERGROUND

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

100064
101443
100065
100066
101792
103387

600
800
900
1,200
1,500
1,800

x
x
x
x
x
x

2
2
2
2
2
2

x
x
x
x
x
x

101325
101326
101327
101328
101329
101393
101330
101331
101988
101332
101333
101334

10
20
30
50
100
150
200
300
400
600
900
1,200

x
x
x
x
x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2
2
2
2
2

101301
101302
101842
101303
101304
101305
101306
101307

10
20
30
50
100
150
200
300

x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2

(DUCT) FILLED LOCAL


TELEPHONE CABLE
PRODUCT CODE

PENRAL/PENZAL

TECH. SPEC. NO.

TS - 18000

Approx. Outer
Dia. (mm)

Approx.
Gross Wt.
(kgs)

Shipping
Length
(+5/-0m)

Reel Size
(Flange Dia.)
(mm)

0.50
0.50
0.50
0.50
0.50
0.50

52.0
59.5
63.0
72.5
80.0
87.0

2,638
1,774
1,956
2,580
3,150
3,744

600
300
300
300
300
300

2,100
1,900
1,900
2,100
2,300
2,400

x
x
x
x
x
x
x
x
x
x
x
x

0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65

13.0
16.0
18.5
23.5
31.0
37.0
42.5
51.0
58.0
70.0
85.0
96.0

220
364
480
740
810
1,220
1,612
2,366
3,096
2,344
3,420
4,565

1,000
1,000
1,000
1,000
600
600
600
600
600
300
300
300

900
1,100
1,100
1,300
1,300
1,600
1,800
2,000
2,300
2,100
2,400
2,500

x
x
x
x
x
x
x
x

0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90

16.0
20.5
25.0
31.0
42.0
51.0
58.0
70.5

360
375
524
786
1,554
2,304
1,518
2,298

1,000
600
600
600
600
600
300
300

1,100
1,100
1,200
1,300
1,700
2,000
1,800
2,100

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

P A G E

F I V E

UNDERGROUND

(DIRECT BURIED) FILLED


LOCAL TELEPHONE CABLE

1.

Copper Conductor

4.

Identification Tape

8.

Inner Polyethylene Sheath, Black

2.

Polyethylene (Foam Skin)

5.

Wrapping Tape

9.

Flooding Compound

Insulation

6.

Flooding Compound

10. Outer Polyethylene Sheath, Black

Filling Compound

7.

Aluminium Moisture Barrier

11. Sheath Marking

3.

11

10

PRODUCT CODE

PENRALL/PENZALL

TECH. SPEC. NO.

TS - 18000

SAUDI CABLE COMPANY

A P P L I C AT I O N

Polyethylene insulated water proof (jelly filled) cables are generally used for primary and secondary underground distribution networks. The
cables are for direct burial applications.

DESCRIPTION

Plain annealed copper solid conductor, high density cellular (foam-skin) polyethylene insulated, paired, unit type, jelly filled, screened and
polyethylene (inner & outer) sheathed direct buried local telephone cable (CEFE) Complying with MOPTT MAT-1101 specification.

D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

Approx. Outer
Dia. (mm)

Approx.
Gross Wt.
(kgs)

Shipping
Length
(+5/-0m)

Reel Size
(Flange Dia.)
(mm)

100081
100082
100138
100083
100084
100085
100086
100139
100087
100088
100089
100090
100091
103109

10
20
30
50
100
200
300
400
600
900
1,200
1,500
1,800
2,400

x
x
x
x
x
x
x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x
x
x
x
x
x
x

0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40

13.0
14.5
16.0
18.5
23.0
30.0
34.5
38.5
45.5
54.5
61.5
68.0
73.5
83.5

190
246
324
424
674
1,200
1,682
2,198
1,830
2,730
1,804
2,192
2,585
3,335

1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
600
600
300
300
300
300

900
1,000
1,100
1,100
1,300
1,600
1,800
2,000
1,800
2,200
1,900
2,000
2,100
2,300

100092
100093
100140
100094
100095
100096
100097
100098
100099
100100
100902

10
20
30
50
100
200
300
600
900
1,200
1,500

x
x
x
x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x
x
x
x

0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

14.5
16.5
18.5
21.0
27.5
35.0
41.5
55.5
66.5
76.0
83.5

232
332
410
564
968
1,732
1,510
2,818
2,088
2,690
3,274

1,000
1,000
1,000
1,000
1,000
1,000
600
600
300
300
300

1,000
1,100
1,100
1,200
1,500
1,800
1,700
2,200
2,000
2,100
2,300

Continued.....

S A U D I
P A G E

S I X

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

UNDERGROUND

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

(DIRECT BURIED) FILLED


LOCAL TELEPHONE CABLE
PRODUCT CODE

PENRALL/PENZALL

TECH. SPEC. NO.

TS - 18000

Approx. Outer
Dia. (mm)

Approx.
Gross Wt.
(kgs)

Shipping
Length
(+5/-0m)

Reel Size
(Flange Dia.)
(mm)

101335
101336
101337
101338
101339
101340
101341
101342
101343
101344
101345

10
20
30
50
100
150
200
300
400
600
900

x
x
x
x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x
x
x
x

0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65

16.0
19.5
22.0
26.5
34.5
40.5
45.5
54.5
61.5
73.5
88.0

318
460
598
890
935
1,398
1,806
2,575
3,352
2,450
3,350

1,000
1,000
1,000
1,000
600
600
600
600
600
300
300

1,100
1,200
1,300
1,500
1,500
1,700
1,900
2,100
2,400
2,100
2,400

101308
101309
101310
101311
101312
101313
101314
101082

10
20
30
50
100
150
200
300

x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x

0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90

19.5
24.0
28.5
34.0
45.0
54.0
61.0
73.5

454
442
615
910
1,688
2,514
1,672
2,404

1,000
600
600
600
600
600
300
300

1,200
1,100
1,300
1,500
1,800
2,100
1,900
2,100

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

P A G E

S E V E N

ELECTRICAL

Conductor Resistance at 20C (Ohms/Km)


Conductor
size (mm)

Maximum DC Resistance
Average
Individual

0.40
0.50
0.65
0.90

144
92
54
28

CHARACTERISTICS

4.2 Pair to Pair Between Adjacent Sub-Units or Units


(pF/500 M)
Maximum Average : 17
Maximum Individual : 55

4.3 Pair to Earth (pF/Km)


Maximum Average : 500
Maximum Individual : 2,500

150
96
57
30

1.1 Resistance Unbalance


5

Dielectric strength DC Volts (for 3 sec. min.)

Conductor
size (mm)

Maximum Resistance
Unbalance (%)
Average
Individual

Conductor
size (mm)

Between
Conductor

Conductor
to Shield

0.40
0.50
0.65
0.90

1.00
0.75
0.75
0.75

0.40
0.50
0.65
0.90

2,400
2,400
3,000
3,600

5,000
5,000
10,000
10,000

2.5
2.5
2.0
2.0

Attenuation
The maximum average attenuation at
two spot frequencies shall not exceed
the values given below:
Conductor
size (mm)

Maximum Average
Attenuation (dB/Km)
1 KHz
1 MHz

0.40
0.50
0.65
0.90

1.81
1.45
1.10
0.80

25.7
21.0
16.3
13.6

Percent unbalance shall be calculated by


means of the following formula.
Rmax. - Rmin.
R% =

The pair-to-pair Near-End (NEXT)


coupling loss of 99% of pair
combinations shall exceed the values
given below:

Rmax. + Rmin.

Insulation Resistance at 20C


The I.R. shall be not less than 2,500
mega-ohms km.

Frequency
(KHz)

NEXT
(dB/Km)

1
12
80
1,000

85
80
67
48

Mutual Capacitance at 1,000 200 Hz (nF/Km)


6.1 Near End (NEXT) & Equal Level Far
End (ELFEXT) Limits
The NEXT and ELFEXT individual
power sums shall exceed the
values given below:

Nominal Average : 44 2
Maximum Individual : 50

Near End Crosstalk (NEXT) Limits

x100

Capacitance Unbalance at 1,000 200 Hz

4.1 Pair to Pair Within a Sub-unit (pF/500M)


Maximum Average : 25
Maximum Individual : 150

S A U D I
P A G E

E I G H T

Frequency
(KHz)

NEXT
(dB/Km)

ELFEXT
(dB/Km)

1
12
80
1,000

70
67
55
37

74
71
58
36

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

UNDERGROUND (DUCT) PRESSURIZED


LOCAL TELEPHONE CABLE

1.

Copper Conductor

4.

Wrapping Tape

2.

Polyethylene (Foam Skin)

5.

Aluminium Moisture Barrier

Insulation

6.

Polyethylene Sheath, Black

Identification Tape

7.

Sheath Marking

3.

PRODUCT CODE

PINRAL/PINZAL

TECH. SPEC. NO.

TS - 19000

SAUDI CABLE COMPANY

DUCT

A P P L I C AT I O N

Polyethylene insulated Air Core (unfilled) cables are generally used for primary underground distribution network. The cables are generally
hauled into ducts.

DESCRIPTION

Plain annealed copper solid conductor, high density cellular (foam-skin) polyethylene insulated, paired, unit type, unfilled, screened and
polyethylene sheathed, local air core telephone cable (CES) complying with MOPTT MAT - 1011 specification.

D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

Approx. Outer
Dia. (mm)

Approx.
Gross Wt.
(kgs)

Shipping
Length
(+5/-0m)

Reel Size
(Flange Dia.)
(mm)

101461
100001
100002
100003
100004
100005
100006
100007
100008

200
300
600
900
1,200
1,500
1,800
2,100
2,400

x
x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x
x

0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40

23.5
27.5
37.5
45.0
52.0
57.5
62.5
67.0
72.0

802
1,136
2,216
1,910
1,280
1,610
1,944
2,236
2,564

1,000
1,000
1,000
600
300
300
300
300
300

1,300
1,500
1,900
1,800
1,600
1,800
1,900
2,000
2,100

102659
100009
100010
100011
100012
100013
100014

200
300
600
900
1,200
1,500
1,800

x
x
x
x
x
x
x

2
2
2
2
2
2
2

x
x
x
x
x
x
x

0.50
0.50
0.50
0.50
0.50
0.50
0.50

28.0
33.5
46.0
55.5
63.5
71.0
77.0

1,166
1,750
1,978
1,514
2,032
2,502
2,920

1,000
1,000
600
300
300
300
300

1,500
1,700
1,800
1,700
2,000
2,100
2,200

101794
102720
101316
101317
101318
101319

100
200
300
600
900
1,200

x
x
x
x
x
x

2
2
2
2
2
2

x
x
x
x
x
x

0.65
0.65
0.65
0.65
0.65
0.65

27.5
37.0
44.5
62.0
75.0
85.5

1,022
1,998
1,716
1,750
2,525
3,330

1,000
1,000
600
300
300
300

1,500
1,900
1,800
1,900
2,100
2,400

101294
101795
102721
101295
101296

100
150
200
300
600

x
x
x
x
x

2
2
2
2
2

x
x
x
x
x

0.90
0.90
0.90
0.90
0.90

36.5
44.0
51.5
62.0
85.0

1,146
1,662
2,230
1,688
3,212

600
600
600
300
300

1,600
1,800
2,000
1,900
2,400

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

P A G E

N I N E

UNDERGROUND (DIRECT BURIED)


PRESSURIZED LOCAL TELEPHONE CABLE

1.
2.

3.

Copper Conductor

4.

Wrapping Tape

8.

Outer Poylethylene Sheath, Black

9.

Sheath Marking

Polyethylene (Foam Skin)

5.

Aluminium Moisture Barrier

Insulation

6.

Inner Polyethylene Sheath, Black

Identification Tape

7.

Flooding Compound

PRODUCT CODE

PINRALL/PINZALL

TECH. SPEC. NO.

TS - 19000

SAUDI CABLE COMPANY

A P P L I C AT I O N

Polyethylene insulated Air Core (unfilled) cables are generally used for primary underground distribution network. The cables are for direct
burial applications.

DESCRIPTION

Plain annealed copper solid conductor, high density cellular (foam-skin) polyethylene insulated, paired, unit type, unfilled, screened and
polyethylene (inner & outer) sheathed, local air core telephone cable (CESE) complying with MOPTT MAT-1011 specification.

D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

Approx. Outer
Dia. (mm)

Approx
Gross Wt.
(kgs)

Shipping
Length
(+5/-0m)

Reel Size
(Flange Dia.)
(mm)

100021
100022
100023
100024
100025
100026
100027
100028

300
600
900
1,200
1,500
1,800
2,100
2,400

x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x

0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40

31.0
40.5
48.0
55.5
60.5
66.0
70.5
75.0

1,390
2,444
2,150
1,424
1,762
2,074
2,390
2,672

1,000
1,000
600
300
300
300
300
300

1,700
2,000
2,000
1,700
1,900
2,000
2,100
2,100

100029
100030
100031
100032
100033
100034

300
600
900
1,200
1,500
1,800

x
x
x
x
x
x

2
2
2
2
2
2

x
x
x
x
x
x

0.50
0.50
0.50
0.50
0.50
0.50

37.0
49.5
59.0
67.0
74.5
80.5

1,996
2,220
1,670
2,130
2,610
3,072

1,000
600
300
300
300
300

1,900
2,000
1,900
2,000
2,100
2,300

101320
101321
101322
101323
101324

300
400
600
900
1,200

x
x
x
x
x

2
2
2
2
2

x
x
x
x
x

0.65
0.65
0.65
0.65
0.65

48.0
55.0
65.5
78.5
89.0

1,954
2,516
1,878
2,660
3,460

600
600
300
300
300

2,000
2,100
2,000
2,200
2,400

101297
101298
101299
101300

100
300
400
600

x
x
x
x

2
2
2
2

x
x
x
x

0.90
0.90
0.90
0.90

40.0
65.0
74.5
88.5

1,260
1,816
2,328
3,342

600
300
300
300

1,600
2,000
2,100
2,400

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

S A U D I
P A G E

T E N

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

ELECTRICAL

Conductor Resistance at 20C (Ohms/Km)


Conductor
size (mm)

Maximum DC Resistance
Average
Individual

0.40
0.50
0.65
0.90

144
92
54
28

CHARACTERISTICS

4.2 Pair to Pair Between Adjacent Sub-units or Units


(pF/500 M)
Maximum Average : 17
Maximum Individual : 55
4.3 Pair to Earth (pF/Km)
Maximum Average : 500
Maximum Individual : 2500

150
96
57
30

1.1 Resistance Unbalance


5

Dielectric strength DC Volts (for 3 sec. min.)

Conductor
size (mm)

Maximum Resistance
Unbalance (%)
Average
Individual

Conductor
size (mm)

Between
Conductor

Conductor
to Shield

0.40
0.50
0.65
0.90

1.00
0.75
0.75
0.75

0.40
0.50
0.65
0.90

1,700
2,000
2,500
3,500

5,000
5,000
10,000
10,000

2.5
2.5
2.0
2.0

Attenuation
The maximum average attenuation at
two spot frequencies shall not exceed
the values given below:
Conductor
size (mm)

Maximum Average
Attenuation (dB/Km)
1 KHz
1 MHz

0.40
0.50
0.65
0.90

1.81
1.45
1.10
0.80

26.5
22.6
18.5
13.3

Percent unbalance shall be calculated by


means of the following formula.
Rmax. - Rmin.
R% =

Rmax. + Rmin.

Insulation Resistance at 20C


The I.R. shall be not less than 5,000
mega-ohms km.

The pair-to-pair Near-End (NEXT)


coupling loss of 99% of pair
combinations, shall exceed the values
given below:
Frequency
(KHz)

NEXT
(dB/Km)

1
12
80
1,000

85
80
67
48

Mutual Capacitance at 1,000 200 Hz. (nF/Km)


Nominal Average : 44 2
Maximum Individual : 50

Near End Crosstalk (NEXT) Limits

x100

Capacitance Unbalance at 1,000 200 Hz

4.1 Pair to Pair Within a Sub-unit (pF/500M)


Maximum Average : 25
Maximum Individual : 150

6.1 Near End (NEXT) & Equal Level Far


End (ELFEXT) Limits
The NEXT and ELFEXT individual
power sums shall exceed the
values given below:
Frequency
(KHz)

NEXT
(dB/Km)

ELFEXT
(dB/Km)

1
12
80
1,000

70
67
55
37

74
71
58
36

P A G E

E L E V E N

STUB

1.

Copper Conductor

5.

Aluminium Moisture Barrier

2.

Polyethylene (Solid) Insulation

6.

Polyethylene Sheath, Black

3.

Identification Tape

7.

Sheath Marking

4.

Wrapping Tape

TELEPHONE

CABLE

PRODUCT CODE

PUNRAL

TECH. SPEC. NO.

TS - 20000

SAUDI CABLE COMPANY

STUB

A P P L I C AT I O N

Polyethylene insulated, air core (unfilled), stub telephone cables are generally used between manholes and cabinets or the cable connected
to cabinet or distribution pillar terminal blocks in the telecommunication network.

DESCRIPTION

Plain annealed copper solid conductor, high density solid polyethylene insulated, paired, unit type, unfilled, screened and polyethylene
sheathed, stub telephone cable (EES) complying with MOPTT MAT - 1011 specification.

D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

102925
100044
100045
100046

100
200
300
400

x
x
x
x

2
2
2
2

x
x
x
x

Approx. Outer
Dia. (mm)

Approx.
Gross Wt.
(kgs)

Shipping
Length
(+5/-0m)

Reel Size
(Flange Dia.)
(mm)

24.5
33.0
39.5
45.0

784
1,482
2,142
2,766

1,000
1,000
1,000
1,000

1,400
1,700
2,000
2,200

0.50
0.50
0.50
0.50

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

S A U D I
P A G E

T W E L V E

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

STUB

1.

Copper Conductor

5.

Polyethylene Sheath, Black

2.

Polyethylene (Solid) Insulation

6.

Sheath Marking

3.

Identification Tape

4.

Wrapping Tape

TELEPHONE

CABLE

PRODUCT CODE

PUNRL

TECH. SPEC. NO.

TS - 20000

SAUDI CABLE COMPANY

STUB

A P P L I C AT I O N

Polyethylene insulated, air core (unfilled), stub cable generally used between cabinet or distribution pillar terminal blocks in the
telecommunication network.

DESCRIPTION

Plain annealed copper solid conductor, high density solid polyethylene insulated, paired, unit type, unfilled, unscreened and polyethylene
sheathed, stub telephone cable (EES) complying with MOPTT MAT - 1011 specification.

D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

100041
100717
100042
100043

10
20
50
100

x
x
x
x

2
2
2
2

x
x
x
x

Approx. Outer
Dia. (mm)

Approx.
Gross Wt.
(kgs)

Shipping
Length
(+5/-0m)

Reel Size
(Flange Dia.)
(mm)

10.0
12.0
16.5
23.0

110
185
382
698

1,000
1,000
1,000
1,000

800
900
1,100
1,300

0.50
0.50
0.50
0.50

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

P A G E

T H I R T E E N

ELECTRICAL

Conductor Resistance at 20C (Ohms/Km)

Maximum Average : 92
Maximum Individual : 96

CHARACTERISTICS

Dielectric Strength DC Volts (for 3 sec. Min.)


Between
Conductor

Conductor
to Shield

2,000

5,000

1.1 Resistance Unbalance (%)


Maximum Average : 0.75
Maximum Individual : 2.50
Percent unbalance shall be calculated by
means of the following formula.

The pair-to-pair Near-End (NEXT)


coupling loss of 99% of pair
combinations shall not exceed the
values given below:

Rmax. - Rmin.
R% =

x 100
Rmax. + Rmin.

Insulation Resistance at 20C


The I.R. shall be not less than 10,000
mega-ohms km.

Frequency
(KHz)

NEXT
(dB/Km)

1
12
80
1,000

85
80
67
48

6.1 Near End (NEXT) & Equal Level Far


End (ELFEXT) Limits.
The NEXT & ELFEXT individual power
sums shall exceed the values given
below:

Mutual Capacitance at 1,000 200 Hz (nF/Km)


Nominal Average : 44 2
Maximum Individual : 50

Near End Crosstalk (NEXT) Limits

Capacitance Unbalance at 1,000 200 Hz

4.1 Pair to Pair Within a Sub-unit (pF/500 M)


Maximum Average : 22
Maximum Individual : 150
4.2 Pair to Pair Between Adjacent
Sub-units or Units (pF/500 M)
Maximum Average : 20
Maximum Individual : 50

Frequency
(KHz)

NEXT
(dB/Km)

ELFEXT
(dB/Km)

1
12
80
1,000

70
67
55
37

74
71
58
36

Attenuation
The maximum average attenuation at
two spot frequencies shall not exceed
the values given below:

4.3 Pair to Earth (pF/Km)


Maximum Average : 500
Maximum Individual : 2,500

Maximum Average Attenuation (dB/Km)


1KHz
1.45

S A U D I
P A G E

F O U R T E E N

C A B L E

C O M P A N Y

1MHz
22.6

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

NOTES

P A G E

F I F T E E N

FLAME

RETARDANT

INDOOR

1.

Copper Conductor

5.

Sheath Rip Cord

2.

PVC Insulation

6.

Halogen-Free Low Smoke

3.

Identification Tape

4.

Wrapping Tape

TELEPHONE

CABLE
PRODUCT CODE

POMRF

TECH. SPEC. NO.

TS - 21000

Sheath, Light Grey

SAUDI CABLE COMPANY

A P P L I C AT I O N

Polyvinyl chloride (PVC) insulated Air core (unfilled), cables are generally used for indoor installation in the telecommunication network.

DESCRIPTION

Plain annealed copper solid conductor, PVC insulated, paired, unit type, unfilled and halogen free flame retardant sheathed indoor
telephone cable (VRB) complying with MOPTT MAT - 1401 specification.

D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

100117
100118
100119
100120
100121
100122
100123
100124

10
20
30
50
100
150
200
300

x
x
x
x
x
x
x
x

2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x

Approx. Outer
Dia. (mm)

Approx
Gross Wt.
(kgs)

Shipping
Length
(+5/-0m)

Reel Size
(Flange Dia.)
(mm)

8.5
11.0
13.0
16.5
22.0
27.0
30.5
37.0

116
186
275
438
790
1,140
1,502
2,262

1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000

800
800
900
1,100
1,300
1,500
1,600
1,900

0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

S A U D I
P A G E

S I X T E E N

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

ELECTRICAL

CHARACTERISTICS

Conductor Resistance at 20C (Ohms/Km)


Maximum Average : 92
Maximum Individual : 96

1.1 Resistance Unbalance (%)


Maximum Average : 0.75
Maximum Individual : 2.50
Percent unbalance shall be calculated by
means of the following formula.
Rmax. - Rmin.
R% =

x 100
Rmax. + Rmin.

Insulation Resistance at 20C


The I.R. shall be not less than 500
mega-ohms km.

Mutual Capacitance at 1,000 200 Hz (nF/Km)


Nominal Average : 75 2
Maximum Individual : 90

Capacitance Unbalance at 1,000 200 Hz

4.1 Pair to Pair Within a Sub-unit (pF/500 M)


Maximum Average : 22
Maximum Individual : 150
4.2 Pair to Pair Between Adjacent Sub-units or Units
(pF/500 M)
Maximum Average : 20
Maximum Individual : 50

Dielectric Strength DC Volts (for 60 sec. Min.)


Conductor to Conductor : 1,500

P A G E

S E V E N T E E N

SELF

SUPPORTING

1.

Copper Conductor

5.

Aluminium Moisture Barrier

2.

Polyethylene (Solid) Insulation

6.

3.

Identification Tape

Stranded Support Messenger


(Galvanised Steel Wires)

4.

Wrapping Tape

7.

Polyethylene Sheath, Black

AERIAL

8.

CABLE

Sheath Marking

PRODUCT CODE

PUNRAOL/PUNZAOL

TECH. SPEC. NO.

TS - 24000

SAUDI CABLE CO

A P P L I C AT I O N

Polyethylene insulated Air Core (unfilled) aerial telephone cables are generally used in the local telecommunication network on poles and walls.

DESCRIPTION

Plain annealed copper solid conductor, high density solid polyethylene insulated, paired, unit type, unfilled, screened, galvanized steel wires
core messenger and polyethylene sheathed self-supported aerial telephone cable (EEMS) complying with MOPTT MAT-1201 specification.

D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

Approx. Nom. Dia.


(mm) D1 x D2 x H

No. & Dia. of


Steel Wire
(mm)

Approx. Gross
Wt. (kgs)

Shipping
Length
(+5/-0m)

Reel Size
(Flange Dia.)
(mm)

100615
100616
100617
100618

50
100
150
200

x
x
x
x

2
2
2
2

x
x
x
x

0.40
0.40
0.40
0.40

15.5
20.0
24.5
27.5

x
x
x
x

6.6
6.6
7.2
8.4

x
x
x
x

25.0
30.0
34.5
39.0

7
7
7
7

x
x
x
x

1.2
1.2
1.2
1.6

432
660
927
1,238

1,000
1,000
1,000
1,000

1,200
1,500
1,600
1,800

100619
100620
100621
100622

50
100
150
200

x
x
x
x

2
2
2
2

x
x
x
x

0.50
0.50
0.50
0.50

18.5
24.5
29.0
33.0

x
x
x
x

6.6
8.4
8.4
8.6

x
x
x
x

28.0
36.0
40.5
44.5

7
7
7
7

x
x
x
x

1.2
1.6
1.6
1.6

549
994
1,426
1,750

1,000
1,000
1,000
1,000

1,300
1,600
1,900
2,000

102007
102008
102009
102016
102010
102011

10
20
50
100
150
200

x
x
x
x
x
x

2
2
2
2
2
2

x
x
x
x
x
x

0.65
0.65
0.65
0.65
0.65
0.65

13.0
16.5
24.2
32.5
39.5
44.5

x
x
x
x
x
x

6.6
6.6
7.2
8.4
8.6
8.8

x
x
x
x
x
x

23.0
26.0
34.5
44.0
50.5
56.5

7
7
7
7
7
7

x
x
x
x
x
x

1.2
1.2
1.2
1.6
1.6
1.6

331
460
862
1,584
2,191
2,751

1,000
1,000
1,000
1,000
1,000
1,000

1,100
1,300
1,600
2,000
2,300
2,400

102012
102017
102013
102014
102015

10
20
50
100
150

x
x
x
x
x

2
2
2
2
2

x
x
x
x
x

0.90
0.90
0.90
0.90
0.90

16.5 x 6.6
21.5 x 6.6
32.0 x 8.4
43.0 x 8.8
53.0 x 10.6

x
x
x
x
x

26.0
31.0
43.5
55.0
67.0

7
7
7
7
7

x
x
x
x
x

1.2
1.2
1.6
1.6
2.0

450
674
1,541
2,640
2,426

1,000
1,000
1,000
1,000
600

1,300
1,500
2,000
2,400
2,400

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

S A U D I
P A G E

E I G H T E E N

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

ELECTRICAL

Conductor Resistance at 20C (Ohms/Km)


Conductor
size (mm)

Maximum DC Resistance
Average
Individual

0.40
0.50
0.65
0.90

144
92
54
28

150
96
57
30

CHARACTERISTICS

4.2 Pair to Pair Between Adjacent Sub-units or Units


(pF/500 M)
Maximum Average : 20
Maximum Individual : 50
4.3 Pair to Earth (pF/Km)
Maximum Average : 500
Maximum Individual : 2500

1.1 Resistance Unbalance


5

Dielectric strength DC Volts (for 3 sec. Min.)

Conductor
size (mm)

Maximum Resistance
Unbalance (%)
Average
Individual

Conductor
size (mm)

Between
Conductor

Conductor
to Shield

0.40
0.50
0.65
0.90

1.00
0.75
0.75
0.75

0.40
0.50
0.65
0.90

1,700
2,000
2,500
3,500

5,000
5,000
10,000
10,000

2.5
2.5
2.0
2.0

Attenuation
The maximum average attenuation at
two spot frequencies shall not exceed
the values given below:
Conductor
size (mm)

Maximum Average
Attenuation (dB/Km)
1 KHz
1 MHz

0.40
0.50
0.65
0.90

1.89
1.51
1.16
0.84

28.6
24.2
19.8
14.3

Percent unbalance shall be calculated by


means of the following formula.
Rmax. - Rmin.
R% =

Rmax. + Rmin.

Insulation Resistance at 20C


The I.R. shall be not less than 10,000
mega-ohms km.

The pair-to-pair Near-End (NEXT)


coupling loss of 99% of pair
combinations shall exceed the values
given below:
Frequency
(KHz)

NEXT
(dB/Km)

1
12
80
1,000

85
80
67
48

Mutual Capacitance at 1,000 200 Hz. (nF/Km).


Nominal Average : 44 2
Maximum Individual : 50

Near End Crosstalk (NEXT) Limits.

x100

Capacitance Unbalance at 1,000 200 Hz.

4.1 Pair to Pair Within a Sub-unit (pF/500M).


Maximum Average : 22
Maximum Individual : 150

6.1 Near End (NEXT) & Equal Level Far


End (ELFEXT) Limits.
The NEXT and ELFEXT individual
power sums shall exceed the
values given below:
Frequency
(KHz)

NEXT
(dB/Km)

ELFEXT
(dB/Km)

1
12
80
1,000

70
67
55
37

74
71
58
36

P A G E

N I N E T E E N

BURIED

1.

Copper Conductor

4.

Aluminium Moisture Barrier

2.

Polyethylene (Solid) Insulation

5.

Outer Polyethylene Sheath, Black

3.

Inner PVC Sheath

SERVICE

WIRE

PRODUCT CODE

P U N Q VA L

TECH. SPEC. NO.

TS - 22000

A P P L I C AT I O N

Polyethylene insulated air-core (unfilled) two pairs service wire used for direct buried installation in the outside plant network between
external distribution points and subscriber's external wire (customer terminals).

DESCRIPTION

Plain annealed copper solid conductor, high density solid polyethylene insulated, unfilled, 2 pair (single quad), PVC inner sheathed,
screened and LDPE outer sheathed buried service telephone wire (BSW) complying with MOPTT MAT-1301 specification.

D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

Approx. Outer
Dia. (mm)

Approx.
Gross Wt.
(kgs)

Shipping
Length
(+5/-0m)

Reel Size
(Flange Dia.)
(mm)

100636

1 x 4 x 0.50

8.60

201

2,000

900

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

S A U D I
P A G E

T W E N T Y

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

ELECTRICAL

Conductor Resistance at 20C (Ohms/Km)

CHARACTERISTICS

Attenuation
The maximum average attenuation at
two spot frequencies shall not exceed
the values given below:

Maximum Average : 92
Maximum Individual : 96

Maximum Average Attenuation (dB/Km)


1.1 Resistance Unbalance (%)
Maximum Average : 0.75
Maximum Individual : 2.50

1 KHz
1.45

1 MHz
22.6

Percent unbalance shall be calculated by


means of the following formula.
Rmax. - Rmin.
R% =

x 100
Rmax. + Rmin.

Insulation Resistance at 20C


The I.R. shall be not less than 10,000
mega-ohms km.

Mutual Capacitance at 1,000 200 Hz (nF/Km)


Nominal Average : 44 2
Maximum Individual : 50

Capacitance Unbalance at 1,000 200 Hz

4.1 Pair to Pair (pF/500 M)


Maximum Individual : 300
4.2 Pair to Earth (pF/Km)
Maximum Average : 500
Maximum Individual : 2,500

Dielectric Strength DC Volts (for 3 sec. Min.)


Conductor to Conductor : 3,000
Conductor to Screen : 10,000

P A G E

T W E N T Y

O N E

DROP

1.

WIRE

Hard Drawn Copper Clad

PRODUCT CODE

CUBO

TECH. SPEC. NO.

TS - 23000

Steel Conductor
2.

Polyethylene Insulation, Black

A P P L I C AT I O N

Telephone drop wire is used for outdoors connection between distribution box and the subscriber's premises in the
telecommunications network.

DESCRIPTION

Two parallel laid (hard drawn copper clad steel) conductors, high density solid polyethylene insulated telephone drop wire complying with
MOPTT MAT-1311, specification.

D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

No. of Cond. x
Size (No. x mm)

Approx. Outer
Dia. (mm)

Approx.
Gross Wt.
(kgs/coil)

Shipping
Length
(5% m)

Approx.
Coil Size
OD/ID/Width
(mm)

100635

2 x 0.80

6.0 x 3.0

250

320 x 150 x 90

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

S A U D I
P A G E

T W E N T Y

T W O

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

ELECTRICAL

CHARACTERISTICS

Conductor Resistance at 20C (Ohms/Km)


Maximum Average : 88
Maximum Individual : 92

1.1 Resistance Unbalance (%)


Maximum Average : 1.0
Maximum Individual : 3.6
Percent unbalance shall be calculated by
means of the following formula.
Rmax. - Rmin.
R% =

x 100
Rmax. + Rmin.

Insulation Resistance at 20C


The I.R. shall be not less than 500
mega-ohms km.

Insulation Integrity between each


Cond. to Water
To withstand 15Kv for five (5) minutes

Mutual Capacitance at 1,000 200 Hz (nF/Km)


Maximum Average : 40

Dielectric Strength DC Volts (for 60 sec. Min.)


Conductor to Conductor : 1,500

P A G E

T W E N T Y

T H R E E

JUMPER

1.

Copper Conductor

2.

PVC Insulation

3.

Nylon Sheath, Transparent

WIRE

PRODUCT CODE

POXON

TECH. SPEC. NO.

TS - 25000

A P P L I C AT I O N

The polyvinyl chloride (PVC) insulated and nylon sheathed jumper wire is generally used in main distribution frame (MDF) in
exchange buildings.

DESCRIPTION

Plain annealed copper solid conductor, polyvinyl chloride (PVC) insulated, nylon sheathed, twisted into single pair jumper telephone wire
(type CO-AX2) complying with MOPTT MAT 1501 specification.

D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

Approx. Outer
Dia. (mm)

Approx.
Gross Wt.
(kgs/coil)

Shipping
Length
(5% m)

Approx.
Coil Size
ODxIDxWidth
(mm)

100943

1 x 2 x 0.60

2.24

3.60

500

225 x 120 x 85

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

S A U D I
P A G E

T W E N T Y

F O U R

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

ELECTRICAL

CHARACTERISTICS

Conductor Resistance at 20C (Ohms/Km)


Maximum d.c. resistance : 63

Insulation Resistance at 20C


The I.R. shall be not less than 5,000
mega-ohms km.

Dielectric Strength DC Volts (for 60 sec. Min.)


Conductor to Conductor : 1,500

P A G E

T W E N T Y

F I V E

JUMPER

1.

Copper Conductor

2.

Polyethylene (solid) insulation

WIRE

PRODUCT CODE

PUXO

TECH. SPEC. NO.

TS-30000

A P P L I C AT I O N

The polyethylene insulated jumper wire is generally used in cross connection cabinets between the primary and secondary terminal blocks.

DESCRIPTION

Plain annealed copper solid conductor, high density solid polyethylene insulated, twisted into single pair telephone (OP-CAB) jumper wire
complying with MOPTT MAT 1501 specification.

D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

Approx. Outer
Dia. (mm)

Approx.
Gross Wt.
(kgs/coil)

Shipping
Length
(5% m)

Coil Size
ODxIDxWidth
(mm)

100637

1 x 2 x 0.50

2.20

1.30

250

178 x 120 x 85

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

S A U D I
P A G E

T W E N T Y

S I X

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

ELECTRICAL

CHARACTERISTICS

Conductor Resistance at 20C (Ohms/km)


Maximum Average : 92
Maximum Individual : 96

1.1 Resistance Unbalance (%)


Maximum Average : 0.75
Maximum Individual : 2.5
Percent unbalance shall be calculated by
means of the following formula.
Rmax. - Rmin.
R% =

x 100
Rmax. + Rmin.

Insulation Resistance at 20C


The I.R. shall be not less than 10,000
mega-ohms km.

Dielectric Strength DC Volts (for 60 Sec. Min.)


Conductor to Conductor : 1,500

P A G E

T W E N T Y

S E V E N

INDOOR

1.

Copper Conductor

2.

PVC Insulation, Light Grey

WIRE

(TYPE-A)

PRODUCT CODE

POXO

TECH.SPEC.NO.

TS-28000

A P P L I C AT I O N

Telephone indoor wire (type-A) is generally used between internal distribution points or subscriber termination blocks to wall mounted
telephone sockets in the telecommunication network.
DESCRIPTION

Two parallel laid (plain annealed copper solid) conductors, flame retardant polyvinyl chloride (PVC) insulated indoor telephone wire (type-A)
complying with MOPTT MAT-1411 Specification.
D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

Approx. Outer
Dia. (mm)

100944

2 x 0.65

3.0 x 1.3

Approx.
Gross Wt.
(kgs/coil)

2.4

Shipping
Length
(5% m)

Coil Size
ODxIDxWidth
(mm)

250

200 x 150 x 90

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

S A U D I
P A G E

T W E N T Y

E I G H T

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

INDOOR

Copper Conductor

PVC Insulation

PVC Sheath, Light Grey

WIRE

(TYPE-B)

PRODUCT CODE

POMQV

TECH.SPEC.NO.

TS-29000

A P P L I C AT I O N

Telephone indoor wire (type-B) is generally used between internal distribution points or subscriber termination blocks to wall mounted
telephone sockets in the telecommunication network.
DESCRIPTION

Plain annealed copper solid conductor, high density polyvinyl chloride (PVC) insulated, 2 pair (single quad), unfilled, flame retardant PVC
sheathed indoor telephone wire (type-B) complying with MOPTT MAT - 1411 specification.
D I M E N S I O N A L D ATA & PA C K I N G

SCC-T
Product
No.

Pair Count x
Size (No. x mm)

Approx. Outer
Dia. (mm)

Approx.
Gross Wt.
(kgs/coil)

Shipping
Length
(5% m)

Coil Size
ODxIDxWidth
(mm)

100942

1 x 4 x 0.65

6.20

12.5

250

375 x 150 x 90

Other sizes and specifications are available upon request.


*The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

P A G E

T W E N T Y

N I N E

ELECTRICAL

CHARACTERISTICS

Conductor Resistance at 20C (Ohms/Km)


Maximum Average : 54
Maximum Individual : 57

1.1 Resistance Unbalance (%)


Maximum Average : 1.3
Maximum Individual : 3.6
Percent unbalance shall be calculated by
means of the following formula.
Rmax. - Rmin.
R% =

x 100
Rmax. + Rmin.

Insulation Resistance at 20C


The I.R. shall be not less than 500
mega-ohms km.

Mutual Capacitance at 1,000 200 Hz (nF/Km)


Nominal Average:
Type-A : 100 5
Type-B : 75 5

Dielectric Strength DC Volts (for 3 sec. Min.)


Conductor to Conductor : 1,500

S A U D I
P A G E

T H I R T Y

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

NOTES

P A G E

T H I R T Y

O N E

NOTES

S A U D I
P A G E

T H I R T Y

T W O

C A B L E

C O M P A N Y

T E L E C A B L E

D I V I S I O N

M E T A L L I C

C A B L E

You might also like