4100
page 1 of 3
Half Facepiece Respirator
6000 Series, Reusable
Issue Date 7/1/09
Unmatched performance
and comfort.
3M Half Facepiece Respirator
6000 Series, Reusable offers the
user comfort and convenience
coupled with the cost savings of
a reusable respirator.
Features/Benefits
Used with 3M Filters and
Cartridges, these respirators are
among the lightest available
The swept back design of the
cartridges helps improve balance
and visibility
Remarkably comfortable,
soft, lightweight facepiece
and easy-to-adjust head straps
Reusable just dispose of
the cartridges/filters when
used to capacity
Can be disassembled, cleaned
and reused
NIOSH approved for negative
pressure air purifying and
supplied air dual airline
applications
Supplied with reclosable
storage bag
The half facepieces are available
in 3 sizes (small, medium, large)
to comfortably fit many faces
The 6000 Series respirators can
be used in dual airline mode:
Available with both backmounted and front-mounted
breathing tubes
The 3M Half Facepiece Respirator 6000 Series, Reusable with
replaceable cartridges/filters
S
ystems can be used in
combination with NIOSH
approved 3M 2000 or
2200 Series Filters or 6000
Series Cartridges and P100
Filter/Cartridges
Cartridge/filter connections
provide negative pressure and
supplied air capability in one
respirator assembly
Wearer can disconnect the
airline at the air regulating valve
and the system is changed to a
filters/ cartridges air purifying
mode then back to supplied
air system with a simple
reconnection of the airline
Small diameter breathing tubes
are simple to work with and easy
to clean and decontaminate
Can be used on both high
and low pressure supplied
air systems*
WARNING
These respirators help protect against certain airborne contaminants. Misuse may result
in sickness or death. Before use, the wearer must read and understand User Instructions
provided as a part of product packaging. Time use limitations may apply. For proper use,
see package instructions, supervisor or call 3M OH&ESD Technical Service in U.S.A.,
1-800-243-4630. In Canada, call 1-800-267-4414.
Important
Before using these respirators, you must determine the following:
1. The type of contaminant(s) for which the respirator is being selected.
2. The concentration level of contaminant(s).
3. Whether the respirator can be properly fitted on the wearers face. All respirator instructions, warnings and use
and time limitations must also be read and understood by the wearer before use.
Before use of these respirators, a written respiratory protection program must be implemented, meeting all the
requirements of OSHA 29 CFR 1910.134, including training, medical evaluation and fit testing.
* Employer must provide a minimum of Grade D breathing air in accordance with OSHA requirements
3M Half Facepiece Respirator
6000 Series, Reusable
4100
page 2 of 3
3M Filters and Accessories 2000 and 2200 Series, 7093, 5N11, 5P71
2071
2076HF
P95 Filter
P95 Filter with hydrogen
fluoride, nuisance level
acid gas relief*
2291
P100 Filter
2078
2091/07000
P95 Filter with nuisance
level organic vapor and
acid gas relief*
2296
P100 Filter with nuisance
level acid gas relief*
P100 Filter
2297
P100 Filter with nuisance
level organic vapor relief*
2096
2097/07184
P100 Filter with
nuisance level acid
gas relief*
7093
P100 Filter
P100 Filter with
nuisance level organic
vapor relief*
7093C/37173
P100 Cartridge/Filter
with hydrogen fluoride,
nuisance level organic vapor
and acid gas relief*
*Nuisance levels refer to concentrations below the OSHA PEL or other government standard, whichever is lower.
603
Filter Adapter (Use with the
5N11 or 5P71 Filters and
501 Filter Retainer)
5N11
N95 Filter (Use with the
501 Filter Retainer and
6000 Series cartridges)
5P71/07194
P95 Filter (Use with the
501 Filter Retainer and
6000 Series cartridges)
501
502
Filter Retainer (Use with
Filter Adapter (Use with 2000
5N11 and 5P71 Filters and and 2200 Series and 7093 Filters
6000 Series cartridges)
and 6000 Series cartridges)
3M Cartridges 6000 Series
Product
Number
NIOSH Approval*
Product
Number
NIOSH Approval*
6001
Certain organic vapors (a)(b)
60921
P100/Certain organic vapors (a)(b)
6002
60922
6004
Chlorine, hydrogen chloride, and sulfur dioxide
or chlorine dioxide or hydrogen sulfide (a)(b)
Certain organic vapors, chlorine, hydrogen chloride,
and sulfur dioxide or hydrogen sulfide or hydrogen
fluoride (a)(b)
Ammonia and methylamine (a)(b)
60924
P100/Chlorine, hydrogen chloride, and sulfur dioxide or
chlorine dioxide or hydrogen sulfide (a)(b)
P100/Certain organic vapors, chlorine, hydrogen
chloride, and sulfur dioxide or hydrogen sulfide or
hydrogen fluoride (a)(b)
P100/Ammonia and methylamine (a)(b)
6005
Formaldehyde and certain organic vapors (a)(b)
60925
P100/Formaldehyde and certain organic vapors (a)(b)
6006
Certain organic vapors, chlorine, hydrogen chloride,
chlorine dioxide, sulfur dioxide, hydrogen sulfide
ammonia/methylamine, formaldehyde or hydrogen
fluoride (a)(b)(c)
60926
6009
Mercury vapor or chlorine gas (a)(b)
P100/Certain organic vapors, chlorine, hydrogen
chloride, chlorine dioxide, sulfur dioxide, hydrogen
sulfide ammonia/methylamine, formaldehyde or
hydrogen fluoride (a)(b)(c)
P100/Organic vapor/Acid gas (d)
P100/Mercury vapor or chlorine gas (a)(b)
6003
60923
60928
60929
* For respiratory protection against the following contaminants up to 10X PEL with half facepiece respirators and full facepiece respirators when qualitatively fit
tested, or 50X PEL with full facepiece respirators when quantitatively fit tested.
(a) All respirators and respirator/filter assemblies can be used up to the NIOSH approval limits, 10X PEL for half facepiece respirators and full facepiece respirators
when qualitatively fit tested, or 50X PEL for full facepiece respirators when quantitatively fit tested or the maximum use concentration allowable in applicable OSHA
standards, whichever is lower.
(b) For specific usage, limitations and warning information, see respirator and/or filter packaging, or call 3M OH&ESD Technical Service 1-800-243-4630.
In Canada call 1-800-267-4414.
(c) OSHA regulations require that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde.
(d) As recommended by the California Department of Pesticide Regulation No. 01-099 Methyl Bromide Field Fumigation.
4100
3M Half Facepiece Respirator
6000 Series, Reusable
page 3 of 3
To complete a 3M Dual Airline Respirator System, select a facepiece, an adapter kit and an air supply hose.
For example: 6200 + SA-2000 + W-9435-100 = complete system.
Accessories and Replacement Parts
High Pressure
Low Pressure
Standard Back-Mounted Adapter Kit. Includes SA-2500 Breathing Tube, GVP-127 Belt and
SA-1009 Air Regulator or SA-1029 Connector (low pressure).
SA-2000
SA-2000LP
Combination Back-Mounted Adapter Kit. Includes 2600 Breathing Tube, GVP-127 Belt and
SA-1009 Regulator or SA-1029 Connector (low pressure). Cartridges/Filters not included.
SA-2100
SA-2100LP
Standard Front-Mounted Adapter Kit. Includes SA-1500 Breathing Tube, GVP-127 Belt, and
SA-1009 Regulator or SA-1029 Connector (low pressure).
SA-1000
SA-1000LP
Combination Front-Mounted Adapter Kit. Includes SA-1600 Breathing Tube, GVP-127 Belt, and
SA-1009 Regulator or SA-1029 Connector (low pressure). Cartridges/Filters not included.
SA-1100
SA-1100LP
Half Facepiece Replacement Parts 6000 Series
Half Facepiece 6000 Series
6281
Respirator Strap Assembly
6893
Inhalation Valve
6889
Exhalation Valve
6895
Inhalation Gasket
Facepieces
per bag
Facepieces
per case
24
Half Facepieces
6100/07024
(Small)
6200/07025
(Medium)
6300/07026
(Large)
3M Half Facepiece Respirator
Quantitative
3M
Fit Test
07024
Small
07025 Medium
Adapter
601
07026 Large
37001
For use with all 3M bayonet
attachment facepieces.
SA-2600
07149
07150
3M Full Facepiece Respirator
Fit Test Respirator
3M
07138
Small
07139
3MMedium
developed this product
07140 Large
specifically for quantitative fit
testing. Available in small (6100Q),
medium (6200Q) and large (6300Q).
A probe has been added for fit
testing purposes. Do not use for
respiratory protection.
3M Fit Test Kits
FT-10 Qualitative Fit Test
Apparatus (sweet solution)
FT-20 Training and Fit Testing
Case (sweet solution)
FT-30 Qualitative Fit Test
Apparatus (bitter solution)
07152
Occupational Health and Environmental Safety Division
3M Center, Building 235-2E-91
St. Paul, MN 55144-1000
For more information, please contact:
3M Occupational Health and
Environmental Safety Division
(OH&ESD)
In the U.S., contact:
Customer Service
1-800-328-1667
Technical Assistance
1-800-243-4630
Website
www.3M.com/OccSafety
For other 3M products
1-800-3M HELPS
In Canada, contact:
3M Canada Company, OH&ESD
P.O. Box 5757
London, Ontario N6A 4T1
Customer Care
1-800-364-3577
Technical Assistance (Canada only)
1-800-267-4414
Website
www.3M.ca/safety
Technical Assistance In Mexico
01-800-712-0646
5270-2255, 5270-2119 (Mexico City only)
Technical Assistance In Brazil
0800-132333