NEC EXPRESS5800/R320d-M4 Configuration Guide: Windows Server 2008 R2 Model
NEC EXPRESS5800/R320d-M4 Configuration Guide: Windows Server 2008 R2 Model
Configuration Guide
Windows Server
2008 R2 model
Introduction
This document contains product and configuration information that will enable you to configure your system. The
guide will ensure fast and proper configuration of your NEC EXPRESS5800 server.
March 2014
Revision 1.0
NEC Corporation
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Key Features .......................................................................................................................................... 3
Specification .......................................................................................................................................... 3
7
8
REFERENCES............................................................................................................... 17
Server Management ............................................................................................................................ 17
Supported PCI Cards and Installable Slots ...................................................................................... 18
Notes for using Hyper-V ..................................................................................................................... 19
Copyright Notice and Liability Disclaimer ........................................................................................ 20
NEC Corporation
Technical Specification
Key Features
TM
Specification
Model
R320d-M4
Part Number
Processor
N8800-185F
Type
Clock speed
2.50 GHz
Logical Number of
Processors
Cache
1 or 2
10C / 20T
TM
Chipset
Memory
Internal Storage
Expansion Slots
[free]
Video
25 MB
Intel C602 Chipset with GeminiEngine
Type
Memory Clock
1600MHz
Logical Standard
Capacity
Logical Maximum
Capacity
Memory protection
0GB
Standard Capacity
0GB
Maximum Logical
Capacity
Disk Controller
9.6 TB (8 x 1.2TB)
RAID
Hot Plug
Supported
1 [0]
Controller (VRAM)
Resolution / Color
Supported
8 [8]
Total: 4 slots available
2 Low-profile PCIe x4 Gen 2 (x8 connector)
2 Full-height PCIe x8 Gen 2 (x8 connector)
Interfaces
Server Management
EXPRESSSCOPE Engine 3
Power Supply
NEC Corporation
R320d-M4
1,300 VA / 1,290 Watt
483.0 x 736.0 x 178 mm / 19.0 x 29.0 x 7.0 in (4U)
Operating: 10 to 35 C / 50 to 95 F, 20 to 80%
Non-Operating: -10 to 55 C / 14 to 131 F, 20 to 80%
Operating Systems
NEC Corporation
External Views
Front and Rear Views
Front View
B
C D
E
F
H
I
J
B
K
Legend
A.
Drive Bays
L.
B.
UID Button
M.
C.
N.
D.
O.
E.
P.
PRIMARY LED
F.
System FT LED
Q.
G.
UID LED
R.
H.
USB Connector
S.
I.
Pull-out Tab
T.
J.
Power Button
U.
K.
Module ID LED
NEC Corporation
Rear View
B
Legend
A.
USB Connectors
F.
AC Inlet
B.
G.
C.
Module ID LED
H.
D.
I.
E.
J.
VGA Connector
NEC Corporation
Dimensions (mm)
Rack mount
748.5
736
177
448
485
688.5
804
592
327
NEC Corporation
Configuration Diagram
Server
CHASSIS
REAR
CHASSIS
FRONT
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
Backplane
CPU/IO Module
HDD Bay
CPU/IO Module
DIMM #8
DIMM #7
DIMM #6
DIMM #5
DIMM #9
DIMM #10
DIMM #11
DIMM #12
HDD Bay
HDD Bay
PCI Riser
Cooling Fan #1 - #4
Processor
CHASSIS
FRONT
HDD Bay
#1
#2
#3
#4
Drive Cage
HDD Bay
DIMM
DIMM
DIMM
DIMM
HDD Bay
CHASSIS
REAR
HDD Bay
CPU/IO module #0 :
Power Supply
#16
#15
#14
#13
DIMM
DIMM
DIMM
DIMM
#1
#2
#3
#4
HDD Bay
DIMM
DIMM
DIMM
DIMM
HDD Bay
Processor
PCIe 2.0 x4 (x8 socket) LP
PCIe 2.0 x4 (x8 socket) LP
HDD Bay
HDD Bay
HDD Bay
HDD Bay
HDD Bay
Drive Cage
HDD Bay
DIMM #8
DIMM #7
DIMM #6
DIMM #5
DIMM #9
DIMM #10
DIMM #11
DIMM #12
HDD Bay
PCI Riser
Cooling Fan #1 - #4
Processor
HDD Bay
CPU/IO module #1 :
Processor
PCIe 2.0 x4 (x8 socket) LP
PCIe 2.0 x4 (x8 socket) LP
Power Supply
Legend:
NEC Corporation
DIMM
DIMM
DIMM
DIMM
#16
#15
#14
#13
Standard components
Server Configuration
1 Base Models
Product Name / Description
Part Number
EXPRESS5800/R320d-M4
no RAM, no 2.5-inch HDD
Including:
Intel Xeon Processor E5-2670 v2, 1 x DVD Super Multi, EXPRESSBUILDER DVD
N8800-185F
2 2nd Processor
Available logical sockets: 1
Product Name / Description
Part Number
Intel Xeon Processor E5-2670 v2 2nd Processor Kit : 2.50 GHz / 10C-20T / 25 MB, 2
processors included
N8801-047
3 Memory
Available logical slots: 8 per processor
Product Name / Description
Part Number
N8802-060
N8802-061
N8802-062
NOTE:
NEC Corporation
Number of Logical
Processors
4GB
4GB
32GB
64GB
8GB
12GB
16GB
20GB
24GB
28GB
32GB
48GB
64GB
64GB
96GB
128GB
4GB
8GB
12GB
16GB
24GB
32GB
40GB
10
48GB
12
56GB
14
64GB
16
96GB
128GB
192GB
256GB
NEC Corporation
10
Part Number
N8850-047
N8850-048
N8850-051
N8850-049
N8850-050
NOTE:
Up to 28GB
32GB to 64GB
96GB to 192GB
256GB
146.5GB
300GB
600GB
900GB
5 Optical Drive
Available bays: 1
Product Name / Description
Part Number
Internal DVD Super Multi Drive : 1 x DVD Super Multi drive, not including writing software
(Standard)
6 PCI Card
6.1 LAN Controller
Category
Part Number
LAN Controller
N8804-009
N8804-011
NOTE:
For iSCSI (data) connection, only 1000BASE-T ports (Including standard LAN ports) are supported.
NEC Corporation
11
Part Number
Fibre Channel
Controller
N8803-038
SAS Controller
N8803-039
NOTE:
For supported NEC Storage products to connect with N8803-038, contact your sales representative or
refer to the NEC Storage WEB site. (http://www.nec.com/global/prod/storage/)
Part Number
Keyboard
USB Keyboard
N8870-002AF
Mouse
N8870-012
Cable
K410-177(1A)
NEC Corporation
12
8 Add-on Components
8.1 17-inch LCD Console Drawer
Category
Drawer
w/ KVM
Switch
Part Number
Drawer
N8143-77F
Cable
K410-118(1A)
Drawer
Drawer
w/o KVM
Switch
Keypad
K410-118(03)
K410-118(05)
N8143-76F
N8143-84F
N8143-85
N8143-87
Part Number
KVM Switch
N8191-12F
K410-118(1A)
Cable
KVM
Cascading
K410-118(03)
K410-118(05)
K410-119(1A)
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-86
NEC Corporation
13
Part Number
UL0999-436EN
Chinese Traditional
UL0999-436CT
Chinese Simplified
UL0999-436CS
Korean
UL0999-436KR
NOTE:
Service Pack1 is not included in these products. Service Pack1 needs to be applied separately.
Part Number
UL1535-001E
Part Number
N8843-004
NEC Corporation
LTO3
SAS
Refer to 8.7.2
LTO4
SAS
Refer to8.7.2
LTO5
SAS
Refer to 8.7.2
LTO6
SAS
Refer to 8.7.2
14
Part Number
Controller
Required
N8803-039
External Cable
Required
SAS Controller
LSI SAS9212-4i4e Host Bus Adapter
6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8,
LP/FH
NOTE: Up to one controller per module
External SAS cable
2 m, for Tape Drive Enclosure connection
Tape Enclosure
Required
N8141-59F
Power Module
Recommended
Power Supply
1 x non-hot plug power supply unit for redundant configuration
N8181-54F
Internal Cable
K410-249(00)
Drive
2 bays available
N8151-102
K410-191(02)
N8151-90
N8151-103
N8151-106
When configuring two sets of a SAS controller, a SAS cable and a backup device, two backup devices
are recognized separately by the OS. When scheduling an automatic backup job, make a job for each
backup device so that the other backup device can backup in case one device fails.
With BrightStor ARCserve Backup, backup is not executed if you enter an asterisk (*) in the group box
under the destination tab when defining a job. Be sure to create two backup jobs by correctly selecting
the device group for the group box, and entering an asterisk (*) or the name of the media in the media
box.
NEC Corporation
15
Backup software
Part Number
ARCserve
Backup Exec
ARCserve r16.5
WS2008R2
WS2008R2
N8151-102
*a1
*b1
N8151-90
*a1
*b1
N8151-103
*a1
*b1
N8151-106
*a1
*b1
NEC Corporation
16
References
Server Management
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system
management features listed in the table below.
Temperature/voltage/power/
fan /degeneration (memory/hard drive)
Boot monitoring
Alerting
Remote KVM
(via LAN)
Remote control
(via LAN)
OS shutdown
Remote batch
Others
Remote wakeup
Centralized
management
Industry standard
IPMI
2.0
Hardware
monitoring
NEC Corporation
17
Slots
Notes
Slot # :
#1
#2
#3
#4
PCI Slot:
x4
x4
X8
X8
Card height:
LP
LP
FH
FH
Slot type:
x8
x8
x8
x8
N8804-009
N8804-011
N8803-038
N8803-039
1
Product Name
SAS board
Max. 1
Max. 1
NEC Corporation
18
8GB
16GB
64GB
128GB
256GB
R320d-E4
2 sec
3 sec
10 sec
18 sec
36 sec
R320d-M4
2 sec
3 sec
8 sec
14 sec
27 sec
About Guest OS
Guest operating systems supported on NEC Express5800/ft series are the same as other general purpose
servers. Refer to the Microsoft web site for Supported Guest Operating Systems on Hyper-V.
Backup
When using Hyper-V on a FT server, prepare a separate server for backup in the same way as for other
general purpose servers with Hyper-V. For backup patterns, refer to each backup software company's web
site.
Active Upgrade
A team assigned to the virtual network by Hyper-V Virtual Network Manager cannot be used in Active
Upgrade. To use Active Upgrade, at least one team that is not assigned to virtual network is required.
NEC Corporation
19
NEC Corporation
20
Revision History
Revision
Date
Description
1.0
2014.3.18
Initial release
NEC Corporation
21