NEC EXPRESS5800/R320d-M4

Configuration Guide
Windows Server
2008 R2 model

Introduction
This document contains product and configuration information that will enable you to configure your system. The
guide will ensure fast and proper configuration of your NEC EXPRESS5800 server.

March 2014
Revision 1.0
NEC Corporation

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Key Features .......................................................................................................................................... 3
Specification .......................................................................................................................................... 3

EXTERNAL VIEWS ......................................................................................................... 5


Front and Rear Views ........................................................................................................................... 5
Dimensions (mm) .................................................................................................................................. 7

CONFIGURATION DIAGRAM ......................................................................................... 8


SERVER CONFIGURATION ........................................................................................... 9
1
2
3
4
5
6

7
8

Base Models ................................................................................................................................... 9


2nd Processor ................................................................................................................................ 9
Memory ........................................................................................................................................... 9
Internal Hard Disk Drives ............................................................................................................ 11
Optical Drive ................................................................................................................................. 11
PCI Card ........................................................................................................................................ 11
6.1 LAN Controller ..................................................................................................................... 11
6.2 Fibre Channel / SAS Controller ........................................................................................... 12
Other Add-in Components .......................................................................................................... 12
7.1 Input Devices ....................................................................................................................... 12
Add-on Components ................................................................................................................... 13
8.1 17-inch LCD Console Drawer .............................................................................................. 13
8.2 KVM Switch ......................................................................................................................... 13
8.3 Flash FDD............................................................................................................................ 13
8.4 Operating System ................................................................................................................ 14
TM
8.5 Active Upgrade ................................................................................................................. 14
8.6 Tower Conversion Kit ........................................................................................................... 14
8.7 External Tape Drives ........................................................................................................... 14

REFERENCES............................................................................................................... 17
Server Management ............................................................................................................................ 17
Supported PCI Cards and Installable Slots ...................................................................................... 18
Notes for using Hyper-V ..................................................................................................................... 19
Copyright Notice and Liability Disclaimer ........................................................................................ 20

REVISION HISTORY ..................................................................................................... 21

NEC Corporation

Revision 1.0, March 2014

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

Technical Specification
Key Features

TM

Fault tolerant technology based on GeminiArchitecture


Full manageability by integrated EXPRESSSCOPE Engine 3
High performance with the latest Intel Xeon processor E5-2600 v2 product family
Up to 256GB of high speed DDR3L-1600 memory

Specification
Model

R320d-M4

Part Number
Processor

N8800-185F
Type

Intel Xeon processor E5-2670 v2

Clock speed

2.50 GHz

Logical Number of
Processors
Cache

1 or 2

Cores and Threads

10C / 20T
TM

Chipset
Memory

Internal Storage

Expansion Slots
[free]
Video

25 MB
Intel C602 Chipset with GeminiEngine

Type

DDR3L-1600 Registered DIMM with ECC

Memory Clock

1600MHz

Logical Standard
Capacity
Logical Maximum
Capacity
Memory protection

0GB

Standard Capacity

0GB

Maximum Logical
Capacity
Disk Controller

9.6 TB (8 x 1.2TB)

RAID

SAS : RAID 1 (Standard)

Hot Plug

Supported

Optical Disk Drive

DVD Super Multi drive

Optical Drive Bays


[free]
Logical Disk Drive Bays
[free]
Standard

1 [0]

Controller (VRAM)

Integrated in Server Management Controller (32MB)

Resolution / Color
Supported

800 x 600 / 16.7M, 1024 x 768 / 16.7M, 1280 x 1024 / 65K

256GB (16 x 16 GB)


ECC, x4 SDDC

SAS: 6Gb/s (Standard)

8 [8]
Total: 4 slots available
2 Low-profile PCIe x4 Gen 2 (x8 connector)
2 Full-height PCIe x8 Gen 2 (x8 connector)

Interfaces

1 VGA (15-pin mini D-sub, 1 rear per system)


4 USB2.0 (1 front, 3 rear per system)
4 10GBASE-T LAN connector (RJ-45, 2 rear per module)
4 1000BASE-T LAN connector (RJ-45, 2 rear per module)
2 Management LAN connector (RJ-45, 1 rear per module)

Server Management

EXPRESSSCOPE Engine 3

Power Supply

2 x 800 Watt (1 per module, 80 PLUS Platinum certified)


100-240 VAC 10% 50 / 60 Hz 3 Hz

NEC Corporation

Revision 1.0, March 2014

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model


Model
Power
(Max. Config,
Consumption
Operating)
Dimensions (W x D x H )

R320d-M4
1,300 VA / 1,290 Watt
483.0 x 736.0 x 178 mm / 19.0 x 29.0 x 7.0 in (4U)

Weight (Minimum / Maximum)

45 kg / 51 kg, 99.21 lbs. / 112.44 lbs.

Temperature, Relative Humidity


(non-condensing)

Operating: 10 to 35 C / 50 to 95 F, 20 to 80%
Non-Operating: -10 to 55 C / 14 to 131 F, 20 to 80%

Regulatory and Safety

FCC, CE, BSMI, CCC, UL, CB, RoHS

Operating Systems

Microsoft Windows Server 2008 R2 Enterprise SP1

Writing software is not provided for this DVD drive.

NEC Corporation

Revision 1.0, March 2014

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

External Views
Front and Rear Views
Front View
B

C D

E
F

H
I
J

B
K

Legend
A.

Drive Bays

L.

CPU Fault LED

B.

UID Button

M.

Memory Fault LED

C.

DVD Super Multi Drive

N.

Module Power LED

D.

System Power LED

O.

SAFE TO PULL LED

E.

System Status LED

P.

PRIMARY LED

F.

System FT LED

Q.

IO Module Fault LED

G.

UID LED

R.

Fan Fault LED

H.

USB Connector

S.

PSU Fault LED

I.

Pull-out Tab

T.

DC Power Fault LED

J.

Power Button

U.

Temperature Fault LED

K.

Module ID LED

NEC Corporation

Revision 1.0, March 2014

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

Rear View
B

Legend
A.

USB Connectors

F.

AC Inlet

B.

Management LAN Connector

G.

PCI Slots (Low-Profile)

C.

Module ID LED

H.

PCI Slots (Full-Height)

D.

Data LAN Connectors (10GBase-T)

I.

Serial Port Connector

E.

Data LAN Connectors (1000Base-T)

J.

VGA Connector

For service personnel only.

NEC Corporation

Revision 1.0, March 2014

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

Dimensions (mm)
Rack mount

748.5
736

177

448

485

688.5

Tower Conversion (Optional)


220

804

592

327

NEC Corporation

Revision 1.0, March 2014

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

Configuration Diagram
Server
CHASSIS
REAR

CHASSIS
FRONT
HDD Bay

HDD Bay

HDD Bay
HDD Bay

HDD Bay

HDD Bay
HDD Bay

HDD Bay

HDD Bay

HDD Bay
HDD Bay

HDD Bay
HDD Bay
HDD Bay

HDD Bay

Backplane

CPU/IO Module

HDD Bay

Optical Drive Bay

CPU/IO Module

PCIe 2.0 x8 (x8 socket) FH

DIMM #8
DIMM #7
DIMM #6
DIMM #5
DIMM #9
DIMM #10
DIMM #11
DIMM #12

HDD Bay
HDD Bay

PCI Riser

Cooling Fan #1 - #4

Processor

CHASSIS
FRONT

HDD Bay

#1
#2
#3
#4

Drive Cage
HDD Bay

DIMM
DIMM
DIMM
DIMM

HDD Bay

CHASSIS
REAR

HDD Bay

CPU/IO module #0 :

Power Supply

#16
#15
#14
#13

DIMM
DIMM
DIMM
DIMM

#1
#2
#3
#4

HDD Bay

DIMM
DIMM
DIMM
DIMM

HDD Bay

Processor
PCIe 2.0 x4 (x8 socket) LP
PCIe 2.0 x4 (x8 socket) LP

HDD Bay
HDD Bay

HDD Bay
HDD Bay

HDD Bay

Drive Cage

HDD Bay

PCIe 2.0 x8 (x8 socket) FH

DIMM #8
DIMM #7
DIMM #6
DIMM #5
DIMM #9
DIMM #10
DIMM #11
DIMM #12

HDD Bay

PCI Riser

Cooling Fan #1 - #4

Processor

HDD Bay

CPU/IO module #1 :

Processor
PCIe 2.0 x4 (x8 socket) LP
PCIe 2.0 x4 (x8 socket) LP

Power Supply

Legend:

NEC Corporation

DIMM
DIMM
DIMM
DIMM

#16
#15
#14
#13

Minimum required components

Revision 1.0, March 2014

Standard components

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

Server Configuration
1 Base Models
Product Name / Description

Part Number

EXPRESS5800/R320d-M4
no RAM, no 2.5-inch HDD
Including:
Intel Xeon Processor E5-2670 v2, 1 x DVD Super Multi, EXPRESSBUILDER DVD

N8800-185F

2 2nd Processor
Available logical sockets: 1
Product Name / Description

Part Number

Intel Xeon Processor E5-2670 v2 2nd Processor Kit : 2.50 GHz / 10C-20T / 25 MB, 2
processors included

N8801-047

3 Memory
Available logical slots: 8 per processor
Product Name / Description

Part Number

4GB DDR3-1600 REG Memory Kit : 2 x 1 x 4GB DIMM included

N8802-060

32GB DDR3-1600 REG Memory Kit : 2 x 4 x 8GB DIMM included

N8802-061

64GB DDR3-1600 REG Memory Kit : 2 x 4 x 16GB DIMM included

N8802-062

NOTE:

Minimum one memory kit must be installed.

NEC Corporation

Revision 1.0, March 2014

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

Memory Configuration Guideline


See the table below for the number of memory kits required in accordance with logical main memory size and number
of logical processors. Memory configurations which are not listed below are not supported in the system.

Number of Logical
Processors

Logical Main Memory


Size

4GB

4GB

32GB

64GB

8GB

12GB

16GB

20GB

24GB

28GB

32GB

48GB

64GB

64GB

96GB

128GB

4GB

8GB

12GB

Number of Memory Kits Required

16GB

24GB

32GB

40GB

10

48GB

12

56GB

14

64GB

16

96GB

128GB

192GB

256GB

Interleave is not supported.

NEC Corporation

Revision 1.0, March 2014

10

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

4 Internal Hard Disk Drives


Available bays: 8
Product Name / Description

Part Number

600GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 600GB

N8850-047

900GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 900GB

N8850-048

1.2TB 10K Hot Plug 2.5-inch SAS HDD : 1 x 1.2TB

N8850-051

146.5GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 146.5GB

N8850-049

300GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 300GB

N8850-050

NOTE:

Hard drives must be installed in identical pairs to configure RAID 1.

Required System Disk Capacity


See the table below for minimum required system disk capacity to store whole memory dump data.
It is recommended to install hard drives providing the minimum required system disk capacity to reduce the
time to resynchronize after a hard drive replacement.
Memory Size

Required System Disk


Capacity

Up to 28GB
32GB to 64GB
96GB to 192GB
256GB

146.5GB
300GB
600GB
900GB

5 Optical Drive
Available bays: 1
Product Name / Description

Part Number

Internal DVD Super Multi Drive : 1 x DVD Super Multi drive, not including writing software

(Standard)

6 PCI Card
6.1 LAN Controller
Category

Product Name / Description

Part Number

LAN Controller

1000BASE-T 2ch board kit : 2 x GbE NIC


Intel Gigabit ET Dual Port Server Adapter
10GBASE-T 1ch Adapter Kit : 2 x 10GbE NIC
Intel X540-T1
NOTE:
- Up to one controller per module
- Installation in full height slots only supported on R320d-M4
- FCoE functionality is not supported

N8804-009
N8804-011

NOTE:

For iSCSI (data) connection, only 1000BASE-T ports (Including standard LAN ports) are supported.

NEC Corporation

Revision 1.0, March 2014

11

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

6.2 Fibre Channel / SAS Controller


Category

Product Name / Description

Part Number

Fibre Channel
Controller

Fibre Channel board kit (8Gbps) : 2 x FC Controller


QLogic QLE2560 8Gbps Fibre Channel Adapters
NOTE: Installation in full height slots only supported on
R320d-M4

N8803-038

SAS Controller

SAS Controller : 1 x SAS Controller


LSI SAS9212-4i4e Host Bus Adapter
NOTE: Up to one controller per module

N8803-039

NOTE:

For supported NEC Storage products to connect with N8803-038, contact your sales representative or
refer to the NEC Storage WEB site. (http://www.nec.com/global/prod/storage/)

7 Other Add-in Components


7.1 Input Devices
Category

Product Name / Description

Part Number

Keyboard

USB Keyboard

N8870-002AF

Mouse

USB Optical Wheel Mouse

N8870-012

Cable

USB cable : 1.5m USB extension cable

K410-177(1A)

NEC Corporation

Revision 1.0, March 2014

12

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

8 Add-on Components
8.1 17-inch LCD Console Drawer
Category
Drawer
w/ KVM
Switch

Product Name / Description

Part Number

Drawer

17inch LCD Console Unit (1U/8port)


17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM
switch, 1U height

N8143-77F

Cable

Switch Unit Connection Cable Set (USB, 1.8m)


1.8 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x
4-pin USB A
Switch Unit Connection Cable Set (USB, 3m)
3 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB, 5m)
5 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin
USB A
17inch LCD Console Unit 1U
17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height,
4-pin USB B to 4-pin USB A cable 2m, PS/2 Y-splitter cable 2m,
15-pin mini D-sub VGA cable 2m
17inch LCD Console Drawer (1port)
17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad
with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8
m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m
Keyboard Unit (JP)
JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD
Console Drawer (1port)
Keyboard Unit (UK)
UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD
Console Drawer (1port)

K410-118(1A)

Drawer

Drawer
w/o KVM
Switch

Keypad

K410-118(03)

K410-118(05)

N8143-76F

N8143-84F

N8143-85

N8143-87

8.2 KVM Switch


Category

Product Name / Description

Part Number

KVM Switch

Server Switch Unit (8 server)


1U USB 8 port KVM switch

N8191-12F

Switch Unit Connection Cable Set (USB,1.8m)


1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable 1.8 m
1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2

K410-118(1A)

Cable

KVM

Cascading

K410-118(03)

K410-118(05)

K410-119(1A)

8.3 Flash FDD


Order the Flash FDD if you need to prepare an alternative for a floppy drive.
Product Name / Description

Part Number

Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB

N8160-86

NEC Corporation

Revision 1.0, March 2014

13

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

8.4 Operating System


Product Name / Description

Part Number

Microsoft Windows Server 2008 R2 Enterprise (1-2 Processor, 25CAL Version):


English

UL0999-436EN

Chinese Traditional

UL0999-436CT

Chinese Simplified

UL0999-436CS

Korean

UL0999-436KR

NOTE:

Service Pack1 is not included in these products. Service Pack1 needs to be applied separately.

8.5 Active UpgradeTM


Product Name / Description

Part Number

Active Upgrade for ft

UL1535-001E

8.6 Tower Conversion Kit


Product Name / Description

Part Number

Tower Conversion Kit


23 inch height pedestal with front bezel

N8843-004

8.7 External Tape Drives


8.7.1 Tape Drive Selection
Refer to the section in accordance with your type of tape drives.
LTO

NEC Corporation

LTO3

SAS

Refer to 8.7.2

LTO4

SAS

Refer to8.7.2

LTO5

SAS

Refer to 8.7.2

LTO6

SAS

Refer to 8.7.2

Revision 1.0, March 2014

14

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

8.7.2 LTO / SAS


Category

Product Name / Description

Part Number

Controller
Required

N8803-039

External Cable
Required

SAS Controller
LSI SAS9212-4i4e Host Bus Adapter
6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8,
LP/FH
NOTE: Up to one controller per module
External SAS cable
2 m, for Tape Drive Enclosure connection

Tape Enclosure
Required

2U Tape Drive Enclosure


4 x 5-inch media bays, two internal SAS cables included

N8141-59F

Power Module
Recommended

Power Supply
1 x non-hot plug power supply unit for redundant configuration

N8181-54F

Internal Cable

Internal SAS cable


2 m, for 2U Tape Drive Enclosure internal connection
NOTE: Required when three or more SAS connections
(including other general purpose servers) to the N8141-59F

K410-249(00)

Drive
2 bays available

Internal LTO (SAS)


LTO3, Half height, Native capacity 400GB
Internal LTO (SAS)
LTO4, Half height, Native capacity 800GB
Internal LTO (SAS)
LTO5, Half height, Native capacity 1500GB
Internal LTO (SAS)

N8151-102

K410-191(02)

N8151-90
N8151-103
N8151-106

LTO6, Half height, Native capacity 2.5 TB

8.7.3 Notes for Double Backup


In a single backup configuration, in case a CPU/IO module or backup device fails, backup is not possible
until the failed part is repaired or replaced. If this does not meet your system requirements, consider a
double backup configuration.
Refer to the following notes on double backup configuration.

When configuring two sets of a SAS controller, a SAS cable and a backup device, two backup devices
are recognized separately by the OS. When scheduling an automatic backup job, make a job for each
backup device so that the other backup device can backup in case one device fails.
With BrightStor ARCserve Backup, backup is not executed if you enter an asterisk (*) in the group box
under the destination tab when defining a job. Be sure to create two backup jobs by correctly selecting
the device group for the group box, and entering an asterisk (*) or the name of the media in the media
box.

NEC Corporation

Revision 1.0, March 2014

15

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

8.7.4 Supported Backup Software


See the table below for the supported backup software on NEC EXPRESS5800/R320d.
Tape drive
Product Name / Description

Backup software
Part Number

ARCserve

Backup Exec

ARCserve r16.5

Backup Exec 2012

WS2008R2

WS2008R2

Internal LTO (SAS)


LTO3, Half height, Native capacity 400 GB

N8151-102

*a1

*b1

Internal LTO (SAS)


LTO4, Half height, Native capacity 800 GB

N8151-90

*a1

*b1

N8151-103

*a1

*b1

N8151-106

*a1

*b1

Internal LTO (SAS)


LTO5, Half height, Native capacity 1.5 TB
Internal LTO (SAS)
LTO6, Half height, Native capacity 2.5 TB

*a1: Do not disable the tape driver on the device manager.


*b1: Do not install the Symantec driver. Apply the driver which comes with the tape drive.
NOTE:

Disaster Recovery Option is not supported on the ft server system.


It is not supported to backup from NEC Express5800/ft series to a backup device directly using
NetBackup. However, NEC Express5800/ft series can be a backup-client machine of NetBackup.

NEC Corporation

Revision 1.0, March 2014

16

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

References
Server Management
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system
management features listed in the table below.

Temperature/voltage/power/
fan /degeneration (memory/hard drive)

Hardware event log collection

Boot monitoring

Booting, BIOS/POST stall, OS stall,


shutdown

Alerting

HW error, Boot error and OS panic


(by SNMP, E-Mail)

Remote KVM

POST/BIOS setup, DOS utility

(via LAN)

Panic screen, Boot screen

Text-based screen (OS console)

GUI-based screen (OS console)

Remote control

Remote reset/power on-off/ dump

(via LAN)

OS shutdown

Remote media (CD/DVD/FD)

Server Management Command Line


Protocol (DMTF compliant)

Remote control via Web browser


(without dedicated app)

Remote batch

Scheduling (without UPS)

Others

Set automatic IP address via DNS/DHCP

Remote wakeup

Wake On LAN, Wake On Ring

Centralized
management
Industry standard

Monitoring and control of multiple servers

IPMI

2.0

Hardware
monitoring

NEC Corporation

Revision 1.0, March 2014

17

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

Supported PCI Cards and Installable Slots


Part Number

Slots

Notes

Slot # :

#1

#2

#3

#4

PCI Slot:

x4

x4

X8

X8

Card height:

LP

LP

FH

FH

Slot type:

x8

x8

x8

x8

N8804-009

1000BASE-T 2ch board kit

N8804-011

10GBASE-T 1ch board set

N8803-038
N8803-039
1

Product Name

Fibre Channel board kit

SAS board

Max. 1

Max. 1

Not installable when using Tower Conversion Kit.

NEC Corporation

Revision 1.0, March 2014

18

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

Notes for using Hyper-V


Brief system interruption during synchronization process
In the synchronization process of CPU modules, a memory copy is performed to duplex memory on both
CPU modules. Most of the memory area can be copied without interrupting the system through the
so-called brownout copy method, and just a small portion requires the system to stop. However, with
Hyper-V, the system cannot use the brownout copy method. Therefore, the system does not respond for a
longer period of time during the synchronization process of the CPU modules than without Hyper-V.
See the table below for the reference values of interruption during re-synchronization of CPU/IO modules in
a Hyper-V system. It is recommended that your system design take the interruption into account.
Model / Memory Size

8GB

16GB

64GB

128GB

256GB

R320d-E4

2 sec

3 sec

10 sec

18 sec

36 sec

R320d-M4

2 sec

3 sec

8 sec

14 sec

27 sec

About Guest OS
Guest operating systems supported on NEC Express5800/ft series are the same as other general purpose
servers. Refer to the Microsoft web site for Supported Guest Operating Systems on Hyper-V.

Backup
When using Hyper-V on a FT server, prepare a separate server for backup in the same way as for other
general purpose servers with Hyper-V. For backup patterns, refer to each backup software company's web
site.

NEC ESMPRO Agent


For monitoring guest operating systems, NEC ESMPRO Agent for Guest OS is required. Contact your
sales representative for this software.

Active Upgrade
A team assigned to the virtual network by Hyper-V Virtual Network Manager cannot be used in Active
Upgrade. To use Active Upgrade, at least one team that is not assigned to virtual network is required.

NEC Corporation

Revision 1.0, March 2014

19

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

Copyright Notice and Liability Disclaimer


The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries
Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United
States and other countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks
of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.

NEC Corporation

Revision 1.0, March 2014

20

CONFIGURATION GUIDE NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model

Revision History
Revision

Date

Description

1.0

2014.3.18

Initial release

NEC Corporation

Revision 1.0, March 2014

21

You might also like