PSC Design (EC2) Tutorial PDF
PSC Design (EC2) Tutorial PDF
Advanced Application
Prestressed Box Girder Design
as per EN1992-2:05
ADVANCED APPLICATIONS
1.
2.
3.
4.
5.
6.
7.
Overview
File opening and Preferences setting
Checking Model Data
Reinforcement Input
Performing Structural Analysis
PSC Section Design
Checking Design Results
Overview
Design procedure for PSC section is as follows.
Modeling
Structural Analysis
ADVANCED APPLICATIONS
125.000
40.000
4.000 4.000
L OF PIERC
P2
Construction
Direction
RP2
4.000 4.000
37.000
Construction
Joint
RP1
Construction
Joint
32.000
L OF PIERC
A1
Unit: m
Unit: m
P2
L=35.850X1X12EA=430.200
L=47.000X1X12EA=564.000
L=47.000X1X12EA=564.000
Unit: m
L=35.850X1X12EA=430.200
L=49.500X1X19EA=940.500
L=50.500X1X19EA=959.500
L=49.500X1X19EA=940.500
L=49.500X1X19EA=940.500
L=37.500X1X19EA=712.500
L=49.500X1X19EA=940.500
L=50.500X1X19EA=959.500
L=33.500X1X19EA=636.500
L=46.500X1X19EA=883.500
L=49.500X1X19EA=940.500
L=50.500X1X19EA=959.500
L=33.500X1X19EA=636.500
L=33.500X1X19EA=636.500
L=46.500X1X19EA=883.500
L=50.500X1X19EA=959.500
L=33.500X1X19EA=636.500
L=46.500X1X19EA=883.500
32.000
L=49.500X1X19EA=940.500
Construction Joint
4.000
4.000
AIR VENT
RP1
L OF PIERC
L=49.500X1X19EA=940.500
37.000
Construction Joint
125.000
L=46.500X1X19EA=883.500
4.000
AIR VENT
RP2
L OF PIERC
4.000
L=49.500X1X19EA=940.500
Construction Direction
40.000
A1
ADVANCED APPLICATIONS
Material Properties
Tendon Properties
Material: EN 05(S) Y1770S7
P.C Strand: 15.2 mm (0.6strand)
Yield Strength: fpy = 1600 N/mm2
Ultimate Strength: fpu = 1900 N/mm2
Cross Sectional area: Ap = 2635.3 mm2
Duct Diameter = 103 mm
Modulus of Elasticity: Eps = 1.95 X 105 N/mm2
Jacking Stress: fpj = 0.7fpu = 1330 N/mm2
Curvature friction factor: = 0.3 /rad
Wobble friction factor: k = 0.0066 /m
Anchorage Slip: s = 6 mm (At the Beginning and at the End)
Load
Dead Load
Self-weight
Input Self-Weight
Superimposed dead load
w = 35.796 kN/m
Pre Stress
Strand (15.2 mm19 (0.6- 19))
Area: Ap = 2635.3 mm2
Duct Size: 103 mm
Prestressing force: 70 % of ultimate strength.
Live loads
Condition
A. Vehicle Load : Load Model 1
B. Psi Factor : LM1 Tandem :
LM1 UDL:
RA 1
0.75
0.4
Distribution of Lanes
Lane 1
Lane 2
RA 2
ADVANCED APPLICATIONS
Support Settlement
Consider each pier undergoing the support settlement of 10 mm under
unfavorable condition.
Temperature Loads
Temperature difference (approach 2 in EN 1991-1-5)
Fig.6
Wind Loads
Wind Load: 3 kN/m2
3 kN/m2
1.46
ADVANCED APPLICATIONS
File >
10
Open Project
Open
11
ADVANCED APPLICATIONS
Reinforcement Input
In this tutorial,
the arrangement of
longitudinal rebars
has been simplified
for convenience.
12
13
ADVANCED APPLICATIONS
By checking on
Both end parts (i &
j) have the same
reinforcement, the
reinforcement data
of one part will be
copied to another.
14
Consider
the
reinforcement
entered into the PSC
section
for
the
calculation
of
section properties.
If this option is
checked off, the
reinforcement will
not be considered
for calculation of
section properties.
15
ADVANCED APPLICATIONS
Load Combination
In this tutorial we will generate the following load combinations
based on the Bridge Design Specification (EUROCODE).
ULS
1.35Gk + P + 1.35(TS+UDL) + 1.5(0.6Fwk)
1.35Gk + P + 1.5Tk + 1.35(0.75TS+0.4UDL)
1.35Gk + P + 1.5Fwk
SLS
Characteristic
Gk + P + (TS+UDL) + (0.6Fwk)
Gk + P + Tk + (0.75TS+0.4UDL)
Gk + P + Fwk
Frequent
Gk + P + (0.75TS+0.4UDL)+ (0.5Tk)
Gk + P + (0.6Tk)
Gk + P + (0.2Fwk)
Quasi-permanent
Gk + P + (0.5Tk)
16
17
ADVANCED APPLICATIONS
18
19
ADVANCED APPLICATIONS
STEP 2
Classify Load Cases
20
STEP 3
Classify Load Combinations
PSC > Serviceability Load Combination
Classify serviceability load combinations into sub-category,
i.e. Characteristic, Frequent, Quasi-permanent.
21
ADVANCED APPLICATIONS
STEP 4
Modify material properties
PSC > PSC Design Material
Material List> ID1
Concrete Material Selection
Code> EN04(RC)
Grade>C40/50
Rebar Selection
Code> EN04(RC)
Grade of Main Rebar>Class A
Grade of Sub-Rebar>Class A
22
23
ADVANCED APPLICATIONS
STEP 5
Select Locations for PSC Design
Using this function we can select the elements and their ends (only I, only
J or both I & J) to be checked for moment or shear or both, for PSC. If we
do not select specific locations for check, both parts (I&J) of all the
elements will be checked for both moment and shear.
PSC > PSC Design Option
Option>Add/Replace
Select All
Moment> I &J (on)
Shear> I &J (on)
24
STEP 6
Select location for output
Using this feature we can select the ends of elements for which flexural
and (or) shear and (or) torsion strength are to be produced in output report
(in excel sheet) generated from PSC Design Calculation after PSC
Design. It is important to note that output can be produced only for those
elements which have been assigned PSC Design Option.
In the following example, we will print the flexure, shear and torsion
strength of the elements in the central span and at support.
PSC > PSC Print Option
Option : Add/Replace
Select Elements by Identifying (Element: 16, 26)
Moment Strength> M (+) >J (on)
Moment Strength> M (-) >J (on)
Shear Strength> J (on)
Torsion Strength> J (on)
Click [Apply]
25
ADVANCED APPLICATIONS
STEP 7
Exposure Class
This feature enables the user to provide exposure classes specific to each
element and at the Top and Bottom surface of a section. Like other
functions user can edit in tabular format also. By default if not assigned
the Class XC1 is applied at both top and bottom surfaces.
26
STEP 8
Perform the PSC Design
PSC > Perform Design
27
ADVANCED APPLICATIONS
Design Results
We can see the design results in Tables (Design>PSC Design>PSC
Design Result Tables). We can also check the design calculation in
excel sheet format. This design result corresponds to the Input and
Output parameters defined in PSC Design Parameters.
PSC Design Calculation
It produces PSC design results in excel format for the elements selected
in PSC Print Option.
This sheet can be generated in Post CS stage and if the number of
selected elements is larger, it takes longer time to generate the sheet.
The excel sheet is saved in the saved folder of model files (*.mcb).
PSC > PSC Design Calculations
28
29
ADVANCED APPLICATIONS
Table Parameters
30
Elem
Element number
M Rd
Nominal moment
Part
M Ed / M Rd
moment ratio
Positive/
Negative
positive moment,
negative moment
As,min
minimum required
reinforcing steel area
LCom
Name
Type
Check
OK/NG
Calculations
M Rd , Bending resistance
(1) Determine the distance between the temporary neutral axis and the
extreme fiber of concrete that is in compression. When the strain of
compression extreme fiber is cu 2 or cu 3 , calculate strain s and p for
reinforced and Prestressing steel.
(2) Calculate Fc (Concrete), Fs (Steel) and Fp (Tendon)
Fc x fcd
Fs f s As , f s s Es
Fp f p Ap , f p p E p ,
p p p (0)
Note: For Unbonded Tendons value of
p = 100/Ep
(3) C T
Fc ( Fs Fp )
(4) Determine depth of the neutral axis (x)
Repeat 1) ~2) to satisfy (3) (by trial and error)
(5) M Rd , bending resistance
From the determined neutral axis depth, calculate M Rd
31
ADVANCED APPLICATIONS
32
Table Parameters
Elem
Part
Max/Min
LCom
Name
Type
Check
Element number
location of check (I-end, Jend)
maximum/minimum shear
force
Load combination name
produce maximum and
minimum member force
components for the load
combinations including
moving load cases
OK/NG
VEd
VRd
shear resistance
VRd ,max
shear resistance of
Concrete
shear resistance of
shear reinforcement
maximum VRd ,s
VEd /
VRd
VRd ,c
VRd ,s
33
ADVANCED APPLICATIONS
Calculations
Shear resistance VRd ,c
With a minimum of
VRd ,c (vmin k1 cp ) bwd
VRd , c
Ibw
S
fctd 2 l cp fctd
VRd , s
Asw
zf ywd cot
s
VRd , s
1
cw 1 f cd
2
Asw
zf ywd (cot cot ) sin
s
and
VRd ,max cwbw z 1 f cd /(cot cot ) /(1 cot 2 )
34
Asw,max f ywd
bw s
1
2
cw 1 f cd
sin
is determined for
the most
Unfavorable level
For grouted metal ducts with bw / 8 , bw, nom bw
For non-grouted ducts, grouted plastic ducts and unbonded tendons
bw, nom bw 1.2
35
ADVANCED APPLICATIONS
Table Parameters
Elem
Element number
TEd
Part
TRd ,max
Max/Min
LCom
Name
Type
Check
36
VEd
VRd ,s
VRd ,max
Calculations
VRd ,max : VRd ,max cwbw z 1 f cd /(cot cot ) /(1 cot 2 )
37
ADVANCED APPLICATIONS
Table Parameters
Elem
Part
Comp/Tens
Stage
CHK
FT
FB
Element number
Check location (I-end, Jend)
Compression, Tension
Construction stage
Combined stress check for
construction stages
Top fiber stress
Bottom fiber stress
FTL
FBL
FTR
FBR
FMAX
ALW
allowable stress
Calculations
Calculate allowable stress
The concrete compressive stress in the structure
c 0.6 fck (t )
For pretension elements, k6 fck (t )
Tensile strength
f ctm (t ) ( cc (t )) f ctm
38
Table Parameters
Tendon
FDL1
FDL2
FLL
39
ADVANCED APPLICATIONS
Calculations
Maximum stress applied to the tendon (AFDL1)
p = k5 f pk
k 5 The recommended value 0.75
40
Table Parameters
Elem
Part
Comp/Tens
LCom Name
Type
FT
FB
Element number
Check location (I-end, J-end)
Compression, Tension
load combination name
produce maximum and minimum
member force components for
the load combinations including
moving load cases
top fiber stress
bottom fibre stress
FTL
FBL
FTR
FBR
FMAX
ALW
allowable stress
Calculations
Calculate allowable stress
Allowable compressive stress
c k1 f ck
Note: k1 from National Annex. The recommended value is 0.6
Allowable tensile stress
ct f ctm
41
ADVANCED APPLICATIONS
Table Parameters
Elem
Element number
Sig_P5
Part
Sig_P6
Comp/T
ens
Stage
Compression, tension
Sig_P7
construction stage
Sig_P8
CHK
Sig_P9
Sig_P3
Sig_AP
Sig_P4
Sig_P1
Sig_P2
42
Sig_P10
Sig_MAX
Table Parameters
Elem
Element number
Sig_P4
Part
Sig_P5
Comp/Te
ns
LCom
Name
Compression, tension
Sig_P6
Type
produce
maximum
and
minimum
member
force
components for the load
combinations
including
moving load cases
principal stress check at
service loads
principal stress at the left top of
top flange
principal stress at the right top
of top flange
principal stress at the right
bottom of bottom flange
CHK
Sig_P1
Sig_P2
Sig_P3
Sig_P8
principal stress at the center of
right web
Sig_P9
Sig_P10
Sig_MAX
Sig_AP
43
ADVANCED APPLICATIONS
Table Parameters
produce maximum and minimum
member force components for
Elem
Element number
Type
Part
Top/Botto
m
LCom
Name
Servicea
bility
Load
Type
44
Check
OK/NG
wk
crack
wmax
allowable crack
Frequent/ Quassi-Static
Calculations
wk sr ,max ( sm cm )
s kt
sm cm
f ct ,eff
p ,eff
(1 e p ,eff )
Es
0.6
s
Es
n112 n222
n11 n22
If,
spacing 5(c / 2) ,
sr ,max 1.3(h x)
Check crack
wk wmax
wmax = Table 7.101N-Recommended value of
wmax
and relevant
combination rules
45
ADVANCED APPLICATIONS
Table Parameters
Elem
Element number
Fy
Part
Fz
LCom
Name
Type
Fx
46
Mx
My
Mz
If Safety factor is
chosen, the program
displays
the
ratio
diagram of design
forces to strengths.
47
ADVANCED APPLICATIONS
48
Excel Report
MS Excel format report is generated for the engineers verification.
PSC > Excel Report
49