0% found this document useful (0 votes)
313 views

Contactor NC1

1) The document provides specifications for contactors, including technical details such as ratings, dimensions, accessories, and derived products. 2) It describes contactor types for AC and DC coils in various frames and current ratings from 9A to 95A. 3) Accessories like auxiliary contacts, time delay modules, and thermal overloads are also discussed along with how they integrate with contactors.

Uploaded by

Nguyen Phi Hung
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
313 views

Contactor NC1

1) The document provides specifications for contactors, including technical details such as ratings, dimensions, accessories, and derived products. 2) It describes contactor types for AC and DC coils in various frames and current ratings from 9A to 95A. 3) Accessories like auxiliary contacts, time delay modules, and thermal overloads are also discussed along with how they integrate with contactors.

Uploaded by

Nguyen Phi Hung
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

Contactors, Relays, Starters

Contactors
2. Type designation
N C 1- -

Z: DC coil Blank: AC coil

Number of contacts
10: 3 N/O main contacts+1 N/O auxiliary
contact (9A,12A,18A,25A,32A)
01: 3 N/O main contacts+1 N/C auxiliary
contact (9A,12A,18A,25A,32A)
11: 3 N/O main contacts+1 N/O
and 1N/C auxiliary contact
(40A,50A,65A,80A,95A)
04: 4 N/O main contacts
(9A,12A,25A,40A,50A,65A,80A,95A)
08: 2 N/O and 2N/C main contacts
(9A,12A,25A,40A,50A,65A,80A,95A)

NC1 Contactor, 9~95A


1. General
1.1 Certificates: CE, KEMA, VDE, EK, ESC, UKrSEPRO, GOST,
RCC, UL;
1.2 Electric ratings: AC50/60Hz, 690V, up to 95A;
1.3 Application: remote making & breaking circuits;
protect circuit from over-load when assembling
with thermal over-load relay;
Frequent start-up and control of AC contactor;
1.4 Utilization category: AC-3, AC-4;
1.5 Altitude: 2000m;
1.6 Ambient temperature: -5~+40;
1.7 Mounting category:
1.8 Mounting conditions:
inclination between the mounting plane
and the vertical plane should not exceed 5
1.9 Standard: IEC/EN 60947-4-1

Basic specification, expressed


with the rated operational current
(380V/400V, AC-3)

Design sequence No.

Contactor

Company code

US LISTED

D-51

> >>

Contactors, Relays, Starters

Contactors
3. Curves

AC3 AC4 Load

95

80

65

50

40

32

25

18

0.2
0.1
0.08
0.04
0.02
0.01

440V

200 400 800

2000 4000
Breaking current (A)

30
37
45
55
75
90
110
132
160
200
220
250
315

40 80 100

7.5
10
11
15
18.5
22

2.2
3
4
5.5

20

(kW)
(kW)

75
90
110
132
160
200
220
250
315

30
37
45

5.5
7.5
11
15
18.5
22

2.2
3
4
5.5
7.5
10
11
15
18.5
22
30
75
45
55
75
90
110
132
160
200
250
315
335
400

220/230V
380/400V

8 10

0.75
1.1

2.2
3

0.55

AC4

1.1
1.5

AC3

0.75

AC2
Utilization categories

AC2/AC3/AC4

10
8
4
2
1
0.8
0.4

1.1
1.5

Current breaking limits

12

106

09

Electric
life

(kW)

> >>

D-52

Contactors, Relays, Starters

Contactors
4. Technical data
4.1 AC coil contactor

AC coil operation
Items

NC1-09

Model
Frame

380/400V
660/690V

32

12

18

25

AC-4

3.5

7.7

8.5

AC-3

6.6

8.9

12

18

AC-4

1.5

3.8

4.4

690

690

690

690

2.2

5.5

380/400V AC

5.5

7.5

11

660/690V AC

5.5

7.5

10

15

200V AC

7.5

7.5

240V AC

7.5

10

460V AC

7.5

10

15

600V AC

7.5

10

15

AC-3
AC-4

1,200
300

1,200
300

1,200
300

1,200
300

Mechanical

3,600

3,600

3,600

3,600

AC-3

1,000

1,000

1,000

1,000

AC-4

200

200

200

200

10

10

10

10

RT16-20

RT16-20

RT16-32

RT16-40

hp

Electrical

Electrical life
(103 operations)
6

Mechanical life (10 operations)


Matched fuse type

D-53

> >>

40

20

220/230V AC
kW

Operating frequency
(operations/h)

NC1-25
Frame 3 (3P, 4P)

20

Rated insulation voltage (V AC)

Power of controlled
3-phase
cage motor (AC-3)

NC1-18
Frame 2 (3P)

AC-3

Rated conventional heating current (A) AC-1


Rated operational
current (A)

NC1-12

Frame 1 (3P, 4P)

Contactors, Relays, Starters

Contactors

NC1-32

NC1-40

Frame 4 (3P)

50

NC1-50

NC1-65

NC1-80

Frame 5 (3P, 4P)

NC1-95
Frame 6 (3P, 4P)

60

80

80

95

95

32

40

50

65

80

95

12

18.5

24

28

37

44

21

34

39

42

49

49

7.5

12

14

17.3

21.3

690

690

690

690

690

690

7.5

11

15

18.5

22

25

15

18.5

22

30

37

45

18.5

30

37

37

45

45

10

15

15

20

25

30

15

20

20

25

30

30

20

25

30

40

40

50

20

25

30

40

40

50

600
300

600
300

600
300

600
300

600
300

600
300

3,600

3,600

3,600

3,600

3,600

3,600

800

800

600

600

600

600

200

150

150

150

100

100

RT16-50

RT16-63

RT16-80

RT16-80

RT16-100

RT16-125

> >>

D-54

Contactors, Relays, Starters

Contactors
4.2 DC coil contactor

DC coil operation(24V,110V,220V)
Items

NC1-09Z

Model
Frame

Rated conventional heating current (A) AC-1

20

32

40

12

18

25

AC-4

3.5

7.7

8.5

AC-3

6.6

8.9

12

18

AC-4

1.5

3.8

4.4

20

20

32

40

690

690

690

690

2.2

5.5

380/400V AC

5.5

7.5

11

660/690V AC

5.5

7.5

10

15

AC-3

1,200

1,200

1,200

1,200

300

300

300

300

660/690V
Conventional heating current (A)
Rated insulation voltage (V AC)

220/230V AC
kW

Operating frequency

Electrical

NC1-25Z
Frame 3 (3P, 4P)

20

current (A)

Power of controlled
3-phase
cage motor (AC-3)

NC1-18Z
Frame 2 (3P)

AC-3

380/400V

Rated operational

NC1-12Z

Frame 1 (3P, 4P)

AC-4

(operations/h)

Mechanical

3,600

3,600

3,600

3,600

Electrical life

AC-3

1,000

1,000

1,000

1,000

(103 operations)

AC-4

200

200

200

200

Mechanical life (10 operations)


Matched fuse type

D-55

> >>

10

10

10

10

RT16-20

RT16-20

RT16-32

RT16-40

Contactors, Relays, Starters

Contactors

NC1-32Z

NC1-40Z

Frame 4 (3P)

NC1-50Z

NC1-65Z

NC1-80Z

Frame 5 (3P, 4P)

NC1-95Z
Frame 6 (3P, 4P)

50

60

80

80

95

95

32

40

50

65

80

95

12

18.5

24

28

37

44

21

34

39

42

49

49

7.5

12

14

17.3

21.3

50

60

80

80

95

95

690

690

690

690

690

690

7.5

11

15

18.5

22

25

15

18.5

22

30

37

45

18.5

30

37

37

45

45

600

600

600

600

600

600

300

300

300

300

300

300

3,600

3,600

3,600

3,600

3,600

3,600

800

800

600

600

600

600

200

150

150

150

100

100

RT16-50

RT16-63

RT16-80

RT16-80

RT16-100

RT16-125

> >>

D-56

Contactors, Relays, Starters

Contactors
5. Accessories
5.1 Accessories
Items
Coil
power
AC coil

Model

NC1-09(Z)

NC1-12(Z)

NC1-18(Z)

NC1-25(Z)

NC1-32(Z

In-rush (VA)

70

70

70

110

110

Sealed (VA)

9.5

14

14

Power (W)

1.8~2.7

1.8~2.7

3~4

3~4

3~4

Operation

Operation voltage

(85%~110%) Us

range

Drop-out voltage

(20%~75%) Us

Coil voltage(50Hz,60Hz,

24,36,48,110,127,220,240,380,415,440,480,500,600,660

50/60Hz)(V)
Coil power(W)
DC coil

Operation
range

11

Pick-up voltage

(85%~110%) Us

Drop-out voltage

(10%~75%) Us

Coil voltage (V)

24,36,48,110,220

F4 -
Number of N/C auxiliary contact
Number of N/O auxiliary contact
Auxiliary contact assembly

F4 auxiliary contact

F5 -
0: time-delay range, 0.1s~3s
2: time-delay range, 0.1s~30s
4: time-delay range, 10s~180s
T: making time-delay; D: breaking time-delay
Time-delay module

F5 auxiliary contact

NCF1-11C

NCF1-11C lateral side auxiliary contact

D-57

> >>

Lateral side
1 N/C contact
1 N/O contact
Design sequence No.
Auxiliary contact assembly
Contactor
Company code

11

11

Z)

Contactors, Relays, Starters

Contactors

NC1-40(Z)

NC1-50(Z)

NC1-65(Z)

NC1-80(Z)

NC1-95(Z)

200

200

200

200

200

57

57

57

57

57

6~10

6~10

6~10

6~10

6~10

(85%~110%) Us
(20%~75%) Us
24,36,48,110,127,220,240,380,415,440,480,500,600
20

20

20

20

20

(85%~110%) Us
(10%~75%) Us

Picture

Picture

Model

Configuration of contacts
Number of N/O contact

Number of N/C contact

F4-20

F4-11

F4-02

F4-40

F4-31

F4-22

F4-13

F4-04

Model

Time-delay range

Number of time-delay contacts

F5-T0

0.1s~3s

N/O+N/C

F5-T2

0.1s~30s

N/O+N/C

F5-T4

10s~180s

N/O+N/C

F5-D0

0.1s~3s

N/O+N/C

F5-D2

0.1s~30s

N/O+N/C

F5-D4

10s~180s

N/O+N/C

> >>

D-58

Contactors, Relays, Starters

Contactors
5.2 Derived products when the contactor is assembled with following accessory module
Derived products

Contactor

Accessorial modular

Time-delay contactor
Time-delay block

Reversing contactor
Mechanical interlock

Magnetic starter

Thermal relay

AC contactor for
capacitor switching
Current-limiting
contact assembly

Star-delta starter
Time-delay block

D-59

> >>

Auxiliary
contact assembly

Picture

Contactors, Relays, Starters

Contactors
5.3 Assembly with thermal over-load relay
Model of
contactor

Assembled thermal over-load relay


Model

NC1-09
NC1-12
NC1-18
NR2-11.5

NC1-09
NC1-12
NC1-18

NR2-11.5

NC1-09
NC1-12
NC1-18
NC1-25
NC1-32

NR2-25

Rated current (A)

Recommended fuse type


aM

gG

0.1~0.16

0.25

0.16~0.25

0.5

0.25~0.4

0.4~0.63

0.63~1

1~1.6

1.25~2

1.6~2.5

2.5~4

10

4~6

16

5.5~8

12

20

7~10

12

20

9~13

16

25

0.1~0.16

0.25

0.16~0.25

0.5

0.25~0.4

0.4~0.63

0.63~1

1~1.6

1.25~2

1.6~2.5

2.5~4

10

4~6

16

5.5~8

12

20

7~10

12

20

9~13

16

25

12~18

20

35

17~25

25

50

23~32

40

63

28~36

40

80

23~32

40

63

30~40

40

100

37~50

63

100

48~65

63

100

55~70

80

125

63~80

80

125

80~93

100

160

NC1-32

NR2-36

NC1-40
NC1-50
NC1-65
NC1-80
NC1-95
NR2-93

> >>

D-60

Contactors, Relays, Starters

Contactors
5.4 Assembly with electronic overload relay
Model of
contactor

Model

NC1-09

NC1-12
NC1-18
NC1-25
NC1-32

NRE8-25

NC1-40

NRE8-40

Rated

Range of setting

Recommended

Assembled thermal
current (A)

Over-load relay
current (A)

Fuse type

1.2
2.4
4
8
10
12
20
25
32

0.6~1.2
1.2~2.4
2~4
4~8
5~10
7~12
10~20
20~25
22~32

RT36-4 (NT00-4)
RT36-6 (NT00-6)
RT36-10 (NT00-10)
RT36-16 (NT00-16)
RT36-20 (NT00-20)
RT36-25 (NT00-25)
RT36-40 (NT00-40)
RT36-50 (NT00-50)
RT36-80 (NT00-80)

2~4

RT36-10 (NT00-10)

4~8

RT36-16 (NT00-16)

10

5~10

RT36-20 (NT00-20)

20

10~20

RT36-40 (NT00-40)

40

20~40

RT36-80 (NT00-80)

65

30~65

RT36-160 (NT00-160)

100

50~100

RT36-200 (NT1-200)

NC1-40
NC1-50
NC1-65
NC1-80
NC1-95

NRE8-100

6. Technical information
6.1 Terminal connection
Cabling cross section(Cu)
Screw
size

Tightening
torque (Nm)

1/4
1/4

M3.5
M3.5

0.8
0.8

1/4
12.5

1/4
1/4

M3.5
M3.5

0.8
0.8

1.5/4
1.5/4

1.5/6
1.5/4

1.5/6
1.5/6

M3.5
M3.5

0.8
0.8

1.5/4
1.5/4
2.5/6
2.5/6
6/25
4/10
6/25
4/10
6/25
4/10
10/35
6/16
10/35
6/16

1.5/10
1.5/6
2.5/10
2.5/6
6/25
4/10
6/25
4/10
6/25
4/10
10/35
6/16
10/35
6/16

1.5/6
1.5/6
2.5/10
2.5/10
6/25
4/10
6/25
4/10
6/25
4/10
10/35
6/16
10/35
6/16

M4
M4
M4
M4
M4
M8
M8
M8
M8
M8
M10
M10
M10
M10

1.2
1.2
1.2
1.2
3.5
3.5
3.5
3.5
3.5
3.5
4.0
4.0
4.0
4.0

Number
of piece

Flexible cable
with cold-pressed
2
socket (mm )

Flexible cable
without cold2
pressed socket (mm )

Inflexible
cable (mm2)

NC1-09

1
2

1/2.5
1/2.5

1/4
1/2.5

NC1-12

1
2

1/2.5
1/2.5

NC1-18

1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2

Model

NC1-25
NC1-32
NC1-40
NC1-50
NC1-65
NC1-80
NC1-95

D-61

> >>

Contactors, Relays, Starters

Contactors
7. Overall and mounting dimensions (mm)

NC1-09~32

D(F 4)/E (F 5)

D
NC1-40~95

D(F4)/E(F5)

a
A

NC1-09Z~32Z
A

D(F4)/E(F5)
S

> >>

D-62

Contactors, Relays, Starters

Contactors
NC1-40Z~95Z

D(F4)/E(F5)

Model

A max

B max

C max

D max

E max

NC1-09(Z)~12(Z)

47

76

86(116)

120.5(154.5)

140.5(174.5)

34/35

50/60

4.5

60(95)

10.5

8.6

NC1-18(Z)

47

76

87(122)

125.5(160.5)

145.5(180.5)

34/35

50/60

4.5

61(96)

11.3

10.4

NC1-25(Z)

57

86

95(131)

133.5(169.5)

153.5(189.5)

40

48

4.5

70(107)

13.2

11.7

NC1-32(Z)

57

86

100(138)

138.5(176.5)

158.5(196.5)

40

48

4.5

71.6(120) 14.5

13

NC1-4011(Z)~6511(Z)

77

129

116(173)

154.5(211.5)

174.5(231.5)

40

105

6.5

78(135)

20

8.6

NC1-4004~6504

84

129

116

154.5

174.5

40

105

6.5

78(135)

20

8.6

NC1-4008~6508

84

129

127

154.5

174.5

40

105

6.5

78

20

8.6

NC1-8011(Z)~9511(Z)

87

129

127(188)

165.5(226.5)

185.5(246.5)

40

105

6.5

83(140)

23.5

12

NC1-8004~9504

96

129

122

160.5

180.5

40

105

6.5

83

23.5

12

NC1-8008~9508

96

129

135

160.5

180.5

40

105

6.5

83

23.5

12

Note:
1. L: in main circuit, the distance between terminals and plate;
2. P: in main circuit, the distance between two phases;
3. S: in main circuit, the width of contacting plate.