100% found this document useful (1 vote)
387 views2 pages

Brosur Total Station Sokkia CX105C

The document describes a construction total station called the CX-105C. It provides details on its technical specifications including its telescope, angle and distance measurement capabilities, interface and data management functions, onboard programs, accessories, and manufacturer.

Uploaded by

Dede Apit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
387 views2 pages

Brosur Total Station Sokkia CX105C

The document describes a construction total station called the CX-105C. It provides details on its technical specifications including its telescope, angle and distance measurement capabilities, interface and data management functions, onboard programs, accessories, and manufacturer.

Uploaded by

Dede Apit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CX-105C

Construction Total Station

Tradition Meets Innovation


n Advanced Angle Measurement System
*
n The Longest Battery Life - 36 Hours!
n Waterproof, Rugged, and Operator Friendly Design
* As of September, 2013.

+60C

CX-105C

SPECIFICATIONS

Construction Total Station

Model

CX-105C

Telescope
Magnification / Resolving power

30x / 2.5"

Others

Length: 171mm (6.7in.), Objective aperture: 45mm (1.8in.) (48mm (1.9in.) for EDM), Image: Erect,
Field of view: 130' (26m/1,000m),Minimum focus: 1.3m (4.3ft.), Reticle illumination: 5 brightness levels

Angle measurement
Display resolutions (selectable)

1" / 5"

Accuracy (ISO 17123-3:2001)

5"

Dual-axis compensator

Dual-axis liquid tilt sensor, working range: 6'

Distance measurement
Laser output *1

Class 1
*3/4

Measuring range
*2

(under average conditions )

Reflective sheet

RS90N-K: 1.3 to 500m (4.3 to 1,640ft.), RS50N-K: 1.3 to 300m (4.3 to 980ft.), RS10N-K: 1.3 to 100m (4.3 to 320ft.)

Mini prisms

CP01: 1.3 to 2,500m (8,200ft.), OR1PA: 1.3 to 500m (1,640ft.)

One AP prism

1.3 to 4,000m (4.3 to 13,120ft.) / Under good conditions : 5,000m (16,400ft.)

Three AP prism

to 5,000m (16,400ft.) / Under good conditions : to 6,000m (19,680ft.)

*5

*5

*2
Accuracy (ISO 17123-4:2001)

Reflective sheet

(3 + 2ppm x D) mm

(D=measuring distance in mm)

AP/CP prism

*3

(2 + 2ppm x D) mm

*6

Measuring time

Fine: 0.9s (initial 1.7s), Rapid: 0.7s (initial 1.4s), Tracking: 0.3s (initial 1.4s)

Interface and Data management


Data storage

Internal memory

Approx. 10,000 points

General
*7

Laser-pointer
Guide light

Coaxial red laser using EDM beam, Class 3R

*7

Levels

Green LED (524nm) and Red LED (626nm), Operating range: 1.3 to 150m (4.3 to 490ft.)
Graphic

6 (Inner Circle)

Circular level

10' / 2mm

Weight with battery & tribrach

Approx. 5.6kg (12.3 lb.)

Power supply
Battery

BDC70 detachable battery

Li-ion rechargeable battery

Operating time (20C)

BDC70

Approx. 36 hours (single distance measurement every 30 seconds)

*1 IEC60825-1:Ed.2.0:2007 / FDA CDRH 21 CFR Part 1040.10 and 11 *2 Average conditions: Slight haze, visibility about 20km (12 miles), sunny periods, weak scintillation. *3 When the measuring
beam's incidence angle is within 30 in relation to the reflective sheet target. *4 Measuring range in temperatures of 50 to 60C (122 to 140F): RS90N-K: 1.3 to 300m (4.3 to 980ft.), RS50N-K: 1.3
to 180m (4.3 to 590ft.), RS10N-K: 1.3 to 60m (4.3 to 190ft.) *5 Good conditions: No haze, visibility about 40km (25 miles), overcast, no scintillation. *6 Typical, under good conditions. Reflectorless
measurement time may vary according to measuring objects, observation situations and environmental conditions. *7 The laser-pointer and the guide light do not work simultaneously.

Onboard Programs Software

Standard Accessories

Topography, Resection, Setting-out, Setting-out arc, Setting-out line,


Single-distance offset, Two-distance offset, Angle offset, Plane offset,
Column offset, MLM, REM, Area calculation, Route surveying, Point to Line,
Intersections, Point projection, Traverse, Xsection

l CX main unit l Battery (BDC70) l Battery charger (CDC68) l Power Cable


l Lens cap l Lens hood l Tool pouch l Screwdriver l Lens brush l Adjusting pin x2
l Cleaning cloth l Operation manual l USB memory l Laser caution sign-board
l Carrying case l Carrying strap

TOPCON CORPORATION
75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
Phone: (+81)3-3558-2993 Fax: (+81)3-3960-4214
www.topcon.co.jp

<Contact to>
Sokkia Singapore Positioning Sales Pte. Ltd.
1 Jalan Kilang Timor, #09-01 Pacific Tech Centre, Singapore 159303
Phone: (+65)6479-3966 Fax : (+65)6479-4966
Email : [email protected]
Web : www.sokkia.com.sg/

Specifications subject to change without notice


2013 Topcon Corporation All rights reserved.

- Designs and specifications are subject to change without notice.


- Product colors in this brochure may vary slightly from those of the actual products owing to limitations of the printing process.

Your local Authorized Dealer is:

You might also like