Finite element analysis is useful numerical technique to solve various structural problems. In this paper FEA model of slab column connection is model using ANSYS 16.0 . Punching shear failure is a major problem encountered in the design of reinforced concrete flat plates. The utilization of shear reinforcement via shear studs or other means has become a choice for improving the punching shear capacity .The obtained results indicate that, the proposed shear reinforcement system and drop panel has a positive effect in the enhancement of both the punching shear capacity and the strain energy of interior slab–column connection of both normal and high strength concrete. The general finite element software ANSYS can be used successfully to simulate the punching shearbehaviour of reinforced concrete flat plates.
Finite element analysis is useful numerical technique to solve various structural problems. In this paper FEA model of slab column connection is model using ANSYS 16.0 . Punching shear failure is a major problem encountered in the design of reinforced concrete flat plates. The utilization of shear reinforcement via shear studs or other means has become a choice for improving the punching shear capacity .The obtained results indicate that, the proposed shear reinforcement system and drop panel has a positive effect in the enhancement of both the punching shear capacity and the strain energy of interior slab–column connection of both normal and high strength concrete. The general finite element software ANSYS can be used successfully to simulate the punching shearbehaviour of reinforced concrete flat plates.
ABSTRACT : Finite element analysis is useful numerical technique to solve various structural problems. In
this paper FEA model of slab column connection is model using ANSYS 16.0 . Punching shear failure is a major
problem encountered in the design of reinforced concrete flat plates. The utilization of shear reinforcement via
shear studs or other means has become a choice for improving the punching shear capacity .The obtained
results indicate that, the proposed shear reinforcement system and drop panel has a positive effect in the
enhancement of both the punching shear capacity and the strain energy of interior slabcolumn connection of
both normal and high strength concrete. The general finite element software ANSYS can be used successfully to
simulate the punching shearbehaviour of reinforced concrete flat plates.
KEYWORDS ANSYS, Drop Panel, Flat Slab, Punching.
I. Introduction
Punching shear is a critical design factor of reinforced concrete flat plates since it is associated with brittle
failure. Many alternative reinforcement systems had been introduced in literature; e.g., shear studs, bent bars, in
order to enhance the punching shear and the strain energy of slabcolumn connection. The punching shear
strength and deformation capacity are strongly influenced by the type and characteristics of the shear reinforcing
system. Flat slab is an ideal structural form for architects and contractors. Its flush soffit makes the formwork
construction, wiring and ducting work easy. Without using beams, flat slab provides more headroom or lower
storey height. It can thus allow for more storeys than other types of slab systems within the same building
height. But flat slab has inherent weaknesses. The connections between the floor slab and column in a flat slab
structure are generally the most critical part as far as the strength is concerned because it is a region where large
moments and shear forces are concentrated.
www.ijesi.org
49 | Page
Fig. 1
Fig 2
If more than one target surface will make contact with the same boundary of solid elements, you must define
several contact elements that share the same geometry but relate to separate targets (targets which have different
real constant numbers), or you must combine two target surfaces into one (targets that share the same real
constant numbers).
Fig 3
www.ijesi.org
50 | Page
Fig4
Fig 5
Fig 6
www.ijesi.org
51 | Page
Graph 1
The percentage error is found to be 20%. for non-linear results. For statics linear analysis analytical and
experimental results are nearly same. First crack in specimen is found at 150kN.The normal stress, shear stress,
shear strain, total deformation, and strain energy results for 150kN are shown in fig9,fig10.
Graph 2
Fig 7
www.ijesi.org
52 | Page
Fig. 8
Fig 9
Fig 10
www.ijesi.org
53 | Page
Ahmed Ibrahim, Salah E.E. El-Metwally, Hamed H. Asker,Mohamed A. El Zareef (2015).Effect of mid-thickness rebar mesh on
the behavior and punching shear strength of interior slabcolumn connection.HBRC Journal (2015).
ANSYS. ANSYS Users Manual Revision 16, ANSYS.
IS 1893-Part 1. Indian Standard Criteria for Earthquake Resistant Design of Structures, Bureau of Indian Standards, New Delhi,
India, 2002.
IS 456. Indian Standard Plain and Reinforced Concrete Code of Practice, Bureau of Indian Standards, New Delhi, India, 2000.
M. Priya, S. Greeshma and K. N. Suganya (2015), Finite Element Analysis of Slab - Column Joint Under Lateral Loading .Asian
Journal of Civil Engineering (BHRC) vol. 16, no. 2 (2015)
S.R. Hoseini Vaez, A. Kheyroddin, and H. Naderpour(2008),3D Finite Element Simulation of Slab-Column Connections
Strengthened with CFRP.Fourth International Conference on FRP Composites in Civil Engineering (CICE2008).
www.ijesi.org
54 | Page