63% found this document useful (19 votes)
49K views1 page

Atlas Copco Fault Codes

The document provides an instruction book that lists various fault codes, causes, and actions for a main motor converter alarm. It includes fault codes for overcurrent, ground fault, too high voltage, too low voltage, drive overload, converter overheating, hardware faults, motor overload, drive overload, over-torque detection, under-torque detection, over-speed, safe torque off, output phase loss, input phase loss, and communication error. It instructs the user to check voltages, wiring, fuses, temperatures, and contact Atlas Copco for additional troubleshooting assistance.

Uploaded by

Ahmed M. Elqutt
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
63% found this document useful (19 votes)
49K views1 page

Atlas Copco Fault Codes

The document provides an instruction book that lists various fault codes, causes, and actions for a main motor converter alarm. It includes fault codes for overcurrent, ground fault, too high voltage, too low voltage, drive overload, converter overheating, hardware faults, motor overload, drive overload, over-torque detection, under-torque detection, over-speed, safe torque off, output phase loss, input phase loss, and communication error. It instructs the user to check voltages, wiring, fuses, temperatures, and contact Atlas Copco for additional troubleshooting assistance.

Uploaded by

Ahmed M. Elqutt
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Instruction book

(1)

Main Motor Converter Alarm

(2)

Fault

Fault code

Cause

Actions

Overcurrent

Contact Atlas Copco

Ground fault

Contact Atlas Copco

Too high voltage. The voltage on the Check the supply voltage
converter is above the
Contact Atlas Copco.
specifications.

Too low voltage. The voltage on the Check the supply voltage
converter is below the
Contact Atlas Copco
specifications.
Power quality faults
Check for loose wiring/wiring errors
Check supply voltage during start up
Check fuses transformer (200V, 230V, 500V and
575V units only)

Drive overload

Contact Atlas Copco

Converter overheating (heat sink)

Check the ambient temperature


Check the cubicle cooling
Check airflow around drive
Check cooling fan and cooler contamination
Contact Atlas Copco

256

Hardware fault

Contact Atlas Copco

512

Motor overload

Contact Atlas Copco

Drive overload

Contact Atlas Copco

Over-torque detection

Contact Atlas Copco

Under-torque detection

Contact Atlas Copco

Over-speed

Contact Atlas Copco

Safe torque off

Check for loose wiring at inverter - Push emergency


stop button
Check temperature switch

Output phase loss

Contact Atlas Copco

Input phase loss

Check supply voltage


Check for loose wiring/wiring errors
Check supply voltage during start-up
Check fuses transformer (200V, 230V, 500V and
575V units only)

Communication error

Contact Atlas Copco

1024

8192

16384

104

2920 7110 00

You might also like