0% found this document useful (0 votes)
807 views

Radiation Safety Distance Diagram

This document provides a radiation safety distance diagram for Iridium 192, a radioactive source commonly used in radiation therapy. It includes a diagram showing safety distance circles around a radiation source/projector/camera center based on the source strength in Curies. A table then defines the radius in meters for each circle for both unshielded and tungsten collimated distances, ranging from 10 to 70 Curies source strength. The document was prepared by M. Jayaseelan to guide barricade distances needed during radiation therapy treatments based on the radioactive source strength.

Uploaded by

Eswaran
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
807 views

Radiation Safety Distance Diagram

This document provides a radiation safety distance diagram for Iridium 192, a radioactive source commonly used in radiation therapy. It includes a diagram showing safety distance circles around a radiation source/projector/camera center based on the source strength in Curies. A table then defines the radius in meters for each circle for both unshielded and tungsten collimated distances, ranging from 10 to 70 Curies source strength. The document was prepared by M. Jayaseelan to guide barricade distances needed during radiation therapy treatments based on the radioactive source strength.

Uploaded by

Eswaran
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

ADVANCE QUALITY SOLUTIONS PTE LTD

RADIATION SAFETY DISTANCE DIAGRAM

NOTE:
SOURCE

: IRIDIUM 192

RADIATION

: GAMMA RAY

CENTER

: SOURCE / PROJECTOR / CAMERA

CIRCLE IS THE BARRICADE DISTANCE NEED TO COVER WHILE DOING RT BASED ON THE SOURCE STRENGTH.
Prepared By
M. JAYASEELAN
Page 1 of 3

3
2
4

13

12
6

11
7

8
10
9

Page 2 of 3

Circle

Source Strength in Curies (Iridium 192)

Unshielded Distance in direction of


Beam

Tungsten Collimated Distance in direction of


Beam

( Radius of circle in Meter )

(Radius of circle in Meter)

13

70

216.00

33.23

12

65

208.20

32.00

11

60

200.00

30.77

10

55

191.50

29.46

50

182.50

28.07

45

173.20

26.65

40

163.30

25.10

35

152.75

23.50

30

141.40

21.75

25

129.00

19.85

20

115.50

17.76

15

100.00

15.53

10

81.65

12.56

Page 3 of 3