API 1104 _Reference block for PAUT
Note:
of
Diameter of Pipe: 40 inch
Nominal thickness (t):
31.75mm
Notch depth (N): 3.175 10%
notch depth
Notch minimum length from
edge (A): 50mm
Notch Width (B): 3.2mm Maximum
notch width
Minimum Length (C): 360mm +
(50mm) Minimum Length
Minimum width (D): 80mm
Minimum notch length (E): 25mm
R1: Outside radius of pipe
R2: Radius of inside notch = R1- 0.9 T
Scanning and evaluation:
Automated Ultrasonic Weld Testing:
API 1104 _Reference block for PAUT
Automated ultrasonic weld testing should be performed at a scanning sensitivity of
80 % screen height reference sensitivity plus 4 dB when using the pulse-echo
technique. Evaluation sensitivity should be the same as scanning sensitivity
Evaluation level screen height (recording threshold) should be 40 % of full screen
height using the automated pulse echo technique.
Other automated techniques, reference reflectors, reference sensitivities, scanning
sensitivities, evaluation sensitivities, and evaluation levels may be used if
demonstrated to be equivalent to the pulse-echo technique for the detection and
evaluation of weld imperfections.