100% found this document useful (4 votes)
2K views2 pages

API 1104 PAUT Cal Block

This document provides specifications for an API 1104 reference block for performing PAUT (Phased Array Ultrasonic Testing). It specifies the dimensions for a notch in the block including a diameter of 40 inch pipe, 31.75mm nominal thickness, 3.175mm ±10% notch depth, 50mm minimum length from edge, and 3.2mm maximum width. It also provides requirements for automated ultrasonic weld testing using the block, including scanning at a sensitivity of 80% screen height plus 4dB and an evaluation threshold of 40% of full screen height. Other techniques may be used if shown to be equivalent.

Uploaded by

WIZKHALIFA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (4 votes)
2K views2 pages

API 1104 PAUT Cal Block

This document provides specifications for an API 1104 reference block for performing PAUT (Phased Array Ultrasonic Testing). It specifies the dimensions for a notch in the block including a diameter of 40 inch pipe, 31.75mm nominal thickness, 3.175mm ±10% notch depth, 50mm minimum length from edge, and 3.2mm maximum width. It also provides requirements for automated ultrasonic weld testing using the block, including scanning at a sensitivity of 80% screen height plus 4dB and an evaluation threshold of 40% of full screen height. Other techniques may be used if shown to be equivalent.

Uploaded by

WIZKHALIFA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

API 1104 _Reference block for PAUT

Note:

of

Diameter of Pipe: 40 inch


Nominal thickness (t):
31.75mm
Notch depth (N): 3.175 10%
notch depth
Notch minimum length from
edge (A): 50mm
Notch Width (B): 3.2mm Maximum
notch width
Minimum Length (C): 360mm +

(50mm) Minimum Length


Minimum width (D): 80mm
Minimum notch length (E): 25mm
R1: Outside radius of pipe
R2: Radius of inside notch = R1- 0.9 T

Scanning and evaluation:


Automated Ultrasonic Weld Testing:

API 1104 _Reference block for PAUT


Automated ultrasonic weld testing should be performed at a scanning sensitivity of
80 % screen height reference sensitivity plus 4 dB when using the pulse-echo
technique. Evaluation sensitivity should be the same as scanning sensitivity
Evaluation level screen height (recording threshold) should be 40 % of full screen
height using the automated pulse echo technique.
Other automated techniques, reference reflectors, reference sensitivities, scanning
sensitivities, evaluation sensitivities, and evaluation levels may be used if
demonstrated to be equivalent to the pulse-echo technique for the detection and
evaluation of weld imperfections.