3D Model Formats and Files
3D Model Formats and Files
Intergraph
Products
CADWorx Plant
Professional,
CADWorx
Equipment
Notes/Requirements
2015
and
earlier
For .dwg files containing proxy objects, the following software is required:
.dwg
or
.drv
For CADWorx data, you must install the CADWorx Plant 2014
Object Enabler to view CADWorx Plant 2014 components
stored in an AutoCAD drawing (.dwg) file. You can install the
utility from the SmartPlant Interop Publisher DVD (Prerequisite
Software), or go to the Intergraph Smart Support website and
download this executable from CADWorx Freeware Tools and
Utilities.
CADWorx 2015 SP1 allows you to export .drv files that can be translated
to Smart Models for Smart 3D and SmartPlant Foundation target
applications.
SmartPlant Interop Publisher supports AutoCAD 2014 or earlier .dwg
files.
CAESAR II
5.1 2014
SP1
(7.0)
and
later
.mdb
Isogen (IDF,
PCF), SmartPlant
Spoolgen,
SmartPlant
Isometrics
2014
R1 and
earlier
PDS,
FrameWorks
Plus
V7
Smart 3D (3D
Model
2014
Graphics: .vue
R1 and Data: .xml
earlier
using
3D
Model
Data
Drawing
Intergraph
Products
Smart 3D
SPRDirect
Third Party
Products
Version
Source
Extension
ACIS - Design
ACIS R25 .sat
model data from
and earlier
products such as
AutoCAD
Inventor, Creo, JT
Open, Solid Edge,
and SolidWorks
AutoCAD
Notes/Requirements
2014 and
earlier
.dwg, .dxf
Notes/Requirements
Graphics only.
MicroStation V8i and RealDWG 2013 SP1 are required for DWG files
containing proxy objects.
AutoPlant
CATIA
.dwg, .dgn,
i.dgn
V5 (R8
R24) and
V6 (V6
R2014x).
.CATPart,
.CATProduct
MicroStation V8i SS3 and RealDWG 2013 SP1 are required for
AutoPLANT graphics files.
For CATIA V6, you must export your database objects as CATIA V5
CATParts and CATProducts.
You must have an MCD license and the Intergraph MCAD module
installed with SmartPlant Interop Publisher to translate MCAD source files.
You can set defeaturing options to reduce model complexity. For more
information, see Define Translation Settings (on page Error! Bookmark
not defined.) and Mechanical CAD (MCAD) defeaturing options (on page
Error! Bookmark not defined.).
CIS/2 (design
model data from
products such as
SDS/2, StruCAD,
Tekla Structures,
and ProSteel,
among others)
203, 214
.stp, .step
Where possible, we recommend using the IFC format for data exchange.
For more information on CIS/2 supported entities, see CIS/2 Entities and
Cross-Section Data.
.prt, .prt.*,
.asm, .asm.*
IGES (products
that export IGES)
.igs, .iges
5.3 and
earlier
You must have an MCD license and the Intergraph MCAD module
installed with SmartPlant Interop Publisher to translate MCAD source files.
You can set defeaturing options to reduce model complexity. For more
information, see Define Translation Settings (on page Error! Bookmark
not defined.) and Mechanical CAD (MCAD) defeaturing options (on page
Error! Bookmark not defined.).
The size of the file to be translated should not exceed 2 GB.
Graphics only.
Third Party
Products
Version
Source
Extension
i-model
MicroStati
on V8i
SS3 and
earlier
Industry
Foundation
Classes (IFC)
2x3_TC1
schema
version
Inventor
V11 2015
MicroStation J
V07.01.05. .dgn
03
Notes/Requirements
.i.dgn
.ifc
This is the recommended data exchange format for reading SDS/2, Tekla,
and Revit projects. SmartPlant Interop Publisher only supports IFC
2x3_TC1 schema.
V07.02.00.
00
(Required
for
supporting
Smart
Solids
display)
MicroStation V8:
V8.05
.dgn, .dtm
MicroStation XM
V8.09
.dgn, .dtm
MicroStation V8i
V8.11.09
.dgn, .dtm
NX
NX 1 - NX
9
.prt
You must have the Intergraph MCAD module and MCD license installed
with SmartPlant Interop Publisher to translate MCAD source files.
You can set defeaturing options to reduce model complexity. For more
information, see Define Translation Settings (on page Error! Bookmark
not defined.) and Mechanical CAD (MCAD) defeaturing options (on page
Error! Bookmark not defined.).
Parasolid
9.0 27.0
.x_t, .xmt_txt,
x_b, .xmt_bin
You must have an MCD license and the Intergraph MCAD module
installed with SmartPlant Interop Publisher to translate MCAD source files.
You can set defeaturing options to reduce model complexity. For more
information, see Define Translation Settings (on page Error! Bookmark
not defined.) and Mechanical CAD (MCAD) defeaturing options (on page
Error! Bookmark not defined.).
PlantSpace
V8.05,
.dgn
V8.09, and
V8.11.09
PlantSpace
AutoCAD
2014
.dwg
PDMS
V12.1 and
earlier
Graphics: .rvm
Data: .att/.datal
When there is an .att and .datal file, SmartPlant Interop Publisher uses
only the .att file. If the .rvm and .datal are used, not all objects can have
properties. You might have to go back to your PDMS application and
ensure that tags are written for all objects in the .datal file.
Third Party
Products
ProStructures
Solid Edge
Version
Source
Extension
v8i
SELECTs
eries 6
V18 - ST7
.par, .asm,
.psm
Notes/Requirements
You must have an MCD license and the Intergraph MCAD module
installed with SmartPlant Interop Publisher to translate MCAD source files.
You can set defeaturing options to reduce model complexity. For more
information, see Define Translation Settings (on page Error! Bookmark
not defined.) and Mechanical CAD (MCAD) defeaturing options (on page
Error! Bookmark not defined.).
SolidWorks
2003 2014
.sldprt, .sldasm
You must have an MCD license and the Intergraph MCAD module
installed with SmartPlant Interop Publisher to translate MCAD source files.
You can set defeaturing options to reduce model complexity. For more
information, see Define Translation Settings (on page Error! Bookmark
not defined.) and Mechanical CAD (MCAD) defeaturing options (on page
Error! Bookmark not defined.).
Speedikon, Tribon
M2 / M3
Tekla , StruCAD,
Xsteel, SDS/2,
Autodesk Revit,
RAM Steel,
ETABS,
SAP2000, RISA3D, Advance
Steel, GT
STRUDL,
STAAD.Pro,
ProSteel
XMpLant
IFC:
2x3_TC1
schema
version
MicroStation
.dgn
MicroStation V8i SS3 and RealDWG 2013 SP1 are required. MicroStation
v8i SS3 must be installed and activated.
For more information on CIS/2 supported entities, see CIS/2 Entities and
Cross-Section Data.
We recommend using the IFC format for data exchange.
To find the schema version of an .ifc file, open the file in any text editor
such as Windows Notepad, and check the FILE_SCHEMA version listed
in the File Header section. For IFC files that are supported by SmartPlant
Interop Publisher, the File Header has the FILE_SCHEMA(('IFC2X3'));
entry. For more information, see Translate IFC source files (on page
Error! Bookmark not defined.).
.xml
For ACIS and IGES files, the .drv and .mdb2 files generated by SmartPlant Interop Publisher during
translation are created with empty label data. This can also apply to MicroStation V7 .dgn files that do
not have tag data.
Both SmartPlant Review and Smart 3D target applications require licenses from Leica, Z+F or
Quantapoint to display laser data.
SmartPlant Interop Publisher does not support .dtm files created with Inroads.