Building Conditions Building Conditions: Progressive Collapse Story Number 4 Stories
Building Conditions Building Conditions: Progressive Collapse Story Number 4 Stories
Building Conditions
Progressive collapse
Story Number < 4 stories
Progressive collapse is not critical. However, the structure should be designed with minimum
vertical and horizontal ties and that all connections for beams and columns should be cast
monolithically. This is so the RC structure will have adequate reinforcement within to resist and
avoid progressive collapse.
For buildings with more than 4 stories, there should be adequate horizontal and vertical ties and
an alternative load path should also be designed. All connections should also be cast
monolithically.
Cladding
Brickwork or brick cladding No need to set back columns since there is no glazing
Perimeter fully glazed Columns and slabs should be set back 200mm to cater for cladding or glazing installations and
connections.
No external structural walls or columns should be allowed.
Steel truss at roof level
Yes Roller supports should be used to allow structural movement caused by thermal expansion
Torsional effect
YesTorsional effect is created by the asymmetric arrangement of core wall. Its effect on the structure
should be checked during detail design.
Structural Element to be Exposed
YesIn order to provide good appearance, fair face concrete or circular columns will be used and that
no false ceiling for slab soffit should be exposed. Fair face concrete or circular columns should
be constructed by using special material with high standards of construction care. There should
be no external cladding along the external perimeter walls.
NoThere is no need to set back edge columns
Plan Layout?
Open Plan LayoutOnly columns at 5m c/c should be used.
Lift pit should be considered by assuming its level to be 1.5m - 2m deep below.
Lift machine room should assumed to have a 4m height on roof level. The lift cores should be
used to resist lateral loading.
Lighting?
High degree of natural lightPerimeter should be glazed. Location of perimeter walls or columns should be considered for
light paths.
Artificial lighting usedThe structure can have perimeter walls or structural walls at the exterior enclosure.
Roof used as plant area with wall enclosed?
YesThe plant room should have lightweight waterproof as its exterior enclosure.
Core Wall Dimensions
YesCore dimensions is to be the external setting out dimension
Parapet Wall at Roof
YesParapet wall should be designed as 1400mm height
Heaving Effect Negligible
YesThis is because the basement or ground floor slab is on top of sand and gravel
Earthquake Load
YesEarthquake loads are not significant in Hong Kong
Elegant structure?
YesStructure should be light in weight, have small member sizes, and have good appearance
Swimming pool?
YesWaterproofing details should be shown, as well as construction approach.
Requires a Fast Construction Programme?
YesConstruction methods should be standardized and repetitive.
Flat slabs should be used in order to speed up construction.
Standardized formworks should be used to speed up construction.