Huawei MSOFTX3000 Table Size Increaseing.
Huawei MSOFTX3000 Table Size Increaseing.
Caution:
If any current step fails, do not proceed further.
Step 1
To format the database, execute the command FMT;
Step 2
To perform consistency check, execute the command STR
CRC: MN= XX;.
Note:
The parameter MN refers to the module number.
All the modules must go through consistency check.
Step 3
(1) To back up the BAM database, execute the command BKP
DB;
(2) Check the backup database for the following files:
Alarm2006XXXX.dat
Stats2006XXXX.dat
XSman2006XXXX.dat
Reg2006XXXX.dat
Stats2006XXXX.dat
Note:
If execution of the command FMT:; fails, do not proceed
further and turn to contact person for further assistance.
Step 5
Step 7
To stop backing up the WCCU/WCSU, execute the command
SET BAKMODE: MN=XX, SW=NOB;
(Set the BACKUP Mode to NOB for all the WCCU and
modules)
Step 8
(1)
(2)
108 increases to 8192 and for table ID 106 to 2048, execute the
following commands:
DSP TBL: MN=XX, TID="108", CMDTP=TBL;
XX= WCCU/WCSU Module number
DSP TBL: MN=XX, TID="106", CMDTP=TBL;
XX= WCCU/WCSU Module number
Step 10
Re-perform consistency check through the command STR CRC: MN=
XX; XX = is the all module number
Step 11
SET BAKMODE: MN=XX, SW=NMB;
XX= WCCU/WCSU Module number
If problems appear after you modify the maximum number of tuples, start
the procedure of back off in the following way:
(1) Log in to the client terminal of the CSOFTX3000.
(2) To change the maximum number of tuples for the CLDPREANA tabl
from 8192 to 4000 and Prefixpro table from 2048 to 1024, execute
the
command
MOD
MAXT:
TID=TID108,
LT=WCCU,
MAXN=4000;
MOD MAXT: TID=TID106, LT=WCCU, MAXN=1024;