Safety Matters - Performance Based Design Using Computer Fire Models

The document discusses the use of performance-based design and computer fire modeling to analyze fire safety and evacuation scenarios. It describes how fire models can be used to predict factors like fire growth, smoke spread, and structural impacts to determine adequate safety systems and code compliance. Examples are provided of projects where Aon Fire Protection Engineering utilized these techniques to analyze historic buildings, mixed-use developments, transit stations, airports, and allow the use of exposed structural steel. The overall benefit is a methodology to justify designs that enhance functionality while ensuring fire life safety.

Uploaded by

Basil Oguaka
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
61 views

Safety Matters - Performance Based Design Using Computer Fire Models

The document discusses the use of performance-based design and computer fire modeling to analyze fire safety and evacuation scenarios. It describes how fire models can be used to predict factors like fire growth, smoke spread, and structural impacts to determine adequate safety systems and code compliance. Examples are provided of projects where Aon Fire Protection Engineering utilized these techniques to analyze historic buildings, mixed-use developments, transit stations, airports, and allow the use of exposed structural steel. The overall benefit is a methodology to justify designs that enhance functionality while ensuring fire life safety.

Uploaded by

Basil Oguaka
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

12/14/2015

SafetyMattersPerformanceBasedDesignusingComputerFireModels

ThirdQuarter|2010

FEATUREARTICLE

TheEvolutionofaBrand:
WhySchirmer
EngineeringbecameAon
FireProtection
Engineering
FIREPROTECTION

PerformanceBased
DesignUsingComputer
FireModels
CODE

FormalCode
InterpretationBenefits
KeyClient
RISK

Solutionsfora
CombustibleDustHazard
LIFESAFETY

TheLifeSafetyPlanAn
EffectiveandValuable
Tool
SECURITY

TheMissingLink:Howto
Developa
ComprehensiveSecurity
Program
HISTORICALEVENTS

McGillCopperMine

FIREPROTECTION

PerformanceBasedDesignUsingComputerFireModels
ByJosephH.Talbert,PE,ARM,SeniorConsultant,AonFireProtectionEngineering

PerformancebasedDesign(PBD),asdefinedbytheSocietyofFireProtection
Engineers(SFPE),isanengineeringapproachtofireprotectiondesignbased
on(1)establishedfiresafetygoalsandobjectives(2)deterministicand
probabilisticanalysisoffirescenariosand(3)quantitativeassessmentof
designalternativesagainstthefiresafetygoalsandobjectivesusingaccepted
engineeringtools,methodologiesandperformancecriteria.
PBDtechniquesusingfiremodelshavebeeninuseforabout30to40years.
Theearliestmodelsweredevelopedinthe1970s.ModernPBDtechniques
utilizepowerfulcomputerfiremodelsusingcomputationalfluiddynamics(CFD)
softwaretopredictfireeffectsovertime.Anothermodelthatmaybeusedisa
timedexitanalysis(TEA)suchasEXITT,whichpredictstheamountoftime
requiredforoccupantstoexitabuilding.Whenappliedtogether,aTEAandCFD
analysiscancloselypredicttheamounttimeneededforabuildingsoccupants
tosafelyevacuatebeforetheeffectsofafire(smokeandheat)makeanexit
routeuntenable.
Touseoneofthesemodels,thefireprotectionengineerdevelopsafiregrowth
scenariothatisrepresentativeofafirethatcouldlikelyoccurinafacility,based
onthetypeofoccupancy,thefireloadingandthebuildinggeometry.These
modelsthenpredictsuchvariablesastemperaturesatvariouslocationsinthe
building,fireplumes,quantityofhotgases,andtheheightofthesmokelayer
predictedtooccurinthefacilitybeingevaluated.Byusingthisinformation,the
fireprotectionengineercanspecifytheappropriatetypeoffiredetectionand
suppressionsystemstomitigatethepredictedfireeffects.
AonFPEconductedfireprotectionandlifesafetyanalysesoftheGrandCentral

http://safetymatters.aonfpe.com/2010/3rdquarter/fireprotection.aspx

1/4

12/14/2015

SafetyMattersPerformanceBasedDesignusingComputerFireModels

SmelterFire
INSIDEAONFPE

AroundTheWorld:
ExpansionintheMiddle
East
MeetTheTeam:
WhytheNameChange?
AnInterviewwithMark
Rochholz,COO
LatestNews:
Learnaboutrecent
happeningsatAonFire
ProtectionEngineering
includingrecent
achievementsand
communityinvolvement
UpcomingEvents:
Findoutaboutupcoming
conferencesandevents
weareplanningtoattend
Careers:
Viewacurrentlistingof
careeropeningsinour
variousoffices
PROJECTSPOTLIGHT

HolshouserHallatthe
UniversityofNorth
CarolinaatCharlotte

TerminalbuildingsinNewYork.Theuniqueandhistoricnatureofthebuildings
meanttherewerevariousareasofnoncompliance,includingtraveldistance,
exitcapacityandexitenclosures.Evaluationofthemeansofegressincludeda
timedexitanalysisusingtheEXITTcomputermodel.Computerfiregrowth
modelingwasusedtoanalyzetheimpactoffiresinboththeTrainShedandthe
TerminalBuilding.Modelswereusedtoidentifyemergencysmokeventilation
capacitiesrequiredtomaintainsafeegressand,inconjunctionwithtimed
exitinganalyses,demonstratedsafeegressofpassengers.Throughthe
applicationofaperformancebasedapproach,includingriskassessment,timed
egressanalysisandcomputerfiremodelinganalysis,ourfireprotection
engineersdevelopedalternatemethodsofcodecomplianceaffordingbuilding
occupantsaleveloffireandlifesafetyconsistentwiththeintentofthecodes
whilepreservingthehistoricfeaturesofthecomplex.
ThePBDanalysismayallowthedesignertodesignmoreeffectivesmoke
controlsystemsandmayenablethedesignertoallowunprotectedopenings
thatwouldnotnormallybeallowedbyacodebetweenfloorsofbuildings.
108N.StateStreet,Chicago,IL(Block37)isamixedusehighrisestructure
thatincludesafourlevelshoppingpodiumthatanchorsthedevelopmentofthe
highriseofficetowerandhighriseresidentialtower.Theprojectincludesanew
subterraneantrainstationandparkinggaragefacilitythatwillbeblendedintothe
retailpodium.Anumberofcomplexlifesafetyissueswereposedbythe
integrationofthetrainstationintothemixedusestructure.AonFPEledthe
developmentoffireprotectionandlifesafetyconceptsforthedevelopment.
NFPA130,StandardforFixedGuideway&PassengerRailSystems,was
utilizedtodeveloptheegressconceptandsmokeevacuationconceptsforthe
undergroundareas.ExtensiveComputationalFluidDynamics(CFD)modeling
wasperformedtoevaluateanddeveloparchitecturalandmechanicalfeatures
neededforemergencysmokeevacuationofthetrainstation.
Anotheruseoffiremodelsistopredicttheheattransfertostructuralmembers
ofabuilding.Thistypeofanalysiscanresultinreducedfireresistanceratings
forstructuralmembers,whichcanbeasignificantbenefitindesign.
AonFireProtectionEngineering(AonFPE)servedastheprojectfireprotection
consultantfortheUnitedTerminalNo.1facilityatO'HareInternationalAirportin
Chicago,Illinois.Thefacilityconsistsoftwoterminalbuildingsconnectedbyan
undergroundpedestriantunnelandanundergroundautomatedbaggagehandling
complex.Primaryconsiderationsincludedachievingcodecomplianceand
adequateexitingforlargenumbersofpeople,specifyingprotectionsystem
featuresfortheconcourseareasandbaggagehandlingoperations,and
developingsolutionstoallowthesafeuseofanexposedstructuralsteelsystem
desiredbythearchitects.

http://safetymatters.aonfpe.com/2010/3rdquarter/fireprotection.aspx

2/4

12/14/2015

SafetyMattersPerformanceBasedDesignusingComputerFireModels

ThestringentChicagoBuildingCodeheightandarealimitationsrequiredthatthe
terminalbuildingsbeof3hourfireresistiveconstruction.Theproposeddesign
calledfortheuseofanarchitecturallyexposedstructuralsteelsystem.To
achievetheuseofthisproposedstructuralsystem,AonFPEpreparedan
extensiveanalysisandreportsubstantiatingtheuseofexposedstructuralsteel
forportionsofthebuilding.ThereportledtochangesintheCityofChicago
BuildingCodewhichallowedtheconstructionoftheUnitedAirlinesterminal,as
wellasotherstructuresplanningtouseexposedstructuralsteelsystemsin
Chicago.
TheoverallbenefitofaPBDapproachisthatitgivesthedesignera
methodologytojustifyabuildingdesignthatdoesnotmeetprescriptivecode
provisions,butthatenhancesthebuildingsfunctionalityandbeautywhilealso
enhancingtheoverallleveloffirelifesafetyprovidedtotheoccupants.
SharethisArticlewithfriends:

RatethisArticle:
Currentrating:0(0ratings)
Shareyourcomments:
Name:
Email:
YourwebsiteURL: http://

Comments:

SecurityCode:

Submit

CorporateHeadquarters*|4OverlookPoint|Lincolnshire,IL|60069|www.AonFPE.com
http://safetymatters.aonfpe.com/2010/3rdquarter/fireprotection.aspx

3/4

12/14/2015

SafetyMattersPerformanceBasedDesignusingComputerFireModels

*AonhasofficesconvenientlylocatedinmajorcitiesthoughouttheUnitedStatesandabroad.
VisitourwebsiteforacompletelistingoflocationsClickHere

<>

http://safetymatters.aonfpe.com/2010/3rdquarter/fireprotection.aspx

4/4

You might also like