Mikro Cat 2015

The document provides information on various types of relays and meters for electrical protection including overcurrent, earth fault, voltage, reverse power, power factor, and motor protection relays as well as annunciators and digital power meters. It lists models of each type of device and provides some key specifications. The document also contains reference colour tags and contact information for the company.

Uploaded by

Rahmat Nur Ilham
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
500 views74 pages

Mikro Cat 2015

The document provides information on various types of relays and meters for electrical protection including overcurrent, earth fault, voltage, reverse power, power factor, and motor protection relays as well as annunciators and digital power meters. It lists models of each type of device and provides some key specifications. The document also contains reference colour tags and contact information for the company.

Uploaded by

Rahmat Nur Ilham
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 74

reference colour tags

Combined Overcurrent &


Earth Fault Relay MK 2200L

MK 2200
MK 1000A

Overcurrent Relay
MK 233A
MK 234A
MK 203A
MK 204A

Earth Fault Relay


MK 231A
MK 232A
MK 201A
MK 202A

contents

Earth Leakage Relay


MK 300A / 300EA
MK 330A
MK 301A / 302A / 301E
DIN 330
DIN 310 / 310E
DIN 300 / 300E
ZCT 40S / 60S / 80S / 120S / 210S

Digital Power Meter


DVM
DAM
DPM 680
DPM 380 / 380B
DM 38

Voltage Relay
MU 350
MU 250 / 150
MU 2300
MX 210
MX 200A / 180A / 160A
MX 100 / 50

Reverse Power Relay


RPR 415A
RPR 415

Power Factor Regulator


PFR 140 / 120 / 80 / 60
PFR 96 / 96P
PFR LCD

Annunciator
AN 112 / 120 / 128
AL 24

Motor Protection Relay


MPR 500

Print Edition
Nov 2014
( 423468-T )
No.1 Jalan TP 7/7, Sime UEP Industrial Park,
40400 Shah Alam, Selangor, Malaysia.
Website: www.itmikro.com
Tel: +60-3-5192-7155
Fax: +60-3-5192-7166
Mikro reserves the right to make changes without further notice
to any products herein to improve reliability, function or design.
The figures shown are without obligation.

Features
Multifunction numerical relay
Three-phase, three stages setting for phase
overcurrent
Two stages setting for earth fault
IDMT and definite time
Thermal overload protection
Two groups of protection settings
Trip circuit supervision
Circuit breaker failure protection
RS232 and RS485 MODBUS-RTU communication
Fault, alarm and tripping records with timestamp
Multifunction programmable outputs
Multifunction digital inputs
Complies with IEC 60255-26 standard
ANSI code : 49RMS, 50P, 50G, 51P, 51G,

CLP, 50BF, 74TC

Combined Overcurrent & Earth Fault Relay

MK2200L

Technical Data
RATINGS

RECORDS

Auxiliary Supply

Model MK2200L-150D
Rated voltage
: 30 ~ 120 V DC
Operating voltage : 24 ~ 150 V DC
Model MK2200L-240AD
Rated voltage
: 100 ~ 240 V AC or

140 ~ 340 V DC
Operating voltage : 85 ~ 265 V AC or

110 ~ 370 V DC
Rated frequency : 50 or 60 Hz
Operating frequency : 45 ~ 65 Hz
Power consumption : 8 VA max

Current Inputs

Rated current, In, Ion : 1 or 5 A by connection


Frequency
: 50 or 60 Hz nominal
Burden
: < 0.025 VA (1 A)

: < 0.3 VA (5 A)
Thermal withstand : 4 x In continuous

: 40 x In for 2s

: 100 x In for 1s
Input type
Rated voltage

Output Contacts

: Optically isolated
: 20 ~ 380 V DC
: 50 ~ 270 V AC

Trip Contact Relay R1, R2, R3, R4, IRF Relay


Rated voltage : 250 V AC / DC
Continuous carry : 5 A
Expected electrical life : 100,000 operations at
rated load
Expected mechanical life : 5 x 106 operations

: Up to 50 records
: Up to 250 records
: Up to 30 records

SETTING RANGES
General

Line CT primary
Earth CT primary
Frequency

: 1 to 10,000 A
: 1 to 10,000 A
: 50 or 60 Hz

Phase Overcurrent
I>

: 0.1 to 25 x In (Recommended up to
2 x In for IDMT delay)
I> Delay type : IDMT or definite time
tI>
: 0 to 100 s
I> IDMT curve : NI, VI, EI, LTI, NI 1.3/10
ktI
: 0.01 to 1.00
I>>
: 0.5 to 40 x In
tI>>
: 0 to 100 s
I>>>
: 0.5 to 40 x In
I>>> Sample : Yes or No
tI>>>
: 0 to 100 s

Earth Fault
Io>

: 0.02 to 2 x Ion (Recommended up


to 0.5 x Ion for IDMT delay)
Io> Delay type : IDMT or definite time
tIo>
: 0 to 100 s
Io> IDMT curve : NI, VI, EI, LTI, NI 1.3/10
ktIo
: 0.01 to 1.00
Io>>
: 0.1 to 10 x Ion
tIo>>
: 0 to 100 s

Thermal Overload
Iq >
Tq
k
q Trip
q Alarm

: 0.1 to 3 x In
: 1 to 200 minutes
: 1 to 1.5
: 50 to 200%
: 50 to 200%

MEASUREMENT RANGES

Phase Current Secondary:


5 A input : 0 to 200 A
1 A input : 0 to 40 A
Earth Current Secondary:
5 A input : 0 to 50 A
1 A input : 0 to 10 A

ENVIRONMENTAL CONDITIONS

Temperature : -5C to 55C


Humidity : 56 days at 93% RH and 40C
non-condensing

MECHANICAL

Mounting
Dimension (mm)
Enclosure protection
Approximate weight

: Panel mounting
: 142(w) x 165(h) x 198(d)
: IP54 at the panel
: 2.9 kg

MK 2200L

Digital Inputs

Fault Record
Event Record
Alarm Record

Combined Overcurrent & Earth Fault Relay

Normal Inverse

Very Inverse

Extremely Inverse

Typical Application Diagram 1

Long Time Inverse

Case Dimensions
198 mm
34 mm

136 mm

Typical Application Diagram 2

165 mm

142 mm

Front

Side

MK 2200L

139 1 mm

129 1 mm

Panel Cutout

Ordering Information
MODEL

DESCRIPTION

MK2200L - 150D
MK2200L - 240AD

For 50/60 Hz, auxiliary voltage 24 ~ 150 V DC


For 50/60 Hz, auxiliary voltage 85 ~ 265 V AC
or 110 ~ 370 V DC

Features
Multifunction numerical relay
Three-phase, low-set and high-set phase overcurrent
Two sets of low-set and high-set setting for phase
overcurrent
Low-set and high-set earth fault
Two sets of low-set and high-set setting for earth fault
Circuit breaker failure protection
Four selectable IDMT characteristic curves
Definite time for low-set and high-set
Numeric display of phase and earth fault currents
Display of relay settings
9 non- volatile records of previous tripping currents
Recording of relay start time
Highly flexible programmable relay outputs
Multifunction external digital input
Isolated RS485 Modbus - RTU communication
Selectable 50 Hz / 60 Hz

Combined Overcurrent & Earth Fault Relay

MK2200

ANSI code : 50P, 50G, 51P, 51G, 50BF

Technical Data
ACCURACY

INPUTS
Measuring input:

Rated current In : 1 A or 5 A
Rated frequency : 50 or 60 Hz
Thermal withstand : 4 x In continuous

25 x In for less than 10 sec

100 x In for less than 1 sec
Burden
: < 0.3VA at In

Rated auxiliary voltage:


Model MK2200-150D
Model MK2200-240A
Model MK2200-240AD

Power consumption:
AC auxiliary voltage
DC auxiliary voltage

Binary Input:

External binary input


: 24~150 V DC
: 198~265 V AC
: 85~265 V AC
110~340 V DC
: 6 ~ 10 VA typical
: 5 ~ 9 W typical
: 18 ~ 265 V DC
85 ~ 265 V AC

Rated voltage : 250 V AC / DC


Continuous carry : 5 A

Contact specification:
Expected electrical life

: 100,000 operations
at rated current
Expected mechanical life : 5 x 106 operations

EARTH-FAULT ELEMENT
Low-set setting I o>

: 0.05 ~ 1.0 x In ,
step 0.01

High-set setting I o>>

: 0.05 ~ 10.0 x In ,
step 0.05

Time multiplier kt o>

: 0.02 ~ 1.0 ,
step 0.01

Low set definite time t o>, 0 ~ 300 s :



0 ~ 10.0s : step 0.01

10.0 ~ 100s : step 0.1

100 ~ 300s : step 1
High set definite time t o>>, 0 ~ 300 s :

0 ~ 10.0s : step 0.01

10.0 ~ 100s : step 0.1

100 ~ 300s : step 1

Time multiplier kt >

Low-set setting I >

: 0.10 ~ 2.50 x In ,
step 0.01

High-set setting I >> : 0.10 ~ 40 x In ,


0.1 ~ 10 In : step 0.05
10 ~ 40 In : step 0.1

Low set definite time t >, 0 ~ 300 s :



0 ~ 10.0s : step 0.01

10.0 ~ 100s : step 0.1

100 ~ 300s : step 1
High set definite time t >>, 0 ~ 300 s :

0 ~ 10.0s : step 0.01

10.0 ~ 100s : step 0.1

100 ~ 300s : step 1

ENVIRONMENTAL CONDITIONS

Temperature : -5C to +55C


Humidity
: 56 days at 93% RH and 40C

non-condensing

MECHANICAL

Mounting
Dimension (mm)
Enclosure protection
Approximate weight

COMMUNICATION
RS485 Modbus - RTU

OVERCURRENT ELEMENT

: 0.02 ~ 1.0 ,
step 0.01

: Panel mounting
: 142(w) x 165(h) x 198(d)
: IP54 at the panel
: 2.9 kg

MK 2200

OUTPUT CONTACTS
5 programmable contacts +1 IRF contact:

Protection thresholds : 3%
Time delay
: 2% with a minimum
of 30 ms
Measurements
: 3%
Reset ratio
: 95% typical
Overshoot time
: less than 30 ms typical

Combined Overcurrent & Earth Fault Relay

Normal Inverse

Very Inverse

t/s

t/s

Extremely Inverse
t/s
100

10
10
10

1.0
0.9
0.8
0.7
0.6
0.5
0.4

1.0
0.8
0.6
0.5
0.4
0.3

0.05

10

20

I/I >

0.1

0.1

0.05
0.05

0.01

10

20

0.01

I/I >

Typical Application Diagram 1


L1
L2
L3

1
2

COM
5A

LOAD

10

1A

Trip Contact
R1

4
5

COM
5A

38
37

R2

1A

7
8

COM
5A

40
39

R3

1A

42
41

R4

27
26

R5

13
14

28
30
29
22

Internal
Relay
Failure

32
33

23

Termination Resistor
RS485
N-

24

P+

31

25

Communication
Cable Shield

Case Dimensions
142 mm

198 mm
34 mm

1A

4
5

COM
5A

38
37

R2

1A

7
8

COM
5A

40
39

R3

1A

42
41

R4

27
26

R5

12 1 A

Auxiliary
input Uaux
LOAD

13
14

34
36
35

28
30
29
22

Trip Contact
R1

Internal
Relay
Failure

32
33

23

Termination Resistor
RS485
N-

24

P+

31

25

Communication
Cable Shield

136 mm

165 mm
COM
5A

Front

Side

129 1 mm

139 1 mm

MK 2200

1
2

10 COM
11 5 A

External
Binary
Input

I/I >

I/I >

Typical Application Diagram 2


L1
L2
L3
N

20

Long Time Inverse


34
36
35

12 1 A

Auxiliary
input Uaux

0.2

0.1

t/s

10 COM
11 5 A

External
Binary
Input

1.0
0.8
0.6
0.5
0.4
0.3

0.1

0.1

0.1

0.2

0.3
0.2

Panel Cutout

Ordering Information
MODEL

DESCRIPTION

MK2200 - 150D
MK2200 - 240A
MK2200 - 240AD

For 50/60 Hz system, auxiliary voltage 24 ~ 150 V DC


For 50/60 Hz system, auxiliary voltage 198 ~ 265 V AC
For 50/60 Hz system, auxiliary voltage 84 ~ 265 V AC
or 110 ~ 340 V DC

Features
Microprocessor based numerical relay
Current measurement based on fundamental
frequency
Three-phase, low-set overcurrent
Three-phase, high-set overcurrent
Low-set earth-fault
High-set earth-fault
Definite time for low-set and high-set
Five selectable IDMT characteristic curves
Local display of measured and set values
Programmable relay outputs
Non-volatile fault values recording
Complies with IEC 60255-26 standard
ANSI Code : 50P, 50G, 51P, 51G

Combined Overcurrent & Earth Fault Relay

MK1000A

Technical Data
RATINGS
Rated current ( In )
Rated frequency
Burden
Themal withstand

: 5A
: 50 or 60 Hz
: < 0.3 VA at In
: 4 x In continuous

AUXILIARY SUPPLY
Model MK1000A-240A(6) : 198 ~ 265 V AC
Model MK1000A-240AD(6) : 85 ~ 265 V AC
110 V DC ~ 340 V DC
Model MK1000A-150D(6) : 24 ~ 150 V DC
Supply frequency
: 50 or 60 Hz
V A rating
: 3 VA typical

ACCURACY
Protection thresholds
Time delay

: 5%
: 5% with a
minimum of 50 ms

Trip Contacts ( R1 & R2 )


Rated voltage
: 250V AC / DC
Contact rating
: 5A
Expected electrical life : 100,000 operations
at rated current
Expected mechanical life : 5 x 106 operations

Low-set ( I > )

: 0.5 A to 10.0 A,
step 0.05 A

: 10% to 200%,
step 1%
Low-set time multiplier ( kt >): 0.05 to 1.0,
step 0.01
Low-set definite time ( t > ) : 0.05 to 99s
High-set ( I >> )
: 0.5 A to 99.9 A,
step 0.10 A or
disable

: 10% to 1998%,
step 2%
High-set delay time ( t >> ) : 0.05 sec to 2.5 sec,
step 0.01

ii ) Earth-fault element
Low-set ( I o > )

: 0.10 A to 5.0 A,
step 0.05 A

: 2% to 100%
Low-set time multiplier(kt o>): 0.05 to 1.0,
step 0.01
Low-set definite time ( t o > ) : 0.05 to 99s
High-set ( I o >> )
: 0.10 A to 50 A,
step 0.10 A or
disable

: 2% to 1000%,
step 2%
High-set delay time ( t o >> ) : 0.05 sec to 2.5 sec,
step 0.01

INDICATORS
Auxiliary supply
Pick-up
Trip

: Green indicator
: Red indicator
: 7-segment display
and red indicators

ENVIRONMENTAL CONDITIONS
Temperature
Humidity

: -5C to +55C
: 56 days at 93% RH and 40C
non-condensing

MECHANICAL
Mounting
Dimension (mm)
Enclosure protection
Approximate weight

: Panel mounting
: 96(w) x 96(h) x 110(d)
: IP54 at the panel
: 0.8 kg

MK 1000A

OUTPUT CONTACTS

SETTING RANGES
i ) Overcurrent elements

Combined Overcurrent & Earth Fault Relay

Normal Inverse

Very Inverse

Long Time Inverse

Typical Application Diagram


Aux

N
NO

Extremely Inverse

NC COM COM NC
4

R1

Normal Inverse 1.3/10

10

11

12

13

MK1000A
NO

15

16

R2
14

L1
LOAD

L2
L3
N

Case Dimensions

96 mm

96 mm

Front

110 mm
100 mm

Ordering Information

Side

MK1000A-240A
MK1000A-240AD
MK1000A-150D
MK1000A-240AD6
MK1000A-150D6

For 50Hz system, auxiliary voltage 198 ~ 265 V AC


For 50Hz system, auxiliary voltage 85 ~ 265 V AC or 110~340 V DC
For 50Hz system, auxiliary voltage 24 ~ 150 V DC
For 60Hz system, auxiliary voltage 85 ~ 265 V AC or 110~340 V DC
For 60Hz system, auxiliary voltage 24 ~ 150 V DC

91.0 0.5 mm

Panel Cutout

91.0 0.5 mm

MK 1000A

MODEL DESCRIPTION

Features

Microprocessor based numerical relay

Overcurrent Relay

MK233A
Current measurement based on fundamental
frequency

Three-phase, low-set overcurrent


Three-phase, high-set overcurrent
Local display of measured and set values
Definite time for low-set and high-set
Non-volatile fault value recording
Programmable relay outputs
Five selectable IDMT characteristic curves
Complies with IEC 60255-26 standard
ANSI Code : 50P, 51P

Technical Data
RATINGS
Rated current ( In )
Rated frequency
Burden
Thermal withstand

:
:
:
:

5A
50 or 60 Hz
< 0.3 VA at In
4 x In continuous

AUXILIARY SUPPLY
Model MK233A-240A (6) : 198 ~ 265 V AC
Model MK233A-110A (6) : 94 ~ 127 V AC
Supply frequency
: 50 or 60 Hz
VA rating
: 3 VA typical

ACCURACY

INDICATORS

Protection thresholds : 5%
Time delay
: 5% with a minimum of
50 ms

Auxiliary supply
Pick-up
Trip

OUTPUT CONTACTS (R1 & R2)


Rated voltage
: 250 V AC / DC
Contact rating
: 5A
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life: 5 x 106 operations

SETTING RANGES

ENVIRONMENTAL CONDITIONS
Temperature : -5C to +55C
Humidity
: 56 days at 93% RH and 40C
non-condensing

MECHANICAL
Mounting
Dimension (mm)
Enclosure protection
Approximate weight

: Panel mounting
: 96(w) x 96(h) x 110(d)
: IP54 at the panel
: 0.8 kg

MK 233A

Low-set ( I > )
: 0.5 A to 6.0 A, step 0.05 A / 10% to 120%, step 1%
Low-set time multiplier ( kt > ) : 0.05 to 1.0, step 0.01
Low-set definite time (t >)
: 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.0 to 99)
High-set ( I >> )
: 0.5 A to 99.9 A or disable, step 0.10 A / 10% to 1998%, step 2%
High-set delay time ( t >> ) : 0.05 sec to 2.5 sec, step 0.01

: Green indicator
: Red indicator
: 7-segment display and
red indicators

Overcurrent Relay

Normal Inverse

Very Inverse

Long Time Inverse

Typical Application Diagram


Aux

N
NO

Extremely Inverse

NC COM COM NC
4

5
R1

Normal Inverse 1.3/10

10

11

12

13

MK 233A
NO

15

16

R2
14

L1
LOAD

L2
L3
N

Case Dimensions

96 mm

96 mm

Front

110 mm
100 mm

Ordering Information

Side

MK233A - 240A
MK233A - 110A
MK233A - 240A6
MK233A -110A6

For 50 Hz system, auxiliary voltage198 ~ 265 V AC


For 50 Hz system, auxiliary voltage 94 ~ 127 V AC
For 60 Hz system, auxiliary voltage198 ~ 265 V AC
For 60 Hz system, auxiliary voltage 94 ~ 127 V AC

91.0 0.5 mm

Panel Cutout

91.0 0.5 mm

MK 233A

MODEL DESCRIPTION

Overcurrent Relay

MK234A
Features
Microprocessor based numerical relay
Current measurement based on fundamental
frequency
Three-phase, low-set overcurrent
Three-phase, high-set overcurrent
Local display of measured and set values

Definite time for low-set and high-set


Non-volatile fault value recording
Programmable relay outputs
Complies with IEC 60255-26 standard
ANSI : 50P, 51P

Technical Data
RATINGS
Rated current ( In )
Rated frequency
Burden
Thermal withstand

ACCURACY
:
:
:
:

5A
50 or 60 Hz
< 0.3 VA at In
4 x In continuous

Protection thresholds
Time delay

INDICATORS
: 5%
: 5% with a minimum
of 50 ms

OUTPUT CONTACTS (R1 & R2)

AUXILIARY SUPPLY
Model MK234A-240A (6) : 198 ~ 265 V AC
Model MK234A-110A (6) : 94 ~ 127 V AC
Supply frequency
: 50 or 60 Hz
VA rating
: 3 VA typical

Rated voltage
Contact rating
Expected electrical life

: 250 V AC / DC
: 5A
: 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

: Green indicator
: Red indicator
: 7-segment display
and red indicators

ENVIRONMENTAL CONDITIONS
Temperature : -5C to +55C
Humidity
: 56 days at 93% RH and 40C
non-condensing

MECHANICAL

SETTING RANGES
: 0.5 A to 6.0 A, step 0.05 A / 10% to 120%, step 1%
: 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.0 to 99)
: 0.5 A to 99.9 A or disable, step 0.10 A / 10% to 1998%, step 2%
: 0.05 sec to 2.5 sec, step 0.01

Mounting
Dimension (mm)
Enclosure protection
Approximate weight

: Panel mounting
: 96(w) x 96(h) x 110(d)
: IP54 at the panel
: 0.8 kg

MK 234A

Low-set ( I > )
Low-set definite time ( t > )
High-set ( I >> )
High-set delay time ( t >> )

Auxiliary supply
Pick-up
Trip

96 mm

Aux

N
NO

Case Dimensions

NC COM COM NC
4

5
R1

10

11

12

13

MK 234A
NO

15

16

96 mm

Overcurrent Relay

Typical Application Diagram

Front

R2
14

110 mm
100 mm

L1
LOAD

L2
L3

Side

Panel Cutout

Ordering Information
MODEL DESCRIPTION
MK234A - 240A
MK234A - 110A
MK234A - 240A6
MK234A -110A6

For 50 Hz system, auxiliary supply 198 ~ 265 V AC


For 50 Hz system, auxiliary supply 94 ~ 127 V AC
For 60 Hz system, auxiliary supply 198 ~ 265 V AC
For 60 Hz system, auxiliary supply 94 ~ 127 V AC

91.0 0.5 mm

91.0 0.5 mm

MK 234A

Features
Microprocessor based numerical relay

Overcurrent Relay

MK203A
Current measurement based on fundamental
frequency

Low-set inverse definite minimum time ( IDMT )


relay

High-set instantaneous relay


Separate low-set and high-set trip indicators
Option to disable high-set relay
Front panel access to test function
Complies with IEC 60255-26 standard
ANSI Code : 50P, 51P

Technical Data
RATINGS
Rated current ( In )
Rated frequency
Burden
Thermal withstand

: 5 A
: 50 Hz
: < 0.3 VA at In
: 4 x In continuous

AUXILIARY SUPPLY
Model MK203A-240A : 198 ~ 265 V AC
Model MK203A-110A : 94 ~ 127V AC
Supply frequency : 50 Hz
VA rating
: 3 VA typical

SETTING RANGES
Low-set ( I > )
: 2.0 A to 6.0 A

: 40% to 120%
Time multiplier ( TM ) : 0.05 to 1.0
High-set ( I >> )
: I > to 10 x I > or disable
High-set delay time (t >>) : Instantaneous

ENVIRONMENTAL CONDITIONS
Temperature
Humidity

MECHANICAL
Mounting
: Panel mounting
Dimension (mm)
: 96(w) x 96(h) x 110(d)
Approximate weight : 0.8 kg

INDICATORS
Auxiliary supply
Pick-up
Trip

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

: Green indicator
: Red indicator
: Red indicator

ACCURACY
Protection thresholds : 5%
Time delay
: 5% with a minimum
of 50 ms

MK 203A

TIME CURRENT CHARACTERISTIC CURVE


- Normal Inverse

OUTPUT CONTACTS
Trip contact (R1)
: Manual reset type
Rated voltage
: 250 V AC
Contact rating
: 5A
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life: 5 x 106 operations

Aux

N
2

AUX

MK 203A
NO

Combined IDMT Overcurrent & Earth Fault Relays

NC COM
4

N
NO

10

11

12

13

AUX

14

15

16

10

11

12

MK 202A
NO

NC COM

14

15

16

10

11

12

13

L1
LOAD

L2
L3

L2
L3

Normal Inverse

Case Dimensions

96 mm

96 mm

Front

110 mm
100 mm

Side

Panel Cutout

MK 203A

MODEL DESCRIPTION
For 50 Hz system, auxiliary voltage 198 ~ 265 V AC
For 50 Hz system, auxiliary voltage 94 ~ 127 V AC

91.0 0.5 mm

91.0 0.5 mm

Ordering Information

14

15

16

R1

R1

L1

MK203A - 240A
MK203A - 110A

NC COM

R1
9

MK 203A

LOAD

Overcurrent Relay

Typical Application Diagram

13

Features
Microprocessor based numerical relay

Overcurrent Relay

MK204A
Current measurement based on fundamental
frequency

Low-set inverse definite time relay (IDT)


High-set instantaneous relay
Separate low-set and high-set trip indicators
Option to disable high-set relay
Front panel access to test function
Complies with IEC 60255-26 standard
ANSI Code : 50P, 51P

Technical Data
RATINGS
Rated current ( In )
Rated frequency
Burden
Thermal withstand

: 5 A
: 50 Hz
: < 0.3 VA at In
: 4 x In continuous

AUXILIARY SUPPLY
Model MK204A-240A : 198 ~ 265 V AC
Model MK204A-110A : 94 ~ 127V AC
Supply frequency : 50 Hz
VA rating
: 3 VA typical

OUTPUT CONTACTS

ENVIRONMENTAL CONDITIONS

Trip contact (R1)


: Manual reset type
Rated voltage
: 250 V AC
Contact rating
: 5A
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life: 5 x 106 operations

Temperature
Humidity

MECHANICAL
Mounting
: Panel mounting
Dimension (mm)
: 96(w) x 96(h) x 110(d)
Approximate weight : 0.8 kg

INDICATORS
Auxiliary supply
Pick-up
Trip

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

: Green indicator
: Red indicator
: Red indicator

ACCURACY
Protection thresholds : 5%
Time delay
: 5% with a minimum
of 50 ms

MK 204A

SETTING RANGES
Low-set ( I > )
: 2.0 A to 6.0 A

: 40% to 120%
Time multiplier ( TM ) : 0.05 to 1.0
High-set ( I >> )
: I > to 10 x I > or disable
High-set delay time (t >>) : Instantaneous

Aux

N
2

AUX

MK 204A
NO

Combined IDMT Overcurrent & Earth Fault Relays

NC COM
4

N
NO

10

11

12

13

AUX

14

15

16

10

11

12

NC COM

13

14

15

16

10

11

12

LOAD

L3

L2
L3

Inverse Definite Time

Case Dimensions
96 mm

96 mm

t/s
Front

10
110 mm
100 mm

k
1.0
0.9
0.8
0.7
0.6
0.5
0.4

0.3

Side

91.0 0.5 mm

0.1
10

20

I/I>

Ordering Information

MK 204A

MODEL DESCRIPTION
For 50 Hz system, auxiliary voltage 198 ~ 265 V AC
For 50 Hz system, auxiliary voltage 94 ~ 127 V AC

Panel Cutout

91.0 0.5 mm

0.2

0.1

14

15

16

R1

L1

L2

MK204A - 240A
MK204A - 110A

MK 201A
NO

R1

L1

NC COM

R1
9

MK 204A

LOAD

Overcurrent Relay

Typical Application Diagram

13

Earth Fault Relay

MK231A
Features
Microprocessor based numerical relay
Current measurement based on fundamental
frequency

Low-set earth-fault
High-set earth-fault
Local display of measured and set values
Definite time for low-set and high-set
Non-volatile fault value recording
Programmable relay outputs
Complies with IEC 60255-26 standard
ANSI Code : 50N, 51N

Technical Data
RATINGS
Rated current ( In )
Rated frequency
Burden
Thermal withstand

ACCURACY
:
:
:
:

5A
50 or 60 Hz
< 0.3 VA at In
4 x In continuous

Protection thresholds
Time delay

AUXILIARY SUPPLY

OUTPUT CONTACTS

Model MK231A-240A (6) : 198 ~ 265 V AC


Model MK231A-110A (6) : 94 ~ 127 V AC
Supply frequency
: 50 or 60 Hz
VA rating
: 3 VA typical

Rated voltage
Contact rating
Expected electrical life

INDICATORS
: 5%
: 5% with a minimum
of 50 ms

: 250 V AC / DC
: 5A
: 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

SETTING RANGES
Low-set ( I > )
Low-set definite time ( t > )
High-set ( I >> )
High-set delay time ( t >> )

: 0.1 A to 5.0 A, step 0.05 A / 2% to 100%, step 1%


: 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.0 to 99)
: 0.1 A to 50 A or disable, step 0.1 A / 2% to 1000%, step 2%
: 0.05 sec to 2.5 sec, step 0.01

Auxiliary supply
Pick-up
Trip

: Green indicator
: Red indicator
: 7-segment display
and red indicators

ENVIRONMENTAL CONDITIONS
Temperature : -5C to +55C
Humidity
: 56 days at 93% RH and 40C
non-condensing

MECHANICAL
Mounting
Dimension (mm)
Enclosure protection
Approximate weight

: Panel mounting
: 96(w) x 96(h) x 110(d)
: IP54 at the panel
: 0.7 kg

MK 231A

Earth Fault Relay

Typical Application Diagram 1


Aux

N
NO

MK 231A
NC COM COM NC NO
4

5
R1

10

11

Typical Application Diagram 2

12

13

Aux

N
NO

NC COM COM NC
4

R2
14

5
R1

15

16

L1
LOAD

L2
L3
N

10

11

12

13

MK 231A
NO

15

16

R2
14

L1
L2
L3
N
Core Balance
Current Transformer

Ordering Information

Case Dimensions

96 mm

96 mm

MODEL DESCRIPTION
MK231A - 240A
MK231A - 110A
MK231A - 240A6
MK231A -110A6

Front

110 mm
100 mm

Side

Panel Cutout

91.0 0.5 mm

91.0 0.5 mm

For 50 Hz system, auxiliary voltage 198 ~ 265 V AC


For 50 Hz system, auxiliary voltage 94 ~ 127 V AC
For 60 Hz system, auxiliary voltage 198 ~ 265 V AC
For 60 Hz system, auxiliary voltage 94 ~ 127 V AC

MK 231A

Earth Fault Relay

MK232A
Features
Microprocessor based numerical relay
Current measurement based on fundamental
frequency

Low-set earth-fault
High-set earth-fault





Local display of measured and set values


Definite time for low-set and high-set
Non-volatile fault value recording
Programmable relay outputs
Five selectable IDMT characteristic curves
Complies with IEC 60255-26 standard

ANSI Code : 50N, 51N

Technical Data
RATINGS

Rated current ( In )
Rated frequency
Burden
Thermal withstand

:
:
:
:

ACCURACY

Protection thresholds
Time delay

5A
50 or 60 Hz
< 0.3 VA at In
4 x In continuous

: 250 V AC / DC
: 5A
: 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

Low-set ( I > )
Low-set time multiplier ( kt > )
Low-set definite time (t >)
High-set ( I >> )
High-set delay time ( t >> )

MK 232A
NC COM COM NC NO
4

10

11

12

13

N
NO
2

NC COM COM NC
4

14

5
R1

15

16

LOAD

L3

Aux

R2

L1
L2

Typical Application Diagram 2

: Panel mounting
: 96(w) x 96(h) x 110(d)
: IP54 at the panel
: 0.7 kg

10

11

12

13

MK 232A
NO

15

16

R2
14

L1
L2
L3
N
Core Balance
Current Transformer

MK 232A

R1

Mounting
Dimension (mm)
Enclosure protection
Approximate weight

: 0.1 A to 5.0 A, step 0.05 A / 2% to 100%, step 1%


: 0.05 to 1.0, step 0.01
: 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.0 to 99)
: 0.1 A to 50 A or disable, step 0.1 A / 2% to 1000%, step 2%
: 0.05 sec to 2.5 sec, step 0.01

Typical Application Diagram 1


NO

Temperature : -5C to +55C


Humidity
: 56 days at 93% RH and 40C
non-condensing

MECHANICAL

SETTING RANGES

: Green indicator
: Red indicator
: 7-segment display
and red indicators

ENVIRONMENTAL CONDITIONS

Rated voltage
Contact rating
Expected electrical life

Model MK232A-240A (6) : 198 ~ 265 V AC


Model MK232A-110A (6) : 94 ~ 127 V AC
Supply frequency
: 50 or 60 Hz
VA rating
: 3 VA typical

Aux

Auxiliary supply
Pick-up
Trip

OUTPUT CONTACTS

AUXILIARY SUPPLY

INDICATORS

: 5%
: 5% with a minimum
of 50 ms

Earth Fault Relay

Normal Inverse

Very Inverse

Long Time Inverse

Extremely Inverse

Normal Inverse 1.3/10

Case Dimensions

96 mm

96 mm

Front

110 mm
100 mm

Side

Panel Cutout

Ordering Information

MK 232A

MODEL DESCRIPTION
MK232A - 240A
MK232A - 110A
MK232A - 240A6
MK232A -110A6

For 50 Hz system, auxiliary voltage 198 ~ 265 V AC


For 50 Hz system, auxiliary voltage 94 ~ 127 V AC
For 60 Hz system, auxiliary voltage 198 ~ 265 V AC
For 60 Hz system, auxiliary voltage 94 ~ 127 V AC

91.0 0.5 mm

91.0 0.5 mm

Earth Fault Relay

MK201A
Features
Microprocessor based numerical relay
Current measurement based on fundamental
frequency

Low-set definite time relay


High-set instantaneous relay
Separate low-set and high-set indicators
Option to disable the high-set relay
Front panel access to the test function
Complies with IEC 60255-26 standard
ANSI Code : 50N, 51N

Technical Data
ACCURACY

RATINGS
Rated current ( In )
Rated frequency
Burden
Thermal withstand

: 5 A
: 50 Hz
: < 0.3 VA at In
: 4 x In continuous

AUXILIARY SUPPLY
Model MK201A-240A : 198 ~ 265 V AC
Model MK201A-110A : 94 ~ 127 V AC
Supply frequency
: 50 Hz
VA rating
: 3 VA typical

SETTING RANGES
Low-set ( I > )
: 0.1 A to 2.0 A

: 2% to 40%
Low-set delay time(DELAY): 0.05 sec to 1.0 sec
High-set ( I >> )
: I > to 10 x I > or disable
High-set delay time ( t >> ) : Instantaneous

Protection thresholds
Time delay

INDICATORS
: 5%
: 5% with a minimum
of 50 ms

Auxiliary supply
Pick-up
Trip

: Green indicator
: Red indicator
: Red indicator

OUTPUT CONTACTS

ENVIRONMENTAL CONDITIONS

Trip contact (R1)


Rated voltage
Contact rating
Expected electrical life

Temperature : -5C to +55C


Humidity
: 56 days at 93% RH and 40C
non-condensing

: Manual reset type


: 250 V AC
: 5A
: 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

MECHANICAL
Mounting
: Panel mounting
Dimension (mm)
: 96(w) x 96(h) x 90(d)
Approximate weight : 0.6 kg

MK 201A

Aux

N
2

AUX

MK 201A
NO

Combined IDMT Overcurrent & Earth Fault Relays

NC COM
4

N
NO

10

11

12

13

14

15

16

10

11

12

MK 201A
NO

NC COM

13

14

15

16

10

11

12

LOAD

L3

L2
L3

Case Dimensions
90 mm
70 mm

Front

Side

Ordering Information
MODEL DESCRIPTION
For 50 Hz system, auxiliary voltage 198 ~ 265 V AC
For 50 Hz system, auxiliary voltage 94 ~ 127 V AC

91.0 0.5 mm

Panel Cutout

91.0 0.5 mm

96 mm

14

15

16

R1

L1

L2

96 mm

R1

L1

MK201A - 240A
MK201A - 110A

AUX

NC COM

R1
9

MK 204A

LOAD

Earth Fault Relay

Typical Application Diagram

13

MK 201A

Earth Fault Relay

MK202A
Features
Microprocessor based numerical relay
Current measurement based on fundamental
frequency

Low-set inverse definite minimum time ( IDMT )


relay

High-set instantaneous relay


Separate low-set and high-set trip indicators
Option to disable high-set element
Front panel access to test function
Complies with IEC 60255-26 standard
ANSI Code : 50N, 51N

Technical Data
ACCURACY

RATINGS
Rated current ( In )
Rated frequency
Burden
Thermal withstand

: 5 A
: 50 Hz
: < 0.3 VA at In
: 4 x In continuous

AUXILIARY SUPPLY
Model MK202A-240A
Model MK202A-110A
Supply frequency
VA rating

SETTING RANGES

: 198 ~ 265 V AC
: 94 ~ 127V AC
: 50 Hz
: 3 VA typical

Protection thresholds
Time delay

INDICATORS
: 5%
: 5% with a minimum
of 50 ms

Auxiliary supply
Pick-up
Trip

: Green indicator
: Red indicator
: Red indicator

OUTPUT CONTACTS

ENVIRONMENTAL CONDITIONS

Trip contact (R1)


Rated voltage
Contact rating
Expected electrical life

Temperature : -5C to +55C


Humidity
: 56 days at 93% RH and 40C
non-condensing

: Manual reset type


: 250 V AC
: 5A
: 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

MK 202A

TIME CURRENT CHARACTERISTIC CURVE


Low-set ( I > )
: 0.1A to 2.0 A
Normal Inverse

: 2% to 40%
Time multiplier ( TM )
: 0.05 to 1.0
High-set ( I >> )
: I > to 10 x I > or disable
High-set delay time (t >>) : Instantaneous

MECHANICAL
Mounting
: Panel mounting
Dimension (mm)
: 96(w) x 96(h) x 90(d)
Approximate weight : 0.6 kg

Aux

N
2

AUX

MK 202A
NO

Combined IDMT Overcurrent & Earth Fault Relays

NC COM
4

N
NO

10

11

12

13

AUX

14

15

16

10

11

12

MK 202A
NO

NC COM

14

15

16

10

11

12

13

L1
LOAD

L2
L3

L2
L3

Normal Inverse

Case Dimensions

96 mm

96 mm

Front

90 mm
70 mm

Side

Panel Cutout

MK 202A

MODEL DESCRIPTION
For 50 Hz system, auxiliary voltage 198 ~ 265 V AC
For 50 Hz system, auxiliary voltage 94 ~ 127 V AC

91.0 0.5 mm

91.0 0.5 mm

Ordering Information

14

15

16

R1

R1

L1

MK202A - 240A
MK202A - 110A

NC COM

R1
9

MK 203A

LOAD

Earth Fault Relay

Typical Application Diagram

13

Features for MK 300A / 300EA


Numerical earth leakage relay

Earth Leakage Relay

MK300A
MK300EA
Programmable current sensitivity and time delay

MK 300A

Detection of no connection to ZCT


Relay trip indicator
Relay alarm indicator
Real-time leakage current display
50% pre-fault indicator
Leakage fault current recording
Standard DIN 96x96mm panel mounting
Protected against nuisance tripping

Features for MK 300EA only


Positive safety output contact

MK 300EA

Pre-fault alarm contact


Remote reset function

Technical Data
AUXILIARY SUPPLY

Model MK300A / 300EA -230A


Model MK300A / 300EA -110A
Rated frequency
VA rating

: 184 ~ 276 V AC
: 94 ~ 127 V AC
: 50 Hz
: 3 VA typical

INPUT

Remote Reset

: N.O. dry contact *

OUTPUTS

Trip contact

SETTING

PERFORMANCE

Setting accuracy
Timing accuracy

RECORD

Fault record
Storage

: -15% to +0%
: 5%

OUTPUT CONTACTS

Rated voltage
Contact rating
: 3 latest tripped fault
currents or tSt for
manual test trip
: Non-volatile memory

: 250 V AC
: 5 A (NO)
3 A (NC)
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

: Red indicator
(Normal blink)
Time delay
: Red indicator
(Fast blink)
Leakage trip
: 7-segment display
and red indicator
ZCT connection error
: 7-segment display
and red indicator
Real-time leakage current : 7-segment display

ZERO - PHASE CURRENT TRANSFORMER

To operate with Mikros ZCT series of current


transformer

MECHANICAL

Mounting
Dimension (mm)
Enclosure protection
Approximate weight

: Panel mounting
: 96(w) x 96(h) x 90(d)
: IP54 at the panel
: 0.4 kg (excluding ZCT)

MK 300A / 300EA

Sensitivity adjustment : 30mA, 50mA,


0.10~1.00A(Step=50mA)
1.00~10.0A (Step=1.00A)
Time delay adjustment : Instantaneous,
0.1~3.0sec (Step=0.1s)

: Activated during leakage


trip, manual test trip or
ZCT connection error
Positive safety contact*: Activated when powerup and relay function
correctly
Alarm contact*
: Activated when
measured leakage
current exceeded 50%
of In.

INDICATORS

Pre-fault alarm

AUX

Case Dimensions

L1 L2 L3 N

MIKRO
ZCT

MK300A
1

12

13

14

15

16

96 mm

PE

The EARTH wire


must not pass
through the ZCT

SHUNT
TRIP

TRIP
CONTACT

NC

NO

Front

COM

11

10

96 mm

Earth Leakage Relay

Typical Application Diagram For MK300A

90 mm
70 mm

LOAD

Side

Typical Application Diagram For MK300EA


AUX

L1 L2 L3 N

REMOTE
RESET

MIKRO
ZCT

MK300EA
1

TRIP
CONTACT

NC

ALARM
CONTACT

COM NO

NO

10

11

12

CONTACTOR

POSITIVE SAFETY
CONTACT

COM NC

13

14

NO

15

COM

16

LOAD

Ordering Information
MODEL DESCRIPTION

MK 300A / 300EA

MK300A - 230A
MK300EA - 230A
MK300A - 110A
MK300EA - 110A
MK300A - 230A6
MK300EA - 230A6
MK300A - 110A6
MK300EA - 110A6

91.0 0.5 mm

PE

For 50Hz system, auxiliary voltage 184~276VAC


For 50Hz system, auxiliary voltage 184~276VAC
For 50Hz system, auxiliary voltage 94~127VAC
For 50Hz system, auxiliary voltage 94~127VAC
For 60Hz system, auxiliary voltage 184~276VAC
For 60Hz system, auxiliary voltage 184~276VAC
For 60Hz system, auxiliary voltage 94~127VAC
For 60Hz system, auxiliary voltage 94~127VAC

The EARTH wire


must not pass
through the ZCT

Panel Cutout

91.0 0.5 mm

Features
Numerical auto-reclosing earth leakage relay
Incorporated positive safety feature into trip
contact

Earth Leakage Relay

MK330A
One programmable contact for flexibility
Detection of no connection to ZCT
Relay trip / alarm indicator
Real-time leakage current display
Leakage fault current recording
Remote reset function
Standard DIN 96 x 96mm panel mounting
Protected against nuisance tripping

Technical Data
AUXILIARY SUPPLY

Sensitivity adjustment : 30mA, 50mA,


0.10~1.00A
(Step=50mA)
1.00~10.0A
(Step=1.00A)

Programmable contact: Option 0 = Disable


Option 1 = All (Option

2 to 6)
Option 2 = ZCT error

Option 3 = Leakage trip,

test trip,

re-close lockout
Option 4 =Re-close


lockout
Option 5 = Pre-fault alarm,


leakage trip,

test trip,

re-close lockout
Option 6 = Re-close


lockout,

ZCT error

Time delay adjustment: Instantaneous,


0.1~3.0sec (Step=0.1s)

Fault record

Model MK330A-230A : 184~276VAC


Model MK330A-110A : 94~127VAC
Rated frequency
: 50Hz
VA rating
: 3VA typical

PERFORMANCE

Setting accuracy
Timing accuracy

: -15% to +0%
: 5%

SETTING

Number of shots
Dead time

: 0~30 (Step=1, 0=Disable


auto re-close function)

Storage

: 1~500sec (Step=1sec)

INPUT

: 0~500min (Step=1min,
0=Disable function)

Lockout auto reset time: 0~200hour (Step=1Hr,


0=Disable function)

Remote reset

OUTPUTS

Trip safe contact

: 3 latest tripped fault


currents or tSt for
manual test trip
: Non-volatile memory
: N.O. dry contact

: Activated when the relay


is in normal power-up
condition with the
measured leakage current
less than 0.85 In.
Programmable contact: Activated according to
user setting

: 250 V AC
: 5 A (NO)
3 A (NC)
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

INDICATORS

Pre-fault alarm

: Red indicator (Normal


blink)
Time delay
: Red indicator (Fast blink)
Leakage trip
: 7-segment display and
red indicator
Re-close lockout
: 7-segment display and
red indicator
ZCT connection error : 7-segment display and
red indicator
Real-time leakage current : 7-segment display

ZERO-PHASE CURRENT TRANSFORMER

To operate with Mikros ZCT series of current


transformer

MECHANICAL

Mounting
Dimension (mm)
Enclosure protection
Approximate weight

: Panel mounting
: 96(w) x 96(h) x 90(d)
: IP54 at the panel
: 0.6 kg (excluding ZCT)

MK 330A

Persistent fault time : 0~500sec (Step=1sec,


0=Disable function)
Reclaim time

RECORD

OUTPUT CONTACTS

Rated voltage
Contact rating

Case Dimensions
96 mm

AUX

L1 L2 L3 N

REMOTE
RESET

PE
MIKRO
ZCT

MK330A
1

TRIP SAFE
CONTACT*

NC

NO

10

CONTACTOR

The EARTH wire


must not pass
through the ZCT

96 mm

Earth Leakage Relay

Typical Application Diagram

Front

PROGRAMMABLE
CONTACT

NC

COM

11

12

13

14

NO

15

COM

16

90 mm
70 mm
LOAD

* The trip safe contact is activated (terminal 10-11 closed) when

Side

the relay is in normal power-up condition with the measured


leakage current less than 0.85 In.

Panel Cutout

Ordering Information
MODEL DESCRIPTION
MK330A-230A

For 50Hz system, auxiliary voltage 184~276VAC

MK330A-110A

For 50Hz system, auxiliary voltage 94~127VAC

MK330A-230A6

For 60Hz system, auxiliary voltage 184~276VAC

MK330A-110A6

For 60Hz system, auxiliary voltage 94~127VAC

91.0 0.5 mm

91.0 0.5 mm

MK 330A

Earth Leakage Relay

MK302A
MK301A
MK301E

MK 301E

Features
Trip starting indicator
Detection of no connection to current transformer
MK 301A

for extra safety

Relay tripped indicator


High immunity to electrical interference

Features for MK 302A only


Safety output contact
Earth leakage level indicators
Remote reset and remote test functions
MK 302A

Technical Data
OUTPUT CONTACTS

ZERO - PHASE CURRENT TRANSFORMER

Contact arrangement : 1 x manual reset type



: 1 x safety contact*

: NC and NO contacts
available
Rated voltage
: 250 V AC
Contact rating
: 5A
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

To operate with Mikros ZCT series of current


transformer

SETTING RANGES
Sensitivity adjustment : 0.03 A to 30 A
Delay time adjustment : 0 sec to 3.0 sec

Setting accuracy
Timing accuracy

: -15% to +0%
: 5%

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

MECHANICAL

Remote Test* / Reset Inputs* : N.O. dry contact

Mounting
: Panel mounting
Dimension (mm)
: 96(w) x 96(h) x 90(d)
Approximate weight : 0.6 kg (excluding ZCT)

INDICATORS

* Applicable to MK302A series only

INPUTS

PERFORMANCE

ENVIRONMENTAL CONDITIONS
Temperature
Humidity

Auxiliary supply
Time delay
Trip
Real-time leakage current

: Green indicator
: Red indicator
: Red indicator
: Red indicator

** Applicable to MK301E series only

MK 302A / 301A / 301E

AUXILIARY SUPPLY
Model MK301A / 302A -240A : 198 ~ 265 V AC
Model MK301A / 302A -110A : 94 ~ 127 V AC
Rated frequency
: 50 / 60 Hz
VA rating
: 3 VA typical

Case Dimensions
96 mm

AUX

N
PE

LOAD
NO

NC

COM

8
SHUNT
TRIP

TRIP CONTACT
9

10

11

12

13

The EARTH wire


must not pass
through the ZCT

14

15

96 mm

Earth Leakage Relay

Typical Application Diagram

Front

90 mm
70 mm

16

MK301A or MK302A

Side
L1
L2
L3
N

AUX

91.0 0.5 mm
PE

LOAD
NO

10

11

NC

COM COM NC

NO

The EARTH wire


must not pass
through the ZCT

TRIP CONTACT SAFETY CONTACT*

12

13

14

15

16

CONTACTOR

MK302A
REMOTE
TEST*

AUX

L1
L2
L3
N

REMOTE RESET*

N
PE

LOAD
NO

NC C OM COM NC

NO

8
SHUNT
TRIP

TRIP CONTACT TRIP CONTACT 2**

10

11

12

13

14

15

16

L1
L2
L3
N

MK 302A / 301A / 301E

MK301E

Ordering Information
MODEL DESCRIPTION
MK301A - 240A
MK301A - 110A
MK302A - 240A
MK302A -110A
MK301E - 240A
MK301E -110A

For 50 / 60 Hz system, auxiliary voltage 198 ~ 265 V AC


For 50 / 60 Hz system, auxiliary voltage 94 ~ 127 V AC
For 50 / 60 Hz system, auxiliary voltage 198 ~ 265 V AC
For 50 / 60 Hz system, auxiliary voltage 94 ~ 127 V AC
For 50 / 60 Hz system, auxiliary voltage 198 ~ 265 V AC
For 50 / 60 Hz system, auxiliary voltage 94 ~ 127 V AC

The EARTH wire


must not pass
through the ZCT

Panel Cutout

91.0 0.5 mm

Features
Numerical auto-reclosing earth leakage relay
Incorporated positive safety feature into trip
contact

Earth Leakage Relay

DIN330
One programmable contact for flexibility
Detection of no connection to ZCT
Relay trip / alarm indicator
Real-time leakage current display
Leakage fault current recording
Remote reset function
Standard 35mm DIN rail mounting
Protected against nuisance tripping

Technical Data
AUXILIARY SUPPLY

Model DIN330-230 A(6) : 184 ~ 276 V AC


Rated frequency
: 50 or 60 Hz
VA rating
: 3 VA typical

PERFORMANCE

Setting accuracy
Timing accuracy

: -15% to +0%
: 5%

SETTING

Sensitivity adjustment : 30 mA, 50 mA,


0.10 A 1.00 A
(Step = 50 mA),
1.00 A 10.0 A
(Step = 1.00 A)
Time delay adjustment: Instantaneous,
0.1s 3.0s
Step = 0.10 sec.
Number of shots

Dead time

: 0 - 30. Step = 1.
0 = Disable auto reclose
function
: 1 - 500 sec. Step = 1 sec.

Permanent fault time : 0 - 500 sec. Step = 1 sec.


0 = Disable function

Lockout auto reset time: 0 - 200 hour


Step = 1 Hrs
0 = Disable function

RECORD

Fault record
Storage

INPUT

Remote reset

OUTPUTS

Trip safe contact

: 3 latest tripped fault


currents or tSt for
manual test trip
: Non-volatile memor

: N.O. dry contact

: Activated when the relay


is in normal power-up
condition with the

measured leakage current
less than 0.85 In.
Programmable contact: Activated according to
user setting

OUTPUT CONTACTS

Rated voltage
: 250 V AC
Contact rating
: 5 A (NO)
3 A (NC)
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

INDICATORS

50% pre-fault alarm : Red indicator (Normal


blink)
Time delay
: Red indicator (Fast blink)
Leakage trip
: 7-segment display and
red indicator
Reclose lockout
: 7-segment display and
red indicator
ZCT fault
: 7-segment display and
red indicator
Real time leakage current : 7-segment display

ZERO-PHASE CURRENT TRANSFORMER

To operate with Mikros ZCT series of current


transformer

ENVIRONMENTAL CONDITIONS

Temperature
Humidity

MECHANICAL

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

Mounting
: Panel mounting
Dimension (mm)
: 71(w) x 85(h) x 70(d)
Approximate weight : 0.4 kg (excluding ZCT)

DIN 330

Reclaim time
: 0 - 500 minute
Step = 1 min
0 = Disable function

Programmable contact : Option 0 = Disable


Option 1 = All (Option

2 to 6)
Option 2 = ZCT error

Option 3 = Leakage trip,

test trip,


re-close lockout

Option 4 = Re-close


lockout

Option 5 = Pre-fault alarm,


leakage trip,

test trip,


reclose lockout

Option 6 =Re-close


lockout,

ZCT error

AUX

PE

L1
L2
L3
N

Case Dimensions

REMOTE
RESET

MIKRO
ZCT

DIN330

TRIP SAFE CONTACT

10

11

COM NO

71 mm
The EARTH wire
must not pass
through the ZCT

20 mm
45 mm

Earth Leakage Relay

Typical Application Diagram

CONTACTOR

PROGRAMMABLE CONTACT

13

14

NC COM NO

12

NC

Front

20 mm

LOAD

70 mm
*

The trip safe contact is activated (terminal 9-10 closed) when


the relay is in normal power-up condition with the measured
leakage current less than 0.85 IDn.

85 mm

Side

30 mm 20 mm 20 mm

Ordering Information
MODEL DESCRIPTION
DIN330 - 230 A
DIN330 - 230 A6

For 50 Hz system, auxiliary voltage 230 V AC


For 60 Hz system, auxiliary voltage 230 V AC

DIN330

Features

Numerical earth leakage relay

Earth Leakage Relay

DIN310
DIN310E
Programmable current sensitivity and time delay
Detection of no connection to ZCT
Relay trip indicator
Relay alarm indicator
Real-time leakage current display

Features For DIN 310E only

Leakage fault current recording

Positive safety output contact

50% pre-fault indicator

50% pre-fault output contact

Standard DIN rail mounting

Remote reset function

Protection against nuisance tripping

Technical Data
AUXILIARY SUPPLY

DIN310-230 A(6)
DIN310E-230 A(6)
Rated frequency
VA rating

PERFORMANCE

Setting accuracy
Timing accuracy

: 184 ~ 276 V AC
: 184 ~ 276 V AC
: 50 or 60 Hz
: 3 VA typical
: -15% to +0%
: 5%

SETTING

Sensitivity adjustment : 30mA, 50mA,


0.10~1.00A
(Step=50mA)
1.00~10.0A
(Step=1.00A)

OUTPUT CONTACTS

Rated voltage
Contact rating

: 250 V AC
: 5 A (NO)
3 A (NC)
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

Storage

INPUT

Remote reset*

: 3 latest tripped fault


currents or tSt for
manual test trip
: Non-volatile memory

: N.O. dry contact

OUTPUTS

Trip Contact

: Activated if relay tripped


or ZCT fault
Positive safety contact* : Activated when ZCT is
connected properly to
the relay
Pre-fault alarm contact*: Activated when leakage
current exceeded 50% of
sensitivity setting

INDICATORS

50% pre-fault alarm : Red indicator


Time delay
: Red indicator
Leakage trip
: 7-segment display and red
indicator
ZCT fault
: 7-segment display and red
indicator
Real time leakage current: 7-segment display

ZERO-PHASE CURRENT TRANSFORMER

To operate with Mikros ZCT series of current


transformer

ENVIRONMENTAL CONDITIONS

Temperature
Humidity

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

MECHANICAL

Mounting
: Panel mounting
Dimension (mm)
: 71(w) x 85(h) x 70(d)
Approximate weight : 0.4 kg (excluding ZCT)
* Applicable to DIN310E series only

DIN 310 / 310E

Time delay adjustment: Instantaneous,


0.1~3.0sec
Step=0.10 sec

RECORD

Fault record

AUX

PE

L1
L2
L3
N

Case Dimensions

MIKRO
ZCT

The EARTH wire


must not pass
through the ZCT

DIN310

13

14

71 mm
20 mm

SHUNT
TRIP

45 mm

Earth Leakage Relay

Typical Application Diagram For DIN 310

TRIP
CONTACT

10

11

COM NO

12

Front

20 mm

NC

LOAD

70 mm

Typical Application Diagram For DIN 310E


N

PE

L1
L2
L3
N

AUX

REMOTE
RESET

MIKRO
ZCT

DIN310E

1
ALARM CONTACT

TRIP CONTACT

10

COM NO

12

NC

COM NO

13

30 mm 20 mm 20 mm

14
NC
LOAD

Ordering Information
MODEL DESCRIPTION
DIN310 - 230 A
DIN310E - 230 A
DIN310 - 230 A6
DIN310E - 230 A6

Side

CONTACTOR

SAFETY CONTACT

11

The EARTH wire


must not pass
through the ZCT

85 mm

For 50 Hz system, auxiliary voltage 230 V AC


For 50 Hz system, auxiliary voltage 230 V AC
For 60 Hz system, auxiliary voltage 230 V AC
For 60 Hz system, auxiliary voltage 230 V AC

* 60Hz system, auxiliary voltage 110V AC model available upon special request.

DIN 310 / 310E

Earth Leakage Relay

DIN300
DIN300E
Features
25 selectable sensitivity settings:
30 mA to 30 A

9 selectable time delays: 0ms to 3s


Earth leakage level indicators
Detection of no connection to ZCT

Features For DIN 300E only

Relay tripped indicator

50% pre-fault output contact

Trip starting indicator

Remote test and remote reset functions

Protected against nuisance tripping

Technical Data
AUXILIARY SUPPLY

Model DIN300 / 300E -240A : 198 ~ 265 V AC


Model DIN300 / 300E -110A : 94 ~ 127 V AC
Rated frequency
: 50 / 60 Hz
VA rating
: 3 VA typical

SETTING RANGES

Sensitivity setting

PERFORMANCE

Setting accuracy
Timing accuracy

: 30 mA, 50 mA, 75 mA,


100 mA, 125 mA, 150 mA, INPUT
200 mA, 250 mA, 300 mA, Remote test* / Reset inputs* : N.O. dry contacts
500 mA, 750 mA, 1 A,
1.25 A, 1.5 A, 2 A, 2.5 A,
3 A, 5 A, 7.5 A, 10 A, 12.5 A, ZERO-PHASE CURRENT TRANSFORMER
15 A, 20 A, 25 A, 30 A.
To operate with Mikros ZCT series of current
transformer
: Instantaneous, 50 ms,
100 ms, 150 ms, 250 ms,
350 ms, 500 ms, 1 s, 3 s.
INDICATORS
Auxiliary supply
: Green indicator
Time delay
: Red indicator
Trip
: Red indicator
: -15% to +0%
Leakage current* : 5 red indicators for
: 5%
leakage levels

ENVIRONMENTAL CONDITIONS
Temperature
Humidity

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

MECHANICAL
Mounting
Dimension (mm)
Enclosure protection
Approximate weight

: DIN rail mounting


: 71(w) x 85(h) x 70(d)
: IP54 at the panel
: 0.4 kg (excluding ZCT)

* Applicable to DIN300E model only

DIN 300 / 300E

Time delay setting

OUTPUT CONTACTS

Contacts ( Trip / 50% pre-fault* )


Rated voltage
: 250 V AC
Contact rating
: 5 A
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

Case Dimensions
PE

L1
L2
L3
N

AUX

S1
The EARTH wire
must not pass
through the ZCT

S2

10

11

12

COM

13
NO

20mm

SHUNT
TRIP

TRIP CONTACT

71mm

45mm

Earth Leakage Relay

Typical Application Diagram For DIN 300

20mm

14
NC

Front view

LOAD

71mm

50% PRE-FAULT CONTACT

9
COM

10
NO

11

S1
The EARTH wire
must not pass
through the ZCT

S2

SHUNT
TRIP

TRIP CONTACT

12

NC COM

13
NO

14
NC
LOAD

Ordering Information
MODEL DESCRIPTION
DIN300 - 240 A
DIN300 - 110 A
DIN300E - 240 A
DIN300E - 110 A

PE

L1
L2
L3
N

REMOTE TEST

AUX

For 50 / 60 Hz system, auxiliary voltage 240 V AC


For 50 / 60 Hz system, auxiliary voltage 110 V AC
For 50 / 60 Hz system, auxiliary voltage 240 V AC
For 50 / 60 Hz system, auxiliary voltage 110 V AC

85mm

REMOTE RESET

Typical Application Diagram For DIN 300E


Side view

30mm

20mm 20mm

DIN 300 / 300E

Earth Leakage Relay

ZCT40S
ZCT60S
ZCT80S
ZCT120S
ZCT210S

40S

80S
60S

Case Dimensions
Front

B
D

210S

120S

d4

3 wire


MODEL

D
ZCT inner
diameter (mm)

4 wire

d3, 3 wire
Up till wire
diameter (mm)

d4, 4 wire
Up till wire
diameter (mm)


ZCT 40S
40 14 12

ZCT 60S
60 23 21

ZCT 80S
80 32 29
ZCT 120S
120
51
46
ZCT 210S
210
93
83

Example:
For a single core CU / PVC insulated, non-sheathed 450 / 750 V 50mm2 conductor,
its nominal overall diameter is 11.7mm. To pass 4 wires through the ZCT, we can use
ZCT40S as the maximum diameter it can support is up till 12mm.

Bottom

DIMENSION

(mm)
ZCT Model
40S 60S 80S 120S
210S






A 40 60 80 120
210
B 89 105 130 180 310
C 94 110 135 195 311
D 6 6 6 6 6
E 37 37 37 37 37
F 75 87 112 159 292
G 27 27 27 27 18

Ordering Information
MODEL

DESCRIPTION

ZCT40S
ZCT60S
ZCT80S
ZCT120S
ZCT210S

40mm inner diameter


60mm inner diameter
80mm inner diameter
120mm inner diameter
210mm inner diameter

WEIGHT
0.16 kg
0.20 kg
0.28 kg
0.57 kg
1.5 kg

ZCT 40S / 60S / 80S / 120S / 210S

Calculation to determine Inner Diameter of ZCT required

d3

Digital Power Meter

DVM
Features
Built-in selector switch
Easy-to-read, 14.2mm digit display
DIN size casing

Technical Data
Auxiliary supply
: 198 ~ 265 V AC

: 94 ~ 127 V AC
VA rating
: 3 VA
Input frequency
: 47 ~ 66 Hz
Maximum input voltage : 500 Vrms
Approximate weight : 0.6 kg

Typical Application Diagram


DVM360 Series

DVM100 Series

L1

L2

L3
N
1

10

11

12

10

11

12

Aux Supply
AC 240 V

Aux Supply
AC 240 V

Case Dimensions
91.5 mm

Front

87 mm

Side

Ordering Information

DVM

MODEL DESCRIPTION
DVM360 - 240A
DVM100 - 240A
DVM360 - 110A
DVM100 - 110A

Auxiliary voltage 240 V AC


Auxiliary voltage 240 V AC
Auxiliary voltage 110 V AC
Auxiliary voltage 110 V AC

91.0 0.5 mm

Panel Cutout

91.0 0.5 mm

96 mm

96 mm

Digital Power Meter

DAM
Features
Built-in selector switch
Easy-to-read, 14.2mm digit display
DIN size casing
Wide selection of current transformer
(CT) ratio

Technical Data
Auxiliary supply

VA rating
Input frequency
Maximum input
Ammeter CT ratio
Class
Approximate weight

: 198 ~ 265 V AC
: 94 ~ 127 V AC
: 3 VA
: 47 ~ 66 Hz
: 6 A continuous
: .../5 A
: 1.0
: 0.7 kg

Typical Application Diagram


DAM330 / 3000 Series

DAM100 / 1000 Series

L1

L2

L3
1
7

2
8

3
9

4
10

5
11

10

11

12

6
12
Aux Supply
AC 240 V

Aux Supply
AC 240 V

Case Dimensions
91.5 mm

Front

87 mm

Side

91.0 0.5 mm

Panel Cutout

91.0 0.5 mm

96 mm

96 mm

DAM

Digital Power Meter

Ordering Information
MODEL
/SERIES

WITH
SELECTOR

WITHOUT
SELECTOR

DISPLAY
FORMAT

UNIT

DAM330

DAM3000

DAM100

DAM1000

For primary current


from 60 A to 500 A

For primary current


from 600 A to 5000 A

DAM 330 - XXXX


DAM 100 - XXXX

DAM 3000 - XXXX


DAM 1000 - XXXX

Order number

Order number

Model DAM 330 & DAM 100

ORDER NUMBER

*CT RATIO

Model DAM3000 & DAM1000


ORDER NUMBER

*CT RATIO

0060

60 / 5 A

600

600 / 5 A

0100

100 / 5 A

800

800 / 5 A

0150

150 / 5 A

1000

1000 / 5 A

0200

200 / 5 A

1200

1200 / 5 A

0250

250 / 5 A

1500

1500 / 5 A

0300

300 / 5 A

1600

1600 / 5 A

0400

400 / 5 A

2000

2000 / 5 A

0500

500 / 5 A

2400

2400 / 5 A

2500

2500 / 5 A

Example: Model DAM 330 - 0060 for

3000

3000 / 5 A

digital ammeter with CT ratio


60 / 5 A.

3200

3200 / 5 A

3500

3500 / 5 A

4000

4000 / 5 A

4500

4500 / 5 A

5000

5000 / 5 A

*CT : Current Transformer



For other CT ratio, please contact
the manufacturer.

DAM

MODEL

DESCRIPTION

DAM330 - xxxx - 240A

Auxiliary voltage 240 V AC

DAM100 - xxxx - 240A

Auxiliary voltage 240 V AC

DAM330 - xxxx - 110A

Auxiliary voltage 110 V AC

DAM100 - xxxx - 110A

Auxiliary voltage 110 V AC

DAM3000 - xxxx - 240A

Auxiliary voltage 240 V AC

DAM1000 - xxxx - 240A

Auxiliary voltage 240 V AC

DAM3000 - xxxx - 110A

Auxiliary voltage 110 V AC

DAM1000 - xxxx - 110A

Auxiliary voltage 110 V AC

Features
Measurement Parameters:
Phase & Line Voltages (L-N)
Phase Current & Neutral Current
Bidirectional kW, kVAR & kVA
Bidirectional kWh, kVARh & kVAh
Frequency
Total & Displacement Power Factor
Voltage Total Harmonic Distortion
Current Total Harmonic Distortion
Thermal Current Demand
Power Demand
Current Sequence Components
Voltage Sequence Components

Digital Power Meter

DPM680

TFT Colour LCD Display


Serial RS-485 Modbus RTU
Modbus TCP/IP
Built-in Webserver
Voltage & Current Waveform Display
Voltage & Current Harmonics Display

Technical Data
WIRING SYSTEMS

3-phase 4-wire system


3-phase 3-wire system

CURRENT MEASUREMENT (TRMS)

Nominal current
:5A
Min. measurement : 5 mA
Accuracy
: 0.2% of full scale
Burden
: < 0.05 VA at 5 A
Measurement range : 10 A
Pulsed withstand : 100 A for 1 sec
CT primary
: 5 ~ 50,000 A

VOLTAGE MEASUREMENT (TRMS)

Nominal phase voltage : 0 ~ 300 V AC


Minimum measurement : 10 V
Accuracy
: 0.2% at full scale
Phase voltage via VT : 60 ~ 50,000 V

Protocol
Interface

: Modbus TCP/IP
: Ethernet 10M/100M BaseT

VOLTAGE AND CURRENT SEQUENCE


COMPONENTS

Protocol
Interface

: HTTP Server
: Ethernet 10M/100M BaseT

FREQUENCY MEASUREMENT

AC voltage
Frequency
DC voltage
Power consumption
Sustained overload

: 1 ~ 30 mins

Positive, negative and zero sequence


Measurement range
Accuracy

: 45 ~ 65 Hz
: 0.2%

ENERGY MEASUREMENT ACCURACY

Active
Reactive

: IEC 62053-22 class 0.5


: IEC 62053-23 class 2

HARMONICS DISPLAY

Fundamental up to 32nd order

VOLTAGE & CURRENT WAVEFORM


DISPLAY

Real power, apparent power, reactive power


Accuracy
: 0.5%

Simultaneous 3-phase voltage or


current waveforms

POWER FACTOR MEASUREMENT

COMMUNICATION

Total and displacement power factor


Accuracy
: 0.5%

Protocol
Interface

: Modbus RTU
: Isolated RS485

AUXILIARY POWER SUPPLY

: 90 ~ 415 V AC
: 50 / 60 Hz
: 100 ~ 300 V DC
: 3W typical
: 500 V AC

ENVIRONMENTAL CONDITIONS

Overvoltage category
Pollution degree
Operating temperature
Storage temperature
Humidity

MECHANICAL

Mounting

: IV
:2
: -10C ~ +55C
: -20C ~ +70C
: 0 95%,
non condensing

: according to DIN 43700 /


ANSI C39.1
Dimension (mm)
: 96(w) x 96(h) x 100(d)
Enclosure protection : IP63 at the panel
IP20 at the body
Approximate weight : 0.5 kg

DPM 680

POWER MEASUREMENT

POWER & THERMAL CURRENT DEMAND

Interval

96 mm
3-PHASE 4-WIRE SYSTEM : 4 CTs, Direct V Input

3-PHASE 4-WIRE SYSTEM : 3 CTs, Direct V Input

L1 L2 L3 Ln

L1 L2 L3 Ln

90~415 V AC /

90~415 V AC /

AUX 100~300 V DC

AUX 100~300 V DC

S1

S1

S2
S1
S2
S1
S2

S1
S2

GND

l1

S1

l2 Ethernet

S2
S1

l3

S2

S1

ln

S2

GND

RS 485

L1
L2

S2

Modbus-RTU

L3
Ln

LOAD

l2 Ethernet
l3
ln

RS 485
Modbus-RTU

90 mm

L3
Ln

Front

l1

L1
L2

96 mm

Digital Power Meter

Case Dimensions

Typical Application Diagrams

LOAD

Side
3-PHASE 3-WIRE SYSTEM : 3 CTs, Direct V Input

90~415 V AC /

90~415 V AC /

AUX 100~300 V DC

AUX 100~300 V DC

S1

S1

S2
S1
S2
S2

S1
S2

S2
S1

l2 Ethernet

S2
S1

l3

S2

S1

ln

S2

l1
l2 Ethernet
l3

Rear
ea

ln

GND

GND

RS 485

L1
L2

LOAD

17 mm

86 mm

S1

l1

83 mm
0m

L1 L2 L3

10

3-PHASE 3-WIRE SYSTEM : 3 CTs, 3 VTs

L1 L2 L3

L1

Modbus-RTU

L2

L3

L3

Ln

Ln

GND

RS 485
Modbus-RTU

LOAD

Test Standards

Cut-Out Recommendations

IEC 61010-1
Safety requirements.
910.5mm

IEC 61326-1
EMC requirements.

910.5mm

Ordering Information

DPM 680

MODEL

DESCRIPTION

DPM 680-415AD

Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC

101.60.5mm

Digital Power Meter

DPM380
DPM380B
Features
LCD display with back lighting
Modbus-RTU communication
(for DPM380 only)

MEASUREMENT PARAMETERS:
Phase Voltage (L-N)
Line Voltage (L-L)
Phase Current and Neutral Current
Bidirectional kW (per phase & total)
Bidirectional kVAR (per phase & total)
Bidirectional kVA (per phase & total)
Frequency
Power Factor (per phase & total)
Energy (+ and - ) for kWh, kVARh and kVAh
THD Phase Voltage ( L-N )
THD Phase Current
Active Power Demand

Technical Data
DISPLAY TYPE

LCD display

MEASUREMENTS

3-phase 4-wire system


3-phase 3-wire system

POWER MEASUREMENT

Real power, apparent power, reactive power


measurement
Measuring updating period : 1 s
Accuracy
: 1.0%

ACTIVE POWER DEMAND

Interval

CURRENT MEASUREMENT (TRMS)

VOLTAGE MEASUREMENT (TRMS)

Nominal phase voltage : 20 ~ 300 V AC


Minimum measurement : 10 V
Accuracy
: 0.5% at full scale
Phase voltage via VT : 60 ~ 33,000 V

POWER FACTOR MEASUREMENT

Total and displacement power factor


Accuracy
: 1.0%

AC voltage
Frequency
DC voltage
Power consumption

COMMUNICATION

Hardware interface
Protocol
Baud rate

: 90 ~ 415 V AC
: 50 / 60 Hz
: 100 ~ 300 V DC
: <3 VA

: Isolated RS485
: Modbus-RTU
: 2400, 4800, 9600,
19200, 38400

ENVIRONMENTAL CONDITIONS

FREQUENCY MEASUREMENT

Operating temperature : -10C ~ +55C


Storage temperature
: -20C ~ +70C
Humidity
: 0 95%,
non condensing

ENERGY ACCURACY

Mounting
Dimension (mm)
Approximate weight

Measurement range
: 45 ~ 65 Hz
Measurement updating period : 1s
Accuracy
: 0.5%

Active (according to IEC 62053-21) : class 1


Reactive (according to IEC 62053-23) : class 2

MECHANICAL

: Panel mounting
: 96(w) x 96(h) x 100(d)
: 0.5 kg

DPM 380 / 380B

CT primary
: 5 ~ 8000 A
CT secondary
: 5 A
Minimum measurement : 5 mA
Accuracy
: 0.5% from 1A to
6 A (secondary)
Burden
: < 0.05 VA at 5 A
Sustained overload
: 6 A

: 1 ~ 30 mins

AUXILIARY POWER SUPPLY

3-PHASE 4-WIRE SYSTEM WITH 4 CTs CONNECTION

96 mm

L1 L2 L3 Ln
90~415 V AC /

AUX 100~300 V DC
S1
S2
S1
S2
S1
S2

S1
S2
L1
L2

Front

l1
l2
l3
ln

* For DPM380 only

+
RS 485
Modbus-RTU

Side

GND

L3

90 mm

GND

96 mm

Digital Power Meter

Case Dimensions

Typical Application Diagram

Ln

83 mm

LOAD

10

0m

17 mm

3-PHASE 4-WIRE SYSTEM WITH 3 CTs CONNECTION

Rear
ea

90~415 V AC /

AUX 100~300 V DC
S1
S2
S1
S2
S1
S2

S1
S2

GND

L1
L2

86 mm

L1 L2 L3 Ln

l1

86 mm

l2
l3
ln

* For DPM380 only

Cut-Out Recommendations

+
RS 485
Modbus-RTU

L3

GND

Ln

910.5mm

LOAD

Electromagnetic Compatibility (EMC)

910.5mm

DPM 380 / 380B

Part 6-2: Generic Standards IEC61000-6-2


Immunity for industrial environments.

Part 6-4: Generic Standards IEC61000-6-4


Emission standard for industrial environments.

Ordering Information
MODEL

DESCRIPTION

DPM 380-415AD
DPM 380B-415AD

Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC, with RS 485


Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC

101.60.5mm

Digital Power Meter

DM38
Features
LCD display with back lighting
Modbus-RTU communication
DIN rail type

MEASUREMENT PARAMETERS:
Phase Voltage ( L-N )
Line Voltage ( L-L )
Phase Current
Bidirectional kW (per phase & total)
Bidirectional kVAR (per phase & total)
Bidirectional kVA (per phase & total)
Frequency
Power Factor (per phase & total)
Energy (+ and - ) for kWh, kVARh and kVAh
THD Phase Voltage ( L-N )
THD Phase Current

Technical Data
DISPLAY TYPE

POWER MEASUREMENT

LCD display

MEASUREMENTS

Self supplied
Frequency
Power consumption

POWER FACTOR MEASUREMENT

Hardware interface
Protocol
Baud rate

3-phase 4-wire system

CURRENT MEASUREMENT (TRMS)

CT primary
CT secondary
Minimum measurement
Accuracy

Burden
Sustained overload

: 5 ~ 8000 A
:5A
: 10 mA
: 0.5% from 1A to
6 A (secondary)
: < 0.03 VA at 5 A
:6A

VOLTAGE MEASUREMENT (TRMS)

Total and displacement power factor


Accuracy
: 1.0%

FREQUENCY MEASUREMENT

Measurement range
Measurement updating period
Accuracy

ENERGY ACCURACY

: 45 ~ 65 Hz
: 1s
: 0.5%

Active (according to IEC 62053-21) : class 1


Reactive (according to IEC 62053-23) : class 2

COMMUNICATION

: 100 ~ 240 V AC
: 50 / 60 Hz
: <3 VA

: Isolated RS485
: Modbus-RTU
: 2400, 4800, 9600,
19200, 38400

ENVIRONMENTAL CONDITIONS

Operating temperature : -10C ~ +55C


Storage temperature
: -20C ~ +70C
Humidity
: 0 95%,
non condensing

MECHANICAL

Mounting
Dimension (mm)
Approximate weight

: DIN rail
: 65(w) x 85(h) x 50(d)
: 0.3 kg

DM 38

Nominal phase voltage : 70 ~ 300 V AC


Minimum measurement : 10 V
Accuracy
: 0.5% at full scale

POWER SUPPLY

Real power, apparent power, reactive power


measurement
Measuring updating period
:1s
Accuracy
: 1.0%

DM 38 CONNECTION DIAGRAM
S1 S2

S1 S2

I2

120 Ohm

I3

10

11

I1

RS 485

Modbus-RTU

S1 S2

GND

Digital Power Meter

Typical Application Diagram

P1

LOAD

L1
L2
L3
Ln
12

L1

13

14

L2

15

16

L3

17

18

19

20

21

22

S1
S2

P2

DM38

NOTE: Current transformer secondary


terminal MUST NOT be earthed.

Ln

Electromagnetic Compatibility (EMC)

Case Dimensions

Part 6-2: Generic Standards IEC61000-6-2

Front

Immunity for industrial environments.

65 mm

Part 6-4: Generic Standards IEC61000-6-4


Emission standard for industrial environments.
45.5 mm

85 mm

Ordering Information
MODEL

DESCRIPTION

DM 38-240A

Self Powered 100~240 V AC

71 mm

Side
50 mm

DM 38

15.5 mm

Voltage Relay

MU350
Product Description
MU350 is 3-phase voltage relay that combines
various protections and starting delay.

Features
Undervoltage
Overvoltage
Delay-on
2 voltage-free output contacts
Voltage and frequency display
3-Phase
Unbalance
Phase loss
Phase sequence
With or without neutral connection
Phase to phase or phase to neutral monitoring
Programmable relay outputs
ANSI Code : 27, 47, 59, 60

Technical Data
SETTING RANGES

Undervoltage
Time delay for undervoltage
Overvoltage
Time delay for overvoltage
Start time delay
Unbalance
Time delay for unbalance
Phase loss
Phase sequence

:
:
:
:
:
:
:
:
:

Off, 1% to 25%
0.1s to 30s
Off, 1% to 20%
0.1s to 30s
0s to 999s
Off, 3% to 20%
0.5s to 30s
Fixed time <0.5s
Fixed time <0.5s

AUXILIARY SUPPLY

MU350-415V : 380 V (-25%) to 415 V (+20%) AC


Supply frequency : 45 Hz to 65 Hz
Maximum power consumption: 3VA

Line to line : 100 to 415 (+20%) VAC


Line to Neutral : 58 to 240 (+20%) VAC

Rated voltage
: 250 V AC
Contact rating
: 5 A
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

INDICATORS

Auxiliary supply
Pickup indicator
Trip

ENVIRONMENTAL CONDITIONS
Temperature
Humidity

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

MECHANICAL

Mounting
: Panel mounting
Dimension (mm)
: 96(w) x 96(h) x 90(d)
Approximate weight : 0.31 kg
: Green indicator
: Red indicator
: 7-segment display and
red LED indicators

ACCURACY

Protection thresholds : 3%
Time delay
: 0 to 0.5s, 15% with
minimum 40ms

: 0.6s and above, < 3%
Measurements
: 3%

MU 350

MEASURING INPUT

OUTPUT CONTACTS

96 mm

L1
L2
L3
N

L-L 100-415V AC, L-N 58-240V AC

L1

L2

L3

(OPTIONAL)

R2

R1

AUX

NC

NO

COM

NC

NO

COM

96 mm

Voltage Relay

Case Dimensions

Typical Application Diagrams

Front

90 mm
70 mm

380-415V AC

Side

Ordering Information
MODEL DESCRIPTION
MU350-415V 3-Phase, auxiliary voltage 380 ~ 415 V AC, 45-65 Hz

Panel Cutout

91.0 0.5 mm

91.0 0.5 mm

MU 350

Voltage Relay

MU250
MU150
Product Description
MU150 and MU250 are voltage relays that
combine various protections and starting delay.
MU 150

MU150 is used for single-phase monitoring while


MU250 is used for 3-phase monitoring.

Features






Microprocessor based numerical relay


Undervoltage
Overvoltage
Delay-on
2 voltage-free output contacts
Voltage and frequency display
ANSI Code : 27, 47, 59, 60

Features For MU 250 only

MU 250

3-Phase
Unbalance
Phase loss
Phase sequence
With or without neutral connection
Phase to phase or phase to neutral monitoring

Technical Data
SETTING RANGES

Undervoltage
Time delay for undervoltage
Overvoltage
Time delay for overvoltage
Start time delay

For MU250 only:

:
:
:
:
:

1% to 25%
0.1s to 30s
1% to 20%
0.1s to 30s
0s to 999s

MU150-110V & MU250-110V



: 100 V (-25%) to 120 V (+20%) AC
MU150-240V & MU250-220V

: 220 V (-25%) to 240 V (+20%) AC
MU250-415V

: 380 V (-25%) to 415 V (+20%)
Supply frequency : 45 Hz to 65 Hz

Maximum power consumption:


MU250 : 3VA
MU150 : 2.5VA

OUTPUT CONTACTS

Rated voltage
: 250 V AC
Contact rating
: 5 A
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

INDICATORS

Auxiliary supply
Pickup indicator
Trip

: Green indicator
: Red indicator
: 7-segment display and red
LED indicators

ACCURACY

Protection thresholds : 3%
Time delay
: 0 to 0.5s, 15% with
minimum 40ms

: 0.6s and above, < 3%
Measurements
: 3%

ENVIRONMENTAL CONDITIONS
Temperature
Humidity

MECHANICAL

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

Mounting
: DIN rail
Dimension (mm)
: 71(w) x 85(h) x 70(d)
Approximate weight : 0.4 kg

MU 250 / 150

Unbalance
: 3% to 20%
Time delay for unbalance : 0.1s to 30s
Phase loss
: Fixed time <0.1s
Phase sequence
: Fixed time <0.1s

POWER SUPPLY INPUT


Input voltage:

Voltage Relay

Typical Application Diagrams


MU250

MU150

L1
L2
L3
N

L
N

(OPTIONAL)

1
1

R1

COM NO

10

11

12

NC

8
13

COM NO

13

14

R2

COM NO

14
NC

R1

R2

10
NC

11

12

COM NO

NC

MU150

MU250

(Neutral connection is optional)

Case Dimensions
71 mm
20 mm
45 mm

Front

20 mm

70 mm

85 mm

Side

30 mm 20 mm 20 mm

Ordering Information
MODEL DESCRIPTION
MU150-110V

Single-Phase, 220/230/240 V AC,


45-65 Hz power supply

MU150-240V

Single-Phase, 220/230/240 V AC,


45-65 Hz power supply

MU250-110V

3-phase, 100/110/120 V AC
45-65 Hz power supply

MU250-220V

3-phase, 220/230/240 V AC
45-65 Hz power supply

MU250-415V

3-Phase, 380/400/415 V AC,


45-65 Hz power supply

MU 250 / 150

Voltage Relay

MU2300
Features
Multifunction numerical voltage protection relay
Low-set undervoltage stage (U<) with definitetime or inverse-time characteristic
High-set undervoltage stage (U<<) with definitetime
Low-set overvoltage stage (U>) with definite-time
or inverse-time characteristic
High-set overvoltage stage (U>>) with definitetime
Negative sequence overvoltage protection (U2>)
with definite-time or inverse-time characteristic
Neutral displacement / residual overvoltage
protection (U0>)with definite-time or inverse-time
characteristic
Can be used in single-phase or three-phase
operation

Introduction

Multi-function isolated digital input with wide


input voltage range

The MU2300 is a microprocessor based numerical


relay for voltage protection functions in electrical
distribution network.

Fault record and event code recording


Five programmable voltage-free output contacts
Isolated RS485 Modbus - RTU communication
ANSI Code : 27, 47, 59, 60

Technical Data
INPUTS
Measuring input:
Rated voltage input
Rated frequency

: 57 ~ 130 V
: 50 / 60 Hz

Rated auxiliary voltage:


Model MU2300-150D
Model MU2300-240AD

: 24 ~ 150 V DC
: 85 ~ 265 V AC
110 ~ 340 V DC

Power consumption:
AC auxiliary voltage
DC auxiliary voltage

: 6 ~ 10 VA typical
: 5 ~ 9 W typical

RS485 Modbus - RTU

Rated voltage
Continuous carry
Make and carry for 0.2 s
Expected electrical life

Negative sequence over-voltage setting, U2>


: 5 - 200 V
Time multiplier, TMS
: 0.5 - 100
Negative sequence over-voltage definite time tU2>
: 0 - 600 s

: 250 V AC / DC
:5A
: 30 A
: 100,000 operations
at rated current
Expected mechanical life : 5 x 106 operations

RESIDUAL OVER-VOLTAGE ELEMENT


UNDER-VOLTAGE ELEMENT
Low set setting U<
: 5 - 130 V
High set setting U<<
: 5 - 130 V
Time multiplier, TMS
: 0.5 - 100
Low set Definite time tU< : 0 - 600 s
High set Definite time tU<< : 0 - 600 s

Residual over-voltage setting, U0> : 0.5 - 130 V


Time multiplier, TMS
: 0.5 - 100
Residual over-voltage definite time tU0>: 0 - 600 s

ENVIRONMENTAL CONDITIONS
Temperature
Humidity

: 85 ~ 265 V AC/DC

Low set setting U>


: 5 - 200 V
High set setting U>>
: 5 - 260 V
Time multiplier, TMS
: 0.5 - 100
Low set definite time tU> : 0 - 600 s
High set definite time tU>> : 0 - 600 s

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

MECHANICAL
Mounting
Dimension (mm)
Enclosure protection
Approximate weight

: Panel mounting
: 142(w) x 165(h) x 198(d)
: IP54 at the panel
: 2.7 kg

MU 2300

COMMUNICATION

NEGATIVE SEQUENCE OVER-VOLTAGE


ELEMENT

OVER-VOLTAGE ELEMENT

Binary Input:
External binary input

OUTPUT CONTACTS
5 programmable contacts +1 IRF contact:

Case Dimensions

Overvoltage Characteristic
100

10
TMS=8
TMS=

10

5
TMS=
3
TMS=

142 mm

10

165 mm

100

Operating time (sec)

Operating time (sec)

Voltage Relay

Undervoltage Characteristic

1
TMS=10
TMS=8
TMS=5
TMS=3

0.1

Front

TMS=1

1
TMS=

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

0.01

Applied voltage/relay setting voltage

10

12

14

16

18

20

Applied voltage/relay setting voltage

198 mm
34 mm

Typical Application Diagrams


A
B
C
2
3
5
6
8

136 mm

A
B
C
34 Trip Contact
36 R1
35

38
37 R2

40
39 R3

Side

34 Trip Contact
36 R1
35
38
37 R2
40
39 R3

129 1 mm

11
12
13
External
Digital
Input 14
Uaux

32
33
31

42
41 R4

11

27
26 R5

12

28 Internal
30 Relay
29 Failure
22

13
External
Digital 14
Input

Termination Resistor

23 N-

24 P+
25

Uaux

Communication
Cable Shield

31

Phase rotation

28 Internal
30 Relay
29 Failure
22

Panel Cutout

Termination Resistor

23 N-

24 P+
25

Communication
Cable Shield

2Vp-p + Vresidual connection

A
B
C

3
5
6
8
9
11
12

MU 2300

13
External
Digital
Input 14
Uaux

Ordering Information

A
B
C
2

32
33
31

27
26 R5

Phase rotation

3Vp-p + Vresidual connection

32
33

42
41 R4

139 1 mm

34 Trip Contact
36 R1
35

38
37 R2

40
39 R3

8
9

42
41 R4

11

27
26 R5

12

28 Internal
30 Relay
29 Failure
22

24 P+
25

Phase rotation

3Vp-n + Vresidual connection

Uaux

Communication
Cable Shield

42
41 R4
27
26 R5

32
33

24 P+

Phase rotation

3Vp-n connection

MODEL DESCRIPTION
MU2300-150D

For 50 / 60 Hz system, auxiliary


voltage 24 ~ 150 V DC

40
39 R3

28 Internal
30 Relay
29 Failure
22

31

38
37 R2

13

External
Digital 14
Input

Termination Resistor

23 N-

34 Trip Contact
36 R1
35

Termination Resistor

23 N25

Communication
Cable Shield

MU2300-240AD For 50 / 60 Hz system, auxiliary


voltage 85 ~ 265 V AC or
110~340 V DC

Features
Numerical voltage protection relay
Undervoltage
Overvoltage
Phase loss

3 - Phase Voltage Relay

MX210
Phase sequence
3-Phase/Single-phase
ANSI Code: 27, 47, 59

Product Description
MX210 is voltage relay that combines
overvoltage, undervoltage, phase loss,
phase sequence and delay start functions.
MX210 can be programmed by user to
set nominal voltage as well as set into 3phase or Single-phase mode.

Technical Data
POWER SUPPLY INPUT
3-Phase System

Phase-to-phase voltage : 380 V (-25%) to 415 V


(+20%) AC

Single Phase

Phase-to-neutral voltage : 220 V (-25%) to 240 V


(+20%) AC
Frequency range
: 45 to 65 Hz
Max. power consumption : 3 VA maximum

OUTPUT CONTACTS

Rated voltage
: 250 V AC
Contact rating
: 5 A
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

SETTING RANGES
Undervoltage
Overvoltage
Delay time
Normal voltage

: 78% - 98%
: 102% - 122%
: 0.1 - 10s
: 380, 400, 415 Vpp, 220,
230, 240, Vpn

INDICATORS

Power supply ON
Output ON
Undervoltage
Overvoltage
Phase error

: Green indicator
: Green indicator
: Red indicator
: Red indicator
: Red indicator

3-phase / Single-phase

ENVIRONMENTAL CONDITIONS

ACCURACY

Protection thresholds
Hysteresis
Delay time

Measurements

: 3%
: 1%
: 0-0.5s, 15%,
40ms minimum
: 0.5s and above, 3%
: 3%

Temperature
Humidity

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

MECHANICAL

Mounting
: DIN rail
Dimension (mm)
: 71(w) x 85(h) x 70(d)
Approximate weight : 0.3 kg

MX 210

3 - Phase Voltage Relay

Wiring Diagram
Single-Phase System

3-Phase System

L1

L2
L3
1

10

11

12

13

14

R1
1
8

10

11

12

13

14

R1
8

Operations Diagram
i ) Over Voltage Function
Over Voltage Limit
Hysteresis
R
Y
B
Relay
ON

ii ) Under Voltage Function


R
Y
B
Hysteresis
Under Voltage Limit

Relay
ON

>U LED ON

<U LED ON

Ordering Information

Case Dimensions
71 mm

70 mm

20 mm
85 mm

45 mm

Front

Side

20 mm
30 mm 20 mm 20 mm

MODEL DESCRIPTION
MX210 - 415V

3-Phase 380-415V AC
Single-Phase 220-240V AC
45-65Hz

MX 210

MX 180A
Over Voltage Relay

MX 200A
Under & Over Voltage Relay

Voltage Relay

MX 160A
Under Voltage Relay

MX200A
MK180A
MK160A
Features
Electronic monitoring relay
Voltage monitoring for single
3-phase system

Phase failure monitoring


Adjustable voltage limit
Adjustable delay time
Indicators for voltage fault
Indicators for power and output ON
ANSI Code : 27, 47, 59

Product Description
MX160A, MX180A & MX200A are single
or 3-phase monitoring relays. The relays
are designed for application where it
required to maintain the voltage within
set limits. A built-in adjustable time delay
prevents nuisance tripping.

Technical Data
SETTING RANGES

Single Phase

HYSTERESIS

Phase-to-phase voltage : 380 V AC 20%


400 V AC 20%
415 V AC 20%
Phase-to-neutral voltage : 220 V AC 20%
230 V AC 20%
240 V AC 20%
Frequency range
: 45 to 65 Hz
Max. power consumption : 3 VA

Input Connections
For 3-phase model

: Phase L1, L2, L3 to


pin 5, 6, & 7

Neutral to pin 11
For single-phase model : Phase L to pin 5, 6 &
7***

Neutral to pin 11

Lower voltage limit *


Upper voltage limit **
Delay time, T

: 78% - 98%
: 102% - 122%
: 0.1 - 10s

1% of rms - value

INDICATORS

Power supply ON
Output ON
Under voltage limit (U<) *
Over voltage limit (U>) **

ENVIRONMENTAL CONDITIONS

Temperature
Humidity

OUTPUT CONTACTS

Rated voltage
: 250 V AC
Contact rating
: 5 A
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

: Green indicator
: Red indicator
: Red indicator
: Red indicator

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

MECHANICAL
Mounting

: Circular 11-pin plug-in


socket
Dimension (mm)
: 35(w) x 80(h) x 72.5(d)
Approximate weight : 0.3 kg

* Applicable to MX160A and MX200A only


** Applicable to MX180A and MX200A only
*** For single phase connection, short pin 5,6 & 7

MX 200A / 180A / 160A

POWER SUPPLY INPUT


3-Phase System

Voltage Relay

Wiring Diagram
Single-Phase System

3-Phase System

L
N

L3
L2
L1
N
5

9
2

1 11

10

9
2

11

10

Operations Diagram
i ) Over Voltage Function**
Over Voltage Limit
Hysteresis
R
Y
B
Relay
ON

ii ) Under Voltage Function*


R
Y
B
Hysteresis
Under Voltage Limit

Relay
ON

>U LED ON

<U LED ON

Ordering Information

Case Dimensions

MODEL

MX 200A / 180A / 160A

80 mm

72.5 mm
35 mm

FUNCTION
Under
Over
Voltage
Voltage
Monitoring Monitoring

Supply
Voltage
V AC

MX160A - 380

YES

NO

380

MX160A - 400

YES

NO

400

MX160A - 415

YES

NO

415

MX180A - 380

NO

YES

380

MX180A - 400

NO

YES

400

MX180A - 415

NO

YES

415

MX200A - 380

YES

YES

380

MX200A - 400

YES

YES

400

MX200A - 415

YES

YES

415

MX 100
Phase Sequence &
Phase Failure monitoring

MX100
MK50

Voltage Relay

MX 50
Phase Failure monitoring

Features
Electronic monitoring relay
Phase sequence monitoring*
Phase failure monitoring
Plug-in type module
Indicators for power and alarm status
ANSI Code : 47

Product Description
This phase sequence and phase failure
relay is designed for application where the
3-phase supply needs to be continuously
monitored for proper sequencing and
phase loss. Commonly used to protect a
3-phase motor.

Technical Data
POWER SUPPLY INPUT

INDICATORS

Phase-to-phase voltage : 230 V AC 20%



: 400 V AC 20%
Frequency range
: 45 to 65 Hz
Max power consumption : 3 VA
Input connections
: Phase L1 to pin 5
Phase L2 to pin 6
Phase L3 to pin 7
Neutral (optional) to
pin 11

Power supply ON
Output ON

OUTPUT CONTACTS

MECHANICAL

Rated voltage
: 250 V AC
Contact rating
: 5 A
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

Mounting

: Green indicator
: Red indicator

ENVIRONMENTAL CONDITIONS
Temperature
Humidity

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

MX 100 / 50

: Circular 11-pin plug-in


socket
Dimension (mm)
: 35(w) x 80(h) x 72.5(d)
Approximate weight : 0.3 kg

Voltage Relay

Wiring Diagram
Example 2

Example 1
L3
L2
L1

L3
L2
L1
N

3~

3
2

11

3~

8
9

10

11

10

Function Table
Condition Pin 5

Pin 6

Pin 7

Relay

Remark

L1

L2

L3

ON

System healthy

Loss

L2

L3

OFF

Phase failure

L1

Loss

L3

OFF

Phase failure

L1

L2

Loss

OFF

Phase failure

L2

L1

L3

OFF

Sequence fault*

L3

L2

L1

OFF

Sequence fault*

* Applicable to MX100 model only

Ordering Information

Case Dimensions

80 mm

MX 100 / 50

72.5 mm
35 mm

MODEL

DESCRIPTION

MX100 - 230

Auxiliary voltage 184~276 V AC

MX100 - 400

Auxiliary voltage 320~480 V AC

MX50 - 230

Auxiliary voltage 184~276 V AC

MX50 - 400

Auxiliary voltage 320~480 V AC

Features
Reverse power monitoring
3-phase, 3 or 4-wire system
Adjustable reverse power setting

Reverse Power Relay

RPR415A
Adjustable tripping time delay
Indicators for auxiliary power, trip delay
and trip status
Test button
ANSI Code: 32

Product Description
RPR 415A relay is a directionally controlled
timing relay used to protect AC generators
from motoring. When such condition
occurs and the reverse current exceeded
the customer adjustable preset limit for a
predetermined delay time, the trip relay
operates to disconnect the circuit.

Technical Data
INPUT

SETTING RANGES

ENVIRONMENTAL CONDITIONS

Rated Phase-neutral voltage : 220V to 240V AC


Rated Phase-phase voltage : 380V to 415V AC
Rated frequency
: 50 or 60 Hz
Rated current (I n)
: 5A
Burden
: < 0.3 VA at In
Thermal withstand : 1.2 x U n , 2 x I n continuous

: 1.2 x U n , 10 x I n for 3 sec
Power consumption
: 3 VA maximum

Range

Temperature : -5C to +55C


Humidity
: 56 days at 93% RH and 40C

non-condensing

OUTPUT CONTACTS

MECHANICAL
ACCURACY
Protection thresholds Hysteresis : 3%
Delay time
: 1%


: 0-0.5s, 15%,

40ms minimum.
Measurements : 0.5s and above, 3% : 3%

INDICATORS
Auxiliary supply
Delay
Trip

: Green indicator
: Red indicator
: Red indicator

Mounting
: DIN rail
Dimension (mm)
: 71(w) x 85(h) x 70(d)
Approximate weight : 0.3 kg

RPR 415A

Rated voltage
: 250 V AC/DC
Contact rating
: 5 A
Expected electrical life: 100,000 operations at
rated current
Expected mechanical life: 5 x 106 operations

: 2% to 20% reverse current


with 1% Hysteresis
Time delay : 0 sec to 20 sec
3-Phase 4-wire (star) or 3-Phase 3-wire (delta)

Reverse Power Relay

Typical Application Diagram


I

L1

S1

L2

L1

Generator

3~

L3

S1

L2
L3

3~

415V

240V
1

R1
8

10

11

12

S2

S1

13

14

10

11

12

S2

S1

13

14

3-Phase 3-wire system

Case Dimensions
70 mm

71 mm
20 mm
85 mm

45 mm

Side

20 mm
30 mm 20 mm 20 mm

Ordering Information
MODEL DESCRIPTION

RPR 415A

RPR415A

R1

3-Phase 4-wire / single-phase system

Front

380-415Vpp AC / 220-240Vpn AC, 45-65Hz

Generator

Features
Reverse power monitoring
3-phase-4-wire system
Adjustable reverse power setting

Reverse Power Relay

RPR415
Adjustable tripping time delay
Indicators for auxiliary power, trip delay
and trip status
Test button
ANSI Code : 32

Product Description
The RPR 415 relay is a directionally
controlled timing relay used to protect
AC generators from motoring. When
such a condition occurs and the reverse
current exceeded the customer adjustable
preset limit and the current persists for a
predetermined delay time, the trip relay
operates to diconnect the circuit.

Technical Data
INPUT

INDICATORS

Rated voltage (Un) : 380 ~ 440 V AC


Rated current (I n) : 5 A
Rated frequency
: 50 or 60 Hz
Overload
: 1.2 x U n , 2 x I n continuous

1.2 x U n , 10 x I n for 3 sec

Auxiliary supply
Delay
Trip

OUTPUT CONTACTS

Temperature : -5C to +55C


Humidity
: 56 days at 93% RH and 40C

non-condensing

Rated voltage
: 250 V AC/DC
Contact rating
: 5 A
Expected electrical life: 100,000 operations at
rated current
Expected mechanical life: 5 x 106 operations

Range
Time delay

: 2% to 20% reverse current with


1% Hysteresis
: 0 sec to 20 sec

ENVIRONMENTAL CONDITIONS

MECHANICAL
Mounting
: Panel mounting
Dimension (mm)
: 96(w) x 96(h) x 142(d)
Approximate weight : 0.8 kg

RPR 415

SETTING RANGES

: Green indicator
: Red indicator
: Red indicator

Reverse Power Relay

Typical Application Diagram


DIRECTION OF CURRENT FOR OPERATION
P1

L1

S1

L2
L3
N

COM NC

10

11

13

14

15

16

NO

12

Case Dimensions
142 mm
132 mm

Front

Ordering Information
MODEL DESCRIPTION
RPR415

Auxiliary voltage 380 ~ 440 V AC

Side

91.0 0.5 mm

Panel Cutout

91.0 0.5 mm

96 mm

96 mm

RPR 415

Power Factor Regulator

PFR140
PFR120
PFR80
PFR60
Features

Microprocessor based intelligent auto switching


control
Automatic C/K and rated step adjustment
Automatic CT polarity correction
Display of power factor, current & total harmonic
distortion of current
Programmable sensitivity
Last step can be used as alarm/fan output
Under/over voltage alarm, under/over compensate
alarm & high harmonic distortion alarm
User-friendly setting
Complies with IEC 61000-6-2 standard

Technical Data
CURRENT INPUT

Current Supply voltage : 220~240 V AC /


380~415 V AC
Operating Limits
: -15% + 10%
Consumption
: 10 VA max
Rated frequency
: 50 Hz or 60 Hz

Rated current ( In )
Operating Limits
Rated Frequency

OUTPUT CONTACTS
Numbers of outputs

: 6 / 8 / 12 / 14 ( PFR60
/ PFR80 / PFR120 /
PFR140 )
Rated voltage
: 250 V AC
Contact rating
: 5A
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations
Max current for the
common terminals
: 12 A continuous

ENVIRONMENTAL CONDITIONS
:5A
: 0.05 A to 6.5 A
: 50 Hz or 60 Hz

Temperature
Humidity

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

CONTROL RANGE

MECHANICAL

Power factor setting : 0.8 Ind - 0.8 Cap


C/K setting
: 0.03 - 1.20 / Automatic
Switching sensitivity : 5 - 600 s/step
Reconnection time for
same step
: 5 - 240 s
THD threshold
: 0.20 - 3.00 ( 20% - 300% ) /
OFF
Switching Program : Automatic / Automatic
Rotate / 4-quadrant /
Manual
Rated step coefficient : 0 / 1 / 2 / 3 / 4 / 5 / 6 / 8 /
12 / 16

( Automatic if C/K set to
Auto )

Mounting
: Panel mounting
Dimension (mm)
: 144(w) x 144(h) x 90(d)
Enclosure protection : IP54 at the panel
Approximate weight : 1.2 kg

PFR 140 / 120 / 80 / 60

RATINGS AUXILIARY POWER SUPPLY

14
15
16
17
18
19
20
21
22
23
24

P1
P2

13

AUX
VOLTAGE

CURRENT
/5A
11
12
13
14

1
2
3
4
5
6
7
8
9
10

1
2
3
4
5
6
7
8
9
10
11
12

14
15
16

220~240 V AC

13

Power Factor Regulator

MAIN
N L3 L2 L1

380~415 V AC

Power Factor Regulator

Typical Application Diagram

AUX
VOLTAGE

For 220~240 V AC Model Only

FUSE

K14

K13

K2

K1

LOAD

Ordering Information

Case Dimensions

DESCRIPTION

PFR60 - 415 - 50

6 Steps, 50 Hz system, auxiliary voltage 380~415 V AC

PFR80 - 415 - 50

8 Steps, 50 Hz system, auxiliary voltage 380~415 V AC

PFR120 - 415 - 50

12 Steps, 50 Hz system, auxiliary voltage 380~415 V AC

PFR140 - 415 - 50

14 Steps, 50 Hz system, auxiliary voltage 380~415 V AC

PFR60 - 220 - 50

6 Steps, 50 Hz system, auxiliary voltage 220~240 V AC

PFR80 - 220 - 50

8 Steps, 50 Hz system, auxiliary voltage 220~240 V AC

PFR120 - 220 - 50

12 Steps, 50 Hz system, auxiliary voltage 220~240 V AC

PFR140 - 220 - 50

14 Steps, 50 Hz system, auxiliary voltage 220~240 V AC

PFR60 - 415 - 60

6 Steps, 60 Hz system, auxiliary voltage 380~415 V AC

PFR80 - 415 - 60

8 Steps, 60 Hz system, auxiliary voltage 380~415 V AC

PFR120 - 415 - 60

12 Steps, 60 Hz system, auxiliary voltage 380~415 V AC

PFR140 - 415 - 60

14 Steps, 60 Hz system, auxiliary voltage 380~415 V AC

PFR60 - 220 - 60

6 Steps, 60 Hz system, auxiliary voltage 220~240 V AC

PFR80 - 220 - 60

8 Steps, 60 Hz system, auxiliary voltage 220~240 V AC

PFR120 - 220 - 60

12 Steps, 60 Hz system, auxiliary voltage 220~240 V AC

PFR140 - 220 - 60

14 Steps, 60 Hz system, auxiliary voltage 220~240 V AC

Front

90 mm
76 mm

Side

138 mm

Panel
Cutout

138 mm

PFR 140 / 120 / 80 / 60

MODEL

144 mm

144 mm

Features
Microprocessor based intelligent auto
switching control
Automatic C/K and rated step
adjustment

Power Factor Regulator

PFR96
PFR96P
Automatic CT polarity correction
Display of power factor & current
Programmable sensitivity
Last step can be used as alarm/fan output
Under/over voltage alarm, under/over
compensate alarm

For PFR 96

For PFR 96P

User-friendly setting

For single-phase system

For 3-phase system

Complies with IEC 61000-6-2 standard

Technical Data
RATINGS AUXILIARY POWER SUPPLY

CURRENT INPUT

Model PFR96

Model PFR96P
Operating Limits
Consumption
Rated frequency

Rated current ( In )
Operating Limits
Rated frequency

: 110 ~ 120 V AC /
220 ~ 240 V AC
: 380 ~ 415 V AC
: -15% + 10%
: 10 VA max
: 50 Hz or 60 Hz

OUTPUT CONTACTS
: 6
: 250 V AC
: 5A
: 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations
Max current for the
common terminals
: 12 A continuous

CONTROL RANGE
Power factor setting
C/K setting
Switching sensitivity
Reconnection time for
same step
Switching Program

: 0.8 Ind - 0.8 Cap


: 0.03 - 1.20 / Automatic
: 5 - 600 s/step

: 5 - 240 s
: Automatic / Automatic
Rotate / 4-quadrant /
Manual
Rated step coefficient : 0 / 1 / 2 / 3 / 4 / 5 / 6 / 8
/ 12 / 16

( Automatic if C/K set to
Auto )

ENVIRONMENTAL CONDITIONS
Temperature
Humidity

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

MECHANICAL
Mounting
: Panel mounting
Dimension (mm)
: 96(w) x 96(h) x 90(d)
Approximate weight : 0.6 kg

PFR 96 / 96P

Numbers of outputs
Rated voltage
Contact rating
Expected electrical life

:5A
: 0.15 A to 6.5 A
: 50 Hz or 60 Hz

Diagram 1 - For model PFR96

Diagram 2 - For model PFR96P

MAIN
N L3 L2 L1

MAIN
N L3 L2 L1

7
6
5

6
VOLTAGE
220 V AC /
110 V AC

4
P1

3
2

P2

5
4
3
2

CURRENT
/5A

16

14

13

12

11

P1

10

P2

FUSE

15

FUSE

6
VOLTAGE
380~415
V AC

CURRENT
/5A

Power Factor
Regulator

FUSE

Power Factor
Regulator

Power Factor Regulator

Typical Application Diagram

5
4
3
2
1

16
15
14
13
12
11
10
9

FUSE

K5

K1

LOAD

K6

K5

K1

K6

LOAD

Ordering Information

Case Dimensions

MODEL

DESCRIPTION

PFR96 - 220 - 50

6 Steps, for 50 Hz system, auxiliary voltage 220~240 V AC

PFR96 - 220 - 60

6 Steps, for 60 Hz system, auxiliary voltage 220~240 V AC

PFR96 - 110 - 50

6 Steps, for 50 Hz system, auxiliary voltage 110~120 V AC

PFR96 - 110 - 60

6 Steps, for 60 Hz system, auxiliary voltage 110~120 V AC

PFR96P - 415 - 50

6 Steps, for 50 Hz system, auxiliary voltage 380~415 V AC

PFR96P - 415 - 60

6 Steps, for 60 Hz system, auxiliary voltage 380~415 V AC

96mm

96 mm

Front

90 mm
70 mm

Side

Panel
Cutout

91.0 0.5 mm

PFR 96 / 96P

91.0 0.5 mm

Features
2 inch, 64 x 128 dot matrix LCD display
with back lighting
Three phase and single phase detection
of reactive power
12 (or 8 for 8 step model) output with
two additional

Power Factor Regulator

PFRLCD
Independent contact for signal alarm
output and fan output
Three phase compensation mode
5 different switching program
Automatic detection of C/K and rated
step value

Measurement Parameters

No Voltage release

Active, reactive, apparent power


Temperature
Phase voltage and phase current
Frequency

Up till 31st order Harmonics


measurement in graphical and table
format

Various configurable alarm settings

Power Factor and Displacement


Power Factor (Cos)

Programmable fan control

Alarm linked signal contact


ModBus-RTU communication

Typical Application Diagram


PFRLCD Connection diagram for 3 Phase 12 Step model

PFRLCD Connection diagram for 1 Phase 12 Step model


LOAD

LOAD

K12

K2

K12

K1

L3

31 30 24 23 14 13 12 11 10 9 8 7 6 5 4 3 2 1 20 21 22

PFR LCD

32 44 43 42 41 40 39 38 37 36 35 34 33
N L
N L1 L2 L3 In Out
AUX
CT1

P2
P1

L1

NRS485
RP
Modbus
P+
-RTU
GND
T1
T2 Thermistor

PFRLCD120P3-230-50

SIG
FAN

1 2 3 4 5 6 7 8 9 10 11 12

FUSE

SIG
FAN

L2

31 30 24 23 14 13 12 11 10 9 8 7 6 5 4 3 2 1 20 21 22

PFR LCD

1 2 3 4 5 6 7 8 9 10 11 12

32 44 43 42 41 40 39 38 37 36 35 34 33
N L
N L1 L2 L3 S1 S2 S1 S2 S1 S2
AUX
CT2
CT3
CT1

P2
P1

P2
P1

L3

L2

P1

P2

SIG
FAN

SIG
FAN

NRS485
RP
Modbus
P+
-RTU
GND
T1
T2 Thermistor

PFRLCD120P1-230-50

PFR LCD

L1

K1

FUSE

FUSE
FUSE

K2

Power Factor Regulator

Technical Data
CURRENT INPUT
(EACH PHASE)
Nominal Current
Operating Limits
Rated frequency

: 5 A rms
: 0.01-10 A rms
: 50 Hz or 60 Hz

VOLTAGE INPUT
(EACH PHASE with respect to neutral)
Nominal Voltage
Operating Limits
Consumption
Rated Frequency
Catagory

: 230 Vrms
: 0 - 277 V L-N
: 0.05 VA
: 50 Hz or 60 Hz
: III

THERMISTOR INPUT
Thermistor Temperature range : 0 100 C

AUXILIARY
Auxiliary Input Voltage Range : 85 - 265 Vrms
Consumption
: 10 VA max
Rated Frequency
: 50 Hz or 60 Hz

OUTPUT CONTACTS
Number of outputs : 14 (model dependent)
Rated voltage
: 250 V AC
Contact rating
: 5A
Expected electrical life : 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

CONTROL RANGE

DISPLAY

Target Power factor

%THDI & %THDV


: 0 500%
Harmonics Resolution : Up till 31st Harmonics
Active power
: 0 3000 W
Reactive power
: 0 3000 VAR
Apparent power
: 0 3000 VA
Voltage
: 0 300 VAC
Current
: 0.00 10.0 A rms
Temperature
: 0 100 C
Frequency
: 45 65Hz
Power Factor
: -1.00 1.00
Displacement Power Factor : -1.00 1.00

: 0.80 Inductive 0.80


Capacitive
C/K setting
: 0.03 1.20 / Automatic
detect
Sensitivity
: 5 - 300s / Step
Reconnection time : 5 240s
Switching program : Automatic/ Manual/
Four-quadrant/
Rotational/ Linear
Rated step coefficient : 0/ 1/ 2/ 3/ 4/ 5/ 6/ 8/ 12/
16/ Fixed
Detection mode
: L1 / L2 / L3 / Max Load /
Three Phase
Fan Setting
: Fixed on / Output On /
Temperature / None
Signal Contact
: Linked to 10 different
programmable alarm /
None

ALARM SETTING RANGE


%THDI
Over Voltage
Under Voltage
Over Current
Under Current
Under Compensate
Over Compensate
*CT Polarity Error
Step Error
Temperature

: 20 - 300% / OFF
: 253 264 V/ OFF
: 195 204 V/ OFF
: 5.50 7.00 A/ OFF
: 0.01 0.15 A/ OFF
: On / OFF
: On / OFF
: On / OFF
: On / OFF
: 36 70 C / OFF

Case Dimensions

144mm

144mm

ENVIRONMENT CONDITIONS
Temperature
Humidity

: -5C to +55C
: 56 days at 93%RH and
40C non-condensing
Pollution Degree
: II
Dielectric Withstand : IEC61010-1
Altitude
: 2000 m

ELECTROMAGNETIC COMPATIBILITY (EMC)


Part 6-2: Generic standards
: IEC61000-6-2
Immunity for industrial
environments
Part 6-4: Generic standards
: IEC61000-6-4
Emission standard for industrial
environments

MECHANICAL
Mounting
: Panel mounting
Dimension (mm)
: 144(w) x 144(h) x 122(d)
Enclosure protection : IP54 at the panel
IP20 at the body
Approximate weight : 1.2 kg
(for three phase model),

1 kg
(for single phase model)

Ordering Information

Front View
122mm
102mm

138mm

138mm

PFR LCD

Side View

Panel Cutout

MODEL

DESCRIPTION

PFRLCD120P3-230-50

12 Step, 3 Phase, 230Vrms, 50Hz Model

PFRLCD80P3-230-50

8 Step, 3 Phase, 230Vrms, 50Hz Model

PFRLCD120P1-230-50

12 Step, 1 Phase, 230Vrms, 50Hz Model

PFRLCD80P1-230-50

8 Step, 1 Phase, 230Vrms, 50Hz Model

PFRLCD120P3-230-60

12 Step, 3 Phase, 230Vrms, 60Hz Model

PFRLCD80P3-230-60

8 Step, 3 Phase, 230Vrms, 60Hz Model

PFRLCD120P1-230-60

12 Step, 1 Phase, 230Vrms, 60Hz Model

PFRLCD80P1-230-60

8 Step, 1 Phase, 230Vrms, 60Hz Model

Annunciator

AN112
AN120
AN128
Features
12, 20 or 28 windows. Replaceable superbright LED modules, with choice of amber or
red illumination
11 Alarm Sequences as per ISA-18.1 standard
Each channel/window fully field
programmable, either from front panel built-in
pushbutton or using PC

Programmable Alarm Annunciator


The AN112/120 series Alarm Annunciator provides ideal solution for all your alarm
system management and requirement. It comes with either 12, 20 or 28 windows,
and due to the use of microprocessor-based design, the alarm annunciator is highly
flexible in terms of functionality and programmability, suitable for all application
and industries.

Tests And Standards

Option of either RS232 or RS485 MODBUS-RTU


communication. Comes with user-friendly
configuration software.
Repeat relay for each window as well as
numerous configurable multifunction output
relays for connection to external equipment to
form alarm management system

Sleep or unattended mode feature is available,


8 KV
for stations not permanently manned
6 KV
4 KV, 5/50ns
Auto-silence and auto-acknowledge features,
4 KV, L to E
with delay settable from 1 255 s
Front: IP41
Enclosure: IP30 Other amount of windows available upon
request.

Electrostatic discharge IEC61000-4-2, Class III, air discharge


Electrostatic discharge IEC61000-4-2, Class III, contact discharge
Electrical fast transient IEC61000-4-4
Surge immunity IEC61000-4-5
Enclosure protection when panel mounted

Technical Data
WINDOW

ALARM SEQUENCES

M, A, R, R-12, F1A, F1M, F2A, F2M, F3A, F3M,


Follower

AUXILIARY POWER INPUT

Fuse protected.
AN1xx-30
: 24-36 V DC or 18-27 V AC.
AN1xx-110
: 88-132 V DC or 64-95 V AC.
Power consumption : AN112: 6 W, AN120: 8 W,
AN128: 10W

ALARM CONTACT INPUTS


Opto-isolated inputs
AN1xx-30
AN1xx-110
Input current

: 24-36 V DC
: 88-132 V DC
: 3 mA typical

OUTPUT CONTACTS
Repeat relays

: Potential free for each


alarm point.
5 A at 250 V AC, 3 A at 30 V
DC. Resistive load.
AUX1-AUX3,
RBACK, SSP
: 5 A at 250 V AC, 5 A at 30 V
DC. Resistive load.

TERMINALS

Wire size : 28-14 AWG. ( 0.08mm2 to 2.5mm2 )



Removable screw type terminal block

COMMUNICATION

Hardware interface : AN1xx - xx - x - A: RS232



AN1xx - xx - x - B : Isolated
RS485
Protocol
: Modbus - RTU
Baud rate
: 300 to 57600

ENVIRONMENT CONDITIONS

Operation temperature: -20 to 60C


Storage temperature : -20 to 80C
Humidity
: 0 - 95% RH,
non condensing

MECHANICAL

Mounting
Approximate weight

: Panel Mounting
: AN 112 : 2.4 kg
AN 120 : 3.1 kg
AN 128 : 3.5 kg

AN 112 / 120 / 128

Window Dimension : 50 x 30 mm.


Type: White translucent lens.
Colours: Red, Amber. Coloured
by field replaceable LED
module.
Windows Flash Fast: 1.4 Hz
( 0.4s on, 0.4s off ),
Slow: 0.45 Hz
( 1.1s on, 1.1s off ),
Intermittent:
( 0.4s on, 1.8s off )

4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1
C12
C11
C10
C8
C7
C6
C5
C9
C4

- +

- +

- +

- +

- +

- +

- +

- +

- +

D- D+

Sleep
1 2

RS232

RS485
1 2 3 4

Mute
Ack
Reset
Test
1Rst
Dis

Power

Button

1 2 3

1 2 3 4 5 6 7

- +

Power
Ground - +

RBCK

SSP

- +

+ -

- +

Annunciator

Typical Connection Diagram

AUX3 AUX2 AUX1

C1
C2
C3
1 2 3 4 1 2 3 4 1 2 3 4

Relay output
1 2 3 4 5 6 7 8 9 10

Case Dimensions
132 mm

237 mm

132 mm

237 mm

277 mm

AN112 Side

AN128 Front

132 mm

237 mm

246 mm

157 mm

126 mm

AN112 Front

AN128 Side

217 mm

186 mm

132 mm

1.5 mm

206 mm

AN 112 / 120 / 128

AN120 Front

AN120 Side

Bottom

Ordering Information
Order code:

AN1

A: RS 232 communication
B: RS 485 communication

0: without repeat relays


1: with repeat relays
Power Supply: 30, 110 V DC
Number of Windows: 12, 20, 28
For example: 12 windows, 30 V DC, with repeat relays, RS232 communication:

AN112-30-1-A

Annunciator

AL24
Features
Alarm monitoring
Outputs for lamp and horn
Indicators for output contacts

Product Description
Alarm relay provides LED indication and output
contact signalling when there is alarm signal
received. The alarm relay consist of alarm input,
alarm accept, alarm reset, lamp test controlled
input and 2 relay contacts. Red LED indication
for relays. The relay 1 (LED) flashes and the relay
2 (LED) turned on when alarm signal is received.

Technical Data
INPUT

INPUT TYPE

ENVIRONMENTAL CONDITIONS

Auxiliary input
: 24 V DC 5%
Max power consumption : 2 W

Dry contact

Temperature
Humidity

: -5C to +55C
: 56 days at 93% RH and
40C non-condensing

OUTPUT CONTACTS
INPUT CONNECTION
Alarm input
Aalrm accept
Lamp test
Reset
Common

: Pin 7
: Pin 4
: Pin 8
: Pin 5
: Pin 6

Rated voltage
Contact rating
Expected electrical life

: 250 V AC
: 5 A
: 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

MECHANICAL
Mounting

: Circular 11-pin plug-in


socket
Dimension (mm)
: 35(w) x 80(h) x 72.5(d)
Approximate weight : 0.2 kg

INDICATORS
Auxiliary supply
Relay 1 (Lamp)
Relay 2 (Horn)

: Green indicator
: Red indicator
: Red indicator

AL 24

Annunciator

Operation Diagram
Auxiliary supply (pin +2, -10)
Alarm
(pin 7, 6)
Alarm accept (pin 4, 6)
Reset
(pin 5, 6)
Relay 1
(Lamp)
Relay 2
(Horn)
Lamp test
(pin 8, 6)

Case Dimensions
LAMP
TEST

ALARM

RESET

ALARM
ACCEPT

Connection Diagram

AL 24

5
4
NO

3
2

RY1

Alarm Relay

RY2

11

9 NO

80 mm

10

COM COM

AUXILIARY

Power Supply ( DC only )

RELAY 1
RELAY 2

72.5 mm
35 mm

Ordering Information
MODEL DESCRIPTION
AL 24

Auxiliary voltage 24 V DC

AL 24

Features
Microprocessor based numerical relay
Thermal overload
Overcurrent

Motor Protection Relay

MPR500
Undercurrent
Unbalance
Phase loss
Phase sequence
Earth fault
Prolonged starting/stall rotor
2 voltage-free output contacts
ANSI Code : 37, 46, 47, 49, 50P, 50G

Technical Data
CT RATINGS

Rated current
: 2-10A
Rated frequency : 50 Hz or 60 Hz
Burden
: <0.3 VA at rated current
Thermal withstand : Continuous : 2x max rated

45s : 6x max rated

1s : 10x max rated

BINARY INPUT

Rated input voltage


: 12V (Supplied
internally)

AUXILIARY SUPPLY

Model MPR 500-240AD : 85 ~ 265 V AC


110 ~ 370 V DC
Supply frequency
: 50 or 60 Hz
Maximum power
consumption
: 3 VA typical

Rated voltage
Contact rating
Expected electrical life

: 250V AC
: 5 A
: 100,000 operations at
rated current
Expected mechanical life : 5 x 106 operations

Thermal Overload
time constant, t6X
: 1 40s.

Step 0.1s for 1-10s,

step 1s for 10-40s.
Short circuit, I>>
: off, 2 12 x IB.
Step 1 x IB
Short circuit delay time, t>> : 0 25s.

Step 0.1s for 1-10s,

step 1s for 10-25s.
Undercurrent, I<<
: off, 20 90% IB.
Step 1%
Undercurrent delay time, t<< : 0 60s.

Step 0.1s for 1-10s,

step 1s for 10-60s.
Unbalance,
: off, 10 50%.
Step 1%
Unbalance delay time, t
: 0 25s.

Step 0.1s for 1-10s,

Step 1s for 10-25s.
Earth fault, I0
: off, 10 60% IB.
Step 1%
Earth fault delay time, t0
: 0 25s.

Step 0.1s for 1-10s,

step 1s for 10-25s.
Phass loss
: < 500ms
Phase sequence
: < 200ms

Prolonged starting/
stalled rotor, IS
: off, 2 12 x IB.
Step 0.1 x IB
Prolonged starting
time delay, tStart
: 0 60s.

Step 0.1s for 1-10s,

step 1s for 10-60s.
Stalled rotor delay time, tStall : 0 60s.

Step 0.1s for 1-10s,

step 1s for 10-60s.

INDICATORS

Run
: Green indicator
Trip/Pickup
: 7-segment display
and red indicator
Thermal
: Yellow indicator

ENVIRONMENTAL CONDITIONS

Temperature : -5C to +55C


Humidity
: 56 days at 93% RH and 40C
non-condensing

MECHANICAL

Mounting
: Panel mounting
Dimension (mm)
: 96(w) x 96(h) x 110(d)
Approximate weight : 0.8 kg

MPR 500

OUTPUT CONTACTS

SETTING RANGES

Motor Protection Relay

Typical Application Diagrams


L3 L2 L1
F1

F2

F4
F1

F3

MPR 500

K1

15

NO

NC

13

COM

14

COM

11

NC

COM

COM

R2

16

S2

12

Stop

S1
K1

Start

NC

NO

Binary
input

H1

K1

R2

S2

Stop

S1
Start

NC

NO

H1

K1

K1

Single-Phase Motor
(Earth fault, phase sequence and phase loss detection off)

2 hour

1 hour

1 hour

30 min
20 min

30 min
20 min

10 min

10 min

5 min

5 min

3 min
2 min

3 min
2 min

t6x

96 mm

96 mm

time

2 hour

1 min
40 sec
30 sec
20 sec

40s
30s
20s

1 min
40 sec
30 sec
20 sec

10 sec

10s

10 sec

40s
30s
20s

5 sec

5s

5 sec

10s

2s

3 sec
2 sec

1s

1 sec

1.05

5
3
4
(a) With 0% thermal capacity (cold start)

16

R1

Case Dimensions

time

15

Aux

Block R1/
Reset/
Trip

Thermal Tripping Curve

NO

Motor with higher full load current using external CT

1 sec

Block R1/
Reset/
Trip

3 sec
2 sec

10

R1

14

13

Binary
input

1
2

11
12

MPR 500

K1
Aux

10

F2

I/IB

t6x

Front

110 mm
100 mm

5s
1.05

2s
1s
2

(b) With prior 50% thermal capacity

Side

I/IB

MPR 500

Ordering Information
MODEL DESCRIPTION
MPR500-240AD

For 50 / 60 Hz system, auxiliary voltage 85 ~ 265 V AC or 110 ~ 370 V DC

Panel Cutout

91.0 0.5 mm

91.0 0.5 mm