Approach Slab Design
Approach Slab Design
LOCATION:
NAME OF STRUCTURE:
TR-4
STA. 57+839
OVERPASS OP4
Input Data
a. Dimensions
3654
L
ts
3654 mm
300 mm
2754 mm
S
b. Material data
fc '
28 MPa
fy
414 MPa
Density of concrete
0.90
db
20 mm
Ratio
0.85
Effective depth
240 mm
cc
Width of member
1000 mm
1.384 m
7.200 kN/m
wDL
7.200 kN/m
0.30
P
OL
72.000 kN
1.25
PLL+I
84.523 kN
a. Dead load
MDL = wDL S2 / 8
MDL
6.826 kN m
b. Live load
MLL+I
MLL+I =
58.194 kN m
24 kN/m3
c. Design data
50 mm
Load Analysis
a. Distribution width (main reinforcement parallel to traffic)
E
1.219 + 0.06 S
<
2.100 m
= 0.300 x
24
= 15.24 /
S + ###
= 0.387
= P (1 + I) OL / E
use
Design Moment
= PLL+I S / 4
+ 1.67
MLL+I
MU
135.213 kN m
Required Reinforcement
a. Cracking moment
Modulus of rapture
fr
Moment of inertia
Ig
Distance
Cracking moment
yt
Mcr
= 0.623 fc'
= b ts3 / 12
= ts / 2
= fr Ig / yt
fr
Ig
yt
Mcr
49.449 MPa
1.2Mcr =
59.339 MPa
3.297 MPa
0.00225 m4
0.150 m
0.85 fc'
min
bal
max
= 0.75 bal
fy
1 -
2 (1.2Mcr)
0.00283
bal
0.02891
max
0.02169
b d2 (0.85 fc')
2 Rn
2.608 MPa
AS
= bd
1605.5 mm2
Ab
= 0.25 db2
314.2 mm2
Spacing of bars
sp
= Ab b / AS
fy
150
mm center to center
0.85 fc'
AS sup =
0.00669
195.68 mm
2094.4 mm2
c. Distribution reinforcement
Distribution Reinforcement shall be placed transverse to the main steel reinforcement in the bottom of all
slabs to provide for the lateral distribution of concentrated live loads.
For main reinforcement parallel to traffic,
% distribution
% distribution
= ### /
50 %
S
use % distribution =
=
ddr
Adr
201.1 mm2
sp
290 mm
dT/S
ATS
113.1 mm2
AS T/S =
sp
=
264.6 mm2
Spacing of rebars
sp
= % distribution x AS sup
33.1 %
AS dr
AS dr
= 33.1 %
= Adr b / AS dr
694.1 mm2
16 mm
Minimum area for T/S reinforcement (1/8 in 2 per foot in each direction)
sp
Spacing of rebars
= ATS b / AS T/S
Use 12 temperature and shrinkage bars spaced at
12 mm
427 mm