Operating Instructions en
Operating Instructions en
SLA
Operating instructions
Original
Com. no.
..............................................
Pos. ...............................
Operator
...............................................................................................................................................
0639-990/22j
2010.07
Operating instructions
SLA
Table of contents
1
General remarks..................................................................................................4
1.1 Target group........................................................................................................4
1.2 Where to keep these instructions.......................................................................4
1.3 Adresses.............................................................................................................4
Safety........................................................................................................................5
2.1 Appropriate use..................................................................................................5
2.2 Safety notices.....................................................................................................5
2.3 Safety regulations...............................................................................................5
2.3.1 Principles...............................................................................................5
2.3.2 Service..................................................................................................6
2.3.3 Safety devices.......................................................................................6
2.3.4 Malfunctions..........................................................................................6
2.3.5 Accessories/Spare parts.......................................................................6
2.3.6 Sliding wings and fixed side panels.......................................................6
2.3.7 Foreign wing systems............................................................................6
Commissioning........................................................................................................7
3.1 Sequences..........................................................................................................7
3.2 Adhesive labels...................................................................................................8
3.2.1 Rating plate...........................................................................................8
3.2.2 Service sticker.......................................................................................9
3.2.3 Logo sticker...........................................................................................9
3.3 Final checking.....................................................................................................9
4 control..................................................................................................................10
4.1 Terminals/Power plugs......................................................................................10
4.2 Connections/Entries..........................................................................................10
4.3 Operating- and signalling elements..................................................................10
5 Fuctions (Software).......................................................................................... 11
5.1 Main functions................................................................................................... 11
5.1.1 General................................................................................................ 11
5.1.2 Operating modes.................................................................................12
5.1.3 Reset...................................................................................................12
5.2 Auxiliary functions.............................................................................................13
5.2.1 Operational characteristics in the event of a mains failure without
emergency battery BATPA...................................................................13
5.2.2 Operational characteristics in the event of a mains failure with emergency battery BATPA...........................................................................14
5.2.3 Automatic locking................................................................................15
5.2.4 Manual locking....................................................................................16
5.2.5 Mecanical emergency opening MENO................................................16
5.3 Paratmeter settings...........................................................................................17
5.3.1 Settin-up procedure in special conditions............................................17
5.4 Settings.............................................................................................................18
5.4.1 Presettings with DIP-Switch................................................................18
5.4.2 Settings with adjusting trimmers..........................................................18
5.4.3 LED.....................................................................................................19
5.4.4 Priorities..............................................................................................19
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 2 of 46
Operating instructions
SLA
6
Control..................................................................................................................20
6.1 Key-operated program switch...........................................................................20
6.2 D-BEDIX (option)..............................................................................................21
6.2.1 Keys....................................................................................................21
6.2.2 Symbols...............................................................................................21
6.2.3 Operating modes.................................................................................22
6.2.4 Display of the door position.................................................................22
6.2.5 Menu level...........................................................................................23
6.2.6 Priority of the parameters....................................................................23
6.2.7 Parameter setting only by authorized persons....................................23
6.2.8 Setting examples.................................................................................24
6.2.9 Error display........................................................................................25
6.3 KOMBI-D-BEDIX (option).................................................................................26
6.4 Locking/Manual unlocking (option)...................................................................27
7 service....................................................................................................................28
7.1 Service for pedestrian doors.............................................................................29
7.2 Toothed belt ZARI.............................................................................................30
8
Troubleshooting................................................................................................31
8.1 With key program switch...................................................................................31
8.2 On control unit STERE.....................................................................................31
8.3 Malfunction.......................................................................................................32
8.4 Error display with D-BEDIX / KOMBI-D-BEDIX................................................34
8.4.1 Software and processor errors............................................................34
8.4.2 Power supply errors............................................................................34
8.4.3 Overvoltage errors...............................................................................34
8.4.4 Hardware errors..................................................................................35
8.4.5 Accessories errors...............................................................................35
8.4.6 Mounting and setting errors.................................................................36
8.4.7 Specific BAT-NOT errors.....................................................................36
8.4.8 Operative messages (informative)......................................................36
Shut-down..............................................................................................................37
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 3 of 46
SLA
Operating instructions
General remarks
The following documents are associated with this installation:
Operating instructions
0639-990/22
onto the installation
Operator manual
0639-991/02
by the operator
Control booklet
0639-991/12
onto the installation
The present instructions contains all instructions for commissioning, operation, service
(maintenance/checking) as well as troubleshooting and are the basis which guarantees a
faultless and safe operation of the installation.
They must be completely read and understood before starting the work.
1.1
Target group
All the work described in the present instructions must only be carried out by competent
specialists!
Competent specialists are persons who, based on their professional training and experience, have sufficient knowledge in the field of powered windows, doors and gates.
They are sufficiently familiar with the relevant federal regulations for work protection and
accident prevention, with the guidelines and generally recognized rules applicable for this
field of technology which enables them to evaluate if powered windows, doors and gates
can be safely operated.
Only the trained experts of the manufacturer or the supplier are counted among these
persons.
1.2
1.3
Adresses
Distribution agent/
After-sales service
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 4 of 46
Operating instructions
SLA
Safety
2.1
Appropriate use
The door drive mechanism SLA has been exclusively designed for operating sliding
wings. Any other use beyond these application limits is deemed inappropriate and inadmissible!
In the event of an inappropriate use of this system, the safety of the user may be jeopardized. The manufacturer declines all responsibility for any resulting damages or injuries.
2.2
Safety notices
The present instructions uses the following symbols and notes in order to point out certain
residual dangers:
Warning:
Involving danger to life and limb.
Attention:
A situation where material could be damaged or the function impaired.
Note:
Hints which facilitate the work.
2.3
Safety regulations
2.3.1
Principles
The installation has been calculated, designed and manufactured on the basis of the
latest state-of-the-art technology and the generally recognized safety-relevant rules and
regulations. It may only be operated if it is in perfect condition, taking into account the
specifications of the present manual. Any use beyond the defined application limits is
inadmissible!
The installation is to be operated and maintained in such condition that the safety is
guaranteed at all times. An integral part of this condition is the appropriate use, the
compliance with the operating conditions prescribed by the manufacturer, as well as the
regular service (maintenance/checking).
In order not to create any dangerous squeezing and shearing points, no structural modification must be made within the door surroundings, without prior authorization from
Kaba Gilgen. Furthermore, it is important that no objects (such as furniture, pallets, etc.)
be placed in the vicinity of the door.
Protection of the main and secondary closing edgeaccording to DIN 18650 (see Risk
assessment for an automatic sliding door P 01.02.01).
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 5 of 46
Operating instructions
SLA
2.3.2
Service
In order to guarantee the safety of the users at all times, the installation must be checked
with regard to its safe condition before the first commissioning and during normal operation, at least once a year, by a competent specialist. The correct maintenance/checking
must be confirmed by entering the date and signature into the control booklet.
2.3.3
Safety devices
It is inadmissible to bypass, shunt or disable the safety devices. Any defective safety devices may not be disconnected in order to be able to continue the operation of the installation.
2.3.4
Malfunctions
If any malfunctions occur which might be detrimental to the safety of the users, the installation must be immediately taken out of operation. It may only be taken back into operation after the malfunction has been repaired and all danger eliminated.
2.3.5
Accessories/Spare parts
A safe and reliable function of the installation can only be guaranteed if it is operated with
the original Kaba Gilgen accessories/spare parts. Kaba Gilgen declines all responsibility
for damages resulting from unauthorized modifications of the installation or from the use
of foreign accessories/spare parts.
2.3.6
2.3.7
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 6 of 46
Operating instructions
SLA
Commissioning
Warning:
Prior to commissioning, make sure that the door installation has not been
subject to any modifications which might cause dangerous situations:
Check the door surroundings for any structural changes.
Make sure that no objects (such as furniture, pallets, etc.) have been
placed close to the door.
3.1
Sequences
DIP-Switch
LED
Reset
Adjusting trimmers
Note:
The door must close first. When it opens first: Check right position of belt
coupling(s) or change sense of rotation of the gear motor.
The setting-up procedure is only carried out in the mains-powered mode,
whereas no setting-up is possible in the emergency battery mode because of
the restricted battery power. The control unit STERE is automatically switched off.
If the sliding wing weight exeeds 20 kg, all the setting values remain memorized after a mains failure (no learning run upon start-up).
5. Adjust all the radars and presence detectors according to the respective instructions.
6. Set the desired parameters.
7. Check the function.
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 7 of 46
Operating instructions
SLA
3.2
Adhesive labels
3.2.1
Rating plate
1. If necessary: Fill in any missing data on the rating plate, using a water-resistant felt
tip pen.
2. Detach the rating plate from the A4 format sticker sheet 0635-525 and attach it on
the degreased surface inside the drive unit covering.
Typ: SLA
115/230 VAC
No.: ..............
.....
.....
.....
Num.
Code
Parameter
Drive type
Swing door drive mechanism
Sliding door drive mechanism
Swing and slide door drive mechanism
Folding door drive mechanism
Revolving door drive mechanism
1
2
3
4
5
1
2
3
1
2
3
4
5
0
1
2
5*
1
2
3
0
1
2
3
4
7*
0
1
2
3
4
Ambient temperature
No specification
-15.....+50 C
-15.....+75 C
according to specifications of the manufacturer
1
2
3
4
0639-990/22j
Page 8 of 46
SLA
3.2.2
Operating instructions
Service sticker
1. Attach the service sticker outside on
the drive unit covering, at a place that is
easily visible for the customer.
2. Stick the monthly sticker onto the service sticker, turning the monthly sticker
until the checking date matches the
arrow.
3. Using a water-proof felt tip pen, enter
the year of the next checkup on the
monthly sticker.
3.2.3
Service sticker
.....
Monthly sticker
Logo sticker
1. Attach the logo sticker onto the side
cover (if provided) or onto the drive unit
covering.
3.3
Final checking
Opening elements (field size and response characteristics)
Safety elements (setting and function)
Function of the locking (option)
Check the locking play (1...2 mm per sliding wing)
Check the emergency battery (option)
Check the function of the remaining options
Are there any unusual operating noises?
Compliance with the safety distances at the pinch and shear points (see Risk assessment for an automatic sliding door P01.02.01)?
Adhesive labels filled in?
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 9 of 46
SLA
Operating instructions
control
4.1
Terminals/Power plugs
X100
X101
X102
X103
X105
X110
X113
4.2
X113 X103
Connections/Entries
Control
AUTOMATIC
MANUAL
EXIT
RED. OPEN.
OKI
OKA
Key
Security
Emergency stop
SIR1
SIR2
SI Test
Signalling
Gong
Supply
24 VDC
4.3
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 10 of 46
SLA
Operating instructions
Fuctions (Software)
5.1
Main functions
5.1.1
General
The operating mode NIGHT is automatically active if no program switch is connected to
the control unit or if all contacts are open.
In order to avoid that a change of the operating mode sets off an immediate door action,
1 second will be retarded (de-bounced).
In cases where a key-operated selector switch (or a timer) is connected in combination
with a D-BEDIX, the key-operated selector switch has top priority. In this condition any
change of the operating mode made through the D-BEDIX is memorized and will be
implemented upon revocation (release) or removal of the key-operated selector switch.
For switching over to the operating mode NIGHT (by means of the key-operated selector switch or the timer), the terminal inputs 8 + 9 need to be connected among each
other and the respective element must be connected.
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 11 of 46
SLA
5.1.2
5.1.3
Operating instructions
Operating modes
NIGHT
EXIT
AUTOMATIC
MANUAL
(OPEN)
Reset
A reset causes a stop and unlocks the door, afterwards the drive unit activates a new
setting-up procedure.
A reset can be activated by reset push button on key program switch or on control unit.
Alternatively, to activate reset function, push simultaneously (min 1 second) operating
modes MANUAL and EXIT.
A reset can be activated by the D-BEDIX.
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 12 of 46
SLA
Operating instructions
5.2
Auxiliary functions
5.2.1
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 13 of 46
Operating instructions
SLA
5.2.2
Operational characteristics in the event of a mains failure with emergency battery BATPA
Without mechanical emergency opening MENO
With emergency battery the door continues to function normally during 15...30 minutes
after a power fail. Acceleration and final speed of sliding wings are lower than with power
from network. Emergency battery is whether controlled nor tested. In case of power failure the emergency battery automatically supplies the control unit.
Charged emergency battery in operating mode:
NIGHT
Door is closed and locked
Control unit switches off, wake-up over key
all the others
Door keeps on functioning normally
Discharged emergency battery in operating mode:
NIGHT
Door is closed and locked
Control unit switches off, wake-up over key
EXIT (DIP2 = ON)
Door is opened
or
EXIT locked
Door is closed and locked
AUTOMAT
Door is opened
MANUAL
Door is opened
With mechanical emergency opening MENO
On power fail the drive unit must open due to the escape way functionality. The control
unit only switches off when the emergency battery is discharged. Consequently, when
switching on operating mode NIGHT, the door can be closed the longest possible.
Reaction after power fail in operating mode:
NACHT
Door is closed and locked
Control unit switches off, wake-up over key
Door is opened
EXIT (DIP2 = ON)
or
EXIT locked
Door is opened
AUTOMAT
Door is opened
MANUAL
Door is opened
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 14 of 46
Operating instructions
SLA
5.2.3
Automatic locking
LAVERI
The locking is bistable, e.g. the locking latch is held independently in the locked and unlocked position. The locking state is not confirmed. Correct locking is not checked!
Behaviour in the event of a mains and battery failure:
Door position
closed
open
moving
closed
locked
unlocked
unlocked
locked
manuallly unlocked
manually opened
LAVERI
remains locked
remains unlocked
remains unlocked
is automatically locked upon manual closing
LAVERI-FS
The locking mechanism is mono-stable, i.e. the locking hook is electrically maintained
only in one position, while it automatically drops into the other position in the event of a
mains failure. Whether the locking mechanism is locked or unlocked without mains power
is determined by the way in which the locking hook has been installed.
In function of the desired locking function, the Fail Safe or Fail Secure method must be
selected by means of the DIP Switch on the locking PCB.
unlocked
moving
unlocked
Fail Safe
unlocked
Door remains closed.
unlocked
Door remains open.
Fail Secure
remains locked
Door remains closed.
locked
After being manually
closed, the door is locked.
unlocked
Door slows down to a full
stop.
locked
Door slows down to a full
stop.
After being manually
closed, the door is locked.
0639-990/22j
Page 15 of 46
LED
Operating instructions
SLA
5.2.4
Manual locking
A manual locking is considered to be e.g. a locking installed in the wing profile whose
locking bolt towards the floor. In setting the DIP switch 3 to ON, the drive mechanism is
informed about the manual locking.
Standard sequence with a manual locking
Select operating mode NIGHT, door closes, lock manual locking.
Door is set on operating mode NIGHT, unlock manual locking, slide the door wing open,
after termination of the hold-open time NIGHT the door closes automatically, optionally
lock again or select operating mode AUTOMAT.
Press function after closing
If DIP-Switch 3 is set to ON, no pressing in the operating mode NIGHT (in order to enable
a manual sliding the door wing open).
Special functions
If an opening command is activated for a locked manual locking, the control unit recognises this and stops the door.
When switching from operating mode NIGHT to another one, a slow and short opening
detects whether manual locking has really been unlocked.
When switching from operating mode NIGHT to another one or after activating the key
push-button, the wing stops 140 mm before reaching the open position (to avoid forgotten stuck keys to break off).
After a Key command in the operating mode NIGHT, the sliding wings cover the first
65 mm at slow speed (= in order to check if the door is unlocked). If the manual locking
is locked, an error is displayed.
Note:
By means of the manual locking mechanism, the travel distance (per wing)
can be limited to 65 mm. If a Key command is given, the door waits in this
position until the Key command is de-energized, upon which the door is
closed (pharmacy locking method). No error is displayed.
5.2.5
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 16 of 46
SLA
5.3
Operating instructions
Paratmeter settings
For the setting procedure the following parameters are learned:
Travel distance
When pushing against the close stop piece, first the CLOSED position is reliably recognised. Afterwards the open stop piece is searched out in creeping speed.
Door mass
With a short acceleration the mass of the slide wing(s) is measured. Out of it result the
maximum speed, creepage distance and forces.
Recognition of mechanical emergency opening MENO
In CLOSED position the locking pressure is switched-off for a short time. If door moves
towards the OPEN position, it can be gathered that there is a mechanical emergency
opening MENO.
5.3.1
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 17 of 46
SLA
5.4
Operating instructions
Settings
Operating modes NIGHT, EXIT, AUTOMAT, MANUAL are chosen by the external commanded key-operated program switch or the D-BEDIX.
5.4.1
OFF
ON
Setting
OFF*
ON*
OFF
ON
OFF
ON
OFF*
ON
5
6
OFF
ON
OFF
ON
Function
Sense of rotation GEMO = standard
Sense of rotation GEMO = conversely
On EXIT will be locked
On EXIT will not be locked
without manual locking
with manual locking
Creepage distances standard
without reduced speed in front of Open position
Creepage distance when opening DIN 18650
with reduced speed 200 mm in front of Open position
no BAT-NOT
BAT-NOT controlled
Potentiometer settings active
D-BEDIX parameters active
5.4.2
vo
to
red
0639-990-21---30j_2010.07.indd
Factorysettings
Max.
Function
Closing speed
100...600 mm/s
The maximum value is limited by mass gauging (dynamic forces
1400 N resp. creepage speed 400 N).
Max.
Opening speed
100...600 mm/s
The maximum value is not limited by mass gauging.
Min.
Hold open time (day)
0...45 s
Min.
Reduced opening
10...100 % of the opening range
Material:
PVC-Folie
If the sliding wings are
already in REDUCED-OPEN-Position during
Haftgrund:
Stahlblech
the switch over, they
then moveverzinkt
slowly towards the new position.
Klebstoff:
permanent
Oberflche:
glnzend
Farbe Untergrund:0639-990/22j
weiss
Page
18
of 46
Farbe Schrift:
schwarz
Lieferform:
einzeln
nd.-Nr.
Ge nd
SLA
5.4.3
Operating instructions
LED
LED
uC
Function
error
OKx
Opening
signal
Light barrier/
Emergency
stop
SI
5.4.4
Definition, Remarks
Flashes in 1 second-time = normal operating state.
Lights up = there is at least one mistake.
Lights up = at least one control element (OKA, OKI, Key) is active.
Lights up = at least one safety element (SIR1, SIR2, Not-Stopp) is
active.
Priorities
1. Emergency stop
Door stops immediately and is unlocked.
If door is closed and locked, the locked position is maintained, the push pressure is
cancelled.
If a rubber cable is available and the door is not locked, sliding wings are opened
by the rubber cable.
2. Reset
see chapter parameter settings.
3. Reduced opening
In combination with an opening command (Key, OKI, OKA). The sliding wing(s)
open until set reduced OPEN position.
Reduced opening must the latest be set with the opening signal.
Reduced position is motor held when recognising the rubber cable.
4. Main closing edge HSK (closing direction) incl. light barrier LS
When interrupted, two light barriers invert the motion.
By means of motor current monitoring and/or standstill recognition a reverse of
motion can also be set off.
From the obstacle position, the next closing move is made slowly.
Light barriers/presence sensing devices are tested during the opening move. The
test is repeated until success. Until then, the door remains open.
5. Secondary closing edge NSK (opening direction)
By means of motor current monitoring and/or standstill recognition a stop is activated.
A short disengaging move in closing direction is carried out provided there is no
opening command or reverse. Otherwise the door is stopped for 1 second.
Afterwards it is opened at creepage speed.
6. Key
Unlocks and opens the door. Afterwards the hold-open time NIGHT is awaited until
the door closes and locks.
Key carries out a wake-up.
7. Opening contact inside OKI
Door opens, awaits set hold-open time and closes.
8. Opening contact outside OKA
Door opens, awaits set hold-open time and closes.
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 19 of 46
SLA
Operating instructions
Control
The door opening is performed automatically via radar or manually by means of a pushbutton. The door is automatically closed as soon as the programmed hold-open time has
expired.
6.1
Surface-type mounting
AUTOMATIC
Automatic operation (summer or
winter2 opening width). The installation is not locked.
Reset
Flush type mounting
MANUAL
The installation opens. The sliding
wings are released and can be
shifted by hand.
EXIT
One-way traffic from inside towards the outside (inside = drive unit side). The installation is
locked1 (shop closing switching
mode).
Reset
Provided that the locking mechanism (optional) is installed and DIP2 on OFF.
For switching from summer to winter opening, an external switch can be connected to
the control unit.
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 20 of 46
SLA
6.2
Operating instructions
D-BEDIX (option)
The different operating modes can be
directly enabled by means of the D-BEDIX.
In addition, it provides easy programming of
the most important door settings.
The operating modes, menu settings as well
as possible errors are displayed in a clearly
arranged synopsis.
Only one D-BEDIX can be connected per
door installation.
6.2.1
Keys
C-key (Cancel)
Exit the menu
Invalidate entry
OK-key
Confirm the selection
Confirm the entry
Arrow keys
Navigate within the menus
Short simultaneous actuation of both keys = acces to the menu level
6.2.2
Symbols
Opening width
Winter = reduced opening width
Summer = complete opening width
Operating mode symbols
Show the possible operating modes
(see chapter: operating modes)
Selection frame (active and preselected operating mode)
Shows what has been presently selected.
Selection frame (active operating mode)
Shows what has been presently selected but is still inhibited. A control element with higher priority (e.g. key-operated switch) determines the operating
mode.
Bar (preselected operating mode)
Shows the preselected operating mode.
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 21 of 46
SLA
6.2.3
Operating instructions
Operating modes
With the D-BEDIX, the following operating modes can be selected by means of the corresponding symbols:
AUTOMATIC
Automatic operation (summer or winter opening width). The installation is not
locked.
NIGHT
The installation is locked*. As opening commands, only the key-operated impulse switch is accepted.
OPEN
The installation is opened and remains in the open position.
MANUAL
The installation stops. The sliding wings are released and can be shifted by hand.
EXIT
One-way traffic from inside towards the outside.
The installation is locked* (shop closing switching mode).
6.2.4
>##<
><
<< >>
>> <<
<
>
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 22 of 46
SLA
6.2.5
Operating instructions
Menu level
Short and simultaneous actuation of both arrow keys (=access to the menu level).
Select the desired menu item bymeans of the arrow key.
Confirm by means of the OK key.
Display Description
Winter (reduced opening width)
Summer (entire opening width)
RESET? New setting-up of the drive unit
To
? Hold-open time Day
Tn
? Hold-open time Night
Tvn ? Delay time for switching-over to Night
s
? Reduced opening width (winter)
Vo
? Opening speed
Vc
? Closing speed
VERS ? Software version
CYCLE? Number of opening cycles
LOCK ? Enable the keylock
UNLOC? Disable the keylock
T LCD? Background lighting
Setting range
0...45 s (Standard 1 s)
0...45 s (Standard 5 s)
0...90 s
10...100 %
100...600* mm/s
100...400* mm/s
0...300 s
Note:
* Depending on the wing weight, the maximum values will be reduced by the
system.
6.2.6
6.2.7
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 23 of 46
SLA
6.2.8
Operating instructions
Setting examples
Changing the operating mode
Select the desired symbol by means of the arrow key (symbol starts flashing).
Confirm with the OK key (frame/bar switch over).
LOCK ?
Temporarily disabling the keylock (60 s)
Short simultaneous actuation of the C-key and the right-hand arrow key.
UNLOCK
Summer opening / winter opening
Short simultaneous actuation of the arrow keys (= access to the menu level).
Confirm the change by means of the OK key.
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 24 of 46
SLA
Operating instructions
Parameters (hold-open timeday)
Short simultaneous actuation of the arrow keys (= access to the menu level).
By means of the arrow key, select To.
Confirm with the OK key.
By means of the arrow key, change the value.
Confirm with the OK key.
To
Reset
Short simultaneous actuation of the arrow keys (= access to the menu level).
By means of the arrow key, select Reset.
Confirm with the OK key.
Reset?
Display-Reset D-BEDIX
Keep the C key depressed during 3 seconds.
D-BEDIX is restarted (however, the setting-up procedure of the door is not repeated).
6.2.9
Error display
As soon as an error occurs, the mention ERROR appears on the display, followed by
the number of the presently active error (e.g. E 703).
Provided that no additional error is pending, END is displayed (error list: see chapter
Troubleshooting).
This sequence will be repeated until the error has been eliminated.
ERROR:
0639-990-21---30j_2010.07.indd
7O3
0639-990/22j
Page 25 of 46
END
SLA
6.3
Operating instructions
KOMBI-D-BEDIX (option)
In addition to the functions of the D-BEDIX,
the KOMBI-D-BEDIX contains a key-operated switch (round or profile cylinder) with the
following function:
Lockout of the KOMBI-D-BEDIX against
unauthorized use.
Free
Locked
Round cylinder
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 26 of 46
Profile cylinder
SLA
6.4
Operating instructions
Manual unlocking
internal
Note:
Cylinder types: see application
sheet P 20.05.15.
<5s
mechanical unlocking
mechanical unlocking
>5s
mechanical unlocking
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 27 of 46
SLA
Operating instructions
service
A regular service (maintenance/checking) is absolutely indispensable in order to guarantee a safe operation and long lifetime of the installation. The service must be carried
out by a qualified person, at least once a year, according to the following checklist.
This checkup work basically refers to visual and functional checking destined to evaluate the integrality, the condition and the efficiency of the components and safety devices
(checking of the different elements as far as these are included in the installation).
Warning:
To avoid jeopardizing the safety of persons, any defective safety elements
may not be disonnected in order to continue the operation of the installation!
Attention:
In order to guarantee the availability of the installation, any elements showing signs of wear must be replaced as a preventive measure!
Note:
Every maintenance service which has been carried out shall be entered
into the control booklet!
The following service description refers to the basic components. The options are described in detail in chapter Options.
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 28 of 46
SLA
7.1
Operating instructions
1
2
Adjust
Drive mechanism
Drive mechanism
Holding power in CLOSED position
Transmission elements such as:
toothed belt, flat belt, cables, rods or chains
Carrying rollers/counter-pressure rollers, running carriages
Carrier rails
Open/Closed positions
x
x
x
x x
x x
x x x
x
x
x
x
x
x
x
x
x
x
x
Clean
Installation
General condition
Free door movement (manually)
Door guides/guideway rails
Door sealing joints
Side panels/protection wings
Coverings/hinge-type covers
Check tight fitting of the screws and nuts
Clean the installation2
Check
Grease
Warning:
Electrocution hazard! Before working on any live elements, pull out the
mains plug as well as any existing plug of the emergency battery respectively switch off the main installation switch!
x
x
x
x
x
x x
x
Control
Electrical connections
Control functions
Program switch (BEDIS, BEDiX, etc.) check all the positions
Emergency battery
Emergency opening (pull out both power plugs of the ANTEs)1
x
x
x
x
x
Control elements
All the existing control elements such as:
sensor, radar, key-operated switch, contact carpet, etc.
x x
Safety elements
Reversing/stopping mechanism
Door locking/manual unlocking mechanism
Mechanical emergency opening
Monitoring switch
Light barrier/Presence detector
Existing additional safety elements
Minimum escape way width1
x
x
x
x
x
x
x
Miscellaneous
Stickers/rating plates
x x
x x
x x x
x
x x
x
x x
x
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 29 of 46
SLA
7.2
Operating instructions
500 g
LB
10...20
1. Check the tension of the toothed belt (by means of 500 g): Measure 10...20 mm.
M6
0630-637
6,4/12 x 1,6
M6 x 8
Attention:
Checking the OPEN stop pieces: In the OPEN position, the
sliding doors must touch both
stop pieces.
HSK
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 30 of 46
SLA
Operating instructions
Troubleshooting
Warning:
Electrocution hazard! Before working on any live elements, pull out the
mains plug as well as any existing plug of the emergency battery respectively switch off the main installation switch!
If a malfunction occurs which might be detrimental to the safety of the users,
and which cannot be eliminated without delay, the operator must be informed
and if required the installation shall be taken out of operation. The installation
must be repaired as soon as possible.
Note:
Every troubleshooting procedure which is carried out must be entered into
the control booklet!
A reset activates a new setting-up procedure which is carried out only in the operating
mode AUTOMAT.
Note:
The setting-up procedure is only carried out in the mains-powered mode,
whereas no setting-up is possible in the emergency battery mode because of
the restricted battery power. The control unit STERE is automatically switched off.
8.1
8.2
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 31 of 46
SLA
8.3
Operating instructions
Malfunction
An alleged error may by all means also be due to correct causes. For this reason the list
shown hereafter has been established, which contains the probable or already encountered irregular functioning, their possible causes as well as the corrective action (error
elimination) to be taken.
Irregular functioning
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 32 of 46
SLA
Operating instructions
Irregular functioning
The radar/presence detector is triggered (reflection of metallic objects, sees the sliding wing,
vibrations of the covering), (LED OKx is illuminated).
Excessive friction (obstacle detection).
Path obstructed by an object (obstacle detection).
Loss of position due to a skipped belt. Check the belt tension. Reduce the speed parameters.
Check rubber cable of MENO.
The control unit has already been used for another installation. Carry out Reset.
Excessive friction.
Door sealing gaskets ripped out.
Sliding wings are not parallel.
Rubber cable of MENO is to much streched.
During setting-up, the door Belt connection piece has not been correctly mounted.
starts by opening.
Incorrect adjustment of the sense of rotation GEMO.
The door is readjusted
every time it is switched
on.
The radar/presence
detector is permanently
triggered.
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 33 of 46
SLA
8.4
Operating instructions
8.4.1
8.4.2
8.4.3
Description
Corrective action
10...19
Mode
NIGHT
Closure
possible
yes
Mode
NIGHT
Closure
possible
No.
Description
30
yes
31
30 V external short-circuit/failure or
second STERE defective.
yes
32
37
39
yes
yes
yes
Overvoltage errors
Mode
NIGHT
Closure
possible
No.
Description
Corrective action
33
Overvoltage on 30 VDC.
yes
34
yes
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 34 of 46
SLA
8.4.4
8.4.5
Operating instructions
Hardware errors
Corrective action
Mode
NIGHT
Closure
possible
No.
Description
41
Too many failures on encode cable. Ceck GEMO (encoder and motor connector).
yes
42
Sliding wings may be blocked. Enco- Check the sliding wings, check GEMO (encoder
and motor connector).
der unplugged.
Check the manual locking.
no
43...46
no
60...61
yes
62...63
no
64
no
Accessories errors
Mode
NIGHT
Closure
possible
No.
Description
Corrective action
105
yes
618
Manual locking.
Select NIGHT operating mode. Disengage the manual locking. Select AUTOMATIC operating mode.
Is only detected if DIP3 has been activated.
yes
900
D-BEDIX error.
yes
901
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 35 of 46
yes
SLA
8.4.6
8.4.7
8.4.8
Operating instructions
No.
Description
Corrective action
1000
1001
no
1002
no
1007
A sliding wing weight of <20 kg was Check the sliding wing and the toothed belt coumeasured.
pling.
yes
No.
Description
Corrective action
1601
yes
1602
yes
1603
yes
Description
Corrective action
2000
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 36 of 46
Mode
NIGHT
Closure
possible
yes
SLA
Operating instructions
Shut-down
No particular measures need to be taken for de-commissioning the installation.
If the sliding door installation will not be used during at least 1month, it is re-commended
to pull out the mains plug (and, if provided, the battery plug).
Attention:
For this purpose, the door must be in the operating mode NIGHT, in order to
avoid a discharge of the emergency battery (option).
If an installation with emergency battery is planned to be taken out of operation for a
period exceeding 1 year, the mains cable of insttalations containing an emergency battery
must be plugged in once a year for at least 24 hours in order to allow the batterie to be
recharged.
For taking the installation back into operation, all you have to do is to plug in the mains
cable/the battery connector and select the operating mode on the key-operated program
switch.
Attention:
If the installation is re-commissioned at low temperatures, it must be switched on 1...2 hours prior to the actual setting-up procedure (so that the
operating temperature can be reached).
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 37 of 46
SLA
10
Operating instructions
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 38 of 46
SLA
Operating instructions
11
Spare parts
11.1
Drive technique
Article No.
Designation
Abbreviation
0639-100
Gear motor
GEMO
0635-104
4527-210
ZARI
LAUWA
LAUROX
0639-131
0639-131/15
STERE
STERE
0639-115
SEIDE
0639-120
Locking of running carriage
0350-343/00 PCB
0635-218 HERI monitoring
LAVERI
0639-140
Locking of running carriage Fail Safe
0639-141 Unlocking set LAVERI Fail Safe
0639-142
Modification set LAVERI Fail Secure
0639-386
PCB programmed
LAVERI-FS
BATPA
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 39 of 46
Operating instructions
SLA
11.2
11.3
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 40 of 46
SLA
11.4
Operating instructions
4310247
4310243
4340018
*Sources of supply:
Wicona
Hydrobuilding Systems AG
CH-5506 Mgenwil
Tel. +41 62 887 41 10
Fax +41 62 887 41 30
Wicona
Hydrobuilding Systems GmbH
D-89077 Ulm/Donau
Tel. +49 731 39 84-0
Fax. +49 731 39 84-241
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 41 of 46
SLA
Operating instructions
12
optionS
12.1
Recharging
1. Disconnect the connection cable from the batteries.
2. Recharge the batteries individually during approximately 12 hours:
Charging voltage
14,7 VDC
Charging current max. 0,36 A
3. Reconnect the connection cable and mark the charging date.
Storage hints
Never store the emergency battery in discharged condition (recharge it as soon as possible).
Before storing the emergency disconnect all the consumers.
Never expose it to a heat source.
Never expose it to direct insolation.
Store the battery in vertical position, on a horizontal base.
Check the voltage at regular intervals.
Use nothing but a dry rag for cleaning the battery.
Attention:
If the storage temperatures are below freezing point, the battery must be
handled with great care, as the synthetic material of the battery housing
hardens and thus more sensitive to damaging.
Store in a cool and dry place.
Ambient temperature between -35 C and +50 C.
The storage temperature has an influence on the spontaneous discharge of the emergency battery:
Storage temperature
below 20 C
20...30 C
30...40 C
above 40 C
0639-990-21---30j_2010.07.indd
Storage intervals
every 9 months
every 6 months
every 3 months
reduction of the lifetime
0639-990/22j
Page 42 of 46
SLA
12.2
Operating instructions
Fmax. = 40 N
Spring balance
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 43 of 46
SLA
Operating instructions
Setting the emergency opening rubber cable
Attention:
Avoid an excessive tightening of the rubber cable which would cause the
sliding wings to bump into each other when opened without mains power!
1. Manually close the sliding wing and block it.
2. Stretch the rubber cable until the spacing between the felt tip pen markings has
increased to ~ 600 mm. Shift the loose knot until it is again located right next to the
rubber cable fixing.
3. Remove the blocking of the sliding wing, then let the rubber cable pull it to the Open
position. If require tighten the rubber cable.
Attention:
The maximum distance between the felt tip pen markings must not exceed
1000 mm (which corresponds to a tension of 60 N).
4. Tighten the knot and cut off the rubber cable (max.distance between the cable end
and the knot = 20 mm).
Rubber cable untightened
~100
500
500
~100
600...1000
600...1000
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 44 of 46
SLA
12.3
Operating instructions
LAVERI-FS
Locking latch
0639-990-21---30j_2010.07.indd
Locking hook
0639-990/22j
Page 45 of 46
SLA
13
Operating instructions
Appendix
The following documents are added as an appendix to this manual:
Wiring diagram.................................................................................................. E4-0141-029
0639-990-21---30j_2010.07.indd
0639-990/22j
Page 46 of 46