Flowchart-Sampling QAQC PDF
Flowchart-Sampling QAQC PDF
Surveyed
Scraped
by Excavator
Intervals
Marked Out
Intervals
Mapped
Blown Down
with Compressed
Air
Yes
Hard or
Weakly Jointed
Rock
No
Paint Line
Sprayed
Fragments
with paint
collected
Broken with
Rock Drill
Sample Placed
in Tray
Sample ID
Generated
Sample Tag
Inserted
(RL-East-NorthFrom)
Sample Trays
collected
Transported
to Sample Prep
Date:14-Sept-2004
Waihi Gold
Revision: 1.1
Channel Sample
(3.6kg Nominal)
Dried 7 hours
O
80 C
2 Jacques Jaw
Crushers in Series
95% Passing
7mm
Vibrating Feeder
Reject Discarded
75%
(2.7kg)
Rotary Sample
Divider
25% (0.9kg)
LM2 Mill
3.25min
80% Passing
75m m
Residue
Discarded
700g
Bowl Washed
after every sample
200g By Scoop
HSC assay on
75g sub sample
(see Assay
Sheet)
Date:14-Sept-2004
Revision: 1.1
Waihi Gold
200g Prepared
Sample
75g Sub
Sample
(by scoop)
100ml
1% Cyanide
Solution
Added
Residue Stored
1 Week
30ml Slurry
O
Heated 80 C
30 minutes
Centrifuge
3000 rpm
3 minutes
Solution
Analysed for Gold
by AAS
Waihi Gold
Drawn: PKJ
Date:14-Sept-2004
Revision: 1.1
Sample Batch
(max 240
Samples)
Despatch Number
Generated
<ddmmyy><batch_count>
Despatch
Number
Assigned
Despatch
& Interval
Files Generated
Sample Despatch
to Lab
via E-Mail
Sample
Intervals
Lab Job
Number Assigned
AcQuire Import
Object
(Insert)
Assay
Au by HSC
Ag by AR
Assay
Results
Via E-Mail
AcQuire Import
Object
(Merge)
AcQuire
Database
AcQuire Direct
(ODBC)
MineSight
Composite
Database
Date:14-Sept-2004
Waihi Gold
Revision: 1.1
Assay Standards
Assay Batch
1 Std/30 Samples
Standards
within 2SD
Yes
Review
performance
on monthly basis
No
Re-Submit
Samples in same
run as Standard
Include Detail of
Re-Submission/
Errors
Report Monthly
Assign new
Sample ID
Insert Blind
Standard(s)
HSC assay
Investigate
Cause
with Lab
Yes
Review
performance
on monthly basis
Apparent
Bias?
No
Include Detail of
Cause
Report Monthly
Assay Data
Quality Control
Waihi Gold
Drawn: PKJ
Date:14-Sept-2004
Revision: 1.1
30 Samples
every 3 Months
Insert Blind
Standard(s)
Assign new
Sample ID
Investigate
Cause
with Lab
Review
performance
on 3 monthly basis
Apparent
Bias?
Yes
No
Include Detail of
Cause
Report 3 Monthly
One Sample
per Day
Repeat
HSC Assay
Review
performance
on monthly basis
Report
monthly
30g Fire
Assay
Assay Data
Quality Control
Waihi Gold
Drawn: PKJ
Date:14-Sept-2004
Revision: 1.1
Sample Weights
First Sample
Processed Daily
Weigh Sample
Review
on
monthly basis
Average
within
0.6kg
No
Adjust Sample
Size
Yes
Report
monthly
Include Detail of
Adjustment
Jaw Product
Composite First
5 Samples
Processed Daily
Weigh Sample
7mm Sieve
(~3 Mesh)
Weigh Retained
Material
Adjust/Replace
Jaw Plates
Yes
>5%
+4.75mm?
No
Include Detail of
Adjustment
Report
monthly
Product Sizing
Quality Control
Waihi Gold
Drawn: PKJ
Date:14-Sept-2004
Revision: 1.1
Weekly
Composite of 20
Consecutive
Reject Pulps
Estimate Mapped
Quartz %
Weigh Sample
Weigh Retained
Material
Investigate
Cause
eg worn bowls/pucks
high qtz% etc
Yes
>20%
+75m m?
No
Report
monthly
Product Sizing
Quality Control
Waihi Gold
Drawn: PKJ
Date:14-Sept-2004
Revision: 1.1