Ee4701-Advanced Ee Lab: Power Systems Lab Experiment No: 2 EE11B049-Vishnu Bhargav EE11B008 - Mrugender Lal
Ee4701-Advanced Ee Lab: Power Systems Lab Experiment No: 2 EE11B049-Vishnu Bhargav EE11B008 - Mrugender Lal
EE11B049- Vishnu
EE11B008-
OBJECTIVE:
To study the various power components and parameters for
balanced, unbalanced, linear and nonlinear loads connected to 3 phase
supply , using MATLAB/SIMULINK software. In this simulation ,we shall
study the effect of unbalance and non-linear loads by studying the
various power components and parameters.
Source Voltages : vsa, vsb , vsc
Source Currents : isa ,isb ,isc
Load Currents : ila,ilb,ilc
Case 1 :
Case 2 :
Voltages are balanced but load currents are unbalanced.
Source voltages - vsa = vsb = vsc = 230 V RMS
Load Impedences : Za = 150+j16 ; Zb =50+j47 ; Zc = 75+j16
Average Real Power :
P = 1585 W ; Pa =674.7 W ; Pb = 561.4 W ; Pc =348.6 W
Average Reactive Power:
q = 709.2 VAR
Apparent Power :
S = 1811.2 VA ; Sa= 350.7 VA ; Sb = 770.7 VA ; Sc = 689.8 VA
Power factor :
Pf = 0.8510 ; Pfa = 0.9781 ; Pfb = 0.7207 ; Pfc = 0.9941
Total Harmonic Distortion:
%THDIa = 0 ; %THDIb = -6.032 e-6 ; %THDIc = 7.027 e-6
%THDVa = 7.867 e-6 ; %THDVb = 0 ; %THDVc = 1.190 e-5
Instantaneous Real Power:
Case 3 :
Voltages are unbalanced and load currents are unbalanced.
Source voltages - vsa = 230 V ; vsb = 0.8*230 V ; vsc =1.1* 230 V RMS
Load Impedences : Za = 150+j16 ; Zb =50+j47 ; Zc = 75+j16
Average Real Power :
P = 1524 W ; Pa =916.4 W ; Pb = 359.3 W ; Pc =349.6 W
Average Reactive Power:
q = 595.8 VAR
Apparent Power :
S = 1678.7 VA ; Sa= 350.7 VA ; Sb = 770.7 VA ; Sc = 834.7 VA
Power factor :
Pf = 0.9081 ; Pfa = 0.9781 ; Pfb = 0.7204 ; Pfc = 0.994
Total Harmonic Distortion:
%THDIa = 0 ; %THDIb = 6.853 e-6 ; %THDIc = 5.589 e-6
%THDVa = 7.867 e-6 ; %THDVb =1.227 e-6 ; %THDVc = -7.072 e-6
Instantaneous Real Power:
Case 4 :
Voltages are balanced but load currents are unbalanced and distorted.
Source voltages - vsa = vsb = vsc = 230 V RMS
Load Impedences : Za = 150+j16 ; Zb =50+j47 ; Zc = 75+j16
Rectifier Load : R =200 and L=80mH
Average Real Power :
P = 3026 W ; Pa =1153 W ; Pb = 1039 W ; Pc =834 W
Average Reactive Power:
q = 715.2 VAR
Apparent Power :
S = 3210.4 VA ; Sa= 848.4 VA ; Sb = 1183 VA ; Sc = 1179 VA
Power factor :
Pf = 0.9424 ; Pfa = 0.9781 ; Pfb = 0.770 ; Pfc = 0.9831
Total Harmonic Distortion:
%THDIa = 17.9 ; %THDIb = 12.73 ; %THDIc = 12.78
%THDVa = 7.324 e-6 ; %THDVb = 4.229 e-6 ; %THDVc = 1.295 e-5
Instantaneous Real Power:
Case 5 :
Voltages are unbalanced but load currents are unbalanced.
Source voltages - vsa = vsb = vsc = 230 V RMS
Load Impedences : Za = 150+j16 ; Zb =50+j47 ; Zc = 75+j16
Rectifier Load : R =200 and L=80mH and Feeder Impedences Zsa = Zsb
= Zsc = 2+j3.14
Average Real Power :
QUESTIONNAIRE:
1.Why the voltages and currents are become
unbalanced and what are their effects on power system?
A. Voltages and currents are unbalanced because of
unbalanced or non-linear loads . This causes poor power factor,
large neutral current ,more looses in electrical machines and
transformers , de-rating of transformers and machines and
large reactive power requirement.
2.What are the sources of harmonics and how they
affect the system?
A. Harmonics voltages and currents in an electric power
system are a result of non-linear electric loads. One of the
major effects of power system harmonics is to increase the
current in the system.
3.How the neutral current (InN) depends upon the
unbalanced load currents?
A. The neutral current can be determined by adding the three
phase currents together. In an unbalanced system sum of the
unbalanced currents is not zero. Hence it results in non zero
neutral current.
1
T
t +T
p (t) dt
t
Apparent Power
S=Sa+Sb+Sc ; Sa = Va*Ia ; Sb= Vb*Ib ; Sc = Vc*Ic
Power factor =
P
S