Etabs Tutorial
Etabs Tutorial
Start of every structure modeling, already done by clicking on New Model on Standard tap
in all versions of Etabs. lets click on new model.
here 3 options was considered for model initializing in Etabs2013 with minor differences
relative to previous versions:
First one is using of saved user default settings option. By choosing this one you can use
last saved options, preferences , units on your etabs software. when you work on one model
in etabs 2013 and you set units ,options , preferences as you want, you can save your default
options on software.( how to save options will be explained in future sections) . Next time
when etabs will opened or new model be started, you can load your arbitrary options by
clicking on saved user default settings option on Model initializing window.
Second option is use setting from a model file. this item also are exist in previous versions
entitled choose .edb . you can load settings and units by this way from existing model files.
The last one is used to define new options , references and units at starting of modeling. By
choosing use built-in setting you can define your kindly options and setting at start of
modeling.
Regarding above description all three way of model initializing will be useful in practice.
Also by default, quick help icon as
related options.
After selection of one of three alternatives in model initializing window, model template
window will open which has no differences relative to previous versions of Etabs as shown in
below:
2- System Units
Any modeling want to be started, first and better be first, unit systems to be defined.
In Etabs 2013 system units has been a little changed relative to previous versions.
Holding mouse pointer in unit icon at right-down of Etabs windows, displays current unit
details as shown in following figure:
Another unit control option is Consistent units which approximately acts same as unit
option of previous versions of Etabs. Following window will open by clicking on Consistent
unit.
In consistent unit window, units for length , force and temperature can be defined arbitrarily.
May be someone want to use SI unit for length, MKS system for force and U.S system for
temperature, May be. So in mentioned window he can select units as he want.
The last item in unit sub-window is show units form which is most useful option in
practical cases. Display units window as shown in below will open when show units
form be clicked.
In practical cases, different units are preferred to use for same class of units. For example as
marked in above figure for structure main dimensions, meter (m) can be considered. for area
of beam or column section cm^2 and for rebar area mm^2 may be used. On the other
hand someone wants to read force results by kgf but moment in Ton.m. this window
allows to change all unit.
Also changed units can be saved for future modeling by this window as shown in below.
3- Grid definition
At start of any modeling, if grid system is defined well, modeling procedure will be quick and
easy. In Etabs 2013 grid definition and modification are more different relative to past
versions.
Template grid system can be defined from new model template window similar to previous
versions as described in section 1 ( initializing modeling) and show in following figure:
After loading grid template, etabs modeling windows will open, one shows plan view other
shows 3D view of modeling similar to past versions. By default grid spacing is seen in plan
view in Etabs 2013.
Two ways are existed to modify grids. One through right-click in modeling window, other
through Edit menu. Both way are illustrated in following figures.
Following window named as Edit Story and Grid system data will open by this way.
Few Edit options will be seen in above window numbered as 1 to 9 to simplify description.
Story data will be edited through item No.1 (Modify/show story data). In opened window as
shown in following figure, stories can be added, deleted or edited in height as show in below.
Second item is Quick add story through which more stories can be added quickly by
properties of last existing story.
If name of stories has been changed by user, they can be return to their default name by item
no.3 (set story names to default) in Edit story window.
New grid system can be defined in addition to existing grids through item No.4.
Following window appears by clicking on Add new grid system.
In this window, grids can be defined in either Cartesian system or Cylindrical. Also grids
origin and orientation can be chosen arbitrarily.
Multiple grid definition also is existed in previous versions. But major and very useful
difference here is defining origin and orientation of grids which helps to fast modeling of
complicated buildings.
For example, consider following building:
One of easiest ways to modeling of such buildings is defining of two grid systems.
Here two grid systems one in Cartesian second in Cylindrical have been defined as shown in
below. The origin of cylindrical system has been moved to axe 1-C to create whole scheme of
building. Then structural elements have been drawn using current multiple grid system.
Item No.5 shown in Edit Story and Grid system data window (Modify/show grid system) is
used to modify all defined grid systems.
Clicking on it, following window appears:
In this window, system origin, X grid and Y grid data including grid spacing and bubbles
location can be modified.
New facility which has been provided in Etabs 2013 is general grids pan. In this pan user can
defined auxiliary grids to existing grid system.
sample is shown in below:
Other item in Edit Story and Grid system data window marked as No,6 is used to delete
grid system.
Item No,7 copies grid properties form one of existing grid systems to define another new grid
system.
Item No,8 and 9 in Edit Story and Grid system data window is used to bring grids scheme
from AutoCAD DXF files.
4-Define menu
All definitions for structure modeling including material, frame and wall sections, springs
etc., will be done through define menu. Here each item of define menu is described separately
as sub-sections and any discrepancies with previous version(s) will be noted.
Define menu in Etabs 2013 will be accessed from menu-bar as indicated in following figure.
Another way is adding Define-bar to toolbars area as shown in below to fast access to define
items.
Through right-click on tool bars area, small selection pan appears.
4-1-Material properties
Here in Etabs 2013 , there are some differences relative to previous version(s).
Form Define menu or from Define toolbar, material properties can be accessed as shown
in following figures.
In define materials window, three item will be seen. New materials will be defined through
first item as shown below.
By clicking on Add New Material new window will open which was not be ever seen.
In this window as illustrated in below, material can be selected based on country (Region)
and most known material standards and grades. China, Europe, India, Italy, Spain and United
states are countries whose standards have been considered in Etabs 2013 by default.
Other users, which their Standards dose not matched with predefined categories, they can
select and modify standard of considered countries or use user material as shown in below.
In this window, Material weight ,mechanical property and design property which marked
with blue color are same as previous version.
But items marked with red color at above figure are new.
In Nonlinear material data, nonlinear properties of considered material can be defined. This is
different from nonlinear hinges of previous versions. In most of nonlinear Structure studies,
two way can be followed for plastic definition of materials. Extensive plasticity or
Concentrated plasticity. Some of seismic analysis software like Opensees have both plasticity
method. But in previous versions of Etabs and Sap2000 only concentrated plasticity known as
nonlinear hinges could be considered. But in Etabs 2013 it seems both plastic definition can
be proceeded.
In user defined mode as shown below, all stress strain points will be changed manually.
Two other items marked in Define material window as below, can be used for modification
of existed materials.
Also all items in section properties list, are accessible in define tool bar as shown in
following figure.
Here three selection pan will be seen. First is property file in which saved section properties
will be loaded.
Second pan is related to material for section property.
And last one is used for quick selection as filter from imported properties.
Following figures show step by step of HEA200 importing.
New thing which has been added to Etabs 2013 , is modification of imported sections.
In previous versions there is no way to modify imported section anywhere is needed.
But here, first select imported property then click on Modify/Show property as shown
below.
Any defined or imported section can be converted or copied to SD section (Section Designer)
in Etabs 2013.
Finally it should be note that, all defined or edited section properties except those ones
created by section designer, can be exported to XML file to use in other modeling.
4-2-2-Slab/Deck/Wall Definition
In Etabs 2013 , definition of slabs ,decks and walls have been developed so as all kind of
floor and wall systems be covered.
It can be said only slab definition has been changed. Deck and wall definition will be done
same as previous versions.
Here in Etab 2013 , four property type including flat slab, drop panel, ribbed slab and waffle
slab can be considered as slab property. In this regard select slab section in define tool bar as
shown in following figure. Parallel definition method can be found in define menu as said
before.
In slab property data window, slab material, element type and property type can be defined.
Following figures give some information in this regard.
New feature which has been added to Slab property data window, is property data list.
In this selection list, desired kind of slab can be selected.
In Deck property data window three kind of deck including filled, unfilled and solid slab
can be selected as shown in below.
The sketch of each type will appear through holding mouse cursor on icon named with i as
shown in following figure.
This sketch gives information about needed parameters to definition of deck.
4-2-3-Link/Support
At some advanced building modeling , for example damping modeling or base isolation
studies,
There are requirements to modeling of some certain link/support properties and then assign to
desired joints.
Here in Etabs 2013 there are more alternatives to define of link elements.
The types of nonlinear behavior that can be modeled through link/support element include:
Viscoelastic damping
Gap (compression only) and hook (tension only)
Multi-linear uniaxial elasticity
Uniaxial plasticity (Wen model)
Multi-linear uniaxial plasticity with several types of hysteretic behavior: kinematic, Takeda,
and pivot
Biaxial- plasticity base isolator
Friction - pendulum base isolator, with or without uplift prevention.
In this regard , From define toolbar as indicated in following figure, link property definition
will be accessible.
In appeared window, link type can be selected. As seen in following figure, there are more
link types to define relative to previous versions.
by clicking on modify/show key on Link property data window, another window as show in
below will open in which nonlinear or stiffness property including hysteresis behavior can be
determined.
Panel zone can be applied and assigned on beam-column connection joints Along with rigid
offset zone, which affects on results of moments and deflection of frames.
4-3-Spring properties
One of new features which was added in define menu of Etabs 2013, is springs definitions.
Joint, line and area springs first will be defined in define menu as shown in following figure,
then they can be assigned on various elements of model.
Also here in Etabs 2013, there is a way to define compression or tension only springs unlike
previous version. As marked in following figure, rotational springs for line elements also can
be specified .
4-5-pier/spandrel define
In order to design of concrete shear walls, usually pier and/or spandrel label shall be defined
then assigned to the walls. Unlike previous versions pier/spandrel label can be defined in
define menu as marked in following window.