Plus
DMS
Automated Hematology Analyzer
MEK-7222J/K
22 parameters with WBC 5 part differential
User-friendly Operation
with a Compact Body
Shown with optional built-in printer
The best choice for your lab
WBC 5 part differential with advanced laser technology
provides reliable data at low cost
User friendly operation
Compact
High accuracy and reliability
Low reagent consumption
Optional network and
Data management expandability
22 parameters
2 11
WBC
NE%
LY%
MO%
EO%
BA%
NE
LY
MO
EO
BA
RBC
HGB
HCT
MCV
MCH
MCHC
RDW
PLT
PCT
MPV
PDW
Celltac innovation in hematology analyzers since 1972
S imple operation and compact design
Only 3 steps to get a result
Standalone design
Step 1. Press the power key
Celltac E provides complete WBC 5 part differential
and CBC measurement without a PC. This
contributes to easy operation for staff who are not
frequent operators such as off-peak shift in the ER
or ICU. Celltac Es compact size (only 380 mm width
and 485 mm depth, not including reagent bottles)
also saves desktop space.
Priming is automatic and it is ready for use within
one minute.
Step 2. Bring the sample to the nozzle
Bring a whole blood sample to the sampling nozzle.
Step 3. Press the count switch
Aspiration and counting start.
All numeric data, histograms and scattergrams are
shown on a backlit LCD display. The display has
touch screen operation for easy editing of measured
data. Data is automatically printed on an optional
built-in printer or external printer.
Variety of measuring modes
CBC or CBC + WBC 5 part diff
You can select only the necessary measurement
CBC only, or CBC + WBC 5 part differential. This
helps eliminate unnecessary reagent consumption.
Open and closed sample measurement
Celltac E has a unique design cap pierce unit (option).
It can be used for closed as well as open sample
measurement.
(Screen shown: Celltac E)
Open mode
Closed mode
3 10
&
High accuracy and reliability
Technologies for reliable data
Patented laser technology
An innovative 3 angle laser scatter detector provides
better detection of scattered light from the WBC
cell. From a small forward angle it obtains WBC
size information, from a large forward angle it
obtains information of cell structure and complexity
of nucleo-chromatin particles, and from a side
angle it obtains internal granularity and globularity
information. This 3D graphic information is calculated
by a special Nihon Kohden software algorithm and
superior classification of WBC 5 part diff population
is displayed on the screen.
No chemical processing of WBC
NE
S
i
z
e
S
i
z
e
BA
MO
EO
Granularity
Granularity
Size
MO
NE
EO
S
i
z
e
BA
The patented leukocyte classification reagent
selectively hemolyzes the red blood cells while
leaving the white blood cells intact. The nucleus,
granules and cellularity remain intact so Celltac E
and Celltac F can get information from natural
shaped WBC nuclei and granules and perform more
accurate WBC 5 diff measurement.
LY
Complexity
Granularity
Complexity
Optimal flow channels
A consistent aspiration volume of diluted sample is maintained by a manometer for stable and accurate CBC
measurement. The short fluid paths of Celltac E and Celltac F allow utilization of the entire sample without
waste. A Nihon Kohden patented double mixing chamber, twin sample needle and sampling nozzle cleaning
holder minimize contamination and allow high accuracy and high reproducibility measurement.
4 9
Celltac innovation in hematology analyzers since 1972
Plus
Useful flag messages
New flags and improved measurement
Flag messages
[LMI]
Ly-Mo Interface is displayed in the flag display area.
The following messages can be displayed or
printed when the measurement result is out of
range.
[NEI]
Ne-Eo Interference is displayed in the flag display
area and * marks after a #NE, %NE, #EO, or %EO
value indicate invalid data.
[PRI]
PLT-RBC Interference is displayed in the flag display
area and * marks after a RBC or PLT value indicate
invalid data.
[SNC]
Small Nucleated Cell is displayed in the flag display
area, and * marks after a WBC value indicate invalid
data.
ALL: Acute Lymphoblastic Leukemia (L2)
WBC
LC%
LC#
Flags
S
i
z
e
S
i
z
e
Complexity
16.5 X 103/mL
90.7%
14966/mL
SNC
WBC
LC%
LC#
Flags
S
i
z
e
Granularity
* Erythrocytosis
* Anemia
* Anisocytosis
* Microcytosis
* Macrocytosis
* Hypochromia
* Abnormal MCHC
* Thrombocytosis
* Thrombocytopenia
* PLT Clumps
* PLT RBC Interference
* If C appears on the
right width of the
WBC or PLT data,
the PLT may be
coagulated.
CLL: Chronic Lymphocytic Leukemia
5.1 X 103/mL
64.4%
3284/mL
LMI
SNC
S
i
z
e
Granularity
* Leukocytosis
* Leukopenia
* Neutrophilia
* Neutropenia
* Lymphocytosis
* Lymphopenic
* Monocytosis
* Eosinophilia
* Basophilia
* Blasts
* Immature Gr
* Left Shift
* Atypical Lymphocytes
* Small Nucleated Cell
* Ly-Mo Interference
* Ne-Mo Interference
S
i
z
e
Complexity
S
i
z
e
Granularity
Granularity
5 8
&
Data Management Expandability
Plus
Data Management Software (DMS Pro, QP-822V) (option)
Additional research parameters
Customizable print format
The DMS Pro software gives research parameters of
ImG (Immature Granulocyte), ImG%, Band, Band%,
SEG and SEG%.
You can enter input manual count data from the PC
keyboard and add the column to the printed results.
You can also add images from the PC.
Data view function
You can compare and choose data with the
thumbnail scattergram list.
QC management
Editing print layout
You can easily edit the print layout with the mouse.
6 7
Celltac innovation in hematology analyzers since 1972
Network expandability
Display and printing acquired data
on a PC
Transferred data can be displayed on a
spreadsheet in the PC. All displayed data
included color scattergrams and histograms
can be printed on a color printer.
Celltac E and Celltac F can be used alone or with a PC.
If you connect it to a PC with optional Data Management
Software, data can be stored on a server. Celltac F can also
be connected to an LIS and HIS network system in you
laboratory.
LIS or HIS
Bar code label printing
Bar code labels for the work list can be
printed on the optional thermal printer.
Laser printer
Celltac F
Connection to LIS and HIS network
The PC can be used as a gateway to a
Laboratory Information System or Hospital
Information System.
Thermal printer
DMS
(PC + QP-822V)
Host (LIS)
Large data storage
Numerical data, scattergrams and
histograms for each measurement can be
saved on a PC and read anytime. Data
can be saved on CD-R or other media for
virtually unlimited storage.
or
Celltac E
Celltac F
LAN
Impact printer
Bar code reader
Bar code example
Input the work list file
160 sample throughput and low
cost backup
A DPC-Celltac (Dual Process Controlled
Celltac) system can control dual Celltac F
analyzers. This increases throughput to 160
samples per hour and can be used as a low
cost backup system for your lab.
Create your original result file
Host (LIS)
DMS
(PC + QP-822V)
Bar code
Measured data
Celltac F
Work list
7 6
&
Effective total cost management
Useful functions for reliability
WBC high dilution measurement
Work list function
When WBC is high, noisy or has poor
hemolyzation, you can remeasure it by
automatically changing the dilution ratio.
You can preset patient information such as ID, physician
name, measuring parameters, and comments for samples.
WBC expanded measuring range
WBC high and higher dilution modes allow
expansion of the measuring range, Celltac
E and Celltac F can measure WBC to 599
103 L.
If you connect a PC with Data Management Software (QP822V), you can enter the patient information on the PC and
send it to a Celltac E and Celltac F. After measurement the
data can be sent back to the PC.
Celltac E: Up to 50 work list data can be entered.
Celltac F: Up to 500 work list data can be entered.
You can choose work list mode with or without bar code.
Reagent management system
When a reagent reaches the warning
volume, a warning window is displayed.
Useful QC management programs
Celltac E and Celltac F provide 4 QC programs: X bar-R,
Levey & Jennings, X bar Batch and X bar Day CV for
quality control. These programs automatically calculate the
plotting data from the sample data.
8 5
Celltac innovation in hematology analyzers since 1972
Time and cost saving
Low reagent consumption
Twin needle system
A Nihon Kohden original syringe pump precisely
aspirates the low sample volume of 28 L for CBC
or 55 L for CBC + WBC 5 part diff. The sample
remains in the sampling needle so it does not need
to be sent to the syringe pump. This allows a short
fluid path for the blood sample. Also, unlike shared
valve method instruments, the syringe does not need
to be rinsed after every dispensing. These features
contribute to the small blood sample and low reagent
consumption of
Diluent
Nihon Kohden
Celltac series
hematology
analyzers.
Celltac E and Celltac F have twin sampling
needles for two baths for different dilutions of
WBC and HGB, and RBC and PLT. This prevents
counting errors from cross contamination of
dilutions.
Syringe pump
Double mixing chamber
Unique and compact blood mixing
system
Nihon Kohdens patented blood mixing system
contributes to the compact size of Celltac F. The
sample is effectively mixed in a small space by
rotating the tube instead of tipping it end over end.
Automatic electric clog removal
To preventing clogging, Celltac E and Celltac F
remove blood protein and dust particles from
the aperture by a high voltage clog shattering
electrical pulse after each measurement. If
a clog occurs,
the Celltac E
and Celltac F
automatically
remove the clog
and recount the
sample.
Fully automatic operation
When the power is turned on, the fluid path is
automatically primed and Celltac E and Celltac
F are ready to use in minutes. When the power
is turned off, the fluid path is automatically
cleaned.
Computer controlled direction and rotation speed
provides more effective blood mixing. The unique
blood mixing method creates horizontal and vertical
whirlpools of blood by alternating normal rotation and
reverse rotation. Also, the rotation speed is quickly
changed so that blood samples are evenly mixed
with no cell damage.
9 4
The best choice for your lab
Simple and intuitive interface
High speed processing
One touch operation for getting a result
80 samples/hour throughput
Large and colored switches for routine operation
allow easy operation even in emergencies. This is
useful when hematology specialists are not available,
such as the ER at night.
In just 45 seconds, Celltac F can measure CBC
or CBC + WBC 5 part diff for one sample. Its high
speed measurement of 80 samples per hour with
auto-sampler supports easy and efficient hematology
testing in your lab. On the work list 8 or 22 parameter
measurement can be set for individual samples in
the rack.
Clear display with touch screen
Celltac F shows clear classification of WBC 5 part diff
on a high resolution color TFT LCD. Measurement
condition settings, scattergrams display, data editing
and other operation is done by intuitive touch screen
operation.
STAT measurement
Celltac F can interrupt routine sample processing
to immediately measure emergency samples. You
can load emergency samples in the STAT position
on the sample rack and push the Emergency key
or you can measure and emergency sample with
the manual mode-nozzle while routine samples are
being measured in auto mode.
Automatic recount
Celltac F automatically recounts the measured sample when any of the following occurs:
Any value outside the user defined range
Alarm message
WBC outside the measurable range
Dilution level for recounting can be set to HIGH or HIGHER.
10 3
Celltac innovation in hematology analyzers since 1972
The Celltac F hematology analyzer with auto-sampler
features high speed processing80 samples per hour
throughputto support your effective lab operation
High speed processing with auto sampler
Automatic recount
High accuracy and reliability
Effective total cost management
Optional network and
Data management expandability
22 parameters
WBC
NE%
LY%
MO%
EO%
BA%
NE
LY
MO
EO
BA
RBC
HGB
HCT
MCV
MCH
MCHC
RDW
PLT
PCT
MPV
PDW
11 2
Plus
DMS
Automated Hematology Analyzer
MEK-8222J/K
22 parameters with WBC 5 part differential
Reliable, Cost-saving,
and User-friendly
6388
CAT.No.55-083A
10 .05. SZ. B
Printed in Japan on FSC certified paper