Digital Panel Meters BD
Digital Panel Meters BD
Performance
Measurement
and Instrumentation
Network
Quality
p. 130
Selection guide
p. 132
p. 134
p. 136
p. 144
DIGI ranges
3
Measurement and
Instrumentation
134 129
2010
130
DIGI2
Energy
Performance
Network
Quality
3
Measurement and
Instrumentation
C.A 2150
131
2010
Selection guide
DIGI1
DIGI2
24x48
48x96
32000
32000
-1999/+9999
-1999/+9999
AC ammeter
DIGI1 E
DIGI2 AAC
AC voltmeter
DIGI1 E
DIGI2 VAC
Frequencymeter
DIGI1 F
DC ammeter
DIGI1 E
DIGI2 ADC
DC voltmeter
DIGI1 E
DIGI2 VDC
Process signals
DIGI P/LP
DIGI2 PRC
DIGI1 T
DIGI2 TTC
Measurement functions
Thermocouple thermometer
DIGI2 TPT
Pt 100 thermometer
Ohmmeter
Tachometer
DIGI1 F
DIGI2 TAC
Meter
Timer
Load cell
Potentiometer
Special functions
MIN/MAX
DIGI1 ALP
Analogue output
RS232 output
Output(s)
RS485 output
Threshold output(s)
DIGI1 ALP
Option
BCD output
User-programmable
Strengths
Economical programmable range for industrial use.
132
1
Energy
Performance
CA 2200
48x96
48x96
32000
65000
-19999/+19999
-32000/+32000
2
Network
Quality
CA 2150
C.A 2150-E
C.A 2150-E
C.A 2150-D
C.A 2200-D
C.A 2150-E
C.A 2150-E
C.A 2200-P
C.A 2150-M
C.A 2200-T
C.A 2150-M
C.A 2200-T
C.A 2150-D
C.A 2200-D
C.A 2150-D
C.A 2200-D
C.A 2150-D
C.A 2200-D
C.A 2150-M
C.A 2200-C
C.A 2150-M
C.A 2200-P
Option
Option
Option
Option
Option
Option
Option
Option
3
Measurement and
Instrumentation
C.A 2150-M
Option
133
2010
Several criteria influence the choice of a digital panel meter, the first
being the scale or the measurement range, defined by the variation range
of the signal to be measured.
The resolution
The number of display counts defines the
resolution of the panel meter. The resolution is
the necessary variation of the measurement
signal required to vary the reading by one
point. For a given rating, the greater the display
capacity, the better the resolution.
For example, for an 11-bit (2,000-counts) panel
meter with a 20 V range, the resolution is 10 mV.
However, for industrial applications, it is not always
wise to choose a digital panel meter of too high
resolution. The measurement signal may be subject
to noise interference, resulting in the permanent
instability of lightweight display units.
Accuracy
Accuracy, which is not to be confused with resolution, defines the maximum variation between the
instrument reading and the true value of the signal
measured.
134
It is expressed as follows:
E = x% of the reading y counts.
The first term depends on the conversion method
and the precision of the components, while the
second depends on the various drift, dispersion,
fluctuation and noise factors that can affect the
instrument. The error is therefore constant over
the entire measurement range. This is one of the
main advantages of the digital panel meter over the
galvanometer, where the most accurate readings
are obtained at the end of the scale.
Format
The format and weight of the instrument must
also be taken into account, as they affect the
sizing of electrical cabinets. The format 48x96
(DIN standard 43700) is the industrial standard.
Alongside this, panel meters of reduced dimensions, such as the 25x75, have proven especially
useful for smaller-sized machines and embedded
equipment.
Energy
Performance
Display only
or multifunction products?
Panel meters are increasingly universal, and must
be able to display both strong signals, such as the
voltage of a network, and weak signals such as
process signals.
FOCUS
2
Network
Quality
3
Measurement and
Instrumentation
Display
Environment
Maintenance
>
>
Digital panel meters, in general, are intended for indoor use, Unlike the analogue panel meter, the digital panel meter accepts
135
2010
DIGI1 range
24 x 48 mm programmable panel meters for industrial use
Plug-in connectors
for quick and
easy connection
PRODUCT
ADVANTAGES
SIMPLE
PROGRAMMING
using 3 keys
Instant MOUNTING
WITHOUT TOOLS
COMPACT
DIMENSIONS
16-POINT
LINEARIZATION
for DIGI1-ALP
Display with
4 levels of
brightness
Remote configuration
of the DIGI1-ALP via
the RS485 serial link
> Programming
Quick and easy:
136
DIGI1-LP
DIGI1-P
DIGI1-E
I nput:
4-20 mA
Display range:
-1,999...+9,999
I nput:
-10 +10 Vdc
-20 +20 Vdc
-200 +200 Vdc (1M)
-100 +100 mVdc (100M)
-20 +20 mAdc (12,1)
Display range:
-1,999 9,999
I nput:
600 Vac
100 Vac
-199,9 +600 Vdc
-100 +100 Vdc (3 M)
5 Aac
1 Aac
-1,999 +5 Adc
-1 + 1 Adc (14 m)
Display range:
-1,999 9,999 (dc)
-0 9,999 (ac)
U/I voltage
and current
Power supply
Self-powered (active loop)
Reference
P01 330 000
Power supply
85 - 265 Vac & 100 - 300 Vdc
22 - 53 Vac & 10,5 - 70 Vdc
Reference
P01 330 031
P01 330 032
Power supply
85 - 265 Vac & 100 - 300 Vdc
22 - 53 Vac & 10,5 - 70 Vdc
DIGI1-F
DIGI1-ALP
F
requency meter:
0.01 Hz 7 KHz (voltage 10 to 600 Vac)
Tachometer:
Magntic
Vin > 30 mV rms (60Hz)
Vin > 300 mV rms (6kHz)
NAMUR
Rc = 1.5 k ; Ion < 1 mA ; Ioff > 3 mA
NPN/PNP
Rc = 3.9 k (NPN) ; 1.5 k (PNP)
0 < 2.4 V / 1 > 2.6 V
Encoder/TTL/24V
0 < 2.4 V / 1 > 2.6 V
SWITCH
Vc = 5V (internal)
Rc = 3.9 k (internal)
Fc = 20 Hz
Display range:
0 9,999
I nput:
-10 +10 Vdc
-60 +60 Vdc (1 M)
-100 +100 mVdc (100 M)
-20 +20 mAdc (12.1 m)
Display range:
-1,999 9,999
15-segment signal
linearization
Display with 4 levels
of brightness
Power supply
85 - 265 Vac & 100 - 300 Vdc
22 - 53 Vac & 10.5 - 70 Vdc
Power supply
85 - 265 Vac & 100 - 300 Vdc
22 - 53 Vac & 10.5 - 70 Vdc
Frequency,
rpm, pulse
Reference
P01 330 041
P01 330 042
Current transformers
& shunts
> page 90
Tachometric
sensor
> Contact us
Energy
Performance
Reference
P01 330 011
P01 330 012
DIGI1-T
Temperature (Pt100
and thermocouple)
Network
Quality
Process signal
with alarms
Reference
P01 330 021
P01 330 022
3
Measurement and
Instrumentation
4-20 mA
process signal
Power supply
Option Reference
85 - 265 Vac & 100 - 300 Vdc - P01 330 051
22 - 53 Vac & 10.5 - 70 Vdc
- P01 330 052
85 - 265 Vac & 100 - 300 Vdc RS485 P01 330 061
22 - 53 Vac & 10.5 - 70 Vdc RS485 P01 330 062
Thermocouple /
probe
2010
DIGI1 range
24 x 48 mm programmable panel meters for industrial use
> Display
Display resolution
Measurement rate
Display range
7-segment red LED display
Reading
Polarity
Overrun
Decimal position
> Accuracy
DIGI1-LP
DIGI1-P
DIGI1-E
DIGI1-T
DIGI1-F
DIGI1-ALP
-1,999 9,999
DIGI1-P
Material
Weight
Protection rating
Mounting
> Environment
> Power supply
High level
Low level
Consumption
DIGI1-E
DIGI1-T
32,000 counts
25/s
-1,999 9,999 -1,999 9,999 (dc) -1,999 9,999
0 9,999 (ac)
Height 10mm
4 digits
automatic
OVE display
Programmable using software
DIGI1-F
DIGI1-ALP
0 9,999
-1,999 9,999
Height 8mm
0.1% +3 counts
0.2% +3counts - 0.4% +4 counts for 100 V/Aac inputs
Pt 100
C : 0.2% + 1 count (Res 1) - 0.2% +4 counts (Res 0.1)
F : 0.2% + 2 counts (Res 1) - 0.2% +7 counts (Res 0.1)
J, K and T thermocouples
C : 0.4% + 2 counts (Res 1)
F : 0.4% + 4 counts (Res 1)
0.01% +1 count
0.1% +1 count
Operating temperature
Storage temperature
Relative humidity
Max. altitude
138
DIGI1-LP
62/s
-10C to +60C
-25C to +85C
< 95% to +40C
2,000 m
> Standards
1
Energy
Performance
DIGI1-LP
40 mm
DIGI1-P
DIGI1-E
DIGI1-T
70 mm
DIGI1-F
Network
Quality
(a)
48
(a)
22 (perage)
21.7
24
45 (perage)
DIGI1-ALP
100 mm
Measurement and
Instrumentation
22 (drilling)
45 (drilling)
139
DIGI2 range
2010
Simple programming
with 3 keys on front
panel
PRODUCT
ADVANTAGES
ECONOMICAL
single-function range
INSTANT FITTING
without tools
Accessories for
surface and DIN
rail mounting
140
Easy installation of
option boards
Reference
P01 3194 01
P01 3194 02
Quick connection
using plug-in
connectors
Reference
P01 3193 01
DC Voltage
D
irect (40Hz to 1 kHz):
20 V (90 k)
200 V (1 m)
600 V (3 m)
D
irect:
20 V (90 k)
200 V (1 m)
600 V (3 m)
Supply
115/230 Vac
24/48 Vac
12 Vdc
24 Vdc
48 Vdc
Supply
115/230 Vac
24/48 Vac
12 Vdc
24 Vdc
48 Vdc
Reference
5330 011F
5330 012F
5330 013F
5330 014F
5330 015F
Reference
5330 021F
5330 022F
5330 023F
5330 024F
5330 025F
DIGI2 PRC
Temperature
Pt 100
Process Signal
U/I
-100+200C (40/wires)
-200+800C (40/wires)
010 V (1 m)
020 mA (12.1 )
Supply
115/230 Vac
24/48 Vac
12 Vdc
24 Vdc
48 Vdc
Supply
115/230 Vac
24/48 Vac
12 Vdc
24 Vdc
48 Vdc
Reference
5330 061F
5330 062F
5330 063F
5330 064F
5330 065F
Reference
5330 051F
5330 052F
5330 053F
5330 054F
5330 055F
DIGI2 AAC
DIGI2 aDC
DIGI2 TTC
DIGI2 TAC
D
irect or on CT:
(40Hz to 1 kHz):
5 A (0.012 )
1 A (0.06 )
O
n shunt:
(40Hz to 1 kHz) :
100 mV (45 k)
60 mV (100 m)
D
irect:
5 A (0.012 )
1 A (0.06 )
O
n shunt:
100 mV (45 k)
60 mV (100 m)
J : -50+100C
-50+800C
K
: -50+200C
-50+1250C
T
: -200+400C
F
requency: 0 to 999.9Hz
S
peed: 0 to 9,999 counts
M
agnetic sensor:
Vin > 120 mVrms
N
AMUR sensor
E
ncoderTTL/24V or
NPN/PNP
D
ry contact
V
oltage: 0 to 10 Vac
Supply
115/230 Vac
24/48 Vac
12 Vdc
24 Vdc
48 Vdc
Supply
115/230 Vac
24/48 Vac
12 Vdc
24 Vdc
48 Vdc
Supply
115/230 Vac
24/48 Vac
12 Vdc
24 Vdc
48 Vdc
Supply
115/230 Vac
24/48 Vac
12 Vdc
24 Vdc
48 Vdc
Current AC
Current DC
Reference
5330 031F
5330 032F
5330 033F
5330 034F
5330 035F
Reference
5330 041F
5330 042F
5330 043F
5330 044F
5330 045F
Temperature
Thermocouple
Reference
5330 071F
5330 072F
5330 073F
5330 074F
5330 075F
Energy
Performance
AC Voltage
DIGI2 TPT
2
Network
Quality
DIGI2 VDC
Tachometer
3
Measurement and
Instrumentation
DIGI2 VAC
Reference
5330 081F
5330 082F
5330 083F
5330 084F
5330 085F
Accessories
and option boards
CT Current
transformers and shunts
> page 90
Tachometer
probe
> Contact us
Thermocouple / probe
141
2010
DIGI2 range
Programmable panel meters in 48 x 96
format for industrial applications
> Display
Display resolution
Display range
Display indicators
Reading
Polarity
Overrun
Decimal position
Measurement rate
AAC. VAC. ADC. VDC. PRC
TPT. TTC
TAC frequency
TAC speed
AAC. VAC. ADC. VDC. PRC
TPT. TTC
TAC
> Accuracy
> Environment
Operating temperature
Storage temperature
Relative humidity
Maximum altitude
142
32,000 counts
-1,9999,999
-1,9993,999
0999.9
09,999
Red LED 7 segments
Height 14.22 mm
4 digits
Automatic
OVE displayed
Programmable by software
4 measurements / second
2 measurements / second
0.1Hz to 7 kHz
0.1% 3 counts
0.1% +0.3C
0.1% +1C
0.1% +0.6C
0.4% +1C
0.1% 3 counts
-10C to +60C
-25C to +85C
< 95% at +40C
2,000 m
> Standard
1
Energy
Performance
Network
Quality
Measurement and
Instrumentation
45 (drilling)
92 (drilling)
92 (drilling)
143
2010
PRODUCT
ADVANTAGES
3 display
colours
MULTI-FUNCTION
PRODUCTS
3 DISPLAY COLOURS
4 alarms
as standard
INSTANT MOUNTING
WITHOUT TOOLS
SERIAL LINK
> Description
The C.A 2150-E is a programmable multi-rating panel meter which measures TRMS Vac
or Iac quantities and Vdc or Idc quantities.
The C.A 2150-M is a 4-in-1 programmable panel meter which can be configured for
process, temperature, load cell or potentiometer signals.
The C.A 2150-D is a 4-in-1 programmable panel meter which can be configured for the
following applications: meter, tachometer, frequencymeter and chronometer.
The serial link can be used to transfer the measurements onto a PC.
The CA2150-PRG software, available free of charge from www.enerdis.fr, can be used to
read the measurement directly, configure and remotely program one or more connected
panel meters.
It can also be used to save and recover the configuration of an existing panel meter.
144
AL 2-relay board
AL 4-relay board
4 NPN board
COM RS232 board
COM RS485 board
0 10 V output board
4 20 mA output board
Reference
P01 3193 01
P01 3193 03
P01 3193 04
P01 3193 06
P01 3193 07
P01 3193 10
P01 3193 11
> Accessories
Model
Multi-position mounting with
2 DIN rail adapters
Connector + 1 m RS232 cable
Connector + 1 m RS485 cable
Reference
P01 3194 01
P01 3194 03
P01 3194 04
C.A 2150-E
C.A 2150-M
C.A 2150-D
2 V with 75 k
2 0 V, 200 V or 600 V with 850 k
F
min: 0.01 Hz
Fmax without relay option: 19 kHz
F
max with relay option: 9.9 kHz
Frequencymeter / Tachometer
Load cells
2 V with 100 k
2 0 V, 200 V or 600 V
with 850 k
Potentiometer
2 00 mA with 0.75
1 A or 5 A with 0,014
5 0 mV, 60 mV or 100 mV
with 1.8 M
2 00 ...100 k
Energy
Performance
Meter / Chronometer
2
Network
Quality
3
Measurement and
Instrumentation
Communication board
Type of link
Protocol
Speed
Output connector
RS232C
RS485
ISO1745, C.A protocol or ModBus/RTU
1,200, 2,400, 4,800, 9,600 or 19,200 bauds
RJ11-6 with
RJ9-4
dual adapter
(input + output)
Model
Example
C.A 2150-M
Current transformers
and shunts
> page 90
0 10 V
0.1%
0.2 mV per K
> 500
4 20 mA
1 digit
0.5 A per K
< 800
Alarm
Analogue output
Digital communication
None : X
85-265 Vac & 100-300 Vdc : 1
2 relays : 1
22-53 Vac & 10.5-70 Vdc : 2
4 relays : 2
4 transistors : 3
None : X
4-20 mA : 1
0-10 V : 2
Tachometer
sensor
> Contact us
None : X
RS232 : 2
RS485 : 3
Thermocouple / probe
145
2010
> Display
Display resolution
Measurement rate
Display range
Displays
Reading
Polarity
Overrun
Decimal position
50 ms
19,999
C.A 2150-M
C.A 2150-D
32,000 counts
32,000 counts
Process/load
Pt100
Tc
Meter/chrono
Freq./Tacho.
50 ms
250 ms
100 ms
100 ms
0.1 to 9.9 s
Meter
Chrono
Freq./Tacho.
19,999
99,999
0 to 999.9
0 to 99,999
7-segment programmable colour LED (red, green, amber), height 14 mm
5 digits
automatic
OvEr / -OvEr
by programming
(30 mA)
(30 mA)
Operating temperature
Storage temperature
Relative humidity
Maximum altitude
-10C to +60C
-25C to +80C
< 95% at 40C
2,000 m
High level
Low level
Consumption
> Environment
146
C.A 2150-E
32,000 counts
C.A 2150-E
C.A 2150-M
Process/load/
Temperature
TC 0.4% R 0.6C
0.1% + 1 digit
0.4% R 1F
Pt100 0.2% 0.6C
0.2% 1F
Process: voltage 1 mV / current 1A
Load cell: 1 V
Temperature : 0.1 / 1 (selectable)
Frequency: 0.01 Hz
Chronometer: 0.01 s
100 ppm/C
50 ppm/C
Warm-up time
10 minutes
5 minutes
15 minutes
C.A 2150-D
Freq. / Tacho.
Meter
0.005% R
0.01% R
1
Energy
Performance
> Standards
Network
Quality
Measurement and
Instrumentation
45 (drilling)
45 (drilling)
92 (drilling)
147
2010
PRODUCT
ADVANTAGES
Simple
programming
using 5 keys
on front panel
RECORDING
of maximum and
Accessories for
surface or DIN
rail mounting
minimum values of
input variable
SERIAL LINK
of input signal
over 11 segments
Very simple
installation of
option boards
Quick connection
using plug-in
connectors
> Description
On the 4 instruments, two digital filters can be activated to stabilize the display of
measurements depending on the processing conditions.
The measurement display can be disabled remotely by closing a contact.The display and
reset of MAX and MIN values can also be activated remotely.
On the C.A 2200-P and C.A 2200-C, activation and cancellation of the OFFSET
function can also be controlled remotely. The OFFSET command functions may be
modified by the user, with 26 functions in all being pre-programmed on the instruments.
On the C.A 2200-P and C.A 2200-C models, the display can also be set to flashing
mode to indicate an alarm threshold overrun.
148
AL 2-relay board
AL 4-relay board
4 NPN board
analogue output board
BCD output board
COM RS232 board
COM RS485 board
Reference
P01 3193 01
P01 3193 03
P01 3193 04
P01 3193 05
P01 3193 08
P01 3193 06
P01 3193 07
> Accessories
Model
Multi-position fitting
with 2 DIN rail adapters
Rear fitting
with 2 DIN rail adapters
Connector + 1 m RS232 cable
Connector + 1 m RS485 cable
Kit of 4 x C.A 2200 screw connectors
Reference
P01 3194 01
P01 3194 02
P01 3194 03
P01 3194 04
P01 3194 06
C.A 2200-C
C.A 2200-P
Load cell
Voltage: 0 to 10 V with 1 m
C
urrent: 0 to 20 mA with 15
P
otentiometer: 200 to 100 k
C.A 2200-T
C.A 2200-D
to
to
to
to
M
agnetic sensor: Vin > 120 mVrms
NAMUR sensor:
Ion < 1 mAdc / Ioff > 3 mAdc / Rc = 1 k
TTL/24V encoder or NPN/PNP sensor:
1 > 1.6 Vdc / 0 < 1.5 Vdc
Dry contact: Vc = 5 V / Rc = 3.9 k/ Fc = 100Hz
Voltage: 10 to 650 Vac (Fmin 0.1Hz / Fmax 2 kHz)
Model
Example
C.A 2200-P
Alarm
Analogue output
Digital
communication
115/230 Vac: 1
without: X
2 relays: 1
24/48 Vac: 3
4 relays: 2
10/30 Vdc: 5
4 transistors: 3
without : X
0-10 V/4-20 mA : 1
3
Measurement and
Instrumentation
Network
Quality
Temperature
0
0
0
0
Energy
Performance
without: X
RS232: 2
RS485: 3
BCD: 4*
* Choice of the BCD output cancels the alarm and analogue outputs
Current transformers
and shunts
> page 90
Tachometer
sensor
> Contact us
Thermocouple / probe
149
2010
> Display
Display resolution
Display range
Display indicators
Reading
Polarity
Overrun
Decimal position
Display blocking
Measurement rate
Response time
> Function
C.A 2200-P
32,000
OFFSET function
C.A 2200-P
on keyboard
Remote control (4 logical inputs)
Sensor excitation
> Accuracy
Measurements
Temperature coefficient
Weight
Protection rating
Fitting
150
C.A 2200-T
C.A 2200-D
65,000 counts
Counter: 32,000
Tachometer: 099,999
32,000
32,000
Chronometer:
0.00 s to 9,999.9 h
Frequency meter: 0 to 25,000
Red LED 7 segments, Height 14 mm
5 digits
automatic
OVE displayed
Programmable by software
MAX/MIN function
16 measurements / second
62 ms (250, 425, or 775 ms depending on filter programmed)
C.A 2200-C
on keyboard
26 pre-programmed functions
C.A 2200-P
C.A 2200-C
120 mA at 5 or 10 V
120 mA at 5 or 10 V
or 30 mA at 24 V
C.A 2200-P
0.15 A or 0.3 A
50 ppm/C
C.A 2200-C
C.A 2200-C
0.01% R 2 counts
100 ppm/C
Polycarbonate VO as per UL
475 g (without option)
850 g (with options)
IP 65 on front panel
On panel using self-locking strap
C.A 2200-T
by programming
18 pre-programmed
functions
C.A 2200-D
on keyboard
Display blocking:
MIN/MAX/RESET
and clear MIN/MAX/RESET
display
C.A 2200-T
C.A 2200-D
8 V or 24 Vdc / 30 mA
C.A 2200-T
0.1C or 1C
100 ppm/C
C.A 2200-D
0.01% R 1 count
50 ppm/C
Operating temperature
Storage temperature
Relative humidity
2
Network
Quality
AC voltage
Consumption
DC voltage
Consumption
0 to +50C
-25 to +85C
< 95% at +40C
Energy
Performance
> Environment
> Standards
Measurement and
Instrumentation
92 (drilling)
45 (drilling)
92 (drilling)
151
152
Notes