Physics Practical Demo
Physics Practical Demo
PRESENTATION
By - Manmeet Singh
480/IC/11, ICE-2
1
AIM
To determine the susceptibility arising due to water
in the solution of manganese chloride (MnCl2).
PRINCIPLE
When a solution of a paramagnetic salt (here, MnCl2)
is taken in a tube and is placed between the poles of
a magnet, there is a rise in the liquid level. A
measurement of this rise enables to determine the
susceptibility of the solution.
APPARATUS REQUIRED
An electromagnet
Power Supply
Travelling Microscope
Gaussmeter with search coil
Funnel
Weight box
Flask
Weighing bottle
Water
Physical Balance
U-tube
THEORY
The magnetic field between the wedge-shaped pole
pieces varies rapidly along the vertical direction.
Thus, the force on the solution is vertical. The force
on a substance of volume V situated in a non-uniform
magnetic field in a place where the field strength is H
is given by:
F=1/2(k-k0) dH2/da*V
Where k is the magnetic susceptibility of the
substance.
h+d=(1 + /a)h
This is the height of the liquid column supported by
the forces arising from the magnetic field. If rho is
the density of the solution and g is the acceleration
due to gravity, then the weight of this column is:
7
2
2gh/H1
emu/cm
emu/gm.
PROCEDURE
Clean the U-tube with warm chromic acid.
Fill it with the solution of MnCl2.4H2O (of prepared
concentration).
The narrow end of the U-tube is placed between the
pole pieces of the electromagnet.
The level of meniscus is taken down.
The current(magnetizing) is noted down by means of
the ammeter (attached to the power supply).
10
11
OBSERVATIONS
S. No.
1.
2.
3.
4.
5.
6.
Current
(A)
0.5
1.0
1.5
2.0
2.5
3.0
1.35
2.7
4.07
5.44
6.4
7.36
1.8225
7.29
16.356
229.593
40.96
54.1649
5.662
5.662
5.662
5.662
5.662
5.662
Final
Height
(B)
5.666
5.677
5.695
5.719
5.739
5.745
H=B-A
0.04
0.15
0.33
0.57
0.77
0.83
12
GRAPH
Plot of h v/s H12
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0
0
10
15
20
25
30
35
40
45
H12
13
RESULT
The volume susceptibility at room temperature is:
0.0378
The mass susceptibility at room temperature is:
0.0108
The plot of h (y-axis) and H12 (x-axis) is a straight line.
14
PRECAUTIONS
Zero error should be checked in travelling
microscope.
The cross wire of the travelling microscope should be
placed right on the top of the upper meniscus of
solution before taking the reading.
The probe of the Gaussmeter should be held stably
while measuring the value of magnetic field.
15
ADVANCED APPLICATIONS
Determination of human iron stores or reserves in
the body.
Determination of magnetite content through the use
of magnetic susceptibility in large diameter holes.
Use of magnetic susceptibility probes in the
treatment of cancer.
Development of new ferromagnetic catheters for
Magnetic Resonance Imaging (MRI).
16
BIBLIOGRAPHY
www.wikipedia.com
www.tutorvista.com
www.physicsforums.com
Physics lab manuals
17
THANK YOU.
18