Boq
Boq
6.01
6.02
6.03
6.04
6.05
6.06
6.07a
6.07
6.08
6.09
Major Bridges
Clearing and grubbing at site which includes cleaning and removal of vegetation
growth from structures, channel and protective works as per direction of Engineer as
per Tech.Spec. Cl. 201
Dismantle existing cross drainage structure Including disposal of resulting material
and salvage reusable materials complete as per Tech.Spec.Cl. 202
a) Brick / Stone structure
b) PCC in Substructure
c) RCC in Superstructure
d) Stone Slabs in super structure
e) Steel I beams
f) HP ( > 300 dia)
g) Wearing coat
Earthwork in excavation for foundation of structures in all types of soil, including
setting out, construction of shoring and bracing, removal of stumps, and other
deleterious matter, dressing of sides and bottom and backfilling in layer with
approved mat
a) ordinary soil
b) in soft/weathered rock
c) in Hard Rock
Back filling behind abutments, wing walls, retaining walls, return walls and filling in
foundation Trenches complete as per drawing and Technical Specifications Clause
305, 309 and Clause 710.1.4 of IRC: 78
Providing and laying filter media behind abutments, box structures, wing walls &
return walls with well packed material to the specified thickness with smaller size
towards the soil and bigger size towards the wall complete with all leads and lifts as
per
Below stone pitching in side slopes
Providing and laying Plain Cement Concrete in base slabs, levelling course, filling
annular space around footing excluding reinforcement complete as per drawings and
Technical Specifications Sections1500, 1700 and 2100
a) M15 Grade - Levelling Course
b) M15 Grade - Annular Filling
c) M15 Grade - Below Approach Slab
d) M15 Grade - For Floor Protection Works
e) M20 Grade - For Floor Protection Works
Providing and laying Reinforced Cement Concrete in substructure/ wing walls/ return
walls etc. excluding reinforcement complete as per drawings and Technical
Specifications Sections 1500, 1700 and 2200.
Grade M25 in Sub-structure
Grade M25 in Foundation
Providing and laying Reinforced Cement Concrete in substructure/ wing walls/ return
walls etc. excluding reinforcement complete as per drawings and Technical
Specifications Sections 1500, 1700 and 2200.
Grade M30 in Sub-structure
Grade M30 in Foundation
Providing and laying Reinforced Cement Concrete in substructure/ wing walls/ return
walls etc. excluding reinforcement complete as per drawings and Technical
Specifications Sections 1500, 1700 and 2200.
Grade M35 in Sub-structure
Grade M35 in Foundation
Providing and laying Reinforced Cement Concrete M30 in superstructure excluding
reinforcement complete as per drawings and Technical Specifications Sections1500,
1700 and 2300
(a)RCC M30
(b)RCC M35
(c)PSC Grade
6.10
bridge
bridge
Total
Qunatity
ha.
0
Cu.m.
Cu.m.
Cu.m.
Sq.m
MT
m
sqm
0
0
0
0
0
0
0
0
Cu.m.
Cu.m.
Cu.m.
Cu.m.
0
0
0
0
Cu.m.
0
0
Cu.m.
Cu.m.
Cu.m.
Cu.m.
Cu.m.
0
0
0
0
0
0
Cu.m.
Cu.m.
0
0
0
Cu.m.
Cu.m.
0
0
0
Cu.m.
Cu.m.
0
0
0
Cu.m.
Cu.m.
Cu.m.
Cu.m.
0
0
0
0
0
Cu.m.
Cu.m.
Cu.m.
Cu.m.
Cu.m.
Cu.m.
Cu.m.
Leighton
0
0
0
0
0
0
0
0
0
6.11
6.12
6.13
6.14
6.15
6.16
6.17
6.18
6.19
6.20
6.21
6.22
6.23
Cu.m.
Cu.m.
Cu.m.
Cu.m.
0
0
0
0
0
0
0
0
0
0
0
0
Cu.m.
Cu.m.
Cu.m.
Cu.m.
Cu.m.
Cu.m.
Cu.m.
Cu.m.
0
0
0
Cu.m.
0
0
a) in PSC I Girders
Cu.m.
b) in PSC Voided slabs
Cu.m.
c) in PSC Box Girders
Cu.m.
Providing and laying Prestressed Cement Concrete M45 in SuperSturucture complete
as per drawings and Technical Specifications Sections 1500,1700,1800 and 2300.
0
0
0
0
a) in PSC I Girders
Cu.m.
b) in PSC Voided slabs
Cu.m.
c) in PSC Box Girders
Cu.m.
Providing and laying Prestressed Cement Concrete M50 in SuperSturucture complete
as per drawings and Technical Specifications Sections 1500,1700,1800 and 2300.
0
0
0
0
a) in PSC I Girders
Providing, cutting, bending and fixing in position of TMT bar reinforcement in
reinforced cement concrete structures complete as per Tech. Spec. Cl 1600
a) For sub-structure
b) For super-structure
c) For Foundation
Providing High Tensile Steel strands including all accessories for stressing and
jacking operations and grouting etc. complete as per Technical Specifications Section
- 1800
Providing and laying filter media behind abutments, box structures, wing walls &
return walls with well packed material to the specified thickness with smaller size
towards the soil and bigger size towards the wall complete with all leads and lifts as
per
Behind Abutment / Returnwall
Providing weep holes in abutments, returnwalls, with 100mm dia AC pipes complete
as per drawing and Tech. Spec. Cl. 2706
Providing and fixing Expansion joint
a) Filer board Expansion joint
b) Filler type Expansion joint.
b) Compression seal jt. in RC Slab / RC girder catering to maximum horizontal
movement upto 40 mm
c) Strip seal jt. catering to maximum horizontal movement upto 70 mm
Providing and fixing 20mm thick compressible fibre board in expansion joint
complete including cost and conveyance of all materials, labour, fixing in position,
etc., complete as per drawing and Tech. Spec. Cl. 2605
Providing and fixing Tar paper bearing complete as per drawing and IRC:SP:131973.
Providing, supplying, fitting and fixing in position true to line and level Elastomeric
Bearings conforming to IRC:83 (part-II) section IX complete as per Tech. Spec. Cl.
2000
Supply, fitting and fixing in position true to line and level POT-PTFE Bearings
complete as per Tech. Spec. Cl. 2000
Fixed Pot Bearing- 200 MT
Guided Pot-PTFE Bearing - 200 MT
Free Pot-PTFE Bearing - 200 MT
Fixed Pot Bearing- 150 MT
Guided Pot-PTFE Bearing - 150 MT
Free Pot-PTFE Bearing - 150 MT
Fixed Pot Bearing- 100 MT
Guided Pot-PTFE Bearing - 100 MT
Free Pot-PTFE Bearing - 100 MT
Page 2
Cu.m.
0
0
MT
MT
MT
MT
0
0
0
0
Cu.m.
no's
0
0
Rmtr
Rmtr
Rmtr
0
0
0
0
Rmtr
Rmtr
0
0
Sqm
cc
0
No's
No's
No's
No's
No's
No's
No's
No's
No's
Leighton
0
0
0
0
0
0
0
0
0
No's
No's
No's
No's
No's
No's
No's
No's
No's
No's
No's
No's
No's
No's
No's
No's
No's
No's
Each
Cu.m.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Rmtr
Sq.m
Rmtr
Rmtr
Sq.m
Sq.m
No's
Rmtr
Provide and lay boulder apron / floor complete as per Tech. Spec. Cl. 2503.
Provide and lay stone pitching as per Tech. Spec. Cl. 2504.
Providing and painting of flood gauge on substructure in full height and 500 mm
width as per IRC: 67-2001 and the directions of the Engineer.
FOR PILE FOUNDATIONS
Provinding Bored cast-in-situ M35 grade R.C.C. Pile in all types of soil including soft
rock (1000 dia) incl cost of all materials, labour, loading, unloading, lead upto 5 km,
curing, hire charges tech spec: 1100,1600,1700 excluding Reinforcement.
Cu.m.
Cu.m.
m
0
0
0
0
0
6.38
Provinding Bored cast-in-situ M35 grade R.C.C. Pile in all types of soil including soft
rock (1200 dia) incl cost of all materials, labour, loading, unloading, lead upto 5 km,
curing, hire charges tech spec: 1100,1600,1700 excluding Reinforcement.
6.39
Reinforced Cement Concrete M35 in pile caps complete as per drawing and technical
specification 1500, 1700, 2200.
Providing, cutting, bending and fixing in position of TMT bar reinforcement in piles
and pile caps structures complete as per Tech. Spec. Cl 1600
Conducting Load Tests on Piles
a) Initial Load Test on Pile
Vertical load test
Horizontal load test
b) Routine Load Test on Pile
Vertical load test
Horizontal load test
Cum
MT
6.24
6.25
6.26
6.27
6.28
6.29
6.30
6.31
6.32
6.33
6.34
6.35
6.36
6.37
6.40
6.41
6.42
6.43
High tensile steel wires/strands including all accessories for stressing, stressing operations and
grouting all complete as per Technical Specifications Clause 1800
0
0
0
0
0
0
0
0
MT
MT
MT
MT
MT
0
0
sqm
Leighton
6.44
6.45
6.46
6.47
6.48
6.49
b) Providing levelling pad in cement concrete M-20 grade below facia panels,
including earthwork in excavation, backfilling and profiling of fore slope complete as
per approved design, drawing and Technical Specifications Sections 300, 1500, 1700
and 2100
c) Providing Filter Media Behind Reinforced Earth Panel with well packed material to
specified thickness with smaller size towards the soil and bigger size towards the
wall complete with all leads and lifts as per approved design, drawings and Technical
S
d) Providing, Filling, grading and compaction with selected soil meeting approved
design parameters in layers in soil reinforced zone complete.
e) Providing and laying in position RCC Crash Barrier with Friction Slab complete as
per the approveddrawing and Technical Specifications Clause 809 and Sections
1000 and 1600.
RC Railings
Providing and fixing 150 mm dia. HDPE pipe of approved quality for drainage
purposes including clamping arrangement with the structure as per Tech. Spec. Cl
2705, 2708 and 2709 and as directed by Engineer all complete.
REPAIR OF EXISTING BRIDGES AND STRUCTURES
Removal of existing wearing coat including disposal with all leads and lifts complete
as per Technical Specifications Clause 2809 without causing any detrimental effect
on any part of the Bridge Structures.
Chipping of Plastering, cover concrete as surfaces of RCC member at bottom of deck
slab, pier and abutment faces upto reinforcement level or upto parent concrete
including safe scaffolding, labour, machinery etc. and disposing the debris beyond
work site
Providing
and
applying
migratory
corrosion
inhibitor
including
material,equipment,labour etc., complete of Krishna Conchem Products Pvt. Ltd of
its equivalent from Fosroc Chemicals or Degussa chemical as per manufacturers
specification.
Applying expoxy mortar over leached / honey combed and spalled concrete surface
and exposed stell reinforcement complete as per Technical Specfication clause 2804.
6.50
Providing and inserting nipples with approved fixing compound after drilling holes for
grouting as per Technical Specifications Section 2800 including subsequent cutting/
removal and sealing of the hole as necessary of nipples after completion of grouting
6.51
6.51
6.52
6.53
cum
cum
cum
Lm
rmtr
m
0
0
sqm
0
0
sqm
sqm
sqm
Nr.
0
kg
sqm
0
0
No
6.54
Dismantling the existing expansion joints saw cutting of the deck to the desired size
for creating a blockout, surface preparation including epoxy binder, installation and
welding of anchorage system, concreting of the block out with M-35 grade and instal
6.55
6.56
Plastering in CM 1:3
Carrying out repair of RCC M30 railing to bring it to the original shape, by cutting
and trimming the damaged portion to a regular shape, cleaning the area to be
repaired thoroughly, applying cement concrete after erection of proposed form work,
reinforce
Cleaning and removal of vegetation growth from structures, Channel and protective
works as per Technical Specifications and direction of the Engineer
Cleaning and removal of vegetation growth from structures, Channel and protective
works as per Technical Specifications and direction of the Engineer
Provide M-20 PCC toewall
sqm
m
0
0
sqm
sqm
cum
6.57
6.58
6.59
Page 4
Leighton
6.60
6.61
6.62
6.63
Providing and laying approved granular material Filling in Foundation Trenches as per Drawing
& Technical Specification clause 1008 and confirming to the IS-383
HDPE Pipe 150 mm dia
Sinking of wells through all types of strata ( pneumatic method of sinking) for all water depths
as per site conditions complete as per drg. and MORT&H specifications section 1200.
a) For 7.0m dia well
i)
Depth
0m to 3m
ii) Depth
3m to 10m
iii) Depth
10m to 15m
iv) Depth
15m to 20m
v) Depth
20m to 25m
vi) Depth
25m to 30m
vii) Depth
30m to 35m
viii) Depth
35m to 40m
ix) Depth
40m to 45m
x) Depth
45m to 50m
Supplying, fabricating and fixing in position mild steel cutting edge with MS anchorages for well
foundations including welding, splicing and making provisions for fixing of reinforcements of
well curb as per approved drg. and MORT&H specifications
Cum
Rm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
m
m
m
m
m
m
m
m
m
m
m
MT
6.64
Supplying & filling sand in wells complete as per drg. and MORT&H specifications clause 1209. Cum.
6.65
Carrying out confirmatory bores up to required depths at each foundation location of brdige
complete in all respects including testing as per MORT&H specifications section 2400 and
interpretation of bore data and presentation of the results as per IRC:78-
0
0
0
0
0
0
0
0
m
m
MT
Page 5
Leighton